• Title/Summary/Keyword: 위치트리거

Search Result 41, Processing Time 0.028 seconds

Proposal and Design of a Novel SNA Protocol for the Power Control System (전력제어 시스템을 위한 SNA 프로토콜 제안 및 설계)

  • Park, Min-Ji;Lee, Dong-Min;Min, Sang-Won
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.35 no.8B
    • /
    • pp.1122-1128
    • /
    • 2010
  • In this paper, we proposed and designed a novel SNA protocol which operates in the way of a server and a client in the power control system. The proposed SNA protocol includes the information about the mode switching, the saving position of context information, the user trigger, and so forth, which are needed in the power management devices. We consider the application of the SNA protocol to the home network, where message flows between the SNA server and the SNA client. To verify the operation of the SNA protocol, the state transition diagrams of the server in the home gateway and the client in the network device are shown. Hence, we can conclude the SNA can operate without malfuction.

Structural Analysis of the Lower Frame in the Multi-aerial Platform (복합굴절차의 하부 프레임에 대한 구조해석)

  • Kang, Sung-Soo
    • Journal of the Korea Society for Simulation
    • /
    • v.24 no.3
    • /
    • pp.69-75
    • /
    • 2015
  • This research focuses on structural stability of the multi-aerial platform. In this study, we conduct structural analysis for the lower structures such as sub frame, out-trigger and chassis frame, by using a universal structural analysis program NASTRAN based on 3D CAD data, material properties, load conditions and boundary conditions. We confirm the position of local stress exceeding the yield strength, through structural analysis of 4 cases for load conditions. As the results, it is possible to relax stress concentration in a way such as changing the thickness, reinforcing the material of the lower frames.

-On Acupoints & Trigger Points- Muscle fatigue evaluation using the Micro-electromagnetic stimulation (-경혈 및 트리거 포인트에서- 미약 자기장을 이용한 근피로 회복 평가)

  • Kim, Soo-Byung;Lee, Na-Ra;Shim, Tae-Kyu;Lee, Seung-Wook;Lee, Yong-Heum
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.5
    • /
    • pp.1231-1239
    • /
    • 2010
  • The aim of this study was developing the non-invasive focused magnetic stimulation system(NI_FMSS) that can stimulates acupoints which are small parts and knotted muscular tissues. To evaluate pain treatment effect of the NI_FMSS, we caused muscle fatigue to 25 subjects in biceps of the arm. Then, we stimulated acupoints(trigger points) HT2 using low frequency stimulator(10 subjects) and NI_FMSS(10 subjects). The other 5 subjects had not been stimulated. We analyzed muscle fatigue recovery with median frequency, RMS and median power in frequency domain for 5 days. We checked the magnetic stimulation effect on acupoint by evaluation of muscle fatigue recovery. Therefore, we identified that the NI_FMSS was more efficient system to relieve muscle pain than electric-stimulation system.

Review of Safety Measures through Analysis of Accidents on the Vehicle-mounted MEWP(mobile elevated work platforms) (차량 탑재형 고소작업대의 사고분석을 통한 안전대책 고찰)

  • Lee, Junho
    • Journal of the Korea Institute of Construction Safety
    • /
    • v.1 no.1
    • /
    • pp.47-56
    • /
    • 2018
  • In this paper, we analyze various cases of accidents caused by vehicle-mounted MEWPs(mobile elevated work platforms) which are most widely used for the high position level works, review the safety improvement measures for each of them, and propose basic data for the revision of related laws. The accidents by MEWPs were caused by the high level of works, which lead to fatal personnel accidents, so the measures for safety must be thoroughly carried out and the obligatory regulations by the related laws must be strictly observed. In this paper, we classify the cases of accidents at the workshop as 4 representative types and propose measures and remedies for them. According to the current regulations, it is possible to prepare for the accidents such as the wire rope breakage by switching to the all-chain drive method which does not have a daily use time limit instead of the wire rope drive method which is widely used at present. Also, it is suggested to add the daily use timetable to the nameplate attachment duty item according to the driving class.

