• Title/Summary/Keyword: 유도초음파 검사

Search Result 139, Processing Time 0.032 seconds

Availability of Positron Emission Tomography-Computed Tomography for the Diagnosis of the Soft Tissue Tumor through Ultrasound-Guided Biopsy (초음파 유도하 침 생검을 이용한 연부조직 종양의 진단에 있어 양전자방출 컴퓨터 단층촬영술의 유용성)

  • Jun, Se Bin;Kim, Jeung Il;Lee, In Sook;Song, You Seon;Choi, Kyung Un
    • Journal of the Korean Orthopaedic Association
    • /
    • v.56 no.5
    • /
    • pp.398-403
    • /
    • 2021
  • Purpose: A biopsy is needed to diagnose soft tissue tumors. However, it is extremely difficult to pinpoint the site of a tumor due to the heterogeneity of sarcomas. Thus, even when an open biopsy is conducted, it is difficult to diagnose a soft tissue tumor. In such cases, an ultrasound (US)-guided biopsy is used to improve the diagnostic accuracy. This study evaluated the accuracy of US-guided biopsy for a diagnosis of soft tissue tumors found initially in a magnetic resonance (MR) perfusion and assessed the availability of positron emission tomography-computed tomography (PET-CT) for a diagnosis of soft tissue tumors. Materials and Methods: From January 2014 to December 2018, the US-guided biopsy was performed on 152 patients with a suspected soft tissue tumor found in an MR perfusion and 86 cases were definitively diagnosed with a soft tissue tumor. The accuracy of the US-guided biopsy was assessed retrospectively. Among the 86 cases, only MR perfusion was used before the biopsy in 50 cases, while both MR perfusion and PET-CT was conducted on 36 cases. The accuracy was analyzed to determine if the PET-CT could improve the precision of a biopsy. Results: From 86 cases, 34 out of 50 cases, in which only MR perfusion had been conducted, matched the result of the definitive diagnosis and the US-guided biopsy. 32 out of 36 cases, in which both PET-CT and MR perfusion were conducted, matched the definitive diagnosis and the US-guided biopsy. These results show significant differences in the accuracy of US-guided biopsy. In the case of soft tissue sarcomas, 6 out of 12 cases, in which only MR perfusion had been conducted, matched the result of the definitive diagnosis and the US-guided biopsy. 17 out of 18 cases, in which both PET-CT and MR perfusion were conducted, matched the definitive diagnosis. Moreover US-guided biopsy also showed significant differences in the accuracy of US-guided biopsy. Conclusion: In diagnosing soft tissue tumors, a US-guided biopsy is a well-known tool for its high accuracy. However, the heterogeneity of sarcoma makes it difficult to locate the exact site for a biopsy using only MR perfusion. Thus, the use of PET-CT will meaningfully improve the accuracy of a diagnosis by precisely targeting the site for the US-guided biopsy.

The Clinical Usefulness of Ultrasound-Guided Fine Needle Aspiration Cytology in Thyroid Nodules (갑상선 결절에서 초음파 유도 미세침흡인검사의 임상적 유용성)

  • Kim, Mi-Young;Park, Young-Sun
    • Journal of radiological science and technology
    • /
    • v.31 no.2
    • /
    • pp.141-147
    • /
    • 2008
  • Thyroid nodules are a common disease in clinical practice. Fine needle aspiration (FNA) is an accurate and safe method for the diagnosis of thyroid nodules. One of the limitations of FNA is the variable rate of unsatisfactory specimens, especially in small sized, deep seated or complex cystic nodules. To overcome this problem, ultrasound-guided FNA (US-FNA) has been widely used. In this study, the clinical usefulness of US-FNA cytology in thyroid nodules was investigated. Female to male ratio was 6.58:1. The incidence of nodules were 157 (43.1%) cases on the right, 130 (35.7%) cases on the left and 9 (2.5%) cases in isthmus. Total 139 cases (38.2%) belong to less than 1cm and 225 cases (61.8%) belong to more than 1cm. As for the echo type in the nodules, solid types were 255(70.1%), cystic type 39 (10.7%) cases, and the percentage of mixed type was 19.2%. The results show that US-FNA reduces the possibility of unsatisfactory cytologic specimens and the rate of false-negative diagnosis, and improves the diagnostic accuracy in investigation thyroid nodules.

  • PDF

Ultrasonographic and Magnetic Resonance Imaging Findings of Testicular Lymphoma (고환림프종의 초음파검사 및 자기공명영상 소견)

