• Title/Summary/Keyword: 원격검침

Search Result 222, Processing Time 0.035 seconds

An Efficient Dynamic Workload Balancing Strategy Design of the Wireless Reading/Management System for the Corrosion Monitoring of Underground Structures (지하 구조물 부식 감시를 위한 무선 검침/관리 시스템 설계)

  • Kwan, Yong-Kwang
    • Journal of the Korea Society of Computer and Information
    • /
    • v.19 no.7
    • /
    • pp.95-102
    • /
    • 2014
  • There are a variety of structures below the surface are buried. In particular, if It is experiencing problems in the city gas pipe or electrical wire, our safety would be greatly jeopardized. Therefore, the underground structures which encounter a variety of pollutants are highly sensitive to corrosion. So if you are not identify the degree of corrosion, it can lead to large accidents such as gas leakage. Until now, person visit directly every underground structure to measure and record manually, but This approach requires a lot of human and material resources and the continuity of management. Therefore, the research to find out the risk factors quickly via the continuous management is needed, and in this paper the structures management systems in the vehicle being moved by combining ICT underground structures for state information wirelessly collects and analyzes system is proposed.

A Development Of Low Power PLC Modem for Monitoring of Power Consumption and Breaking of Abnormal Power (전력감시 및 이상전력 차단 기능을 갖는 저전력 전력선통신 모뎀 개발)

  • Yoon, Jae-Shik;Wee, Jung-Chul;Song, Yong-Jae;Park, Chung-Ha;Kim, Jae-Heon
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1964_1965
    • /
    • 2009
  • 최근 경제성장과 함께 생활수준의 향상으로 인하여 홈 게이트웨이는 디지털 홈 가전기기에 초고속 통신망 접속 기능을 제공하며 각종 기기들을 하나로 네트워크화 하는 중요한 기능을 담당하게 된다. 전력선 통신은 전력선을 매체로 하기 때문에 신규선로의 포설 없이 가전기기 및 정보화 서비스 모뎀들의 네트워크화에 용이할 뿐만 아니라 커버리지 확장에도 뛰어나서 디지털 가전, 원격검침, 전력설비 감시제어, 국가 재난 감시 시스템 등의 기본 통신 방식으로 가장 유력한 기술로써 디지털 가전을 포함한 유비쿼터스 전기설비 네트워크 구성에서 필수적 기술로 채택되고 있기 때문에 지능형 홈 네트워크, 전력IT 부가 서비스, 설비감시 네트워크, 유비쿼터스 네트워크 관련 기술에 대한 파급 효과가 매우 크며, 디지털 가전의 기본 통신 방식으로 가장 유력한 기술로써 디지털 가전 구성에서 필수적 기술로 채택되고 있다. 본 연구에서는 전력선통신모뎀을 이용하여 가전기기의 전력 소비를 감지할 수 있는 센서를 내장한 전력선 통신기반의 전력 감시 모듈을 개발하여 실시간 원격 모니터링을 통해 소비전력 패턴을 작성한다. 그리고 전력감시 모듈에 연결된 가전기기의 소비전력 패턴 분석을 통해 전력소비 이상 유무를 감지할 수 있는 알고리즘을 개발, 탑재하여 이상 유무를 판단하고 전력소비가 급증할 시 자동으로 전력을 차단하여 화재나 누전의 위험을 방지한다. 이에 본 연구는 전력감시 및 이상전력 차단기능을 갖는 저전력 전력선통신 모뎀 개발에 관한 것이다.

  • PDF

The Study On Monitoring of Power Consumption and Breaking of Abnormal Power using Power Line Commnuncation Modem (전력선통신 모뎀을 이용한 전력소비감시 및 이상전력 차단해 관한 연구)

  • Yoon, Jae-Shik;Wee, Jung-Chul;Lim, Ja-Yong;Kim, Jae-Heon
    • Proceedings of the IEEK Conference
    • /
    • 2009.05a
    • /
    • pp.279-280
    • /
    • 2009
  • 최근 경세성장과 함께 생활수준의 향상으로 인하여 에너지 수요는 매년 증가하고 있으며 그 중에서 하나인 전력수요도 역시 급격히 늘어나고 있는 추세이다. 이와 더불어 투자자원 및 입지확보의 어려움, 환경제약의 문제로 전력 공급의 어려움은 날로 증가되고 있다. 따라서 수요증가를 전력공급 능력의 증진뿐만 아니라 수요관리 측면에서도 필요성이 대두되고 있다. 전력선 통신은 전력선을 매체로 하기 때문에 신규선로의 포설 없이 가전기기 및 정보화 서비스 모뎀들의 네트워크화에 용이할 뿐만 아니라 커버리지 확장에도 뛰어나서 디지털 가전, 원격검침, 전력설비 감시제어, 국가 재난 감시 시스템 등의 기본 통신 방식으로 가장 유력한 기술로써 디지털 가전을 포함한 유비쿼터스 전기설비 네트워크 구성에서 필수적 기술로 채택되고 있기 때문에 지능형 홈 네트워크, 전력IT 부가서비스, 설비감시 네트워크, 유비쿼터스 네트워크 관련 기술에 대한 파급 효과가 매우 크며, 디지털 가전의 기본 통신 방식으로 가장 유력한 기술로써 디지털 가전 구성에서 필수적 기술로 채택되고 있기 때문에 지능형 홈 네트워크 관련 기술에 대한 파급 효과가 매우 크다. 본 연구에서는 전력선통신모뎀을 이용하여 가전기기의 전력 소비를 감지할 수 있는 센서를 내장한 전력선 통신기반의 전력 감시 모듈을 개발하여 실시간 원격 모니터링을 통해 소비전력 패턴을 작성한다. 그리고 전력감시 모듈에 연결된 가전기기의 소비전력 패턴 분석을 통해 전력소비 이상 유무를 감지할 수 있는 알고리즘을 개발, 탑재하여 이상유무를 판단하고 전력소비가 급증할 시 자동으로 전력을 차단하여 화재나 누전의 위험을 방지한다. 이에 본 연구는 전력선통신을 이용하여 전력소비감시 및 이상전력차단에 관한 연구에 관한 것이다.

