• Title/Summary/Keyword: 원전기기

Search Result 295, Processing Time 0.021 seconds

A Shaking Table Test for an Re-evaluation of Seismic Fragility of Electrical Cabinet in NPP (원전 전기캐비넷의 지진취약도 재평가를 위한 진동대 실험)

  • Kim, Min-Kyu;Choi, In-Kil
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.24 no.3
    • /
    • pp.295-305
    • /
    • 2011
  • In this study, a seismic behavior of electrical cabinet system in Nuclear Power Plants(NPPs) was evaluated by the shaking table test. A 480V Motor Control Centers(MCCs) was selected for the shaking table test, and a real MCC cabinet for the Korea Nuclear Power Plant site was rented by manufactured company. For the shaking table tests, three kinds of seismic input motions were used, which were a US NRC Reg. guide 1.60 design spectrum, a UHS spectrum and PAB 165' floor response spectrum(FRS). Especially, the UHS input motion was selected for an evaluation of structural seismic amplification effects, three directional accelerations were measured at three points outside on the cabinet system and also that of the incabinet response amplification, accelerations were measure at two points which were mounted in electrical equipment such as relay. Seismic amplification effect is determined at the outside and inside of a cabinet as input seismic motion, and compared to the results which are calculated by analytical method based on NUREG/CR-5203.

Safety Evaluation on Real Time Operating Systems for Safety-Critical Systems (안전필수(Safety-Critical) 시스템의 실시간 운영체제에 대한 안전성 평가)

  • Kang, Young-Doo;Chong, Kil-To
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.10
    • /
    • pp.3885-3892
    • /
    • 2010
  • Safety-Critical systems, such as Plant Protection Systems in nuclear power plant, plays a key role that the facilities can be operated without undue risk to the health and safety of public and environment, and those systems shall be designed, fabricated, installed, and tested to quality standards commensurate with the importance of the functions to be performed. Computer-based Instrumentation and Control Systems to perform the safety-critical function have Real Time Operating Systems to control and monitoring the sub-system and executing the application software. The safety-critical Real Time Operating Systems shall be designed, analyzed, tested and evaluated to have capability to maintain a high integrity and quality. However, local nuclear power plants have applied the real time operating systems on safety critical systems through Commercial Grade Item Dedication method, and this is the reason of lack of detailed methodology on assessing the safety of real time operating systems, expecially to the new developed one. This paper presents the methodology and experiences of safety evaluation on safety-critical Real Time Operating Systems based upon design requirements. This paper may useful to develop and evaluate the safety-critical Real Time Operating Systems in other industry to ensure the safety of public and environment.

Effects of the Questionnaire and Radioactivity Measurement of Fishery from the Fukushima Nuclear Disaster (후쿠시마 원자력 재해 이후 수산물의 방사능 측정 및 설문 조사)

  • Kim, Myung Jun;Kang, Seok Min;Kweon, Dae Cheol
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.1
    • /
    • pp.53-58
    • /
    • 2016
  • March 11, 2011 Fukushima nuclear power plant accident has occurred, the last four years, his is the current state of anxiety remains on the consumer. Therefore, 2015 the current progress continues to have continued research for the purpose of resolving the insecurity of fishery in the country. We measured the radiation of the origin of fishery products, by 2015, research was carried out through a number of references to get additional data or studies that influence this to some degree. Create a consumer and one for the seller for the survey to find out the thoughts of both consumers and sellers on fisheries was to create the statistics by direct survey in 2014 year survey meter using PM1405 equipment dynamics of several species of aquatic origin in accordance with the (Taiwan, China, Russia), mackerel, pomfret, hairtail, saury, shrimp, squid measurements of radiation were investigated. The measurement in 2014 was $0.043{\sim}0.073{\mu}Sv/h$. The seller influenced the survey (90%) on fishery products sales, consumer safety, without this fishery (90%), radioactive contamination very high (28%) and the polarization was not as nearly 72%. The study of the stability of the radiation determined by the radiation levels of the aquatic marine products in a comparison the radiation levels result was determined in ICRP below the standard value (1 mSv/y).

Sampling-based Approach for Seismic Probabilistic Risk Assessment (지진 확률론적 리스크 평가를 위한 샘플링기반 접근법)

  • Kwag, Shinyoung;Eem, Seunghyun;Park, Junhee;Choi, In-Kil
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.33 no.2
    • /
    • pp.129-136
    • /
    • 2020
  • In this study, we develop a sampling-based seismic probabilistic risk assessment (SPRA) quantification technique that can accurately consider a partially dependent condition of component seismic fragility information. Specifically, the SPRA quantification method is proposed by combining the advantages of two representative methodologies: EPRI seismic fragility and JAERI seismic fragility input-based quantification. The most important feature of the proposed method is that it performs a SPRA using a sampling technique by transforming the EPRI seismic fragility input into JAERI seismic fragility input. When the proposed sampling-based approach was applied to an example of simple system and to a SPRA problem of a nuclear power plant, it was observed that the proposed method yields approximately similar system seismic fragility and seismic risk results as those of the exact solution. Therefore, it is believed that the approach proposed in this study can be used as a useful tool for accurately assessing seismic risks, considering the partial seismic dependence among the components; the existing SPRA method cannot handle such partial dependencies.

Aspect of the chief of state guard EMP (Electro Magnetic Pulse) protection system for the consideration (국가원수 경호적 측면에서의 EMP(Electro Magnetic Pulse) 방호 시스템에 대한 고찰)

  • Jung, Joo-Sub
    • Korean Security Journal
    • /
    • no.41
    • /
    • pp.37-66
    • /
    • 2014
  • In recent years, with the development of computers and electronics, electronics and communication technology in a growing and each part is dependent on the cross-referencing makes all electronic equipment is obsolete due to direct or indirect damage EMP. Korea and the impending standoff North Korea has a considerable level of technologies related to the EMP, EMP weapons you already have or in a few years, the development of EMP weapons will complete. North Korea launched a long-range missile and conducted a nuclear test on several occasions immediately after, when I saw the high-altitude nuclear blackmail has been strengthening the outright offensive nuclear EMP attacks at any time and practical significance for the EMP will need offensive skills would improve. At this point you can predict the damage situation of Korea's security reality that satisfy the need, more than anything else to build a protective system of the EMP. The scale of the damage that unforeseen but significant military damage and socio-economic damage and fatalities when I looked into the situation which started out as a satellite communications systems and equipment to attack military and security systems and transportation, finance, national emergency system, such as the damage elsewhere. In General, there is no direct casualties reported, but EMP medical devices that rely on lethal damage to people who can show up. In addition, the State power system failure due to a power supply interruption would not have thought the damage would bring State highly dependent on domestic power generation of nuclear plants is a serious nuclear power plant accident in the event of a blackout phenomenon can lead to the plant's internal problems should see a forecast. First of all, a special expert Committee of the EMP, the demand for protective facilities and equipment and conduct an investigation, he takes fits into your budget is under strict criteria by configuring the contractors should be sifting through. He then created the Agency for verification of performance EMP protection after you have verified the performance of maintenance, maintenance, safety and security management, design and construction company organized and systematic process Guard facilities or secret communications equipment and perfect for the EMP, such as protective equipment maneuver system should take.

  • PDF