• Title/Summary/Keyword: 위양성

Search Result 580, Processing Time 0.037 seconds

False positive and false negative reactions of acidic hydrogen peroxide for enhancing blood (Acidic hydrogen peroxide로 혈액을 증강할 때의 위양성 및 위음성 반응)

  • Lee, Wonyoung;Hong, Sungwook
    • Analytical Science and Technology
    • /
    • v.35 no.3
    • /
    • pp.124-128
    • /
    • 2022
  • Blood-sensitive reagents may exhibit false positives or negatives under the influence of substances other than blood. Since these reactions lead to the misinterpretation of blood evidence, it is essential to investigate the possibility of false-positive and -negative reactions of blood-sensitive reagents. Acidic hydrogen peroxide (AHP) is a recently discovered blood-sensitive reagent, and it is not yet known whether it causes false-positive or -negative reactions. To confirm this, 20 µL of blood was placed on metal surfaces, plastic surfaces, paper surfaces, paint surfaces, foods, vegetable oils, detergents, and petroleum hydrocarbons, and then AHP was applied. The blood was observed through an orange filter under a 505-nm light source, and no false-positive or false-negative reactions were observed with any of the substances/materials. However, it was confirmed that polyethylene terephthalate surfaces, polyvinylchloride surfaces, some paint surfaces, and foods exhibit their own photoluminescence under the conditions of blood observation, which interferes with blood observation.

False Positive of F-18 FDG-PET/CT due to Activated Charcoal Granuloma from Intraperitoneal Chemotherapy: A Case Report (복강 내 화학요법에 이용된 활성화 탄소 육아종에 의한 F-18 FDG PET/CT의 위양성 소견: 증례)

  • Lee, Se-Youl;Kim, Chan-Young;Yang, Doo-Hyun
    • Journal of Gastric Cancer
    • /
    • v.6 no.4
    • /
    • pp.291-294
    • /
    • 2006
  • F-18 FDG-PET/CT could be used to evaluate the surveillance of recurrent stomach cancer, but some cases reported as false-positives. The authors found an activated charcoal granuloma from intraperitoneal chemotherapy by using a curative resection and mitomycin C for stomach cancer. A mass behind the right colon that showed on CT 6 months after an operation in a 46-year-old male patient had no progression in size, but 36 months after the operation, an increase was seen on F-18 FDG-PET/CT, and a metastatic tumor was suspected. The tumor was resected by an explorative laparotomy and was diagnosed as being an activated charcoal granuloma based on the histologic finding. Based on this case, we should be reminded of the possibility of a false-positive on analysis of F-18 FDG-PET/CT caused by an activated charcoal granuloma in a patient who has intraperitoneal chemotherapy.

  • PDF

A study on the false-positive reaction of Kastle-Meyer(KM) test and the application of KM reagent (Kastle-Meyer(KM) test의 위양성 반응과 시약 적용 방법에 관한 연구)

  • Kim, Chae-Lin;Kim, Chang-Yong;Kim, Min-Yeong;Yu, Je-Seol
    • Journal of the Korea Convergence Society
    • /
    • v.11 no.10
    • /
    • pp.139-146
    • /
    • 2020
  • Kastle-Meyer (KM) test is one of presumptive tests used to detect latent blood in crime scenes. While this method is more sensitive than others, false positive reaction can be shown where blood does not exist. In this study, we tried to suggest a new application method to solve this problem. Reaction time and aspect of reaction of this new method was compared with two conventional methods in order to identify the effectiveness and identifiability. As a result, there was no statistically significant difference in sensitivity between the methods. In addition, in case of blood with a dilution ratio of 5000:1 or less, positive reaction showed immediately, making it easy to distinguish the reaction from false positive reaction. However, it became difficult to distinguish them with the reaction time as the dilution ratio increased, and this phenomenon could be supplemented observing aspect of the reaction when using the new method. Therefore, this study suggested a new method for KM test that can be used more accurately in the field.

