• 제목/요약/키워드: 유동교란인자

검색결과 9건 처리시간 0.022초

유속과 유동교란인자에 의한 전자식 및 초음파식 유량계의 오차특성 연구 (A Study on Error Characteristic of Flow Disturbance and Velocity for Electromagnetic and Ultrasonic Flowmeters)

  • 이동근;박종호
    • 한국유체기계학회 논문집
    • /
    • 제12권5호
    • /
    • pp.33-38
    • /
    • 2009
  • In this study, the effect of flow disturbance such as contraction, expansion pipe and velocity deviation from low velocity of $0.1\;^m/s$ to $2.5\;^m/s$ on the error characteristics of the flowmeter was studied. Flow experiments using flowmeter calibration facility of K-water were undertaken for the cases of ultrasonic flowmeter based on transit-time method and electromagnetic flowmeter. Experimental results are presented that measurement error of expansion pipe are larger than contraction pipe. It is shown that the minimum straight length were required to remain of ${\pm}0.5%$ error for electromagnetic flowmeter and ${\pm}2.0%$ error for ultrasonic flowmeter.

유동교란인자(축소·확대관, Tee관)상하류에 설치된 다회선초음파 유량계의 특성 (Characteristics of Multipath Ultrasonic Flowmeter Installed Upstream and Downstream of Flow Disturbance Factors-Contraction, Expansion, and Tee Pipe)

  • 이동근;조용
    • 대한기계학회논문집B
    • /
    • 제36권8호
    • /
    • pp.877-883
    • /
    • 2012
  • 정확한 유량측정의 목적으로 다회선방식을 이용한 초음파유량계의 설치가 점차 증가하는 추세에 있으나 이에 대한 설치기준이 아직까지는 수립되어 있지 않아 현장설치 시 많은 혼선을 일으키고 있다. 따라서 측정의 정확도 확보에 영향을 주는 유동교란인자 중에서 확대관, 축소관 및 Tee관이 다회선 초음파유량계의 상하류에 설치되어 있는 경우에 필요로 하는 직관거리를 결정하기 위한 실험을 실시하였다. 실험대상으로는 정확도가 ${\pm}0.5%$ 이하인 제품으로 국산 5회선 2개, 외산 2회선 1개, 4회선 1개 등 4개의 제품을 선정하고 유량 즉, 유속과 직관거리별로 반복적인 실험을 통해 허용오차를 만족하는 설치기준을 제시하였다.

곡관후단의 직관거리와 센서위치에 따른 초음파유량계의 오차특성 (Error Characteristics of Clamp-on Ultrasonic Flowmeters Depending on Location of Sensors and Downstream Straight Run of Bent Pipe)

  • 이동근;조용
    • 대한기계학회논문집B
    • /
    • 제35권8호
    • /
    • pp.861-868
    • /
    • 2011
  • 관로를 통과하는 유체의 양을 측정하기 위해 설치된 유량계는 주기적인 교정과 비교측정을 통하여 측정의 정확도와 신뢰성을 확보하고 있다. 이때 사용되는 기준기는 휴대용 즉 센서가 관로의 외벽에 부착되는 건식 초음파유량계이며 사용되는 측정센서의 수량에 따라 1회선, 2회선, 4회선으로 구분된다. 본 연구의 대상은 K-water에서 주로 사용하고 있는 유량계를 선정한 후 직관거리가 충분히 확보된 상태에서 실험대상 유량계가 갖는 고유오차와 유동교란인자인 2중 곡관 후단에서의 직관거리별 오차에 대한 특성실험을 실시하였다. 실험결과를 기준으로 허용오차를 만족하는 센서위치 즉, 관로외부에 부착하는 각도와 곡관 후단으로부터의 이격거리 및 최적의 회선수를 제시하여 유량측정기술 향상을 통한 수처리 공정관리 및 유수율 제고기반을 마련하였다.

관상동맥의 기하학적 형상변화에 따른 동맥경화 위험도 (Atherogenic Risk Stratification According to Changes in the Geometrical Shape of the Coronary Artery)

  • 서상호;박준길;노형운;이병권;권혁문
    • 대한기계학회논문집B
    • /
    • 제34권10호
    • /
    • pp.893-899
    • /
    • 2010
  • 박동유동조건에서 관상동맥 내의 유동특성과 혈류역학적 인자 분포를 선행연구에서 수행하여 혈류역학이 관상동맥 내의 협착현상과 연관관계가 있음을 밝혔다. 동맥경화증의 호발부위인 관상동맥 분지부에서 혈류역학적 변수를 분석하여 동맥경화증의 발생기전을 규명하는 것이 본 연구의 목적이다. 동맥경화증에 의한 협착현상은 혈액과 혈관벽 사이의 생화학 반응뿐 아니라 유동박리나 벽전단응력과 같은 혈류역학적 인자와도 관계 있음을 확인하였다. 관상동맥 분지부의 분지각이 증가할수록 분지부 단면에서의 재순환영역의 크기가 증가하고 교란유동이 발생하게 된다. 이 재순환영역이 관상동맥에서 동맥경화의 시작점으로 의심되는 영역이라 할 수 있다.

밸브 하류에 설치된 건식 초음파유량계의 편차특성 (Deviation Characteristics of Clamp-on Type Ultrasonic Flowmeter Installed in Downstream of Valves)

  • 이동근;조용
    • 한국유체기계학회 논문집
    • /
    • 제15권4호
    • /
    • pp.12-18
    • /
    • 2012
  • This study was performed to found out the deviations for clamp-on type ultrasonic flowmeter installed in downstream of valves. It was selected three types of two-path flowmeter mainly used for K-water as test. Experiment carried out to confirmed characteristics of deviation depending on the sensor location, straight pipe length and maker for 1-path, 2-path and 4-path combined 2-path flowmeter. It was selected two kinds of valves with 100 % and 50 % opening, butterfly valves and gate valves, for flow disturbance factor. Finally, we suggested number of sensors by maker, straight pipe length and installed location of sensors satisfying the tolerance depending on the experiment results.

