• Title/Summary/Keyword: 원자로 재료

Search Result 543, Processing Time 0.028 seconds

The Structural, Electrical, and Optical Properties of ZnO Ultra-thin Films Dependent on Film Thickness (ZnO 초박막의 두께 변화에 따른 구조적, 전기적, 광학적 특성 변화 연구)

  • Kang, Kyung-Mun;Wang, Yue;Kim, Minjae;Lee, Hong-Sub;Park, Hyung-Ho
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.26 no.2
    • /
    • pp.15-21
    • /
    • 2019
  • We investigated the structural, electrical and optical properties of zinc oxide (ZnO) ultra-thin films grown at $150^{\circ}C$ by atomic layer deposition (ALD). Diethylzinc and deionized water were used as metal precursors and reactants, respectively, for the deposition of ZnO thin films. The growth rate per ALD cycle was a constant 0.21 nm/cycle at $150^{\circ}C$, and samples below 50 cycles had amorphous properties due to the relatively thin thickness at the initial ALD growth stage. With the increase of the thickness from 100 cycles to 200 cycles, the crystallinity of ZnO thin films was increased and hexagonal wurtzite structure was observed. In addition, the particle size of the ZnO thin film increased with increasing number of ALD cycles. Electrical properties analysis showed that the resistivity value decreased with the increase of the thin film thickness, which is correlated with the decrease of the grain boundary concentration in the thicker ZnO thin film due to the increase of grain size and the improvement of the crystallinity. Optical characterization results showed that the band edge absorption in the near ultraviolet region (300 nm~400 nm) was increased and shifted. This phenomenon is due to the increase of the carrier concentration with the increase of the ZnO thin film thickness. This result agrees well with the decrease of the resistivity with the increase of the thin film thickness. Consequently, as the thickness of the thin film increases, the stress on the film surface is relaxed, the band gap decreases, and the crystallinity and conductivity are improved.

Study on Chemical Decontamination Process Based on Permanganic Acid-Oxalic Acid to Remove Oxide Layer Deposited in Primary System of Nuclear Power Plant (계통 내 침적된 산화막 제거를 위한 과망간산/옥살산 기반의 화학제염 공정연구)

  • Kim, Chorong;Kim, Haksoo
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.17 no.1
    • /
    • pp.15-28
    • /
    • 2019
  • In accordance with the decommissioning plan for the Kori Unit 1 NPP, the reactor coolant system will be chemically decontaminated as soon as possible after permanent shutdown. This study developed the chemical decontamination process though the development project of decontamination technology of reactor coolant system and dismantled equipment for NPP decommissioning, which has been carried out since 2014. In this study, Oxidation/reduction process was conducted using system decontamination process development equipment of lab scale and was divided into unit and continuous processes. The optimal process time was derived from the unit process, and decontamination agent and the number of process were derived through the continuous processes. Through the unit process, the oxidation process took 5 hours and the reduction process took 4 hours. As optimum decontamination agent, the oxidizing agent was $200mg{\cdot}L^{-1}$ Permanganic acid + $200mg{\cdot}L^{-1}$ Nitric acid and the reducing agent was $2000mg{\cdot}L^{-1}$ Oxalic acid. In the case of the number of processes, all oxide films were removed during the two-cycle chemical decontamination process of STS304 and SA508. In the case of Alloy600, all oxide films were removed when chemical decontamination was performed for three cycles or more.

Evaluation of Metal Composite Filaments for 3D Printing (3D 프린팅용 금속 입자 필라멘트의 물성 및 차폐 능력 평가)

  • Park, Ki-Seok;Choi, Woo-Jeon;Kim, Dong-Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.5
    • /
    • pp.697-704
    • /
    • 2021
  • It is hard to get Filaments which are materials of the 3D printing Fused Deposition Modeling(FDM) method as radiation shielding in Korea. and also related research is insufficient. This study aims to provide basic data for the development of radiation shields using 3D printing by evaluating the physical properties and radiation shielding capabilities of filaments containing metal particles. after selecting five metal filaments containing metal particle reinforcement materials, the radiation shielding rate was calculated according to the Korean Industrial Standard's protective equipment test method to evaluate physical properties such as tensile strength, density, X-ray Diffraction(XRD), and weight measurement using ASTM's evaluation method. In the tensile strength evaluation, PLA + SS was the highest, ABS + W was the lowest, and ABS + W is 3.13 g/cm3 which value was the highest among the composite filaments in the density evaluation. As a result of the XRD, it may be confirmed that the XRD peak pattern of the particles on the surface of the specimen coincides with the pattern of each particle reinforcing material powder metal, and thus it was confirmed that the printed specimen contained powder metal. The shielding effect for each 3D printed composite filament was found to have a high shielding rate in proportion to the effective atomic number and density in the order of ABS + W, ABS + Bi, PLA+SS, PLA + Cu, and PLA + Al. In this study, it was confirmed that the metal particle composite filament containing metal powder as a reinforcing material has radiation shielding ability, and the possibility of using a radiation shielding filament in the future.

