The Effects of the Capsule Density Uniformity on the Behavior of Cylindrical Capsules Transported through a Pipeline (관로를 통하여 수송되는 원통형 캡슐의 거동에 대하여 캡슐밀도의 균일성이 미치는 영향)

  • 이경훈
    • Water for future
    • /
    • v.26 no.4
    • /
    • pp.97-105
    • /
    • 1993
  • This paper presents the results of a study conducted to improve the understanding of the characteristics of cylindrical capsule flow in a pipeline by taking into account of the effect of capsule density uniformity. The effect of capsule density variation in the axial direction was studied both experimentally and anaytically. The experiments were conducted in a 190mm diameter straight pipe 17m long. The velocity, gap and tilt of capsules were measured under various conditions, In order to interpret the data on various capsule density conditions, the stability index given in the dimensionless number was introduced. The motion of capsules in pipelines is strongly affected by the stability of the capsules characterized by the stability index. The experiments conducted prover that the stability index is a valid criterion for explaining and correlating data on the capsule motion and the capsule density uniformity.

  • PDF

The Effects of the Capsule Density Uniformity on the Behavior of Cylindrical Capsules Transpored through a Pipeline (관로를 통하여 수송되는 원통형 캡슐의 거동에 대하여 캡슐밀도의 균일성이 미치는 영향)

  • 이경훈;이관수
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 1993.07a
    • /
    • pp.483-490
    • /
    • 1993
  • This paper presents the results of a study conducted to improve the understanding of the characteristics of cylindrical capsule flow in a pipeline by taking into account of the effect of capsule density uniformity. The effect of capsule density variation in the axial direction was studied both experimentally and analytically. The experiments were xonducted in a 190mm diameter straight pipe 18m long. The velocity, tilt of capsules and the gap between the capsule bottom and the pipe bottom were measured under various conditions. In order to interpret the data on the various capsule density conditions, the stability index given in the dimensionless numberwas introduced. The motion of capsules in pipelines is strongly affected by the stability of the capsules characterized by the stability index. The experiments conducted proved that the stability index is a valid criterion for explaining and correlating data on the capsule motion and the capsule density uniformity.

  • PDF

다공 켑슐 열매체의 구조응력해석

  • 강영환;주기남;이영신;최명환;신도섭
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1998.05b
    • /
    • pp.377-382
    • /
    • 1998
  • 재료 조사시험용 계장캡슐은 하나로(Hi-Flux Advanced Neutron Application Reactor : HANARO) 를 이용하는 조사시설중의 하나이다. 캡슐 내부에 있는 열매체는 다공 원통구조물로 고려되며, 다양한 형태와 크기를 갖는 조사시험용 시편이 각 단에 삽입된다. 조사시험에 대한 사용자의 요구조건을 효율적으로 충족시키기 위해서는 캡슐 열매체에 대한 여러 역학적인 특성을 파악하여 설계 및 제작할 필요가 있다. 따라서 계장 캡슐 설계의 초기단계로서 다양한 기하학적인 설계변수를 갖는 다공 캡슐 열매체의 구조적 특성을 파악하기 위한 연구를 수행하였다. 조사 분위기인 하중상태에서의 다공 구조물에 대한 구조응력해석을 수행하여 다공 매개변수에 따른 응력 및 변위 등을 고찰하였고, 구조물의 건전성을 평가하였다.

  • PDF

An Experimental Study on Close-Contact Melting in Horizontal Capsules with Circular or Rectangular Cross Sections (원형 및 사각단면을 가지는 수평캡슐에서의 접촉용해에 관한 실험적 연구)

  • Kim, Si-Pom;Lee, Chi-Woo
    • Solar Energy
    • /
    • v.13 no.1
    • /
    • pp.39-48
    • /
    • 1993
  • This empirical paper addresses the phenomena of the contact melting of PCM in horizontal capsules of circular and rectangular cross sections with various aspect ratio. The melting-rate tends to increase as the Stefan number increases. The case of rectangular tube displays larger melting-rate than that of circular tube, and the melting-rate increases as the aspect ratio decreasws for rectangular tubes. In case of circular tube, the effect of natural convection on the melting-rate is 6.1%, 8.6% and 11.2% according to Stefan number 0.0772, 0.1287 and 0.1802 respectively.

