• Title/Summary/Keyword: 원접촉

Search Result 705, Processing Time 0.031 seconds

Vacuum Web-coater with High Speed Surface Modification Equipment for fabrication of 300 mm wide Flexible Copper Clad Laminate (FCCL) (초고속 대면적 표면 처리 장치가 부착된 300 mm 폭 연성 동박적층 필림 제작용 진공 웹 코터)

  • Choi, H.W.;Park, D.H.;Kim, J.H.;Choi, W.K.;Sohn, Y.J.;Song, B.S.;Cho, J.;Kim, Y.S.
    • Journal of the Korean Vacuum Society
    • /
    • v.16 no.2
    • /
    • pp.79-90
    • /
    • 2007
  • Prototype of $800{\ell}$ vacuum web coater (Vic Mama) consisting of ion source with low energy less than 250 eV for high speed surface modification and 4 magnetron sputter cathodes was designed and constructed. Its performance was evaluated through fabricating the adhesiveless flexible copper clad laminate (FCCL). Pumping speed was monitored in both upper noncoating zone pumped down by 2 turbo pumps with 2000 l/sec pumping speed and lower surface modification and sputter zone vacuumed by turbo pumps with 450 1/sec and 1300 1/sec pumping speed respectively. Ion current density, plasma density, and uniformity of ion beam current were measured using Faraday cup and the distribution of magnetic field and erosion efficiency of sputter target were also investigated. With the irradiation of ion beams on polyimide (Kapton-E, $38{\mu}m$) at different fluences, the change of wetting angle of the deionized water to polyimide surface and those of surface chemical bonding were analyzed by wetting anglometer and x-ray photoelectron spectroscopy. After investigating the deposition rate of Ni-Cr tie layer and Cu layer was investigated with the variations of roll speed and input power to sputter cathode. FCCL fabricated by sputter and electrodeposition method and characterized in terms of the peel strength, thermal and chemical stability.

Classification of Frequently Occurring Disease by Chief Camplaints in Rural Area (농촌지역(農村地域) 주민(住民)에 빈발(頻發)하는 주소(主訴)를 중심(中心)으로 한 질병분류(疾病分類))

  • Kang, Seung-Won
    • Journal of Preventive Medicine and Public Health
    • /
    • v.12 no.1
    • /
    • pp.61-69
    • /
    • 1979
  • In Korea, the regional differences of medical facilities and man-powers are very serious recently. in order to solve rural medical problem, the comprehensive health care service is required earnestly in rural area. The present study was performed to provide the material for rural medical policy by analyzing the diseases occurring frequently in rural area and assuming the paramedical workers' abilities of medical treatment. The frequently by occurring diseases were classified by investigating. The chief complaints of 4559 subjects through home visiting for last weeks occurred in 1978. The paramedical workers' abilities of medical treatment were investigated by analyzing the clinical charts of patients treated by paramedical workers by systemic health care delivery system from, September 1977 to December 1977. The results obtained are summarized as fellows; 1. The rate of disease suffering recently for 2 weeks was 22.5% in Rural area. 2. The rate of respiratory disease was 36.%, gastrointestinal disease 18%, trauma 8% and neuromuscular disease 7.5%, respectively. 3. The coverage of treatment by health workers was 97.6% in general practitioner, 70% in community health practitioner and 42.1% in community health aid, respectively.

  • PDF

Study on the Standardization of a Surveillance Culture Laboratory in Infection Control Fields (감염관리 분야에서 감시배양검사의 표준화 연구)

  • Park, Chang-Eun;Jeong, Na-Yeon;Yang, Min-Ji;Kim, Han-Wool;Joo, Sei-Ick;Kim, Keon-Han;Seong, Hee-Kyung;Hwang, Yu-Yean;Lim, Hyun-Mi;Son, Jae-Cheol;Yoon, Sun-Han;Yoon, Nam-Seob;Jang, In-Ho
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.50 no.3
    • /
    • pp.359-369
    • /
    • 2018
  • An essential measure to prevent healthcare-associated infections (HAI) is to develop a consistent system of surveillance, thereby promoting a reliable situation diagnosis to perform efficient control for the problem. Patient-to-patient transmission of pathogens within the hospital plays a substantial role in the epidemiology of HAIs. Contamination of healthcare environments commonly occurs, including facilities surfaces (e.g., bed rails, bedside tables), drinking water, cooling tower water, endoscopic instruments, food, airborne, endotoxin test, sterile test and medical equipment, with pathogenic organisms. In addition, epidemiological analysis is performed by multi locus sequence tying, pulsed-field gel electrophoresis for active surveillance. Therefore, an environmental surveillance culture test for prevention improves patient safety and blocks infection agents. Effective infection control and increased safety are possible by controlling the national infection control system. In conclusion, this study contributes to an effective infection control system through the standardization of active surveillance culture laboratory and secure expertise as infection control specialist. The primary objective of the standardization is to improve the safety of the nation's healthcare system by reducing the rates of HAIs.

