• Title/Summary/Keyword: 원판

Search Result 658, Processing Time 0.02 seconds

Robust Position Control of a Reaction Wheel Inverted Pendulum (원판의 반작용을 이용한 역진자의 강인 자세 제어)

  • Park, Sang-Hyung;Lee, Hae-Chang;Lim, Seong-Muk;Kim, Jung-Su
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.26 no.2
    • /
    • pp.127-134
    • /
    • 2016
  • This paper presents a robust control of a reaction wheel inverted pendulum. To this end, a mathematical model is derived using physical laws, and then parameters in the model are identified as well. Based on the model, a robust position control is designed, which consists of two parts: swing-up control using passivity and robust stabilization control using LMI (Linear Matrix Inequality). When the pendulum starts to move, the swing-up control is applied. If the position of the pendulum is near the desired upright position, the control is switched to the robust stabilization control. This robust control is employed in order to deal with the uncertainties in the inertia of the pendulum dynamics. The performance of the proposed control scheme is validated not only simulation but also real experiment.

A Study on Condensation Heat Transfer in Air Pre-heating Heat Exchanger using Hydrophilic Surface (친수성 표면 처리를 통한 공기 예열 열교환기의 응축 열전달 성능 연구)

  • Park, Jae Won;Hwang, Sueng Sik;Seok, Sung Chul;Shin, Dong Hoon;Chung, Tae Yong;Son, Sueng Gil
    • Journal of Energy Engineering
    • /
    • v.23 no.3
    • /
    • pp.191-197
    • /
    • 2014
  • To increase the heat transfer rate of the air pre-heating heat exchanger used for the condensing boiler, We investigated condensation heat transfer coefficients through plasma surface treatment. The hydrophilic surface showed about 10% increase in heat transfer rate than original plate. It shows that Shah correlation can be used to predict the condensation heat transfer coefficient on the original surface within 10% error range after the compatison between Shah correlation and the condensation heat transfer coefficients measured on the hydrophilic surface and original surface. Therefore, we have shown that Shah correlation is available when designing the air pre-heating heat exchanger using the original surface in this study.

Clinical Effect of Arthrocentesis for Patients with Disc Displacement without Reduction of Temporomandibular Joint : Report of Cases (측두하악관절의 비정복성 관절원판변위 환자에 대한 관절강 세정술의 임상효과 : 증례보고)

  • Kim, Cheul;Kim, Young-Jun
    • Journal of Oral Medicine and Pain
    • /
    • v.31 no.2
    • /
    • pp.177-183
    • /
    • 2006
  • The management of refractory pain and limitation of mouth opening in the temporomandibular joint (TMJ) is both challenging and controversial. Arthrocentesis is a simple technique and it can be used instead of more invasive surgical procedures for patients who failed to conventional conservative treatments. The patients in this case report had complained persistent severe pain and restricted mandibular movement of TMJ, although they had been treated with conservative therapy, e.g., stabilization splint therapy, behavioral therapy, physical therapy, pharmacological therapy. Therefore we employed arthrocentesis for these patients, and they showed significant reduction of pain and improvement of mandibular movement after repetitive arthrocentesis. We recommend arthrocentesis as an effective, minimally invasive technique for patients with continuing severe pain and restricted mobility in the TMJ that is unresponsive to conservative management.

A Study on Resonance Frequencies of a Whispering Gallery Mode Dielectric Resonator Considering Electromagnetic Coupling Phenomena with an Excitation Part (여기부와의 전자파 결합 현상을 고려한 위스퍼링 갤러리 모드 유전체 공진기의 공진주파수에 관한 연구)

  • 황재효;민경일;구경완
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.9 no.5
    • /
    • pp.603-613
    • /
    • 1998
  • Resonant characteristic of Whispering modes(W. G. mode) on a dielectric disk resonator is influenced by an external circuit that is placed near the disk to excite this type of modes. In order to evaluate this phenomenon, we divide the disk resonator as two parts; a coupling part in which the mode coupling occurs and on uncoupled region. In the coupled part, we regard the part of the disk as a curved waveguide which is loaded with matched circuit, and derive a coupled mode equation for nonparallel dielectric waveguides. From the coupled mode equation, we calculate coupling coefficients and a coupled electromagnetic field. By using the complex coupling coefficients, we can calculate power transfer. We also calculate a resonant frequency in consideration of the mode coupling phenomenon. The calculated resonance frequence is confirmed by experiment for the resonance characteristics. As the results, it is found that the discrepancy between the theoretical and the experimental resonance frequencies is about 1.28% and the discrepancy between theory and experiment of FSR is about 0.6%.

  • PDF

Bioconversion of Pytogallo from Gallic Acid by Pseudomonas sp. KS-96 using Rotating Disc Contactor (회전원판 반응조를 이용한 Pseudomonas sp. KS-96에 의한 gallic acid로부터 Pyrogallol의 전환)

  • An, Seung-Man;Kim, Dong-Suck;Jeong, Young-Kee;Lim, Bock-Gu;Lee, Heung-Su;Ryu, Beung-Ho
    • Journal of Life Science
    • /
    • v.7 no.2
    • /
    • pp.112-118
    • /
    • 1997
  • In previous paper Pseudomonas sp. Ks-96 isolated from the bioconversion into pyrogallol from gallic acid . Continuous bioconversion of pyrogallol was carried out using rotatory disc contactor immobilized Pseudomonas sp. Ks-96 . Enzyme activity of gallate decarboxylase released from Pseudomonas sp. Ks-96 were shown at the highest activity on 24h incubation. Culture media containing gallic acid supplied on the flow rate of 20m${\ell}$/h until thickness of cells wall reached steady state. Bioconversion rate of pyrogallol from gallic acid showed at highest level ranging from 18hr to 36h according to time courses. Continuous bioconversion of pyrogallol using rotating disc contactor was about 82% and 80% between 6 and 8 days at the feeding rate of 300m${\ell}$ per hour in the medium containing 15g/${\ell}$ gallic acid.

  • PDF

Separation Performance of Disc Plate and Frame Type Reverse Osmosis System (원판틀형 역삼투 시스템의 투과성능)

  • 노상호;이종일;김영채;배성렬;정건용
    • Membrane Journal
    • /
    • v.10 no.3
    • /
    • pp.155-162
    • /
    • 2000
  • The reverse osmosis membrane housing(HY) was developed for excellent distribution of a feed solution, and the separation performance was compared with the commercialized Rochem(RC) system. The permeation flux of HY system was a little lower than that of RC system. On the other hand, the NaCl rejection ra4io was generally higher. Also, the permeation flux and rejection ratio for type A, B and C modules(disc plate and frame type) were measured using NaCl, sucrose and butanol solutions. The separation performance of type C module for NaCL and sucrose solutions was the most effective, and then those of type A and B were followed, respectively. However, the separation performance for butanol solution was type B, C and A order. The flux improvement ratio of type B to A increased as butanol concentration decreased or operating pressure increased up to 28 bar.

  • PDF