• Title/Summary/Keyword: 원통의 체적변화

Search Result 15, Processing Time 0.025 seconds

Analysis on the volume variation of bag-net in set-net by acoustic telemetry (음향 텔레메트리에 의한 정치망 원통의 체적 변화 해석)

  • Tae, Jong-Wan;Shin, Hyeon-Ok
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.40 no.2
    • /
    • pp.115-125
    • /
    • 2004
  • An experiment to measure the volume variation of bag net in a set-net by acoustic telemetry system was conducted in Jaran Bay, Gosung, Korea on 10 April to 23 April 2003. The long baseline telemetry system consists of three radio-acoustic linked positioning (RAP) buoys, a time controller with a personal computer and seven pingers. Six pingers were attached on the bottom of the bag-net and the other one was fixed on the sea bed. The results obtained are summarized as follows : 1. The average RAP buoy fixing errors of x-axis, y-axis, and z-axis were 0.2m, 0.4m, and 0.1m, respectively. 2. In the neap tide the minimum and maximum volume of the bag-net on 11 April 2003 were 4,173$m^3$(17:00) and 4,757$m^3$(12:00), respectively. The average current direction and speed at those times were 99.9$^{\circ}$, 12.9cm/s and 104.0$^{\circ}$, 2.4cm/s, respectively. 3. In the spring tide on 17 April 2003, the minimum and maximum volume were 2,016$m^3$(18:30) and 4,454$m^3$(15:00), respectively. The average current direction and speed at those times were 315.6$^{\circ}$, 16.1cm/s and 289.0$^{\circ}$, 5.7cm/s, respectively. 4. In conclusion the maximum variation of the volume on 17 April to 20 April 2003 was 3,552$m^3$ and it was larger 1.4 times than time on 11 April to 16 April 2003.

Failure Analysis of RC Cylindrical Structures using Layered Shell Element with a Pressure Node (압력절점을 갖는 적층쉘 요소에 의한 콘크리트 원통형 구조물의 파괴해석)

  • 송하원;방정용;변근주;최강룡
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.12 no.3
    • /
    • pp.475-484
    • /
    • 1999
  • 압력절점은 요소의 균등한 압력증분을 1개의 자유도로 갖는 절점이며, 유한요소의 하중-변위 평형방정식에 체적과 압력의 관계를 추가하여 한계압력 이후에서도 체적변화에 따른 압력증분을 직접적으로 제저할 수 있는 절점이다. 본 연구에서는 철근콘크리트의 평면 구성 방정식과 적층정식화에 적용한 쉘 요소에 압력절점을 추가하고 해석시 체적을 제어함으로써 철근콘크리트 원통형 구조에 대해 파괴까지의 극한내압 능력을 해석할 수 있는 체적제어 비선형 해석기법을 개발하였다. 본 논문에서 제안한 해석기법을 이용하여 철근콘크리트 원통형 구조물에 대하여 비선형 해석을 수행하여 한계압력과 한계압력 이후의 구조물의 거동을 예측하였으며 실험결과와 비교 검증하였다.

  • PDF

The Effect of Fiber Volume Fraction Non-uniformity through Thickness Direction on the Torsional Buckling Load of Cylindrical Composite Lattice Structure (두께방향 섬유체적비 불균일이 원통형 복합재 격자 구조의 비틀림 좌굴 하중에 미치는 영향)

  • Min-Hyeok Jeon;Hyun-Jun Cho;Yeon-Ju Kim;Mi-Yeon Lee;In-Gul Kim
    • Composites Research
    • /
    • v.36 no.2
    • /
    • pp.80-85
    • /
    • 2023
  • A cylindrical composite lattice structure is manufactured by filament winding. The distribution of nonuniform fiber volume fraction induced by the manufacturing process can be observed. The stiffness and buckling characteristics can be influenced by non-uniform fiber volume fraction. In this paper, the effect of non-uniform fiber volume fraction through thickness direction on the torsional buckling load of the cylindrical composite lattice structure was examined. The stiffness variation induced by the non-uniform fiber volume fraction was applied to the finite element model, and buckling analysis was performed. The variations of buckling load with variations of fiber volume fraction were compared. The non-uniform fiber volume fraction reduced the torsional buckling load of the composite lattice structure.