  • PDF

Home Network Speech Interface Using VoiceXML (VoiceXML을 이용한 홈 네트워크 음성 인터페이스)

  • Roh, Yong-Wan;Kim, Dong-Gyu;Shin, Jeong-Hoon;Chung, Kwang-Woo;Hong, Kwang-Seok
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.6 no.3
    • /
    • pp.127-133
    • /
    • 2005
  • In this paper, we propose speech interlace using VoiceXML in home network system Existing home network uses Bluetooth, IrDA, wireless LAN and Home RF but these was able to use a long distance such as outdoors or these was difficult to using method. The proposing VoiceXML speech interlace is supported with home network services more than other interface technology in a long distance also speech interlace controls home server using a wire and a wireless phone and is informed of problems to direct calling for user through VoiceXML server. In this paper, such speech interlace is able to use the aspect of home network and supports to practical remote gauge examination, remote control services. And on the basic of that, we evaluate efficiency of purposed method.

  • PDF

Field Application of Waterworks Automatic Meter Reading and Analysis of Household Water Use (상수도 원격검침시스템의 현장 적용성 평가 및 가정용수 사용량 분석)

  • Joo, Jin Chul;Ahn, Hosang;Ahn, Chang Hyuck;Ko, Kyung-Rok;Oh, Hyun Je
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.10
    • /
    • pp.656-663
    • /
    • 2012
  • After the construction of waterworks automatic meter reading with 15 mm diameter digital water mater with magnetoresistance sensor developed in this study at 96 households of apartment complexes located in Incheon-City B-Gu S-Dong, the feasibility of field application of waterworks automatic meter reading was evaluated. The field application of waterworks automatic meter reading was performed from July to December in 2011, and average reception rate was as low as 84.6% due to the instable wibro networks, the existence of communication blackout and temporary malfunction of router. After the extraction of 10 households with one to five residents out of 96 households by using stratified random sampling method and analysis of domestic water use, it was found that domestic water use was significant at August and showed a decreasing trend at September, followed by increase in domestic water use at November and decrease in domestic water use at December. This phenomenon should be attributed to weather factors (temperature, humidity, etc.), which significantly affected domestic water use. Similar trend in domestic water use in terms of weather factors was obtained in case of Liter per capita day of water use after the extraction of 30 households out of 96 households by using stratified random sampling method. After analysis of Liter per capita day for 96 households, single residents increases resulted in reduction of domestic water usage by about 14% of Liter per capita day. These results might be due to the fact that domestic water usage such as laundry, beverages, catering, cleaning, etc. should be required for even the household with one resident, whereas domestic water usage for those common utilization can be significantly saved for the household with more than one resident.

An Efficient Numeric Character Segmentation of Metering Devices for Remote Automatic Meter Reading (원격 자동 검침을 위한 효과적인 계량기 숫자 분할)

  • Toan, Vo Van;Chung, Sun-Tae;Cho, Seong-Won
    • Journal of Korea Multimedia Society
    • /
    • v.15 no.6
    • /
    • pp.737-747
    • /
    • 2012
  • Recently, in order to support automatic meter reading for conventional metering devices, an image processing-based approach of recognizing the number meter data in the captured meter images has attracted many researchers' interests. Numerical character segmentation is a very critical process for successful recognition. In this paper, we propose an efficient numeric character segmentation method which can segment numeric characters well for any metering device types under diverse illumination environments. The proposed method consists of two consecutive stages; detection of number area containing all numbers as a tight ROI(Region of Interest) and segmentation of numerical characters in the ROI. Detection of tight ROI is achieved in two steps: extraction of rough ROI by utilizing horizontal line segments after illumination enhancement preprocessing, and making the rough ROI more tight through clipping utilizing vertical and horizontal projection about binarized ROI. Numerical character segmentation in the detected ROI is stably achieved in two processes of 'vertical segmentation of each number region' and 'number segmentation in the each vertical segmented number region'. Through the experiments about a homegrown meter image database containing various meter type images of low contrast, low intensity, shadow, and saturation, it is shown that the proposed numeric character segmentation method performs effectively well for any metering device types under diverse illumination environments.

