• Title/Summary/Keyword: 위험성 평가프로그램

Search Result 217, Processing Time 0.038 seconds

Studies on the Comparative Analysis Between GE Prodigy and $FRAX^{TM}$ Tool in Absolute Fracture Risk Assessment Tool (골절의 절대위험도 평가방법에서 GE Prodigy와 FRAX Tool의 비교분석에 관한 고찰)

  • Lee, Hwa-Jin;Lee, Hyo-Yeong;Yun, Jong-Jun;Lee, Mu-Seok;Song, Hyeon-Seok;Park, Se-Yun;Jeong, Ji-Uk
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.137-142
    • /
    • 2009
  • Purpose: World Health Organization (WHO) have suggested that an individual's 10-year absolute fracture risk is more reliable than Bone Mineral Density (BMD) measurement as the predictor of osteoporotic fracture. In 2008, Fracture Risk Assessment Tool ($FRAX^{TM}$) was developed by WHO to evaluate fracture risk of patients based on individual's clinical risk factors. The purpose of this study is to offer the comparative analysis of the existing GE prodigy and $FRAX^{TM}$ Tool in Absolute Fracture Risk Assessment Tool. Materials and Methods: 201 women ($55{\pm}3.5$ years) underwent femoral neck BMD measurement using GE Prodigy. The 10-year probability (%) of hip fracture (or a major osteoporosis-related fracture) was estimated using T-scores of GE prodigy and $FRAX^{TM}$. We made a comparative analysis of these data using SPSS (Ver.12). Results: There was a significant difference statistically between T-score ($-0.52{\pm}0.97$) of GE prodigy and T-score ($-1.45{\pm}0.81$) of $FRAX^{TM}$ (r=0.977, p=0.000). Also, there was a significant difference statistically between a major osteoporosis- related fracture ($9.15{\pm}3.71$) of GE prodigy and a major osteoporosis-related fracture ($4.87{\pm}1.51$) of $FRAX^{TM}$ (r=0.909, p=0.000). Moreover, a statistically significant difference was found in the 10-year probability of hip fracture of GE prodigy ($1.56{\pm}1.48$) and of hip fracture ($0.53{\pm}0.61$) of $FRAX^{TM}$ (r=0.905, p=0.000). Conclusions: There was a significant difference statistically between GE prodigy and $FRAX^{TM}$ Tool in Absolute Fracture Risk Assessment Tool. Especially, T-score, a major osteoporosis-related fracture and the 10-year probability of hip fracture that were estimated using GE prodigy tended to show the higher results than one evaluated by $FRAX^{TM}$ Tool. In conclusion, $FRAX^{TM}$ Tool may provide a better tool. The application of $FRAX^{TM}$ Tool as a fracture predictor remains to be clarified.

  • PDF

Prediction of Explosive Limits for Flammable Mixture Solution by Means of Solution Theory (용액론에 의한 가연성혼합용액의 폭발한계 예측)

  • 하동명
    • Proceedings of the Korean Institute of Industrial Safety Conference
    • /
    • 1999.06a
    • /
    • pp.69-72
    • /
    • 1999
  • 공정상에서 화재 및 폭발위험을 최소화하기 위해서는 공정의 안전과 최적화조작이 이루워 져야 하는데, 우선 작업 조건하에서 취급물질의 연소특성치 파악이 필요하다. 화학공정에 있어서 설계의 요지는 공정모사 프로그램이다. 최근에는 공정모사 프로그램에 응용하기 위해 열역학적 물성치 데이터베이스 연구에 화재ㆍ폭발 특성치 연구가 활발히 진행되고 있다. 이는 공장을 건설하기 전에 안전성 평가가 이루어져야 하기 때문이다. (중략)

  • PDF

Risk Assessment Technology of LNG Plant System (액화천연가스 플랜트 시스템 위험도평가 기술)

  • Choi, Song-Chun;Ha, Je-Chang;Lee, Mee-Hae;Jo, Young-Do;Chang, Yoon-Suk;Choi, Shin-Beom;Choi, Jae-Boong
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.29 no.2
    • /
    • pp.162-170
    • /
    • 2009
  • As one of promising solutions to overcome high oil price and energy crisis, the construction market of high value-added LNG plants is spotlighted world widely. The purpose of this manuscript is to introduce domestic activities to develop risk assessment technology against overseas monopolization. After analyzing relevant specific features and their technical levels, risk assessment program, non-destructive reliability evaluation strategy and safety criteria unification class are derived as core technologies. These IT-based convergence technologies can be used for enhancement of LNG plant efficiency, in which the modular parts are related to a system with artificial optimized algorithms as well as diverse databases of facility inspection and diagnosis fields.