Study on the Morphologies and Electrical Properties in Polymer Blend Thin-Films Based on Two Poly(3-hexylthiophene) Conjugated Polymers with Different Regio-regularities (서로 다른 위치 규칙성을 가지는 두 개의 Poly(3-hexylthiophene) 공액 고분자를 기반으로 한 고분자 복합 박막의 구조와 전기적 특성에 대한 연구)

  • Ganghoon Jeong;Nann Aye Mya Mya Phu;Rae-Su Park;Jeong Woo Yun;Yeongun Ko;Mincheol Chang
    • Composites Research
    • /
    • v.36 no.5
    • /
    • pp.349-354
    • /
    • 2023
  • Poly(3-hexylthiophene) (P3HT) is a conjugated polymer that is highly soluble in organic solvents and is readily available. However, its electrical properties as an active channel in electronic devices are not enough for practical applications, necessitating further improvement in the properties. In this study, we demonstrate that the blending of two P3HT polymers (i.e., regio-regular (RR) P3HT and regio-random (RRa) P3HT) with different regioregularities can significantly improve charge transport characteristics of the blend films. The morphological and electrical properties of the blend films were systematically investigated by varying the ratio between two P3HT polymers. Atomic force microscopy (AFM), X-ray diffraction (XRD), and UV-visible absorption spectroscopy (UV-vis) were employed to evaluate the morphological and optoelectronic properties of the blend films. The crystallinity of the blend films increased with increasing the content of RRa-P3HT to 20 wt% and gradually decreased as the content increased to 80%. Consistently, the highest charge carrier mobility was obtained from the blend films containing 20 wt% RRa-P3HT, which value was measured to be 0.029 cm2/V·s. The values gradually decreased to 0.0007 cm2/V·s with increasing the content of RRa-P3HT to 80 wt%.

The Changes in the Electrical Properties of $\textrm{BaTiO}_3$-based PTCR Materials due to the addition of (Ca, Sr)$\textrm{TiO}_3$ ($\textrm{TiO}_3$첨가에 의한 $\textrm{BaTiO}_3$계 PTCR 물질의 전기적 특성변화에 대한 연구)