Reduction of Chattering Error of Reed Switch Sensor for Remote Measurement of Water Flow Meter (리드 스위치 센서를 이용한 원격 검침용 상수도 계량기에서 채터링 오차 감소 방안 연구)

  • Ayurzana, Odgerel;Kim, Hie-Sik
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.44 no.4 s.316
    • /
    • pp.42-47
    • /
    • 2007
  • To reduce the chattering errors of reed switch sensors in the automatic remote measurement of water meter a reed switch sensor was analyzed and improved. The operation of reed switch sensors can be described as a mechanical contact switch by approximation of permanent magnet piece to generate an electrical pulse. The reed switch sensors are used mostly in measurement application to detect the rotational or translational displacement. To apply for water flow measurement devices, the reed switch sensors should keep high reliability. They are applied for the electronic digital type of water flow meters. The reed switch sensor is just mounted simply on the conventional mechanical type flow meter. A small magnet is attached on a pointer of the water meter counter rotor. Inside the reed sensor two steel leaf springs make mechanical contact and apart repeatedly as rotation of flow meter counter. The counting electrical contact pulses can be converted as the water flow amount. The MCU sends the digital flow rate data to the server using the wireless communication network. But the digital data is occurred difference or won by chattering noise. The reed switch sensor contains chattering error by it self at the force equivalent position. The vibrations such as passing vehicle near to the switch sensor installed location causes chattering. In order to reduce chattering error, most system uses just software methods, for example using filter algorithm and also statistical calibration methods. The chattering errors were reduced by changing leaf spring structure using mechanical characteristics.

Design and Application of a LonRF Device based Sensor Network for an Ubiquitous Home Network (유비쿼터스 홈네트워크를 위한 LonRF 디바이스 기반의 센서 네트워크 설계 및 응용)

  • Ro Kwang-Hyun;Lee Byung-Bog;Park Ae-Soon
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.7 no.3
    • /
    • pp.87-94
    • /
    • 2006
  • For realizing an ubiquitous home network(uHome-net), various sensors should be able to be connected to an integrated wire/wireless sensor network. This paper describes an application case of applying LonWorks technology being widely used in control network to wire/wireless sensor network in uHome-net and the design and application of LonRF device that consists of a neuron chip including LonTalk protocol, a 433.92MHz RF transceiver, a sensor, and application programs. As an application example of the LonRF device, the LonRF smart badge that can measure the 3D location of objects in indoor environment and interwork with the uHome-net was developed. LonRF device based home network services were realized on the uHome-net testbed such as indoor positioning service, remote surveillance service and remote metering service were realized. This research shows that LonWorks technology based sensor network could be applicable to the control network in an ubiquitous home network and the LonRF device can be used as a wireless node in various sensor networks.

  • PDF

Implementation of Intelligent Home Network System using Wireless Sensor (무선센서를 이용한 지능형 홈네트워크 시스템 구현)

  • Ju, Jae-han;Na, Seung-kwon
    • Journal of Advanced Navigation Technology
    • /
    • v.21 no.3
    • /
    • pp.294-299
    • /
    • 2017
  • Home network service is evolving into a service that can receive contents such as remote education, home automation, remote meter reading and various entertainment anytime and anywhere by connecting all household appliances in home with wired and wireless network. In this paper, an intelligent home gateway installed at home is connected to the mobile communication terminal from the outside to solve the problems of the existing home network and configure and maintain a more efficient and comfortable home network environment for the user, In the window, the login page is activated to confirm the user access authority, and the user proceeds the authentication procedure through own login information. When the normal authentication procedure is performed, the intelligent home gateway maintains only the network connection with the user, and the user presents the intelligent home network system using the RFID which is accessed by the intelligent home network system.

DEVELOPMENT OF THE THERMAL MODEL FOR KITSAT-1/2 MICROSATELLITES AND ITS VERIFICATION USING IN-ORBIT TELEMETRIES (우리별 1, 2호의 열제어 모델 개발 및 궤도 운용 결과를 바탕으로 한 모델의 검증)

  • 박성동;배정석;성단근;최순달
    • Journal of Astronomy and Space Sciences
    • /
    • v.13 no.2
    • /
    • pp.105-116
    • /
    • 1996
  • This study is based upon the thermal modeling, analysis and operational results of KITSAT-1 and KITSAT-2 microsatellites launched on August 11, 1992 and Septermber 26, 1993, respectively. As KITSAT-1/2 was designed to be launched as an auxiliary payload of ARIANE launcher, the constraints on volume, power consumption, and mass were required to adopt passive thermal control method controlling absorptivity, emissivity, and conductivities among adjacent modules. The main of KITSAT was to take Earth images using CCD cameras positioned at the bottom of spacecraft, in which the cameras were always pointing to the center of Earth. This study is concerned with orbital analysis, thermal modeling, simulation results, and its verification by utilizing in-orbit telemetry data of KITSAT-2. The results of telemetry analysis show that the thermal modeling is matched to actual temperature data within 10 degrees of error range in average.

  • PDF