• Title/Summary/Keyword: 원소분석

Search Result 2,512, Processing Time 0.032 seconds

Study on elemental analysis of metal and ceramic samples by using laser ablation ion trap mass spectrometry(LAITMS) (레이저 이온화 이온트랩 질량분석법을 이용한 금속 및 세라믹 시료의 원소분석에 관한 연구)

  • Song, Kyuseok;Park, Hyunkook;Cha, Hyungki;Lee, Sang Chun
    • Analytical Science and Technology
    • /
    • v.15 no.1
    • /
    • pp.7-14
    • /
    • 2002
  • Laser ablation ion trap mass spectrometry (LAITMS) was developed for the analysis of metal and ceramic samples. For this study, XeCl excimer laser (308 nm) was used for ablating the samples and ITMS was used as a detector. Samples were introduced from outside of a ring electrode and this way of sample introduction was very effective for solid samples when laser ablation was employed. Helium gas was used as a buffer gas, and its effect on sensitivity and some parameters (buffer gas pressure, ion storage time, and cut-off RF voltage) were studied. The optimized conditions were $1{\times}10^{-4}$ Torr of buffer gas pressure, 100 ms of ion storage time and $1150V_{p-p}$ of cut-off RF voltage. From that results, copper (Cu) and molybdenum (Mo) metals were tested with LAITMS and the mass spectra of these pure metals were compared with the natural abundance of isotope ratio. We also examined ceramic samples ($Al_2O_3$, $ZrO_2$) and represented the result of elemental analysis.

Intercomparison and Determination of Trace Elements in Urban Dust by Neutron Activation Analysis (중성자방사화분석법을 이용한 대기분진중의 미량원소 비교분석)

  • Chung, Yong-Sam;Moon, Jong-Hwa;Kim, Sun-Ha;Park, Kwang-Won;Kang, Sang-Hun
    • Analytical Science and Technology
    • /
    • v.13 no.2
    • /
    • pp.179-188
    • /
    • 2000
  • Trace elements in air samples artificially loaded on filters with urban dust and the bulk material of urban dust as an environmental sample were determined non-destructively using instrumental neutron activation analysis. Standard reference material (Urban Dust, SRM 1648) of the National Institute of Standard and Technology was used for the analytical quality control. The relative error for 37 elements was less than 15% and the standard deviation was less than 10%. 29 elements in the urban dust and 21 elements in the loaded filter sample were determined respectively. To evaluate the proficiency and reliability of the measurement, data intercomparison was performed and 39 analytical laboratories participated in the analysis using different analytical methods; neutron activation analysis, particle induced X-ray emission analysis, X-ray fluorescence analysis and atomic absorption spectrometry. Z-scores were calculated using the standard deviation of the laboratorie's mean as target standard deviation, and a good result was obtained that the values fall between -1 and +1 except some elements.

  • PDF

Precambrian Kyeonggin gneiss complex (선캠브리아 경기육괴 중 대리암의 연대측정에 대한 예비연구)

  • 박계헌;정창식
    • The Journal of the Petrological Society of Korea
    • /
    • v.2 no.2
    • /
    • pp.130-138
    • /
    • 1993
  • Kyeonggi Gneiss complex forming Korean Precambrian basement is mainly composed of high-grade metasedimentary rocks, which are generally difficult to determine their absolute ages. We examined the feasibility of successive absolute age determination method for the marbles from this basement. We used hydrochloric acid for the selective dissolution of carbonate minerals from the marbles. Trace element analysis shows that most of Zr and Rb are concentrated in the residues. U in the residue is more abundant than that in HC1-dissolved parts. Pb, Sr, Sm, and Nd are somewhat evenly distributed between HC1-dissolved parts and the residues. }Th shows rather complex behavior. Sr isotopic compositions of the HC1-dissolved parts reveal mixing with Sr from non-carbonate minerals having much higher $^{87}Sr/^{86}Sr$ ratios. We suggest that the most reliable method in the age determination for the marbles of this area is measuring Pb isotopic ratios of the pieces of pure marbles.

  • PDF

Natural isotopes and trace element analyses in glass samples (판유리 시료에서 동위원소 및 미량원소 분석법)

  • Min, Ji-Sook;Heo, Sangcheol;Kim, Jae-Guin;Kim, Eun-Ho;Kim, Dong-Wook;Chung, Hee-Sun
    • Analytical Science and Technology
    • /
    • v.20 no.3
    • /
    • pp.219-226
    • /
    • 2007
  • Glass is frequently encountered as types of materials that are submitted to forensic science laboratories as a result of trace evidence transfers. The repeatability and the reproducibility of trace element analysis were presented. An analysis of variance (ANOVA) was performed on laser ablation inductively coupled plasma spectrometric analyses of the fragments to identify the source. Pairwise comparisons were completed for all samples. In a pairwise comparison, each sample was compared to each other for a possible [n(n-1)/2] (n : numbers of the samples) total comparison to associate/discriminate samples using Tukey's HSD method. The aim of this study was to determine the utility of LA-ICP-MS for multi-element analysis of forensic samples. The 12 glass fragments from two manufacturers were collected and analyzed to identify the source. An analysis of variance (ANOVA) was performed on 31 elements in NIST 612 Trace elements in Glass. Elements were classified into four categories defined by the combination of precision and variation of inter-samples. We selected 11 elements, 209Bi, 90Zr, 121Sb, 178Hf, 59Co, 238U, 208Pb, 140Ce, 118Sn, 49Ti and 137Ba. 6 pairs out of 66 possible pairs were not distinguished when compared by 137Ba (p<0.05). However, all samples were distinguished using both 49Ti and 137Ba (p<0.05). In conclusion, multi-elemental analysis with LA-ICP-MS is a potential tecnique for the discrimination of forensic samples.