  • Joo, Ji-Won;Kim, Jong-Hwan;Kim, Hwan;Park, Soon-Ja
    • Korean Journal of Materials Research
    • /
    • v.7 no.4
    • /
    • pp.347-353
    • /
    • 1997
  • BaTiO$_{3}$물질은 뛰어난 유전체로 널리 알려져 왔으며 특히 Heywang등이 제안한 PTCR특성은 이 물질의 응용범위를 세라믹 필터, 회로보호소자, 온도감지소자 및 저항가열장치 등으로 확대시켰다. 이러한 특성의 발현기구는 아직까지 밝혀지지 않은 상태이지만 제 특성을 향상시키기 위한 노력은 계속되어왔다. 특히 개발목적에 맞게 온도에 따른 정저항 특성(PTCR; Positive temperature constnat of resistivity phenomena)을 설계하려는 시도가 계속되어 왔으며 그 중에서도 페로브스카아트계의 2가와 4가의 양이온 자리를 등가나 원자가가 다른 양이온으로 치환하여 특성을 개선하려는 시도가 계속되어 왔다. 특히 $Ca^{2+}$나 Sr$^{2+}$$Ba^{2+}$자리를 치환할 수 있는 물질로 개별적인 첨가에 대한 연구는 많은 연구자들에 의해 진행된 상태이지만 최종적인 영향이나 해석에 대해서는 연구자들간에 이견이 많은 상태이다. 이번 실험에서는 BaTiO$_{3}$계에 합성한 (Ca, Sr)TiO$_{3}$를 Ca와 Sr의 상대적인 비를 변화시키면서 전체적인 첨가량을 변화시켜 그에 따른 전기적 특성 및 미세구조를 살펴보았다. (Ca, Sr)TiO$_{3}$의 첨가로 상온저항 및 PTCR특성을 변화시킬 수 있었으며 이를 통해 PTCR물질의 활용범위를 넓힐 수 있는 발판을 마련할 계기가 되었다. 특히 기존의 연구가 주로 개별적인 Ca나 Sr의 첨가에 의한 미세구조와 전기적 특성변화의 연구에 치중해 있었던 것과는 달리 Sr과 Ca을 함께 치환하여 상대적인 비가 특성에 더 중요한 영향을 끼치는 것을 확인하였으며 적절한 합성비를 선택하면 퀴리온도에서의 저항변화폭을 유지하면서 상온저항을 낮출 수 있음을 확인하였다.문했던 연구소인 Shanghai Research Center of Biotechnology, Shanghai Institute of Industrial Microbiology 및 Scientific Research Institute of Food and Fermentation Industry을 소개하고저 한다. 짧은 기간의 방문이라 주로 해당연구소의 자체소개 자료를 중심으로 방문하면서 느낀점을 기술하고저 한다.초염기성암 기원의 사문암이 열수변질작용을 받아 생성되었음을 명확하게 지시하며, 따라서 활석 광석내에 존재하는 녹니석은 활석의 근원 광물로서 녹니석편암 및 녹니석 편마암 매의 녹니석이 활석화되고 남은 잔존광물이 아니라, 주변암에 의해 성분상의 영향을 받은 열수와 사문암과의 변질교대작용에 의한 활석화과정 중에 주로 생성된 것으로 추정된다. 이러한 결과는 연구지역의 활석광상이 초염기성암의 사문암화 작용과 활석화 작용의 두 가지 변질작용에 의해 형성되어졌음을 알려준다.농도 증가 없이 폐 조직에 약 50배 정도의 고농도 cisplatin을 투여할 수 있었으며, 또한 분리 폐 관류 시 cisplatin에 의한 직접적 폐 독성은 발견되지 않았다이 낮았으나 통계학적 의의는 없었다[10.0%(4/40) : 8.2%(20/244), p>0.05]. 결론: 비디오흉강경술에서 재발을 낮추기 위해 수술시 폐야 전체를 관찰하여 존재하는 폐기포를 놓치지 않는 것이 중요하며, 폐기포를 확인하지 못한 경우와 이차성 자연기흉에 대해서는 흉막유착술에 더 세심한 주의가 필요하다는 것을 확인하였다. 비디오흉강경수술은 통증이 적고, 입원기간이 짧고, 사회로의 복귀가 빠르며, 고위험군에 적용할 수 있고, 무엇보다도 미용상의 이점이 크다는 면에서 자연기흉에 대해 유용한 치료방법임에는 틀림이 없으나 개흉술에 비해 재발율이 높고 비용이 비싸다는 문제가 제기되고 있는 만큼 더 세심한 주의와 장기 추적관찰이 필요하리라 사료된다.

  • PDF

Microwave Dielectric Properties of (${Pb_{0.2}}{Ca_{0.8}}$)[$({Ca_{1/3}}{Nb_{2/3}})_{1-x}{Ti_x}$]$O_3$ Ceramics (Microwave Dielectric Properties of (${Pb_{0.2}}{Ca_{0.8}}$)[$({Ca_{1/3}}{Nb_{2/3}})_{1-x}{Ti_x}$$O_3$ 세라믹스의 마이크로파 유전특성)

  • Kim, Eung-Soo;Kim, Yong-Hyun;Kim, Jun-Chul;Bang, Kyu-Seok
    • Korean Journal of Materials Research
    • /
    • v.11 no.8
    • /
    • pp.708-712
    • /
    • 2001
  • Microwave dielectric properties of $(Pb_{0.2}Ca_{0.8})[(Ca_{1/3}Nb{2/3})_{1-x}Ti_x]O_3$ ceramics were investigated as a function of $Ti^{4+}$ content (0.05$\leq$x$\leq$0.35). A single perovskite phase was obtained from x=0.05 to x=0.15, and $TiO_2$ and $CaNb_2O^6$ were detected as a secondary phase beyond x=0.2. The structure was changed from orthorhombic at x=0.05 to cubic at x=0.35. Dielectric constant(K) was increased with increase of $Ti^{4+}$ content due to increase of rattling effect, and was inversely proportional to the cube of the average radius of B-site cation, however, Qf value was decreased, which was due to the decrease of grain size and the secondary phase. With the increase of $Ti^{4+}$ content, the temperature coefficient of resonant frequency(TCF) was controlled from -27.36 ppm/$^{\circ}C$ value to +18.4 ppm/$^{\circ}C$ value, which was caused by the influence of tolerance factor(t) and the bond valence of B-site. Typically, K of 51.67, Qf of 7268(GHz), TCF of 0 ppm/$^{\circ}C$ were obtained in the $(Pb_{0.2}Ca_{0.8})[(Ca_{1/3}Nb_{2/3})_{0.8}Ti_0.2]O_3$ sintered at 13$50^{\circ}C$ for 3h.