Advanced Indoor Location Tracking Using RFID (RFID를 이용한 개선된 실내 위치 추적)

  • Joo, Won-lee;Kim, Hyo-Sun;Jung, Yeong-Ah;Hong, Yeon-Chan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.1
    • /
    • pp.425-430
    • /
    • 2017
  • RFID is a technology that uses radio frequency to read information in tags attached to objects or people. Because it reads the information without contact when tracking the location using tags in a RFID system, there can be errors between the actual position and measured position. In this paper, three methods (the method of radiation pattern, the method of the median value, and the method using both the radiation pattern and median value) are proposed to identify the location of objects or people using the RFID technique. The location identification system based on RFID was constructed and tags were arranged in a square pattern. The real location and experimentally predicted location of an object containing a reader were compared to confirm the error. Instead of the existing papers that obtained the approximately location of a reader by calculating the center of gravity of all tags read by that reader, in this study, the predicted location was obtained by the median value and the radiation pattern. This study validated which method was the most efficient among the three methods proposed in this paper through the data of the read tags. As a result, the method of the median value had the smallest error among those assessed.

Improvement of the Adhesion Properties between Aluminum and a Parylene-C Film by Using the Duoplasmatron Ion Source (Duoplasmatron Ion Source를 이용한 Parylene과 Al의 접착력 향상에 관한 연구)

  • Choi, Sung-Chang
    • Journal of the Korean Vacuum Society
    • /
    • v.21 no.2
    • /
    • pp.78-85
    • /
    • 2012
  • In order to improve the adhesion between poly-monochloro-para-xylylene (Parylene-C) film and Aluminum thin film, the surface of Parylene-C film was irradiated by ${O_2}^+$ and $Ar^+$ ion beam generated by duoplamatron ion source. The ion dose of $Ar^+$ and ${O_2}^+$ was changed from $5{\times}10^{14}$ to $1{\times}10^{17}/cm^2$ and the ion beam energy was 1 kV. Contact angles of water on Parylene-C modified by $Ar^+$ and ${O_2}^+$ ion irradiation decreased from $78^{\circ}$ to around $17^{\circ}$, and $9^{\circ}$, respectively. X-ray photoelectron spectroscopy analysis shows that the hydrophilic groups were formed on the surface of Parylene-C by chemical reaction between the unstable chains induced by the ion irradiation and oxygen ions or residual oxygen gas. The hydrophilic groups were identified as C-O bond, C=O bond and (C=O)-O bond. The cross cut tape test which was applied to characterize the adhesion between Al thin film and Parylene-C film modified by ${O_2}^+$ ions irradiation shows that the adhesion strength was improved as increasing ion dose.

Noise Analysis and Measurement for a CW Bio-Radar System for Non-Contact Measurement of Heart and Respiration Rate (호흡 및 심박수 측정을 위한 비접촉 방식의 CW 바이오 레이더 시스템의 잡음 분석 및 측정)

  • Jang, Byung-Jun;Yook, Jong-Gwan;Na, Won;Lee, Moon-Que
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.19 no.9
    • /
    • pp.1010-1019
    • /
    • 2008
  • In this paper, we present a noise analysis and measurement results of a bio-radar system that can detect human heartbeat and respiration signals. The noise analysis including various phase noise effects is very important in designing the bio-radar system, since the frequency difference between the received signal and local oscillator is very small and the received power is very low. All of the noise components in a bio-radar system are considered from the point of view of SNR. From this analysis, it can be concluded that the phase noise due to antenna leakage is a dominant factor and is a function of range correlation. Therefore, the phase noise component with range correlation effect, which is the most important noise contribution, is measured using the measurement setup and compared with the calculated results. From the measurement results, our measurement setup can measure a closed-in phase noise of a free-running oscillator. Based on these results, it is possible to design a 2.4 GHz bio-radar system quantitatively which has a detection range of 50 cm and low power of 1 mW without additional PLL circuits.

Non-extraction treatment in Class III malocclusion by using improved superelastic NiTi wire (III급 부정교합 환자에서 초탄성 Ni-Ti alloy wire를 이용한 비발치 치료)

  • Min, Sam;Chung, Chu-Ryung;Hwang, Chung-Ju;Cha, Jung-Yul
    • The korean journal of orthodontics
    • /
    • v.41 no.4
    • /
    • pp.297-306
    • /
    • 2011
  • Nonextraction camouflage treatment in mild Class III malocclusion is achieved by backward movement of the lower dentition and forward movement of the upper dentition. Many camouflage treatment modalities have been used for distal tipping and distal movement of mandibular posterior teeth. The amount of distal movement of mandibular dentition can be improved in cases of severe crowding, even without the patient's cooperation, by using miniscrews for anchorage. However, miniscrew insertion may be unsuccessful, and it may contact the adjacent root because of the distal movement of dentition. Distal tipping of mandibular dentition can be achieved using multiloop edgewise archwires and intermaxillary elastics. However, the complexity of this wire design causes discomfort to patients. Recently, a new treatment using improved superelastic NiTi wires (ISWs) and intermaxillary elastics has been introduced. ISWs can deliver orthodontic force more effectively, and their use with molar tip-back treatment has several advantages-this approach is effective, simple, and easy to use and reduces patient discomfort. The aim of this study was to report a case of camouflage treatment using ISW with tip-back and intermaxillary elastics for distal tipping of mandibular posterior dentition and to evaluate the effectiveness of this treatment in a clinical setting.

