A Study on the Nonlinear Analysis of Containment Building in Korea Standard Nuclear Power Plant (한국형 원전 격납건물의 비선형해석에 관한 연구)

  • Lee, Hong-Pyo;Choun, Young-Sun;Lee, Sang-Jin
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.20 no.3
    • /
    • pp.353-364
    • /
    • 2007
  • In this paper, a nonlinear finite element analysis program NUCAS, which has been developed for assessment of ultimate pressure capacity and failure mode for nuclear containment building is described. Degenerated shell element with assumed strain method and low-order solid element with enhanced assumed strain method is adapted to microscopic material and elasto-plastic material model, respectively. Finally, the performance of the developed program is tested and demonstrated with several examples. From the numerical tests, the present results show a good agreement with experimental data or other numerical results.

한국형 표준원전 화재사건에 대한 2단계 PSA 불확실성 분석

  • 김시달;안광일;박수용;김동하;진영호
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1998.05a
    • /
    • pp.881-886
    • /
    • 1998
  • 한국형 표준 원진(울진 원전 3,4호기)화해 사건에 대한 2 단계 확률론적 안전성평가 (Level 2PSA) 에서 격납건물 파손모드에 큰 영향을 준다고 판단되는 현상들에 대한 불확실성 분석을 수행하였다. 불확실성 분석 대상은 주로 민감도분석 및 기존 2단계 PSA수행결과 중요한 인자로 선정된 8가지 주요 현상들로 국한하였다. 수행 방법은 성층화 추출방식 (Latin Hypercube Sampling)으로부터 발생된 1000개의 표본을 사용하였고, 분석결과는 두가지 불확실성 측도로 제시하였으며, 사용된 코드는 2 단계 PSA 분석용 전산코드인 CONPAS 이다. 불확실성 관리측면에서. 제일 불확실성이 높은 격납건물 파손모드인 원자로 공동바닥관통의 불확실성 인자를 줄이기 위해서는 CR-EJECT 현상에 대한 불확실성 을 줄여야 할 것이다.

  • PDF

저온 용융 합금물을 이용한 울진 1,2호기 원전 캐비티에 대한 노심용융물 고압분출 실험 연구

  • 박래준;김상백;김희동;김찬수;이규정
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1998.05a
    • /
    • pp.783-788
    • /
    • 1998
  • 국내 프랑스 가압경수형 원전인 울진 1,2호기 캐비티의 격납건물 직접가열에 대한 특성을 분석하기 위하여 노심용융물 고압분출 실험을 수행하였다. 본 연구에서는 환형통로 면적과 파손 직경에 따라 원자로용기 압력을 변화시키면서 용융물을 저온 용융 합금물인 Wood's Metal, 증기를 질소기체로 각각 모의하여 실험을 수행하였으며, 실험 결과는 물을 용융물 상사물로 사용한 전년 실험 결과(1)와 비교.분석하였다. 실험결과, 밀도가 물보다 큰 저온 용융 합금물을 사용한 경우는 물을 사용한 실험결과보다 밀도와 용융물의 벽면 고화고착 때문에 격납건물로 방출되는 용융물 양이 적게 나타났다. 물을 상사물로 사용한 경우와 같이 노심 용융물 고압분출에는 원자로 용기 파손직경이 많은 영향을 미치고 환형통로 면적은 큰 영향을 미치지 않는 것으로 나타났다. 노심용융물 고압분출 실험에 중요한 영향을 미치는 실험 상사물의 밀도와 용융물의 벽면 고화부착에 대해서는 종합적으로 분석하는 추가 연구가 필요하다.

  • PDF

Assessment of the Internal Pressure Fragility of the CANDU Type Containment Buildings using Nonlinear Finite Element Analysis (비선형 유한요소해석을 이용한 CANDU형 격납건물의 내압취약도 평가)

  • Hahm, Dae-Gi;Choi, In-Kil;Lee, Hong-Pyo
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.23 no.4
    • /
    • pp.445-452
    • /
    • 2010
  • In this paper an assessment of the internal pressure fragility of the CANDU type containment buildings is performed. The uncertainties of the performance of the containment buildings, material properties and tendon characteristics are referred from the in-service reports of Wolsung Unit 1. The containment buildings are modeled as a three-dimensional finite elements with considering the major opening and penetrations. A new method to evaluate the probabilistic fragility of the massive structural system is developed. The fragility curves of the target containment building are presented with repect to the failure modes and reliability levels. The center of wall is reveled as the most weak structural component of the containment building in the sense of the rupture and catastrophic rupture failure modes.