A Proposal for a Femto-Cell Local Gateway and Packet Off-Loading for Remote Shipyards (원격 조선소의 펨토셀 로컬 게이트웨이 구성과 패킷 오프로드 방식 제안)

  • Lee, Won Hee;Min, Sang Won;Jeong, Min A;Lee, Seong Ro
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.38C no.4
    • /
    • pp.387-393
    • /
    • 2013
  • In shipyard site, a ship is constructed by integrating lots of modules that are made in several sites with different capabilities and specifications. Recently, it needs to make a shipyard to be smart with wired and wireless broadband networks between hierarchical shipyards. In this paper, we propose an installation of LTE femtocell local gateway at a remote shipyard, an information exchange method between hierarchical shipyards, and an offload method to separate the general traffic. We define the mode change in a femtocell gateway for supporting the offload of the general traffic between the headquarter and a remote shipyard, the offload data management and trigger message, and cache entry fields. To show the operation of our proposed off-loading function, we consider the transcipient message flow at the femtocell gateway with its state transition diagram. Hence, it is expected to increase the productivity of shipyard industry with mobile communications and broadband Internet technologies.

Performance of a Beamforming based RFID System for Velocity Estimation (속도 추정용 빔포밍 기반 RFID 시스템 성능 분석)

  • Jeon, Seong-ha;Jeon, Hyeon-mu;Yang, Hoon-gee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.8
    • /
    • pp.1925-1933
    • /
    • 2015
  • RFID based applications that combine radar techniques to obtain the location and the ID of a tag have widely been investigated. In this paper, we analyze a recently proposed RFID system that can extract the tag IDs and their velocities using signals transmitted from the tag attached moving objects and verify its performance. In the proposed system, a beacon transmits triggering signal at regular intervals into a monitoring area and the tag receiving the triggering signal backscatters the FMCW(frequency modulation continuous wave) signal modulated by the tag ID. The reader system demodulates this FMCW signal using predefined two reference signals to obtain not only the tag ID but its velocity. In this paper, we show that the proposed system works properly and analyze the degree of performance degradation in cases when the synchronization error between the transmitting signal and the reference signal occurs, and even when sampling rate is lowered for implementation purpose. Finally, the analytical results are verified by simulation.

Investigation of the Signal Characteristics of a Small Gamma Camera System Using NaI(Tl)-Position Sensitive Photomultiplier Tube (NaI(Tl) 섬광결정과 위치민감형 광전자증배관을 이용한 소형 감마카메라의 신호 특성 고찰)

  • Choi, Yong;Kim, Jong-Ho;Kim, Joon-Young;Im, Ki-Chun;Kim, Sang-Eun;Choe, Yearn-Seong;Lee, Kyung-Han;Joo, Koan-Sik;Kim, Byung-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.1
    • /
    • pp.82-93
    • /
    • 2000
  • Purpose: We characterized the signals obtained from the components of a small gamma camera using Nal(Tl)-position sensitive photomultiplier tube (PSPMT) and optimized the parameters employed in the modules of the system. Materials and Methods: The small gamma camera system consists of a Nal(Tl) crystal ($60{\times}60{\times}6mm^3$) coupled with a Hamamatsu R3941 PSPMT, a resister chain circuit, preamplifiers, nuclear instrument modules (NIMs), an analog to digital converter and a personal computer for control and display. The PSPMT was read out using a resistive charge division circuit which multiplexes the 34 cross wire anode channels into 4 signals (X+, X-, Y+, Y -). Those signals were individually amplified by four preamplifiers and then, shaped and amplified by amplifiers. The signals were discriminated and digitized via triggering signal and used to localize the position of an event by applying the Anger logic. The gamma camera control and image display was performed by a program implemented using a graphic software. Results: The characteristics of signal and the parameters employed in each module of the system were presented. The intrinsic sensitivity of the system was approximately $8{\times}10^3$ counts/sec/${\mu}Ci$. The intrinsic energy resolution of the system was 18% FWHM at 140 keV. The spatial resolution obtained using a line-slit mask and $^{99m}Tc$ point source were, respectively, 2.2 and 2.3 mm FWHM in X and Y directions. Breast phantom containing $2{\sim}7mm$ diameter spheres was successfully imaged with a parallel hole collimator. The image displayed accurate size and activity distribution over the imaging field of view Conclusion: We proposed a simple method for development of a small gamma camera and presented the characteristics of the signals from the system and the optimized parameters used in the modules of the small gamma camera.