A Study of Heat Transfer in a Horizontal Ice Storage Tube - Inward Freezing Process with Volume Expansion of Ice - (수평 원통형 빙축열조에서의 열전달에 관한 연구 - 얼음의 부피 팽창을 고려하는 내향 응고 실험 -)

  • Lee, J.Y.;Kim, Y.K.;Cho, N.C.;Kim, Y.J.;Yim, C.S.
    • Solar Energy
    • /
    • v.15 no.1
    • /
    • pp.3-11
    • /
    • 1995
  • Heat transfer phenomena during inward freezing process of the water in a horizontal cylinder were experimentally studied. The cooling temperature of a wall more significantly affects the timewise average temperature than the initial superheating temperature of the water. In addition, it was absolved that the timewise average temperature was influenced by the initial volume ratio of the water($V_l/V_{tot}$) at the same temperature conditons. One the other hand, the freezing speed of the upper part in the water-ice interface was quickly progressed due to natural convection. Furthermore, experimental observation showed that the frozen mass fraction($M_s/M_{tot}$) was influenced by the initial volume ratio of the water($V_l/V_{tot}$). It was noted that the frozen mass fraction for each $V_l/V_{tot}$ represented by $Ste^*$ and Fo.

  • PDF

The Effect of the Fiber Volume Fraction Non-uniformity and Resin Rich Layer on the Rib Stiffness Behavior of Composite Lattice Structures (섬유체적비 불균일 및 수지응집층이 복합재 격자 구조체 리브의 강성도 거동에 미치는 영향)

  • Kang, Min-Song;Jeon, Min-Hyeok;Kim, In-Gul;Kim, Mun-Guk;Go, Eun-Su;Lee, Sang-Woo
    • Composites Research
    • /
    • v.31 no.4
    • /
    • pp.161-170
    • /
    • 2018
  • Cylindrical composite lattice structures are manufactured by filament winding process. The fiber volume fraction non-uniformity and resin rich layers that can occur in the manufacturing process affect the stiffness and strength of the structure. Through the cross-section examination of the hoop and helical ribs, which are major elements of the composite lattice structure, we observed the fiber volume fraction non-uniformity and resin rich layers. Based on the results of the cross-section examination, the stiffness of the ribs was analyzed through the experimental and theoretical approaches. The results show that the fiber volume fraction non-uniformity and resin rich layers have an obvious influence on the rib stiffness of composite lattice structure.

Partial Discharge Characteristics of Silicone Rubber for Insulators due to Appling Voltage Time (애자용 실리콘 고무의 전압인가시간에 따른 부분방전특성)

  • Kim, T.Y.;Lee, H.J.;Shin, H.T.;Lee, S.W.;Lee, C.H.;Hong, J.W.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1454-1456
    • /
    • 2003
  • 전기절연재로서의 성능이 우수하며, 다른 물질과의 결합 및 성형의 편리성 및 경량화에 부합할 수 있는 실리콘 고무의 사용이 급증하고 있다. 이에 본 논문에서는 현수애자에 사용중인 실리콘 고무를 선택하여 제조시에 발생할 수 있는 내부보이드에 대한 전기적특성을 알아보기 위해 실리콘 고무를 3층으로 적층하여 중간층 중심에 비슷한 체적으로 인공보이드를 원통 및 삼각기등형의 보이드를 제작하여 보이드형상 변화에 따른 부분방전전하량을 측정하였다. 위상(${\Phi}$)-전하량(q)-빈도(n)에 대한 데이터를 3차원그래프로 나타냈으며, 또한 평균방전전류 및 방전전력 변화를 통한 보이드 결함 특성을 파악하였다. 그 결과, 전압인가 시간에 따라 원통보이드의 경우 초기에는 방전전류 및 방전전력이 증가 하다가 일정시간이 경과하면 감소하는 형태를 나타냈으며, 삼각기둥보이드의 경우 계속적으로 증가하는 모습을 보여주었다.