Three-dimensional finite element analysis according to the insertion depth of an immediately loaded implant in the anterior maxilla (상악 전치부 즉시하중 임플란트의 식립 깊이에 따른 삼차원 유한요소 분석)

  • Park, Cheol-Woo;Kim, Sung-Hun;Yeo, In-Sung;Yoon, Hyung-In;Han, Jung-Suk
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.2
    • /
    • pp.105-113
    • /
    • 2018
  • Purpose: The purpose of this study was to investigate the effects of the insertion depth of an immediately loaded implant on the stress distribution of the surrounding bone and the micromovement of the implant using the three-dimensional finite element analysis. Materials and methods: A total of five bone models were constructed such that the implant platform was positioned at the levels of 0.00 mm, 0.25 mm, 0.50 mm, 0.75 mm, and 1.00 mm depth from the crest of the cortical bone. A frictional coefficient of 0.3 and the insertion torque of 35 Ncm were simulated on the interface between the implant and surrounding bone. A static load of 178 N was applied to the provisional prosthesis with a vertical load in the axial direction and an oblique load at $30^{\circ}$ with respect to the central axis of the implant, then a finite element analysis was performed. Results: The implant insertion depth significantly affected the stress distribution on the surrounding bone. The largest micromovement value of the implant was $39.34{\mu}m$. The oblique load contributed significantly to the stress distribution and micromovement in comparison to the vertical load. Conclusion: Increasing the implant insertion depth was advantageous in dispersing the concentrated stress in the cortical bone and did not significantly affect the micromovement associated with early osseointegration failure.

Studies on the Preservative Condition and the Ultrastructure of Hair of Newly Found Sixteenth Century Mummy in Paju (파주에서 발견된 16세기 미라 머리카락의 미세구조과 보존상태에 관한 연구)

  • Lee, Gwi-Yeong;Chang, Byung-Soo
    • Applied Microscopy
    • /
    • v.35 no.4
    • /
    • pp.24-31
    • /
    • 2005
  • The preservative condition and ultrastructure on the mummified hair collected from newly found female mummy in Paju, were investigated by using scanning and transmission electron microscopes. The female mummy was found in september, 2002 during the traditional reburial process for the buried ones. The hair of 16th century mummy showed very intact appearances during observation with electron microscope. And the structures of the cortex, medulla and cuticle were well preserved. The cuticle layer was easily discernable, which are composed of six to seven cuticular cells. Each cuticular cells surrounded and thus seperated from its neighbors by intercellular membrane complex. In the cortex, many macrofibrils and some melanin granules between them were observed. We observed well preserved rod form macrofibrils running parallel along the direction of hair shaft. Especially, melanin granules were aggregated in the cortex which was adjacent to the cuticlu layer. As to the cause for the well-preservation of 440 year old hair sample, the presence of surface coat on the hair, which are composed of various materials. As calcium was included in the surface coat in Electron Dispersive X-ray Spectroscopy (EDS), the hardening process of the surface coat by calcium might inhibit the water or microorganism infiltration into the hair.

The Private Security Officer ' Actual Condition of First-Aid Education (민간경비원의 응급처치 교육에 대한 실태조사)

  • Kim, Hyun-Ho;Kang, Hyeon
    • Korean Security Journal
    • /
    • no.51
    • /
    • pp.275-290
    • /
    • 2017
  • Since the establishment of Security Business Act in 1976, the Korean private security industry has rapidly grown in the qualitative and quantitative aspects. In the circumstance, various roles of private security guards have been demanded. A private security guard as the first contactor of the users of multi-use facilities should first find an accident field situation and make a response when an accident occurs, and should give first aid as most as possible until emergency medical workers arrive. However, there is a lack of first-aid education for the private security guards who are responsible for the safety of facility users. Therefore, the purpose of this study is first to find how many times private security guards have job and first-aid education, and analyze how the education count influences their first-aid ability; secondly to analyze how private security guards' satisfaction with first-aid education influences their first-aid ability. To achieve the purpose, this researcher conducted a questionnaire survey on first-aid ability of the private security guards working in the metropolitan areas. For data analysis, Stata se/ 14.0ver was applied. For the analysis on validity and reliability, exploratory factor analysis was conducted and a Cronbach's a value was drawn. To find the actual conditions of first-aid education, frequency analysis, inter-group difference analysis, and multi-regression analysis were conducted. According to the data analysis, there were not enough times of job education and first-aid education for private security guards, and their satisfaction with first-aid education and first-aid ability were difference depending on the job and first-aid education counts. Also, their satisfaction with first-aid education partially influenced their first-aid ability.