• Title/Summary/Keyword: 원형 유동관

Search Result 72, Processing Time 0.02 seconds

The Principles and Applications of Fluidized Bed Reactor with a Draft Tube (Draft Tube를 이용한 내부순환유동층 반응기의 원리와 응용)

  • 김상돈;송병호
    • Journal of Energy Engineering
    • /
    • v.2 no.1
    • /
    • pp.1-15
    • /
    • 1993
  • 내부순환유동층이란 전형적인 기-고체 유동층 내부에 보조장치로서 원형관(draft tube) 또는 평판(partition plate)을 삽입하여 단일용기를 두 개의 층으로 분리하고 층 사이의 개방면적(opening area)을 통하여 입자의 순환이 일어나도록 하는 반응기 형태이다. (중략)

  • PDF

Friction Factor for Circular Pipe with Uniform Roughness (균일조도 원형관 마찰계수)

  • Yoo, Dong Hoon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.13 no.5
    • /
    • pp.165-172
    • /
    • 1993
  • On the basis of Nikuradse laboratory experiments conducted in circular pipe with uniform roughness, five flow regimes are defined with respect to the characteristics of boundary layer such as laminar, transition laminar, smooth turbulent, transition turbulent and rough turbulent flows. Two cases are found for the transition laminar flow: one for the transition between laminar flow and smooth turbulent flow and the other for the one between laminar flow and rough turbulent flow. They all can be clearly determined by the relative roughness or the ratio of pipe diameter to the roughness. Explicit functions are developed for the estimation of pipe friction factor for the various flow conditions including turbulent flow regimes, which have excellent agreement with the Nikuradse laboratory data.

  • PDF

Numerical Study of the Flow Characteristics in a Diesel Exhaust System with a Vane-Type Static Mixer (베인 타입 스태틱 믹서의 기하학적 변수에 따른 디젤 배기관 내 유동특성에 관한 연구)

  • Kang, Kyoung-Nam;Lee, Jee-Keun;Kim, Man-Young
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.4
    • /
    • pp.397-404
    • /
    • 2012
  • In this research, a numerical study was carried out on the mixing and flow characteristics of a vane-type static mixer for the reduction of $NO_x$ in the SCR systems from the diesel exhaust environments. The mixer was located at a distance of 57 times the pipe diameter away from the inlet. The analyses were performed by changing various parameters such as vane angles, blockage ratio, and location of the vane. Flow characteristics through the mixer were characterized by the uniformity index, swirl number, and pressure drop. The results show that uniformity index, pressure coefficient and swirl number are substantially influenced by the vane angle, blockage ratio and position of the vane of the mixer. In particular, the swirl number was increased when the vane was located near the pipe wall, or the vane angle was increased or scale was extended.

Convective Heat Transfer Correlations for the Compact Heat Exchanger with Circular Tubes and Flat Tubes-Plate Fins (원형관 및 납작관-평판휜 형상의 밀집형 열교환기에 대한 대류열전달 상관관계식)

  • Moh, Jeong-Hah
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.3
    • /
    • pp.291-299
    • /
    • 2010
  • Aspect-ratio-based numerical analysis is carried out to investigate the air-side convective heat transfer characteristics in compact heat exchangers with circular tubes and flat tubes-plate fins. The RNG $k-{\varepsilon}$ model is adopted for turbulence analysis. The numerical analysis is carried out for aspect ratios ranging from 3.06 to 5.44 and for Reynolds numbers ranging from 1,000 to 10,000. The calculated results indicate a correlation between the friction factor and Colburn j factor in the compact heat exchanger system for the range of aspect ratios under consideration. The results obtained for circular tubes and flat tubes-plate fins in this study can be utilized to realize the optimal design of an air conditioning system.

A Study on Characteristics of Heat Transfer for a Rotating Heat Pipe with a Trigonal Cross Section (삼각 단면을 갖는 회전 열파이프의 열전달 특성에 관한 연구)

  • 이진성;김철주;김윤제;최영준;홍성은
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1997.10a
    • /
    • pp.114-121
    • /
    • 1997
  • 회전 열파이프의 열전달 성능은 액막 두께 및 증발부로 귀환되는 응축 액막 유동율에 의해 결정된다. 그 동안 응축액 유동율을 촉진시키기 위하여 용기 내벽에 groove, 테이퍼 및 나선형 코일을 삽입하여 유동율을 높이는 방법들이 연구되었다. 본 연구도 회전 열파이프의 내부 관벽 구조에 관한 것으로써 삼각 단면을 갖는 회전 열파이프의 열전달 특성을 파악하고자 하였다. 삼각 단면을 갖는 회전 열파이프는 고속 회전 영역에서 모서리 부분으로 액막이 집중되어 관 내벽에 형성되는 액막 두께를 줄일 수 있으나 증발부에서 국부적인 과열이 발생되어 불안정한 작동 상태를 나타내었다. 따라서 본 연구에서는 개선방안으로 증발부에 부분적으로 원형관을 접합하였으며, 그 결과 dry-out의 억제와 함께 삼각 유동 단면에 의한 액막 두께 감소 효과를 볼 수 있었다. 회전체 발열부 냉각에 적용시키기 위해서는 앞으로 최적의 기하학적 형상에 따른 충전율 및 액막에서의 열전달에 대한 정량적인 해석 연구가 필요할 것으로 생각된다.