  • PDF

An Experimental Study on Heat Storage and Heat Recovery Characteristics of a Latent Heat Storage Tank with Horizontal Shell and Tube Type (수평식 셸-튜브형 잠열축열조의 축열 및 방열특성에 관한 실험적 연구)

  • Kwon, Young-Man;Seo, Hye-Sung;Moh, Jung-Ha
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.1
    • /
    • pp.50-59
    • /
    • 2000
  • An experimental study has been carried out in order to investigate the heat storage characteristics for a latent heat storage tank with horizontal shell and tube type. The heat exchanger consisted of horizontal cylindrical capsules with a staggered tube bank layout. Based on the obtained data, the effects of flow rate and inlet fluid temperature on the melting time and heat storage rates were examined. It is found that the melting time decreased with increase of the flow rate and the inlet temperature. Results also show that at the initial stage of heat transfer the heat storage rate represents the maximum value and rapidly decreases.

Composite Endoscope Image Construction based on Massive Inner Intestine Photos (다량의 내장 사진에 의한 화상 구성)

  • Kim, Eun-Joung;Yoo, Kwan-Hee;Yoo, Young-Gap
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.44 no.1
    • /
    • pp.108-114
    • /
    • 2007
  • This paper presented an image reconstruction method based on the original capsule endoscopy photos yielding a 2-D image for faster diagnosis proposes. The proposed method constructed a 3-D intestine model using the massive images obtained from the capsule endoscope. It merged all images and completed a 3-D model of an intestine. This 3-D model was reformed as a 2-D plane image showing the inner side of the entire intestine. The proposed image composition was evaluated by the 3-D simulator, OpenGL. This approach was demonstrated successfully. A physician can find the location of a disease at a glance because the composite image provided an easy-to-understand view to show the patient's intestine and thereby shorten diagnosis time.

Experimental Study on the Cold Storage of Spherical Capsules in the Cylindrical Tank (원통형 축냉조내 구형캡슐들의 축냉에 관한 실험 연구)

  • ;;Jung, Gab Yong
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.10
    • /
    • pp.2647-2656
    • /
    • 1995
  • The present work was performed to axially and radially investigate the local cold storage performance in the cylindrical tank with the spherical capsules inserted n-Tetradecane as a new cold storage material. The local cold storage performance of the capsules in the tank was experimentally investigated for the inlet temperature of -7, -5, -3, 0.deg. C, for the flow rate of 0.95, 1.89, 2.84, 6.00 l/min, and for the diameter ratio of 4.9, 9.0, 13.1. The local cold storage performance in the case of using water applied for the commercial ice-ball system was axially investigated by changing the flow rate only with the inlet temperature of -7.deg. C and the diameter ratio of 9.0 in order to compare with the performance in the case of using n-Tetradecane. For the case of using n-Tetradecane, the difference of cold storage period between the first and the seventh story was increased as the inlet temperature was increased and the flow rate was decreased. The capsules at the center of the tank showed the supercooling and the increased cold storage period compared with the capsules at the wall of the tank due to the small porosity and insufficient cold storage performance at the center of the tank as the diameter ratio is increased. The case using water showed worse cold storage performance due to comparatively large supercooling than the case using n-Tetradecane.

Heat Transfer Chracteristics in a Fluidized bed Heat Storage System Using Encapsulated PCM (캡슐화된 PCM을 이용한 유동층 축열조에서 열전달 특성 연구)

  • Yoon, Y.H.;Han, G.Y.;Kang, Y.H.;Kwak, H.Y.;Lee, T.K.;Jeon, M.S.
    • Solar Energy
    • /
    • v.18 no.3
    • /
    • pp.89-94
    • /
    • 1998
  • The heat transfer characteristics of a fluidized bed latent heat storage system using encapsulated PCM was investigated. The cylindrical test section has the dimension of 50 mm I.D. and 40 cm in height. The phase change material(PCM) was the sodium acetate and was encapsulated by the multiple layers of PMMA and paraffin wax. The size of encapsulated PCM was $2{\sim}3mm$ and melting point was $58^{\circ}C$. The instantaneous heat storage and heat release rates were determined and the instantaneous heat transfer coefficient based on the fluidized bed volume was also determined. The effect of inlet temperature and velocity of heat transfer fluid on the heat transfer coefficient was also investigated.