  • PDF

The Effect of 15% Carbamide Peroxide on the Surface Roughness and Staining of Esthetic Restoratives (15% Carbamide Peroxide가 심미수복재의 표면조도와 착색에 미치는 영향)

  • Kim, Soo-Hwa;Choi, Hye-Sook;Roh, Jj-Yeon;Kim, Kwang-Mahn
    • Journal of dental hygiene science
    • /
    • v.13 no.2
    • /
    • pp.165-173
    • /
    • 2013
  • The purpose of this study was to evaluate the surface change after 15% carbamide peroxide home bleaching to various restorative materials (composite resin [CR], resin modified glass ionomer [RMGI] and glass ionomer [GI]) and to observe the effect of surface condition of the materials on re-staining. Three esthetic restorative materials (Filtek Z250, 3M, USA; Fuji II LC, GC, Japan; Fuji II, GC, Japan) were used in this study. Twenty specimens per material group were made and divided into two groups (bleached and control). The specimens were immersed in coffee after applying bleaching agent. The color change and surface roughness were measured before and after bleaching and after immersion in coffee. The data were analyzed with SPSS 18.0. The results were as follows: 1. The color of all experiment groups was significantly changed after bleaching (p<0.05). RMGI was the greatest value of ${\Delta}E^*$ and ${\Delta}L^*$. GI and CR groups were in ordering (p<0.05). The ${\Delta}a^*$ value was decreased GI, RMGI and CR. RMGI was only significantly decreased in ${\Delta}b^*$ value (p<0.05). 2. The surface roughness before and after bleaching was significantly different on CR, RMGI and GI (p<0.05). 3. After staining with coffee, the value of ${\Delta}E^*$ was increased in GI, RMGI and CR, furthermore GI and RMGI showed significant difference in the bleaching groups (p<0.05). The ${\Delta}L^*$ value of GI and RMGI was significantly decreased. 4. The change of surface roughness after staining was not significantly different in all groups (p>0.05). The maintenance of color stability in esthetic restorations is one of the most important properties. Tooth whitening is for the aesthetic. Therefore, dental professionals should notice to patients about re-staining after tooth whitening. They should give an instruction that how to prevent and which kinds of agents could be stained.

Limitation of Nitrogen ion Implantation and Ionplating Techniques Applied for Improvement of Wear Resistance of Metallic Implant Materials (금속 임플란트 소재의 내마모성 향상을 위하여 적용되는 질소 이온주입 및 이온도금법의 한계)

  • 김철생
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.2
    • /
    • pp.157-163
    • /
    • 2004
  • Nitrogen ion implantation and ion plating techniques were applied for improvement of the wear resistance of metallic implant materials. In this work, the wear dissolution behaviour of a nitrogen ion implanted super stainless steel (S.S.S, 22Cr-20Ni-6Mo-0.25N) was compared with those of S.S.S, 316L SS and TiN coated 316L SS. The amounts of Cr and Ni ions worn-out from the specimens were Investigated using an electrothermal atomic absorption spectrometry. Furthermore, the Ti(Grade 2) disks were coated with TiN, ZrN and TiCN by use of low temperature arc vapor deposition and the wear resistance of the coating layers was compared with that of titanium. The chemical compositions of the nitrogen ion implanted and nitride coated layers were examined with a scanting auger electron spectroscopy. It wat observed that the metal ions released from the nitrogen ion implanted S.S.S surface were significantly reduced. From the results obtained, it was shown that the nitrogen ion implanted zone obtained with 100 KeV ion energy was easily removed within 200,000 revolutions from a wear dissolution testing under a similar load condition when applied to artificial hip joint. The remarkable improvement in wear resistance weir confirmed by the nitrides coated Ti materials and the wear properties differ greatly according to the chemical composition of the coating layers. for specimens with the same coating thickness of about 3$\mu\textrm{m}$, TiCN coated Ti showed the highest wear resistance. However, after removing the coating layers, the wear rates of all nitrides coated Ti reverted to their normal rates of below 10,000 revolutions from Ti-disk-on-disk wear testing under the same load condition. From the results obtained, it is suggested that the insufficient depth of the 100 Kel N$\^$+/ ion implanted zone and of the nitrides coated layers of 3$\mu\textrm{m}$ are subject to restriction when used as frictional parts of load bearing implants.