  • PDF

Enhanced and Practical Alignment Method for Differential Power Analysis (차분 전력 분석 공격을 위한 향상되고 실제적인 신호 정렬 방법)

  • Park, Jea-Hoon;Moon, Sang-Jae;Ha, Jae-Cheol;Lee, Hoon-Jae
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.18 no.5
    • /
    • pp.93-101
    • /
    • 2008
  • Side channel attacks are well known as one of the most powerful physical attacks against low-power cryptographic devices and do not take into account of the target's theoretical security. As an important succeeding factor in side channel attacks (specifically in DPAs), exact time-axis alignment methods are used to overcome misalignments caused by trigger jittering, noise and even some countermeasures intentionally applied to defend against side channel attacks such as random clock generation. However, the currently existing alignment methods consider only on the position of signals on time-axis, which is ineffective for certain countermeasures based on time-axis misalignments. This paper proposes a new signal alignment method based on interpolation and decimation techniques. Our proposal can align the size as well as the signals' position on time-axis. The validity of our proposed method is then evaluated experimentally with a smart card chip, and the results demonstrated that the proposed method is more efficient than the existing alignment methods.

Development of a Small Gamma Camera Using NaI(T1)-Position Sensitive Photomultiplier Tube for Breast Imaging (NaI (T1) 섬광결정과 위치민감형 광전자증배관을 이용한 유방암 진단용 소형 감마카메라 개발)

  • Kim, Jong-Ho;Choi, Yong;Kwon, Hong-Seong;Kim, Hee-Joung;Kim, Sang-Eun;Choe, Yearn-Seong;Lee, Kyung-Han;Kim, Moon-Hae;Joo, Koan-Sik;Kim, Byuug-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.4
    • /
    • pp.365-373
    • /
    • 1998
  • Purpose: The conventional gamma camera is not ideal for scintimammography because of its large detector size (${\sim}500mm$ in width) causing high cost and low image quality. We are developing a small gamma camera dedicated for breast imaging. Materials and Methods: The small gamma camera system consists of a NaI (T1) crystal ($60 mm{\times}60 mm{\times}6 mm$) coupled with a Hamamatsu R3941 Position Sensitive Photomultiplier Tube (PSPMT), a resister chain circuit, preamplifiers, nuclear instrument modules, an analog to digital converter and a personal computer for control and display. The PSPMT was read out using a standard resistive charge division which multiplexes the 34 cross wire anode channels into 4 signals ($X^+,\;X^-,\;Y^+,\;Y^-$). Those signals were individually amplified by four preamplifiers and then, shaped and amplified by amplifiers. The signals were discriminated ana digitized via triggering signal and used to localize the position of an event by applying the Anger logic. Results: The intrinsic sensitivity of the system was approximately 8,000 counts/sec/${\mu}Ci$. High quality flood and hole mask images were obtained. Breast phantom containing $2{\sim}7 mm$ diameter spheres was successfully imaged with a parallel hole collimator The image displayed accurate size and activity distribution over the imaging field of view Conclusion: We have succesfully developed a small gamma camera using NaI(T1)-PSPMT and nuclear Instrument modules. The small gamma camera developed in this study might improve the diagnostic accuracy of scintimammography by optimally imaging the breast.

  • PDF

Case Study of the Shallow Seismic Refraction Survey using Wave Glider (웨이브글라이더를 이용한 천해저 탄성파 굴절법 탐사 사례)

  • Kim, Young-Jun;Cheong, Snons;Koo, Nam-Hyung;Chun, Jong-Hwa;Kim, Jeong-Ki;Hwang, Kyu-Duk;Lee, Ho-Young;Heo, Sin;Moon, Ki-Don;Jeong, Cheol-Hun;Hong, Sung-Du
    • Geophysics and Geophysical Exploration
    • /
    • v.20 no.1
    • /
    • pp.43-48
    • /
    • 2017
  • The applicability of refraction survey has been tested using a wave glider widely used in long-term ocean observations around the world. To record seismic refractions, a single channel streamer with metal weight and a seismic recording system were mounted on the wave glider. We used GPS precise time synchronization signal and radio frequency (RF) communication to synchronize shot and recorder triggers and to control acquired data quality in real time. When the wave glider is positioned close to the set point, a 2,000 J sparker is exploded along the designed track at 2 second intervals. Through the test survey, we were able to successfully acquire refractions from the subsurface.