Detection of Helicobacter pylori by Pre-embedding Immunoelectron Microscopy - Comparison with Immunoblotting Method (Pre-embedding Immunoelectron Microscopy를 이용한 Helicobacter pylori의 발견 - Immunoblotting법과 비교 -)

  • Jung, Hae-Seoung;Kim, Eun-Jung;Kim, Eun-A;Park, Ji-Hoe;Jun, Jin-Su;Seo, Ji-Hyoun;Lim, Jae-Young;Choi, Myoung-Bum;Woo, Hyang-Ok;Youn, Hee-Shang;Ko, Gyung-Hyuck;Baik, Seung-Chul;Lee, Woo-Kon;Cho, Myung-Je;Rhee, Kwang-Ho
    • Clinical and Experimental Pediatrics
    • /
    • v.45 no.7
    • /
    • pp.862-874
    • /
    • 2002
  • Purpose : We tried to evaluate whether the detection rate of Helicobacter pylori in gastric biopsy specimens could be improved by using pre-embedding immunoelectron microscopy. Methods : A total of 119 children who complained of upper gastrointestinal symptoms were endoscoped at the Gyeongsang National University Hospital from July, 1996 to July, 1999. Five biopsy specimens(three for urease test, one for hematoxylin-eosin(H & E) staining, and one for preembedding immunoelectron microscopy) were obtained from each antrum and body. Immunoblotting analysis were also performed. Results : Among the 119 patients, H. pylori were found in 116 patients(97.5%) by the immunoelectron microscopy. Among three patients who were found H. pylori negative in immunoelectron microscopy, two patients showed H. pylori in H & E stained slides and one patient was urease test positive(color change within six hours). Urease tests were positive in 107 patients(89.9 %). The positive rate of immunoblotting tests was 81.5%. However, only 13 patients(10.9%) showed H. pylori on the H & E stained antrum or body tissue. Conclusion : In this study, we found H. pylori histopathologically in most of the pediatric patients who complained of upper gastrointestinal symptoms. This study showed that pre-embedding immunoelectron microscopic examinations can be used as a gold standard in the diagnosis of childhood H. pylori infection. However, this method also has limited capacity to detect widely scattered H. pylori compared to the other histopathologic diagnostic methods.

Retrospective Analysis Study of False-Positive Amphetamine Immunoassay Cases and Negative Cases after Withdrawal while Taking Herbal Medicine-Containing Ephedra Sinica Confirmed in a Korean Medicine Obesity Clinic (한의 비만 클리닉에서 확인된 마황 함유 한약 복용 중 암페타민 면역측정법의 위양성 사례 및 휴약 후 음성 사례의 후향적 분석연구)

  • Byungsoo Kang;Suyong Shin; Jungsang Kim; Minwhee Kang; Donghoon Lee;Seonghyeon Jeon;Minwoo Bang
    • Journal of Korean Medicine for Obesity Research
    • /
    • v.24 no.1
    • /
    • pp.94-101
    • /
    • 2024
  • Herbal medicine (HM)-containing Ephedra Sinica (ES) has been associated with false-positive amphetamine immunoassay (FP IA) results. This study retrospectively evaluated the effects of dose, duration, and withdrawal instructions on FP IA and the safety of HM-containing ES at a clinic in Seoul from 2022 to 2023. The study included 6 patients in the FP IA group and 5 patients in the withdrawal instruction negative (Neg) group. The pre-test ephedrine alkaloids dose in the FP IA group was 95.17±31.90 mg, compared with 88.6±20.43 mg in the Neg group. The FP IA group had taken HM for 226.67±152.87 days before testing, and testing was performed while taking HM. In contrast, the Neg group had taken HM for 147.6±23.49 days and had 5.4±1.50 days of withdrawal period before the test following instructions of Korean medicine doctors. All adverse events (AEs) were moderate in severity, and the number of occurrences was similar: 5 in the FP IA group and 7 in the Neg group. AEs included constipation, insomnia (3 cases each), and palpitations (2 cases). The results of this study show that ES-induced FP IA can be resolved with withdrawal instructions and ES can be safely prescribed and administered by Korean medicine doctors. Further studies are needed to determine how to prevent FP IA after taking ES.