근사수평 반류성층 2상유동에서의 계면전단응력 및 마찰계수 (Interfacial shear stresses and friction factors in nearly-horizontal countercurrent stratified two-phase flow)

  • 이상천;이원석
    • 대한기계학회논문집
    • /
    • 제12권1호
    • /
    • pp.116-122
    • /
    • 1988
  • 본 연구에서는 공기와 물을 매질로 사용하여 3차원 계면파가 존재하는 근사수평 반류성층유동에서의 계면전단응력과 마찰계수를 결정하였다. 기상과 액상의 유량조건에 따라 3차원 계면파의 특성을 needle contact법에 의하여 측정 하였으며, 기상의 압력강하와 속도분포를 구하여 계면전단응력을 구하였다. 또 공학적인 응용을 위하여 3차원과 영역에서의 계면마찰계수에 관한 실험식을 개발하였다. 그리고 거칠은 고체표면에서의 마찰계수를 표현한 Nikuradse식을 이용하여 계면의 등가조도(equivalent roughness)를 계산하였으며 이것을 계면의 파고교란강도와 비교분석하여 계면전단응력에 영향을 미치는 인자들을 규명하였다.

표면 유체분출 수중날개의 유동해석 (Analysis on the Flow Field Around a Hydrofoil with Surface Blowing)

  • 표상우;서정천;김효철
    • 대한조선학회논문집
    • /
    • 제36권4호
    • /
    • pp.21-27
    • /
    • 1999
  • 본 논문에서는 교란 포텐셜을 기저로 하는 패널방법을 사용하여 물제트를 분사하는 플랩을 가진 타의 성능해석을 수행하였다. 받음각이 큰 경우, 성능해석의 주요 인자가 되는 후류면의 위치를 구하기 위하여 후류면의 roll-up을 포함시킨 Pyo[1]의 방법을 사용하여 계산하였고, 경계면은 쌍곡면 패널로 이산화하였다. 플랩타의 본체와 플랩 사이의 간극유동을 점성유동인 Couette유동으로 가정하여 계산하였고, 간극 사이에서 분사되는 물제트는 유량변화를 소스로, 모멘텀변화를 떨어져 나가는 보오텍스로 가정하여, 간극의 입구와 출구 패널 위에서 경계조건으로 포함시켜 계산하였다. 본 방법의 수치적 검증을 위해 실험값이 존재하는 경우에 대해 실험값과 프로그램의 수치결과를 비교하였다. 비교 결과, 실험값은 계산값과 좋은 일치를 보임을 확인하였다.

  • PDF

3-ring 임피던스미터의 유체 전기 전도도 독립성에 대한 실험적 연구 (Experimental Study of Characteristics of Three-Ring Impedance Meter and Dependence of Characteristics on Electric Conductivity of Fluids)

  • 김종록;안예찬;김무환
    • 대한기계학회논문집B
    • /
    • 제34권11호
    • /
    • pp.1027-1033
    • /
    • 2010
  • 2상유동(기체-액체) 현상은 전자기발전, 원자력발전, 철강산업 등 유체 시스템에 자주 나타나는 현상으로, 2상유동을 파악하는 것은 유체 시스템의 안정성 및 성능을 위해 중요하다. 2상유동 특성 중 기공률은 압력강하와 열전달 성능을 결정하는 주요 인자로서 이를 측정하는 기술이 특히 중요하다. 유동의 임피던스를 측정하여 기공률을 산정하는 임피던스법은 전기적 특성을 이용하기 때문에 반응속도가 빨라 실시간 측정이 가능하며, 유동관 벽에 전극을 설치할 경우 유동 교란없이 측정할 수 있는 장점이 있다. Coney는 원형관에 적용할 수 있는 ring 임피던스미터를 이론적 연구하였다. 본 연구에서는 Coney가 이론적으로 제안하고 실험적으로 검증하지 못한 3-ring 임피던스미터의 유체 전기전도도에 대한 독립성을 실험적으로 검증하였다.

메쉬 스크린을 이용한 초음속 제트소음 저감법에 관한 실험적 연구 (Study on Supersonic Jet Noise Reduction Using a Mesh Screen)

  • 권용훈;임채민;김희동
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2006년도 제27회 추계학술대회논문집
    • /
    • pp.377-381
    • /
    • 2006
  • 본 논문에서는 노즐출구 단면에 설치된 메쉬 스크린을 이용하여 초음속 제트 소음 제어하기 위한 실험을 수행하였다. 메쉬 스크린은 미소 직경을 가진 스테인레스 철사들로 만들어졌으며 철망 형태이다. 노즐 압력비는 과팽창에서 부족팽창된 초음속 제트를 얻기 위해 다양하게 변화시켰다. 초기 제트 전단층을 교란하기 위해, 메쉬 스크린의 중앙 부분에 구멍을 만들었으며 그 구멍크기는 메쉬 스크린의 소음 저감효과를 조사하기 위해 변화시켰다. 유동장을 가시화하기 위해 쉴리렌 광학 장치를 사용하였고 OASPL과 소음 스펙트럼을 얻기 위해 음향을 측정하였다. 본 실험으로부터 얻어진 결과는 메쉬 스크린이 스크리치 톤을 상당히 억제하였으며, 메쉬 스크린의 구멍크기는 초음속 제트 소음을 저감하는 중요한 인자였다. 과팽창된 제트인 경우, 소음 저감효과는 적정팽창과 부족팽창된 제트에서의 저감효과보다 매우 크게 나타났다.

  • PDF