  • PDF

Limit Loads for Circular Wall-Thinned Feeder Pipes Subjected to Bending and Internal Pressure. (원형 감육이 발생한 중수로 피더관의 한계하중 평가)

  • Je, Jin-Ho;Lee, Kuk-Hee;Chung, Ha-Joo;Kim, Jong-Sung;Kim, Yun-Jae
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.11
    • /
    • pp.1675-1680
    • /
    • 2010
  • Flow Accelerated Corrosion (FAC) occurring during in-service conditions results in localized wall-thinning in the feeder pipes of CANDU. The wall-thinning of the feeder pipes is the main degradation mechanisms affecting the integrity of piping systems. In this paper, we assess the integrity of wall-thinned feeder pipes by limit load analysis. The limit loads for wall-thinning feeder pipes subjected to in-plane bending and internal pressure were determined on the basis of finte element limit analyses. The limit loads are determined from the results of limit analyses of elasticperfectly-plastic materials using the large geometry change. Closed-form approximations of limit load solutions for wall-thinning feeder pipes subjected to in-plane bending and pressure are proposed.

The Effects of Top and Bottom Lids on the Natural Convection Heat Transfer inside Vertical Cylinders (수직 원형관 내부에서 발생하는 자연대류 열전달에서 상·하단 마개의 영향)

  • Kang, Gyeong-Uk;Chung, Bum-Jin
    • Journal of Energy Engineering
    • /
    • v.20 no.3
    • /
    • pp.242-251
    • /
    • 2011
  • The effects of top and bottom lids on the natural convection heat transfer phenomena inside vertical cylinders were investigated experimentally for $Ra_{Lw}$ from $9.26{\times}10^9$ to $7.74{\times}10^{12}$. Using the concept of analogy between heat and mass transfer, a cupric acid-copper sulfate electroplating system was employed as mass transfer experiments replacing heat transfer experiments. The natural convection heat transfer of both-open cylinders in laminar and turbulent flows was in good agreement with the existing heat transfer correlations developed for vertical plates. The effects of top and bottom lids on the heat transfer rates were very similar to the studies of Krysa et al. and Sedahmed et al. and Chung et al. With the copper lids, the bottom-closed cavity showed the highest heat transfer rates and then followed both-closed, top-closed, both-open ones in both laminar and turbulent flows. However with the acryl lids, the similar trends were observed except that the heat transfer rates for both-open were higher than top-closed one. The use of the copper lids increased the heat transfer rates compared to the acryl lids due to the hydrodynamic interaction of the flows developed for the different heated faces. This study extended the ranges of flow conditions of the existing literatures and proposed the empirical correlations.

Validity Review of Mixed Convection Flow Regime Map in Vertical Cylinders (수직 원형관내 혼합대류 유동영역지도의 유효성 검토)

  • Kang, Gyeong-Uk;Kim, Hyoung-Jin;Yoon, Si-Tae;Chung, Bum-Jin
    • Journal of Energy Engineering
    • /
    • v.23 no.3
    • /
    • pp.27-35
    • /
    • 2014
  • The existing flow regime map on mixed convection in vertical cylinders was investigated through an analysis of original literatures and its re-formation. The original literatures related to the existing map were reviewed. Using the investigated data and heat transfer correlations, the map was redrawn independently, and compared with the existing map. The redrawn map showed that mixed convection regime was not curved lines but straight lines and the transition regime was unable to be reproduced. Unlike the existing map with a little data, there are lots of data in the redrawn map. The reviews revealed that the existing map used the data selectively among the experimental and theoretical results, and a detailed description for lines forming mixed convection and transition regime was not provided. While considerable studies on mixed convection have been performed since that of Metais and Eckert, the existing map has still been used as the best method to distinguish natural, forced and mixed convection regime.

Explicit Equations of Normal Depth for Drainage Pipes (하수관 등류수심 양해법 산정식)

  • Yoo, Dong-Hoon;Rho, Jung-Soo
    • Journal of Korea Water Resources Association
    • /
    • v.38 no.7 s.156
    • /
    • pp.527-535
    • /
    • 2005
  • The computation of normal depth is very important for the design of channel and the analysis of water flow. Drainage pipe generally has the shape of curvature like circular or U-type, which is different from artificial triangular or rectangular channel. In this case, the computation of normal depth or the derivation of equations is very difficult because the change of hydraulic radius and area versus depth is not simple. If the ratio of the area to the diameter, or the hydraulic radius to the diameter of pipe is expressed as the water depth to the diameter of pipe by power law, however, the process of computing normal depth becomes relatively simple, and explicit equations can be obtained. In the present study, developed are the explicit normal depth equations for circular and U-type pipes, and the normal depth equation associated with Hagen (Manning) equation and friction factor equation of smooth turbulent flow by power law is also proposed because of its wide usage in engineering design.