  • Cho, Jae-Ho
    • Journal of Yeungnam Medical Science
    • /
    • v.27 no.2
    • /
    • pp.105-112
    • /
    • 2010
  • Purpose : To evaluate the specific radiologic findings of testicular lymphoma which will be able to differentiated from other testicular tumors. Materials and Methods : Pathologically confirmed eight cases were included in this study. All eight cases were performed ultrasonography and four cases were performed magnetic resonance image. On ultrasonography, the size, location, shape, margin, internal echogenicity, homogeneity and vascularity were evaluated. On magnetic resonance image, the shape, margin, homogeneity, signal intensity on T1- and T2-weighted images, degree and homogeneity of the contrast enhancement and contrast enhancement change on dynamic enhancement study. Results : The margin of the mass was smooth on 6 of 8 patients. Internal echogenicity of the mass lesion was hypoechoic than normal testicular parenchyme on 7 of 8 patients. Four cases were homogeneous, 3 cases were relatively homogeneous and 1 case was heterogeneous. All 8 cases showed increased vascularity. The mass lesion was iso-signal intensity on T1-weighted image and low-signal intensity on T2-weighted image. All four cases were enhanced homogeneously and mildly than enhancing normal testicular parenchyme. On dynamic enhancement study, the mass lesion is progressively enhanced with time. Conclusion : The possibility of testicular lymphoma should be considered when testicular mass was homogeneously hypoechoic and low signal intensity on T2-weighted image in old age patients.

  • PDF

Development of a Modular Magnetostrictive Transducer for Torsional Guided Wave Transduction in a Cylindrical Structure (원통형 구조물에서 비틀림 유도초음파 변환을 위한 모듈형 자기변형 트랜스듀서 개발)

  • Cho, Seung-Hyun;Park, Jae-Ha;Kwon, Hyu-Sang;Ahn, Bong-Young;Lee, Seung-Seok
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.29 no.5
    • /
    • pp.427-435
    • /
    • 2009
  • Cylindrical structures such as pipes and shafts are widely used in various industrial facilities. Recently, researches on magnetostrictive transduction of torsional waves have been actively reported for the nondestructive evaluation of those cylindrical structures. However, the existing magnetostrictive patch transducer has somewhat inconvenient and time.consuming process like patch bonding to a structure since it should employ a magnetostrictive patch having strong magnetostriction. To overcome these limitations of the existing transducer, in this work, we develop a novel modular magnetostrictive transducer to generate and measure torsional waves to inspect a cylindrical structure. The proposed transducer can be applied as viscous liquid coupling with shear couplant or dry coupling without coupling media instead of patch bonding to a structure. We describe a detailed structure of the modular transducer and conduct some experiments to verify its performance.

Study on Ultrasonic Birefringence by Uniaxial Stress in Axisymmetric Solids (축대칭 고체내부의 단축 응력에 의한 초음파 복굴절 특성 연구)

  • Kim, Noh-Yu;Chang, Young-Chul
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.26 no.5
    • /
    • pp.336-342
    • /
    • 2006
  • Uniaxial stress in ail axisymmetric body is the simplest example of ultrasonic stress measurement. However, the birefringence theory cannot be applied for axisymmetric solids because the axisymmetric stress field in the body does not make shy velocity difference in SH waves propagating in the axisymmetric direction. Conventional ultrasonic technique using the time-of-flight method also needs ultrasonic lengths of the unstressed and stressed body, which is very impractical. In this paper, the birefringence effect in axisymmetric solids under uniaxial stress is formulated to evaluate the axial stress inside the solid without measuring tile ultrasonic length. Theoretical derivation for the birefringence characteristics in the axisymmetric solids is made using the longitudinal and shear waves instead of two horizontally polarized shear waves. Tension test is conducted for carbon-steel specimen to measure the birefringence coefficient and investigate the validity of the theory. It is observed from experimental results that the velocity difference in two differently polarized acoustic waves is proportional to the uniaxial stress in the axisymmetric solid with a good agreement with the theoretical value.

The Effectiveness of Ultrasonography-guided Injection at Infraspinatus of Shoulder in Patients with Posterior Shoulder Pain Induced Horizontal Adduction Test (수평내전에 의해 악화되는 견관절 후방 통증 환자에서 초음파하 극하근 주사요법의 효과)

  • Pak, Chi Hyoung;Moon, Young Lae;Lee, Hyeon Jun
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.8 no.1
    • /
    • pp.1-5
    • /
    • 2015
  • Purpose: The purpose of this study was to analyze the effectiveness of local steroid injection for infraspinatus under ultrasonographic guidance in patients with posterior shoulder pain during horizontal adduction test. Materials and Methods: Twenty one cases of patients, from May 2013 to May 2014, showed positive horizontal adduction test were retrospectively analyzed. We performed ultrasonography-guided infraspinatus injection using steroid to these patients in the outpatient clinics. We evalulated results for visual analogue score (VAS) for pain, UCLA score for these patients before injection, following 3 months and 6 months after injection. Results: After ultrasonography-guided infraspinatus injection using steroid, there were clinically significant improvements in VAS and UCLA score at 3 month's follow-up period (p<0.05). But there were no significant differences in VAS and UCLA score between 3 months and 6 months (p>0.05). Fourteen of 21 (67%) cases showed much improved and improved satisfaction. Respectively, seven of 21 (33%) cases showed not improved and aggravation satisfaction. Conclusion: Ultrasonography-guided infraspinatus injection using steroid is an effective treatment method for the patients with exacerbated posterior shoulder pain during horizontal adduction test.