Development of Analysis Tool for Structural Behavior of Domestic Containment Building with Grouted Tendon (CANDU-type) (국내 부착식 텐던 격납건물(CANDU형)의 구조거동 분석 도구 개발)

  • Lee, Sang-Keun;Song, Young-Chul
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.5A
    • /
    • pp.901-908
    • /
    • 2006
  • The structural integrity of containment building in Nuclear Power Plants has to be verified by the ISI(In Service Inspection) because there are some variations on the structural behavior of it due to the change of the physical properties of concrete and tendon with the lapse of time. In this study, the program 'SAPONC-CANDU' which can monitor and analyze the structural behavior of the containment building with grouted tendon (CANDU-type, 'Wolsong unit-2, 3, and 4' in Korea) was developed. This program is based on the algorithm which can calculate the prediction values of the quantities of strain variation for the vibrating-wire strain gauges embedded into the concrete of the containment building under temperature and time dependent factors which are creep, shrinkage, and prestressing force. The readings of the strain gauges are used as input data for the operation of the program. And it finally provides graphically a prediction value, line and band of the quantity of strain variation for the respective strain gauges, therefore, it is thought that the site engineers are able to assess the structural integrity of the domestic containment building with grouted tendon with easy using this program.

Analysis of EQ pH Condition and Fission Product Removal Capability for Nuclear Power Plant (원전의 내환경기기검증 화학환경 및 핵분열생성물 제거능력 평가)

  • Song, Dong Soo;Ha, Sang Jun;Seong, Je Joong;Jeon, Hwang Yong;Huh, Seong Cheol
    • Journal of Energy Engineering
    • /
    • v.23 no.3
    • /
    • pp.186-190
    • /
    • 2014
  • Nuclear Power Plants require the control ability of chemical condition (pH) because pH control during transient accident such as LOCA makes an able the fission product removal capability to be maintained, stress corrosion cracking of stainless steel equipment to be prevented and the production of hydrogen by aluminum and zinc to be minimized. An NPP is designed to control the pH of containment spray and sump coolant using the spray additives 30% NaOH in the event of loss of coolant accident. In this paper, the pH of sump coolant of an NPP during LOCA was analyzed and the fission products removal constant and decontamination factor were calculated according to Standard Review Plan 6.5.2 related to spray chemical conditions of pH. The calculated pH value of recirculation mode using the computer code corresponds to 8.09~9.67, which meets the chemical environment regulation requirements. The fission product removal capability caused by containment spray system is performed to provide input to radiation analysis.

Overview of In-Vessel Retention Concept With Application to an Advanced Pressurized Water Reactor-Design (용기내부보존 개념의 조감 : 신형가압경수로원전-설계적용의 관점에서)

  • 김성호
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1997.05a
    • /
    • pp.592-599
    • /
    • 1997
  • 중대사고관리 전략의 하나로서 피동형-설계에 적용되고 있는 용기내부보존(IVR)기념 - 이 논문에서는 실제적으로 원자로 압력용기벽 외부냉각(ERVC)방법을 사용한다 -이 규제측면에서는 용융물의 냉각가능성 쟁점의 해결이라는 문맥에서 조감되었다; 기술측면에서는 IVR개념의 신빙성 및 유융성이 언급되었다. 덧붙여서, 이 ERVC방법들이 개량형-설계에 적용되기 위하여 요구되는 점들이 규제측면과 기술측면에서 각각 검토되었다. 이 검토결과의 바탕위에서 용융물 냉각가능성/급냉가능성의 쟁점과 관련하여 전력연구원(KEPRI) 신형원전개발센타(CARD)에서 개발중인 한국차세대원전(KNGR)-설계에서 선택될 수 있는 대안적 전략들이 제안되었다: (1) 전략1A: 젖은공동방법의 신빙성에 기반을 두는 것; (2) 전략1B: 젖은공동방법/격납건물건전성에 기반을 두는 것; (3) 전략2A : ERVC방법의 신빙성에 기만을 두는 것, (4)전략2B: ERVC방법/격납 건물건전성의 균형된 접근법에 기반을 두는 것. 마지막으로, 신형-설계적용의 관점에서 각각 규제측면과 기술측면에서 본 현황파악 및 대책마련의 권고사항이 제시되었다.