The Clinical Significance of STAT-PAK ULTRA FAST$^{(R)}$ and ICT Tuberculosis$^{(R)}$ for Serologic Diagnosis of Tuberculosis (폐결핵 진단을 위한 STAT-PAK ULTRA FAST$^{(R)}$와 ICT Tuberculosis$^{(R)}$의 유용성에 관한 연구)

  • Kim, Geun-Hwa;Park, Hee-Sun;Kim, Myung-Hoon;Kang, Dong-Won;Lee, Kyu-Seung;Ko, Dong-Seok;Suh, Jae-Chul;Jeong, Seong-Su;Kim, Ju-Ock;Kim, Sun-Young
    • Tuberculosis and Respiratory Diseases
    • /
    • v.47 no.3
    • /
    • pp.311-320
    • /
    • 1999
  • Background: In recent years, tuberculosis has re-emerged as a major health problem in both industrialized & developing countries. Recent advances in identifying & purifying antigens secreted in active tuberculosis infection have lead to the development of serological assays based on a number of immunodominant antigens. To date, the most sensitive and specific of these antigens has been the 38-kDa antigen. Method: Two rapid membrane-based serologic assays using antigen(38-kDa) from mycobacterium tuberculosis for the diagnosis of tuberculosis were evaluated in 22 patients with smear-positive pulmonary tuberculosis, 14 patients with inactive pulmonary tuberculosis, and 9 patients with non-tuberculous lung disease. Result: The evaluation of validity(sensitivity, specificity, positive predictive value, negative predictive value, false positivity and false negativity) of STAT-PAK ULTRA FAST$^{(R)}$ were 77.3%, 28.6%, 63.0%, 44.4%, 71.4 %, and 22.7% for differential diagnosis of active pulmonary tuberculosis and inactive pulmonary tuberculosis, respectively. The evaluation of validity of STAT-PAK ULTRA FAST$^{(R)}$ were 77.3%, 33.3%, 73.9%, 37.5%, 66.7%, and 22.7% for differential diagnosis of active pulmonary tuberculosis and non-tuberculosis. The evaluation of validity of ICT Tuberculosis$^{(R)}$ were 54.5%, 57%, 66.7%, 44.4%, 42.9%, and 45.5% for differential diagnosis of active pulmonary tuberculosis and inactive pulmonary tuberculosis. The evaluation of validity of ICT Tuberculosis$^{(R)}$ were 54.5%, 100%, 100%, 47.4%, 0%, and 45.4% for differential diagnosis of active pulmonary tuberculosis and non-tuberculosis. Conclusion: We concluded no effectiveness of STAT-PAK ULTRA FAST$^{(R)}$ & ICT tuberculosis$^{(R)}$on serologic diagnosis of pulmonary tuberculosis. In the future, further large-scale study should be needed for serologic diagnosis of pulmonary tuberculosis.

  • PDF

Spin MR Imaging : Pitfalls and Artifacts

  • 이영준
    • Proceedings of the KSMRM Conference
    • /
    • 1999.04a
    • /
    • pp.130-136
    • /
    • 1999
  • 척추의 MR촬영은 두부 다음으로 흔하게 시행되고 있는데, 척추의 해부학 적 구조물들은 일반적으로 널리 알려져 있고 이해하기가 쉽기 때문에 척추의 MR영상을 분석하는데 큰 어려움이 없을 수 있다. 관절부위를 포함한 근골격계 MR영상에서는 MR ar디facts가 병변을 관찰하는데 장애를 초래하여 위양성 혹은 위음성의 결과를 나타낼 수 있기 때문에 빈번히 언급되고 있다. 척추 MR영상을 판독하는 데는 다른 근골격계 영상에 비하여 artifact의 빈도 나 정도는 작지만, 의외로 많은 pitfall이나 ar디fact들이 관찰된다. 척추 MR 영상의 pitall과 artifact에 대한 정확한 인지와 이해가 필요한 이유는 MR영상에서 병변이 관찰되지 않거나 정상조직이 병변처럼 관찰될 수 있고, 또 병변의 특정을 잘못 판단할 수 있기 때문에 artifact를 교정하거나 최소화시키고, 방지할 수 있는 방법들을 사용하여 더욱 정확한 척추 MR영상의 결과를 얻는데 있다. 지면 관계상 모든 종류의 MR artifact를 언급하기 보다는 척추 MRI를 판독하면서 병변과 혼동을 주는 MR artifacts를 먼저 살펴보고, 진단적 오류를 범할 수 있는 pitfall들에 대하여 알아보도록 하겠다. 여기에서는 편의상 MR 촬영과 관계된 artifact들만을 artifact라고 하고 MR artifact와 직접적으로 연관이 없으면서 위양성이나 위음성을 초래할 수 있는 pitfall이나 variant를 pitfall로 묵어서 설명하겠다.