  • PDF

A Study on the Optimum Generation Condition of Ultrasonic Guided Waves for Insulation Pipelines (단열된 배관의 유도초음파 최적 발생조건 선정에 관한 연구)

  • Lee, Dong-Hoon;Cho, Hyun-Joon;Kang, To;Park, Dong-Jun;Kim, Byung-Duk;Huh, Yun-Sil;Lee, Yeon-Jae
    • Journal of the Korean Institute of Gas
    • /
    • v.20 no.6
    • /
    • pp.50-57
    • /
    • 2016
  • Pipeline is one of the most abundant components in petrochemical plant. It plays a critical role in transporting fluids. Some pipelines are thermally insulated by wrapping them with insulating materials to prevent the loss of energy. However, when corrosion begins under insulation, it cannot be easily seen without unwrapping the cover, and thus corrossion should be detected using a non-destructive ways such as ultrasound guided wave. In this paper, the piping where the CUI (Corrosion Under Insulation) which occurs in the insulation parts guided waves effectively the optimum condition which is theoretical for selected guided waves phase velocity dispersion curve and wave-structure. The results of this study are expected to be directly utilized for onsite inspection of pipeline's CUI in many petrochemical plants.

Disseminated Septic Lesions Caused by Staphylococcus epidermidis Mimicking Cysticercosis Detected on Ultrasonography in a Pediatric Patient with Acute Myeloid Leukemia (급성 골수성 백혈병 소아환자에서 초음파 검사에서 낭미충증으로 오인된 표피 포도알균에 의한 파종 감염 병변이 발생한 증례)

  • Lee, Jae Min;Choi, Joon-Sik;Yoo, Keon Hee;Kim, Yae-Jean;Kim, Sun-Ja
    • Pediatric Infection and Vaccine
    • /
    • v.27 no.2
    • /
    • pp.134-139
    • /
    • 2020
  • Staphylococcus epidermidis is a part of the normal skin flora of humans. However, it can cause serious infections in people exposed to foreign bodies or in immunocompromised patients. A 13-year-old boy was hospitalized with fever and myalgia. Painful nodular lesions were detected on the scalp, arms, and legs. Pancytopenia and blasts were present in the peripheral blood. He was diagnosed with acute myeloid leukemia. Magnetic resonance imaging of the whole body showed multiple peripheral rim-enhancing, cyst-like lesions. Ultrasonography showed echogenic nodules inside the cystic lesions in the intramuscular space of the arms and legs. Therefore, cysticercosis was strongly suggested initially. However, an abscess was confirmed on sono-guided biopsy and S. epidermidis was isolated from a microbial culture of the tissue. We report a case of multiple disseminated lesions caused by S. epidermidis in a leukemia patient, initially mistaken for cysticercosis.

Evaluation of Size for Crack around Rivet Hole Using Lamb Wave and Neural Network (초음파 판파와 신경회로망 기법을 적용한 리뱃홀 부위의 균열 크기 평가)

  • Choi, Sang-Woo;Lee, Joon-Hyun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.21 no.4
    • /
    • pp.398-405
    • /
    • 2001
  • The rivet joint has typical structural feature that can be initiation site for the fatigue crack due to the combination of local stress concentration around rivet hole and the moisture trapping. From a viewpoint of structural assurance, it is crucial to evaluate the size of crack around the rivet holes by appropriate nondestructive evaluation techniques. Lamb wave that is one of guided waves, offers a more efficient tool for nondestructive inspection of plates. The neural network that is considered to be the most suitable for pattern recognition has been used by researchers in NDE field to classify different types of flaws and flaw sizes. In this study, clack size evaluation around the rivet hole using the neural network based on the back-propagation algorithm has been tarried out by extracting some features from the ultrasonic Lamb wave for A12024-T3 skin panel of aircraft. Special attention was paid to reduce the coupling effect between the transducer and the specimen by extracting some features related to time md frequency component data in ultrasonic waveform. It was demonstrated clearly that features extracted from the time and frequency domain data of Lamb wave signal were very useful to determine crack size initiated from rivet hole through neural network.

  • PDF

Nondestructive Diagnosis of NPP Piping System Using Ultrasonic Wave Imaging Technique Based on a Pulsed Laser Scanning System (펄스 레이저 스캐닝 기반 초음파 영상화 기술을 활용한 원전 배관 비파괴 진단)

  • Kim, Hyun-Uk;Lee, Chang-Gil;Park, Seung-Hee
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.1
    • /
    • pp.166-173
    • /
    • 2014
  • A noncontact nondestructive testing (NDT) method is proposed to detect the damage of pipeline structures and to identify the location of the damage. To achieve this goal, a scanning laser source actuation technique is utilized to generate a guided wave and scans a specific area to find damage location more precisely. The ND: YAG pulsed laser is used to generate Lamb wave and a piezoelectric sensor is installed to measure the structural responses. The measured responses are analyzed using three dimensional Fourier transformation (3DFT). The damage-sensitive features are extracted by wavenumber filtering based on the 3D FT. Then, flaw imaging techniques of a pipeline structures is conducted using the damage-sensitive features. Finally, the pipes with notches are investigated to verify the effectiveness and the robustness of the proposed NDT approach.