Array Localization for Multithreaded Code Generation (다중스레드 코드 생성을 위한 배열 지역화)

  • Yang, Chang-Mo;Yu, Won-Hui
    • The Transactions of the Korea Information Processing Society
    • /
    • v.3 no.6
    • /
    • pp.1407-1417
    • /
    • 1996
  • In recent researches on thread partitioning algorithms break a thread at the long latency operation and merge threads to get the longer threads under the given constraints. Due to this limitation, even a program with little parallelism is partitioned into small-sized threads and context-swithings occur frequently. In the paper, we propose another method array localization about the array name, dependence distance(the difference of accessed element index from loop index), and the element usage that indicates whether element is used or defined. Using this information we can allocate array elements to the node where the corresponding loop activation is executed. By array localization, remote accesses to array elements can be replaced with local accesses to localized array elements. As a resuit,the boundaries of some threads are removed, programs can be partitioned into the larger threads and the number of context switchings reduced.

  • PDF

가속기질량분석기술(加速器質量分析技術)(AMS)의 원리(原理) 및 응용(應用)

  • Park, Geung-Sik;U, Jeong-Ju
    • Analytical Science and Technology
    • /
    • v.7 no.3
    • /
    • pp.1069-1084
    • /
    • 1994
  • 수 MV급 탄뎀형 가속기와 정전형, 자장형 질량분석기를 결합함으로써 존재비가 극히 작은 동위원소 측정이 가능해진다. 수 MeV로 가속이 되면 분해에 방해가 되는 모든 분자이온들이 제거되며, 탄뎀형 가속기에서는 음이온으로부터 가속이 개시되므로 몇몇 음이온을 형성하지 못하는 동중원소의 간섭으로부터 자유로워지기 때문에 고감도분석이 실현될 수 있다. 이외에 음이온을 형성하는 동중원소들은 주로 이온함인 최종 검출기에서의 유효 전하에 따른 에너지손실 차이를 이용하여 효과적으로 제거할 수 있다. 현재는 주로 장반감기 방사성동위원소인 $^{10}Be$, $^{14}C$, $^{26}Al$, $^{36}Cl$$^{129}I$ 등의 측정법이 확립되어 천연시료 중에서 동위원소 존재비 $10^{-12}$에서 $10^{-15}$까지의 정량이 가능하며, 원자수로 환산한 검출하한을 $10^5$개가 된다. 또한 해당 원소를 기준으로 소요 시료량은 대부분 mg 정도로 충분하다. 지금까지는 불가능했던 이러한 특징으로 인해 지난 수년간 AMS(Accelerator Mass Spectrometry)가 활용되어 온 연구분야는 지구과학(기후학, 우주화학, 빙하학, 수문학, 해양학, 퇴적학, 화산학 및 광물탐사), 인류 및 고고학(연대측정), 그리고 물리학(천체물리, 핵 및 입자물리) 등으로 다양하다. 이외에 생의학 및 재료과학 분야에서도 AMS를 활용하고자 하는 노력이 계속되고 있다. 본 해설에서는 가속기질량분석기술의 특징, 원리, 장치 및 활용분야 등을 소개하고자 하며, 이로써 관련 분야의 연구 활성화에 기여하고자 한다.

  • PDF

Development of Radiochemical Analysis of Uranium Isotopes in Soil Samples with Extraction Chromatography (크로마토 그래피 추출법을 사용한 토양시료중 우라늄 동위원소 화학분석법 개발)

  • Lee, Myung-Ho;Choi, Guk-Sik;Cho, Young-Hyun;Lee, Chang-Woo;Lee, Soo-Yong
    • Journal of Radiation Protection and Research
    • /
    • v.26 no.1
    • /
    • pp.1-6
    • /
    • 2001
  • An accurate and rapid analytical technique of uranium isotopes in highly contaminated soil samples was developed and validated by application to the IAEA-Reference samples. For overcoming the demerits of the TBP extraction method, sample materials were decomposited with $HNO_3$ and HF, and uranium isotopes were purified by an anion exchange resin and a TRU Spec resin. With the extraction chromatography method, the hindrance elements were completely removed from the uranium fraction. The chemical yields with the extraction chromatography method were more 10% higher than those with the TBP extraction method. The concentrations of uranium isotopes in soil samples using the extraction chromatography method were consistent with the reference values reported by the IAEA.

  • PDF