  • PDF

Basic Analysis of Heat and Mass Transfer Characteristics of Tubular Membrane Humidifier for Proton Exchange Membrane Fuel Cell (이온교환막 연료전지용 원통형 막 가습기의 열 및 물질전달특성 기초 연구)

  • Bae, Ho-June;Ahn, Kook-Young;Lee, Young-Duk;Kang, Sang-Kyu;Yu, Sang-Seok
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.5
    • /
    • pp.473-480
    • /
    • 2011
  • The proton exchange membrane (PEM) fuel cell system is critically dependent on the humidity, which should be properly maintained over the entire operating range. A membrane humidifier is used for the water management in the PEMFC because of the membrane humidifier's reliable performance and zero parasitic power loss. In the PEMFC system, the membrane humidifier is required to provide appropriate humidity for the design point of the fuel cell. Although the performance of the fuel cell depends on the performance of the humidifier, few studies have provided a systematic analysis of the humidifier. We carry out an experimental analysis of the membrane humidifier using a vapor condensation bottle. The dry air pressure, water flow temperature, and air flow rate were chosen as the operating parameters. The results show that the time constant for the dynamic response of the membrane humidifier is relatively short, but additional analysis should be carried out.

Study on Effective Point of Measurement for Parallel Plate Type ionization Chamber with Different Spacing (평행평판형 이온함의 두 전극간의 간격 변화에 따른 유효측정점에 관한 연구)

  • 신교철;윤형근
    • Progress in Medical Physics
    • /
    • v.13 no.2
    • /
    • pp.55-61
    • /
    • 2002
  • In this work, EPM (effective point of measurement) of parallel plate ionization chamber with three different spacing were investigated. If the plate separation is less than 2 mm one generally assumes that the effective point of measurement is just behind the front window of the parallel plate ionization chamber. For chamber with relatively large separation, such as the ones used for very accurate exposure measurements, this assumption breaks down and the EPM depends on plate separation and thickness of the front window. For parallel plate chambers, conventional theoretical analyses suggest that the EPM is the inner front wall and that it shifts towards the geometric centre of the chamber as the plate separation increases. The PP-IC (parallel plate ionization chamber) is fabricated using acrylic plate for the chamber medium and printed circuit board for electrical configuration. The various sizes of the sensitive volumes designed so far are 0.9, 1.9, and 3.1 cc. The gap between two electrodes ranges from 3, 6, and 10mm. Also the charge-to-voltage converter is designed to collect the electrons produced in the ionization chamber cavity. As the result of our experiment, the EPM shift was within 0.6 mm in photon beams and 0.4 mm to 2.5 mm in electron beams for the plate separation of 6 mm and 10 mm. EPM shifts towards the geometric center of the chamber as the plate separation increases.