A Study on the Application of Hazard Libraries When Using HAZOP in Hydrogen Systems (수소 전주기 시스템의 HAZOP 수행 시 위험 요인 라이브러리 적용 연구)

  • DOOHYOUN SEO;KWANGWON RHIE;DONGMIN LEE;DANBEE SHIN;HYOUNGI KIM;CHUNGHYUN LEE;TAEHUN KIM
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.34 no.4
    • /
    • pp.381-387
    • /
    • 2023
  • The risk assessment (safety assessment) must be performed to verify the risks during operation and installation of the hydrogen system and to ensure safe design and operation. Among them, hazard and operability study (HAZOP), a qualitative risk assessment, is most often used to discover risk factors and secure safety. However, in HAZOP performance, there is a difference in the level of evaluation results depending on the level and experience of the evaluator, and there is a high possibility that subjective results will be derived. This study aims to develop a risk factor library that can list and provide information on potential risk factors in order to solve these problems when performing HAZOP, reduce risk factors that are omitted or overlooked.

Assessment of the Effective Dose to the Human Body and Estimation of Lifetime Attributable Risk by CT Examination (CT 검사별 노출되는 유효선량과 생애 암 귀속 위험도 평가)

  • Cho, Yong In;Kim, Jung Hoon
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.2
    • /
    • pp.169-178
    • /
    • 2020
  • The number of CT scans is increasing every year due to the improvement of the medical standards of the public, and thus the annual dose of medical radiation is also increasing. In this study, we evaluated the effective dose of the human body exposed to CT scans and estimated LAR. First, five region were selected from the CT diagnostic reference level guideline, and the effective dose of human body exposed to each examination was evaluated by clinical CT device. Second, the human organs and effective dose were calculated using the ALARA-CT program under the same conditions. Third, lifetime attributable risk (LAR) estimated by the effective dose exposed through the previous CT scan was estimated. As a result, the most effective dose was 21.18 mSv during the abdomen 4 phase scan, and the dose level was below DRL for all other tests except for the abdominal examination. As a result of evaluating effective dose using a dose calculation program under the same conditions, the results showed about 1.1 to 1.9 times higher results for each examination. In the case of organ dose, the closer the organ to the scan site, the higher the scattering ray. The lifetime attributable risk to CT radiation dose in adults was gradually decreased with age, and the results were somewhat different according to gender.

Consideration on the Regulated Quantity of Preparation for Accidents by Risk Assessment (위험도 평가를 통한 사고대비물질별 규정수량 고찰)

  • Ahn, Gwangjae;Kim, Jungwook;Lee, Keunwon;Jung, Seungho
    • Korean Chemical Engineering Research
    • /
    • v.60 no.4
    • /
    • pp.506-511
    • /
    • 2022
  • In the Chemicals Control Act, a system was implemented to unify off-site risk assessment and risk management plan into the prevention and management system for chemical accidents. Among the hazardous chemicals which have been covered in system, the accident preparation substances are designated as chemical substances that are likely to occur and of which damage scale are likely to be large in the event of chemical accidents. In this study, risks were compared by selecting accident preparation substances with similar regulated quantities. In addition, risk assessment studies were conducted applying the accident scenarios. Four types of materials such as ammonia, hydrogen chloride, carbon disulfide and benzene were selected for the study, and risks were finally analyzed using Safeti 8.0, a quantitative risk assessment program by DNV. As a result, some materials are identified to have high risks comparing to other substances having similar regulated quantities.

A Study of Effect of commercial obesity management program using the special nutrient foods on weight control & Health risk reduction (특수영양식품을 적용한 상업성 비만관리 프로그램의 비만도와 건강위험 감소 효과에 관한 연구)

  • 김상연;구선영;박민정;김인혜;최유미;장유경
    • Proceedings of the KSCN Conference
    • /
    • 2003.05a
    • /
    • pp.120-120
    • /
    • 2003
  • 최근 들어 국내에서는 체중조절이 사회적인 문제로 다루어질 만큼 커다란 관심의 대상이 되고 있으며, 이에 체중조절을 시도하는 사람들도 급속히 증가하고 있어 이와 관련된 상업성 다이어트 업체들도 현저히 늘어나고 있는 실정이다. 한편, 특정 다이어트제품의 효능평가에 관한 연구는 보고되고 있으나 전체적인 상업성 비만관리 프로그램의 진행방법에 대한 내용이나 프로그램의 실제적인 체중감량 정도와 안정성 평가 등에 대한 연구보고는 전무한 실정이다. (중략)

  • PDF

Characterization of Non-structural Flood Mitigation Measures (비구조적 홍수저감대책 고찰)