Hair Heavy Metal Contents in Mentally Retarded Children I - In Association with Lead - (정신지체아 두발 중 중금속 함량 I - 납과의 관련성 -)

  • Kim, Doo-Hie;Kim, Ock-Bae;Chang, Bong-Ki
    • Journal of Preventive Medicine and Public Health
    • /
    • v.22 no.1 s.25
    • /
    • pp.125-135
    • /
    • 1989
  • This paper was carried out to study on correlation between mentally retardation and lead and zinc. The subjects were 297 mentally retarded children: 132 of Bomyung special school and Sunmyung, which were located in Taegu city of Korea. The former had their parents but the latter had not. The control group 63 children were randomly seleted from the Dong-in primary school near to Medical School of Kyungpook National University. Atomic absorption spectrophotometer, model IL-551 connected with CTF atomizer(IL. 655) was used for the analysis of lead and zinc. The mean value of lead in hair of mentally retarded children was $14.97{\pm}3.71ppm$ which is significantly higher than that of control group, $11.36{\pm}2.83ppm$. But the content of zinc was not significant in both groups. In the lead there was no significant correlation to age but significant negative correlation to IQ. Zinc showed significant correlation to age but not to IQ. Among the handicapped children, no signigicant correlation between orphan group and non orphan group. Handicaps of mentally-retarded children were speech impairment, emotional disturbance, double and triple handicaps, sensory impairment and abnormal dietary patterns. There were significantly higher contents of lead compared with normal group, except the latter two groups. The disease conditions of mentally retarded children were mongolism, autism, cerebral palsy, epilepsy and microcephaly. In comparing with mongolism, significant difference were existent only on the cerebral palsy and group of unknown etiology. We attempted to divide their past history into external etiology and internal etiology, but could not find significant difference. In view of the whole results, the relationship between mentally-retarded children and lead was presumed to be the early time exposure rather than long interval exposure during growth and the contact opportunity was considered important subject in maternal and child health care.

  • PDF

Synthesis of Cyclen-Based Copper Complexes as a Potential Estrogen Receptor Ligand (에스트로젠 수용체 리간드로서 사이클렌을 기본 구조로 한 구리 착물의 합성)

  • Park, Jeong-Chan;Pandya, Darpan N.;Jeon, Hak-Rim;Lee, Sang-Woo;Ahn, Byeong-Cheol;Lee, Jae-Tae;Yoo, Jeong-Soo
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.4
    • /
    • pp.326-334
    • /
    • 2007
  • Purpose: The estrogen receptor (ER), which is over-expressed in ER-positive breast tumors, has been imaged by positron emission tomography (PET) using $[^{18}F]$ labeled estrogen ligands, especially $[^{18}F]FES$. However, $[^{18}F]$ has relatively short-lived half-life ($t_{1/2}$ =1.8 h) and the labeling yield of radio-fluorination is usually low compared with $^{64}Cu\;(t_{1/2}=12.7\;h)$. 1,4,7,10-tetraazacyclododecane (cyclen) is used to form stable metal complexes with copper, indium, gallium, and gadolinium. With these in mind, we prepared cyclen-based Cu complexes which mimic estradiol in aspect of two hydroxyl groups. Materials and Methods: 1.7-Protected cyclen, 1.7-bis (benzyloxycarbonyl)-cyclen was synthesized according to the reported procedure. After introducing two 4-benzyloxybenzyl groups at 4,10-positions, the benzyloxycarbonyl and benzyl groups were removed at the same time by hydrogenation on Pd/C to give 1,7-bis(4-hydroxybenzyl)-1,4,7,10-tetraazacyclododecane (1). Results: The prepared ligand 1 was fully characterized by $^1H,\;^{13}C$ NMR, and mass spectrometer. The synthesized ligand was reacted with copper chloride and copper perchlorate to give copper complexes $[Cu(1)]^{2+}2(CIO_4^-)\;and\;[Cu(1)Cl]^+Cl^-$ which were confirmed by high-resolution mass (FAB). Conclusion: We successfully synthesized a cyclen derivative of which two phenol groups are located on trans position of N-atoms. And, two Cu(ll) complexes of +2 and +1 overall charge, were prepared as a potential PET tracers for ER imaging.