  • PDF

입구유속의 진폭이 층류유동에서 사각실린더 주위의 와류쉐딩과 공진현상에 미치는 영향에 관한 수치해석적 연구

  • 정영종;심석구;강신형
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1998.05a
    • /
    • pp.603-608
    • /
    • 1998
  • 유체내의 물체 주위에서 유동박리로 인해 생성되는 와류쉐딩은 열전달이나 물질전달을 촉진시키는 이점이 있으나, 항력을 증가시키거나 유동 및 온도의 요동에 의해 구조물을 손상시키는 단점이 있다. 특히 물체와 주위 유동 사이에 공진이 일어나면 항력값이 증가하면서 항력과 양력의 진폭이 급격히 증가하여 물체에 심각한 손상을 초래할 수 있다. 본 연구에서는 레이놀즈수 200 이하의 층류유동에서 공진시 물체 주위의 유동현상과 이로 인한 양력과 항력의 변화들을 수치해석방법을 통하여 분석하였다 수치해석은 일반좌표계에서 유한체적법을 적용하여 Navier-Stokes 방정식을 차분화하였다. 이때 방정식의 종속변수로는 공변속도를 채택하였으며, 이산화된 방정식은 분리단계법을 이용하여 수치해를 구하였다. 입구유속의 강제진동에 의한 사각실린더 주위의 와류쉐딩시 공진이 발생하는 강제진동수의 범위는 원통실린더의 경우와 유사하였으나 상대적으로 폭이 더 좁았다 그리고 공진이 발생하는 강제진동수의 범위는 진폭이 증가할수록 증가하였다. 쉐딩 진동수가 일정하면서 입구유속의 진폭이 증가하면 이에 비례하여 실린더 주위의 유속이 상대적으로 증가하게 되어 와도가 강해지면서 입추유속 진폭에 비례하여 항력의 평균값 뿐 아니라 항력과 양력의 진폭도 증가하였다. 그리고 실린더 뒷면의 와류 생성영역은 진폭에 비례하여 감소하였다. 진폭의 변화에 따라 상변화가 서로 상이한 것은 실린더 뒤쪽의 와류들이 상하면의 합력차이를 변화시켰고 이것이 진폭변화에 따라 상변화를 상이하게 나타나게 한 원인으로 진폭이 클수록 실린더 뒤쪽에서 압력변화가 심하게 변하면서 실린더 앞쪽까지 더 많은 영향을 미쳤기 때문이다.선원의 사용자에게 제공되는 최종방사능을 평가하는데 유용하게 사용될 수 있다.r의 분포를 보였다.cting the effect of earthquake on structures. This paper is based on the presented paper at the Bertero Symposium held in January 31an4 February 1 at Berkeley, California, USA which was entitled "Needs to Evaluate Real Seismic Performance of Buildings-Lessons from 1995 Hyogoken-Nambu Earthquake-". The lessons for buildings from the damage due to the Hyogoken-Nambu Earthquake are necessity to develop more rational seismic design codes based upon a performance-based design concept, and to evaluate seismic performance of existing buildings. In my keynote lecture at the Korean Association for Computational Structural Engineering, the history of seismic design and use of structural analysis in Japan, the lessons for buildings from the Hyogoken-Nambu Earthquake, the

  • PDF

Heat Transfer in Heat Storage System with P.C.M. -Experimental and Numerical Investigation during Inward Melting in a Vertical Tube- (상변화 물질을 사용한 축열조에서의 열전달 -수직원관내에서의 내향용융실험 및 수치해석-)

  • Yim, Chang-Soon;Choi, Guk-Gwang;Lee, Cha-Moon;Kim, Jun-Gun;Shong, Ha-Jin;Cho, Nam-Cheol
    • Solar Energy
    • /
    • v.10 no.1
    • /
    • pp.5-13
    • /
    • 1990
  • In the present investigation, experiments and numerical analysis during melting process of a phase change material were performed to research heat transfer phenomena generated by means of conduction and natural convection in the vertical tube at inward melting. The phase change material used in the experiments is 99 percent pure n-Docosane paraffin($C_{22}H_{46}$). In the results, it is found that the velocity of phase change interface at the top of tube is faster than at the bottom of tube because of the effect of natural convection, and the distribution of velocity at the liquid region is little affected by the initial temperature of phase change material. The velocity of phase change interface is slower as the initial temperature of phase change material is lower, and the effect of natural convection is larger as the aspect ratio of tube is larger. In tendency of heat transfer phenomena, the experimental results were well corresponded with numerical results. But there were a little disagrements between the results of experiment and numerical analysis because of the assumption of the constant volumetric expansion coefficient in numerical analysis.

  • PDF