  • Song, Jae-Ha;Jang, Ho-Yoon;Choi, Hyun-Il;Jee, Hong-Kee
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2011.05a
    • /
    • pp.429-429
    • /
    • 2011
  • 우리나라는 연중 강우량의 계절적 편중이 심하여 약 2/3이 6월-9월에 집중하는 기상학적 요인과, 국토의 약 70%가 산악지역으로 되어있는 지형학적 요인 등 홍수에 취약한 자연특성을 갖고 있으며, 특히 하천, 도시 저지대, 해안 및 산지에서는 홍수범람, 내부배제 불량, 해일, 산사태 등으로 매년 많은 인명피해와 재산상의 손실이 크게 발생하고 있다. 또한 최근 발생하고 있는 이상기후 현상과 각종 개발사업으로 인한 불투수면적의 증가 등으로 인해서 극한 홍수의 발생빈도가 높아가고 있으나, 기존 수방시설물의 홍수배제능력 부족 등으로 매년 많은 피해를 입고 있는 실정으로, 구조적인 대책만으로는 재해피해를 경감시키는데 한계가 있음을 인식하여 구조적 대책과 더불어 토지이용규제 및 개발규제, 홍수터관리, 홍수예경보 등 비구조적 재해대 비능력 향상이 시급한 현황이다. 우리나라의 경우, 구조적 수방기술의 발전은 비교적 높은 수준에 도달해 있지만, 구조적 대책에 비해 비구조적 대책의 개발 및 적용은 미흡한 형편이므로, 비구조적 홍수대책의 종합적 정비 및 효율적 운영방법 필요하다. 따라서 본 연구에서는 홍수유형별 발생원인별 대표적인 비구조적 홍수대책을 국내외 적용사례를 조사하여 분석하고, 비구조적인 홍수방어대책들에 대한 장단점 및 적용성 등의 정성적 평가를 실시하였다. 국내 여건에 적합한 홍수위험구역 설정방안을 제시하고자, 국내의 다양한 하천공간 확보를 위한 관련규정인 하천구역, 홍수관리구역, 수변구역, 상수원보호구역, 친수구역, 홍수위험구역, 자연재해위험지구, 방재지구 등에 대하여 조사하였으며, 국외 사례로 영국의 홍수위험구역 평가제도, 미국의 홍수터 관리 프로그램, 호주의 하천공간 분류 기준, 일본의 하천공간 설정 기준 등에 대한 고찰을 수행하였다. 또한 국내 홍수보험 제도의 문제점 분석 및 제고방안을 제시하고자, 현재 소방방재청 주관으로 시행되고 있는 풍수해보험제도에 대한 조사 및 분석을 실시하였으며, 미국에서 시행되고 있는 국가홍수보험프로그램, 프랑스의 자연재해보험, 스위스의 자연재해보험풀 제도, 일본의 홍수보험제도에 대하여 심층적인 고찰을 수행하였다.

  • PDF

A Study for Deducing the Problems and Improvements of Health Safety and Welfare Policy for Korean Firefighters by Delphi (델파이 기법을 통한 소방공무원 보건안전정책의 문제점 및 개선방안 도출)

  • Park, Chanseok
    • Journal of the Society of Disaster Information
    • /
    • v.16 no.1
    • /
    • pp.34-43
    • /
    • 2020
  • Purpose: In this study, we will try to find out problems and improvements of the policies in order to verify whether the plans contribute to the health and welfare of the firefighters properly. Method: By the Delphi analysis by experts. Result: There are problems such as absence of Firefighters' hospital, insufficient mental health education program in fire department, lack of on-site risk assessment system, problem on ineffectiveness of mental and physical health care business, lack of substantiality on mental and physical stability program, absence of mental health education, ensuring the confidentiality for users of mental health programs, lack of support for parent firefighters, lack of firefighters' retirement design and insufficient treatment for female firefighters. Conclusion: There are Improvements such as establishing Firefighters' hospital, improving mental health education and training CISD leaders in the fire department, preparing disaster risk assessment system, effectiveness measurement for visiting psychological counseling projects, improving the program through customer satisfaction surveys, establishment of mental health education system, ensuring confidentiality by improving personnel systems, encourage childcare leave and introduce childcare facilities at fire stations, revitalizing retirement Firefighters and policy development for female firefighters.

A Study on Facility Criteria of Small Petrol Stations based on Quantitative Risk Assessment (정량적 위험성 평가에 기반한 간이 주유취급소 시설기준에 대한 연구)

  • Park, Wooin;Ku, Jae-Hyun;Song, Yong-Sun
    • Journal of the Korean Institute of Gas
    • /
    • v.18 no.3
    • /
    • pp.44-52
    • /
    • 2014
  • Small petrol stations have great potential for a wide distribution in metropolitan area in which the land value possesses primary installation cost of the facility. The objective of the present study is to propose appropriate facility regulations of small petrol stations in Korea that can be popularly installed in the future in terms of securing safety in addition to serviceability. The hazard analysis and damage prediction from the possible fire and explosion accidents were performed using a software, PHAST v.6.5. As essential components of the facility regulations proposed in this study, the regulations about the refueling lot, maximum capacity of underground tank, location of fixed refueling facilities, height of firewall for small petrol stations were subsequently compared with those for regular-sized petrol stations.