  • PDF

Comparison of Four Different Isolation Media for Staphylococcus aureus (황색포도상구균 분리배지 비교)

  • Oh, Min-Hee;Kang, Seong-Il;Hong, Sang-Phil;Oh, Se-Wook
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.38 no.5
    • /
    • pp.606-611
    • /
    • 2009
  • Performance test was carried out between selective media which are generally used in Staphylococcus aureus isolation from food. Sensitivity, determined according to the appearance of characteristic colonies when 30 different S. aureus strains were tested, resulted as Baird-Parker agar (RPF)> $Petrifilm^{TM}$ Staph Express plate> Baird-Parker agar> Mannitol salt agar. Also, the four different media showed the same selectivity because all tested media did not produce the false positive colonies. Recovery efficiency from the artificially inoculated foodstuff was almost the same for the tested media. Presumptive colonies were collected from the dried fishery product using Mannitol salt agar and collected strains were tested on 4 different selective agar. Almost presumptive strains did not show the false positive colonies except for S. carnosus ssp carnosus. This strain was identified as false positive colonies on Mannitol salt agar, Baird-Parker agar and $Petrifilm^{TM}$ Staph Express plate. But Baird-Parker agar (RPF) did not show the false positive colonies with the same strains. So, it was concluded that the Baird-Parker agar (RPF) has more higher selectivity than other tested media in this experiment.

Clinical Usefulness of PET-MRI in Lymph Node Metastasis Evaluation of Head and Neck Cancer (두경부암 림프절 전이 평가에서 PET-MRI의 임상적 유용성)

  • Kim, Jung-Soo;Lee, Hong-Jae;Kim, Jin-Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.26-32
    • /
    • 2014
  • Purpose: As PET-MRI which has excellent soft tissue contrast is developed as integration system, many researches about clinical application are being conducted by comparing with existing display equipments. Because PET-MRI is actively used for head and neck cancer diagnosis in our hospital, lymph node metastasis before the patient's surgery was diagnosed and clinical usefulness of head and neck cancer PET-MRI scan was evaluated using pathological opinions and idiopathy surrounding tissue metastasis evaluation method. Materials and Methods: Targeting 100 head and neck cancer patients in SNUH from January to August in 2013. $^{18}F-FDG$ (5.18 MBq/kg) was intravenous injected and after 60 min of rest, torso (body TIM coil, Vibe-Dixon) and dedication (head-neck TIM coil, UTE, Dotarem injection) scans were conducted using $Bio-graph^{TM}$ mMR 3T (SIEMENS, Munich). Data were reorganized using iterative reconstruction and lymph node metastasis was read with Syngo.Via workstation. Subsequently, pathological observations and diagnosis before-and-after surgery were examined with integrated medical information system (EMR, best-care) in SNUH. Patient's diagnostic information was entered in each category of $2{\times}2$ decision matrix and was classified into true positive (TP), true negative (TN), false positive (FP) and false negative (FN). Based on these classified test results, sensitivity, specificity, accuracy, false negative and false positive rate were calculated. Results: In PET-MRI scan results of head and neck cancer patients, positive and negative cases of lymph node metastasis were 49 and 51 cases respectively and positive and negative lymph node metastasis through before-and-after surgery pathological results were 46 and 54 cases respectively. In both tests, TP which received positive lymph node metastasis were analyzed as 34 cases, FP which received positive lymph node metastasis in PET-MRI scan but received negative lymph node metastasis in pathological test were 4 cases, FN which received negative lymph node metastasis but received positive lymph node metastasis in pathological test was 1 case, and TN which received negative lymph node metastasis in both two tests were 50 cases. Based on these data, sensitivity in PET-MRI scan of head and neck cancer patient was identified to be 97.8%, specificity was 92.5%, accuracy was 95%, FN rate was 2.1% and FP rate was 7.00% respectively. Conclusion: PET-MRI which can apply the acquired functional information using high tissue contrast and various sequences was considered to be useful in determining the weapons before-and-after surgery in head and neck cancer diagnosis or in the evaluation of recurrence and remote detection of metastasis and uncertain idiopathy cervical lymph node metastasis. Additionally, clinical usefulness of PET-MRI through pathological test and integrated diagnosis and follow-up scan was considered to be sufficient as a standard diagnosis scan of head and neck cancer, and additional researches about the development of optimum MR sequence and clinical application are required.

  • PDF