• Title/Summary/Keyword: 웰저항

Search Result 6, Processing Time 0.021 seconds

Pneumatics (Air powered) Training as an Exercise Paradigm Shift (운동패러다임 변화로서의 공압 트레이닝)

  • Lee, Woon-Yong;Hong, Sang-Min
    • Journal of Wellness
    • /
    • v.7 no.4
    • /
    • pp.187-199
    • /
    • 2012
  • The purpose of this review was to introduce a new training concept as pneumatic training method and how to apply the principles. Uses the new resistance, especially air powered that invisible, intangible, along with training on how to contribute to broadening their horizons, while attempts have been passed. Provide transition training methods in accordance with the trend of the times, and why these changes may be in the form of outside-free for theoretical consideration. From weight resistance, hydraulic, isokinetic exercise, and to pneumatic training why justification should apply for these training methods are presented also suggested the superiority of pneumatic training. In the near future, newly developed training method will be appear. In conclusion, it will be contribute to sports by concerning and applications to cutting edge training

Study on the Optimal CPS Implant for Improved ESD Protection Performance of PMOS Pass Structure Embedded N-type SCR Device with Partial P-Well Structure (PMOS 소자가 삽입된 부분웰 구조의 N형 SCR 소자에서 정전기 보호 성능 향상을 위한 최적의 CPS 이온주입에 대한 연구)

  • Yang, Jun-Won;Seo, Yong-Jin
    • Journal of Satellite, Information and Communications
    • /
    • v.10 no.4
    • /
    • pp.1-5
    • /
    • 2015
  • The ESD(electrostatic discharge) protection performance of PPS(PMOS pass structure) embedded N-type silicon controlled rectifier(NSCR_PPS) device with different partial p-well(PPW) structure was discussed for high voltage I/O applications. A conventional NSCR_PPS standard device shows typical SCR-like characteristics with low on-resistance, low snapback holding voltage and low thermal breakdown voltage, which may cause latch-up problem during normal operation. However, our proposed NSCR_PPS devices with modified PPW_PGM(primary gate middle) and optimal CPS(counter pocket source) implant demonstrate the stable ESD protection performance with high latch-up immunity.

Effects on the ESD Protection Performance of PPS(PMOS Pass Structure) Embedded N-type Silicon Controlled Rectifier Device with different Partial P-Well Structure (PPS 소자가 삽입된 N형 SCR 소자에서 부분웰 구조가 정전기 보호 성능에 미치는 영향)

  • Yang, Jun-Won;Seo, Yong-Jin
    • Journal of Satellite, Information and Communications
    • /
    • v.9 no.4
    • /
    • pp.63-68
    • /
    • 2014
  • Electrostatic Discharge(ESD) protection performance of PPS(PMOS pass structure) embedded N-type silicon controlled rectifier(NSCR_PPS) device with different partial p-well(PPW) structure was discussed for high voltage I/O applications. A conventional NSCR_PPS standard device shows typical SCR-like characteristics with low on-resistance, low snapback holding voltage and low thermal breakdown voltage, which may cause latch-up problem during normal operation. However, our proposed NSCR_PPS devices with modified PPW demonstrate the stable ESD protection performance with high latch-up immunity.

Development and Applicability of Discharge Capacity Testing Apparatus Using Penetration Method (관입식 복합 통수능 시험기의 개발과 적용성)

  • Yoo, Nam Jae;Kim, Dong Gun;Park, Byung Soo;Jun, Sang Hyun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.5C
    • /
    • pp.313-320
    • /
    • 2008
  • The discharge capacity testing apparatus using penetration method, being able to simulate in laboratory the condition of embedding plastic board drains in field, was developed to investigate consolidation characteristics of ground and to figure out discharge capacity of drains. The developed apparatus with a mandrel and penetrating device was designed to insert PBD into the ground prepared by previously applied pressure, being different from the conventional testing method that the drain was installed and the ground material was poured subsequently. Discharge capacity tests with the conventional apparatus as well as the newly developed one were performed to assess the applicability of the latter. As a result of tests, the conventional method showed delayed consolidation due to overall disturbance of ground and local deformation of drain caused by inhomogeneity of ground. Therefore discharge capacity of drain with the conventional apparatus was measured more or less larger than the expected values whereas discharge capacity with new one could be measured similar to the actual value in field.

Effects of Fitness Management Class for Wellness Convergence - Based on Fitness, Obese Indices, Metabolic Syndrome Factors - (융복합적인 웰니스를 위한 교양체육 수업의 효과 - 체력, 비만 및 대사증후군 지표 중심으로-)

  • Lee, Ji-Young;Kim, Myoung-Su;Lee, Shin-Ho
    • Journal of Digital Convergence
    • /
    • v.13 no.5
    • /
    • pp.329-336
    • /
    • 2015
  • The purpose of this study was to develop and manage fitness management class by experimenting effects of fitness management class on obese indices, metabolic syndrome risk factors and health and skill-related fitness in university students. Progress of fitness management class by exercise prescription program according to level of students health and fitness. Comparison of obesity indices, metabolic syndrome risk factors and health and skill-related fitness between fitness management class group and control(physical education class) group in before- and after-16week exercise prescription program. Decision of class contents and establishment of fitness management class. The effects of fitness management class appeared to higher than control group on obese indices, metabolic syndrome risk factors and health and skill-related fitness. In conclusions, we suggest that fitness management class for wellness convergence is effective for health promotion of students.

An Experimental Study on the Thermal Performance Measurement of Standing Column Well type Borehole Heat Exchanger (스탠딩컬럼웰형(SCW) 지중열교환기의 열성능 측정에 관한 실험적 연구)

  • Lee, Sanghoon;Choe, Yongseok;An, Kunmuk
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.122.2-122.2
    • /
    • 2010
  • Knowledge of ground thermal properties is most important for the proper design of BHE(borehole heat exchanger) systems. The configure type, pipe size and thermal performance of the BHE is highly dependent on the ground source heatpump system-efficiency and instruction cost. Thermal response tests with mobile measurement devices were developed primarily for in-situ determination of design data for Standing Column Well apply. The main purpose has been to determine in-situ values of effective ground thermal conductivity and thermal resistance, including the effect of ground-water flow and natural convection in the boreholes. The test rig is set up on a some trailer, and contains a sub-circulation pump, a boiler, temperature sensors, flow meter and a data logger for recording the temperature and circulation fluid flow data. A constant heating power is injected into the SCW through the test rig and the resulting temperature change in the SCW is recorded. The recorded temperature data are analysed with a line-source model, which gives the effective in-situ values of rock thermal conductivity and thermal resistance of SCW.

  • PDF