• Title/Summary/Keyword: 원거리진동

Search Result 39, Processing Time 0.028 seconds

Optimization of the Number and Position of Far Field Sources in Using the Equivalent Source Method (등가음원법에서의 원거리음원의 위치와 개수의 최적화 연구)

  • 백광현
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.13 no.10
    • /
    • pp.743-750
    • /
    • 2003
  • The equivalent source method(ESM) is used for the calculation of the internal pressure field for an enclosure which can have arbitrary boundary conditions and nay include internal objects which scatter the sound field. The advantage of using ESM is that it requires relatively low computing cost and is easy to model the internal diffracting objects. Typical ESM modeling uses two groups of equivalent source positions. One group includes the first order images of the source inside the enclosure. The Positions of the other group are usually on a spherical surface some distance outside the enclosure. The normal velocity on the surfaces of the enclosure walls is evaluated at a larger number of positions than there are equivalent sources. The sum of the squared difference between this velocity and the expected is minimized by adjusting the strength of the equivalent sources. This study is on the optimal far field sources positions when using the equivalent source method. In general, the far field sources are evenly distributed on a surface of a virtual sphere which is centered at the enclosure with a sufficiently large radius. In this study. optimal far field source locations are searched using simulated annealing method for various radii of spheres where far field sources are located. Simulation results showed that optimally located sources with adequate distance away from the enclosure center gave better result than sources with even distribution even with a smaller number of far field sources.

User Emotional Interactive Mirror (사용자 감성 인터랙티브 미러)

  • Gang, Geon-Ung;Gu, Jin-A;Kim, Na-Yeon;Lee, Dong-Hyeon;Jo, A-Yeong;Jo, Hye-Min;Hwang, Min-Cheol
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 2009.05a
    • /
    • pp.183-186
    • /
    • 2009
  • 본 연구는 인터랙티브 미러 (Interactive Mirror)를 제작하여 서로 다른 공간에 있는 사용자들에게 시각 청각 촉각적 요소를 조합한 감성 커뮤니케이션(communication)을 제공하고자 한다. 인터랙티브 미러는 원거리상의 사용자들이 거울에 비친 상대방의 모습을 실시간으로 보면서 대화가 가능한 일종의 화상 대화 장치이다. 화면의 기능을 수행하는 거울을 매개로 하여 실시간 화상 대화가 가능하고, 사용자들은 실제 도구인 붓, 지우개, 도장을 이용하여 그림을 그릴 수 있다. 또한, 사용자가 인형을 터치하면 상대방에게 진동이 전해지는 구조를 통해 원거리상의 사용자간에 감성적인 커뮤니케이션이 가능하도록 한다.

  • PDF

A Study on Structural Intensity Measurement of Semi-infinite Beam (반무한보의 진동 인텐시티 계측에 대한 연구)

  • 이덕영;박성태
    • Journal of KSNVE
    • /
    • v.7 no.1
    • /
    • pp.43-53
    • /
    • 1997
  • This paper investigated the practical use for measuring the structural intensity (power flow per width of cross section) in a uniform semi-infinite beam in flexural vibration. The structural intensity is obtained as a vector at a measurement point, One-dimensional structural intensity can be obtained from 4-point cross spectral measurement, or 2-point measurement on the assumption of far field. The measurement errors due to finite difference approximation and phase mismatch of accelerometers are examined. For precise measurements, it would be better to make the value of k$\delta$(wave number x space between accelerometers) between 0.5 and 1.0. Formulation of the relation between bending waves in structures and structural intensity makes it possible to separate the wave components by which one can get a state of the vibration field. Experimental results are obtained from 2- and 4-point measurement performed at 200mm (near field) and 400mm (far field) apart from excitation point in random excitation. the results are compared with the theoretical values and measured values of input power spectrum in order to verify the accuracy of structural intensity method, 2-point method is suggested as the practical structural intensity method.

  • PDF

Analysis of Ground Vibration Characteristics by Test Blasting in Southern Region of Jeju (제주 남부지역의 시험발파에 의한 지반진동 특성 분석)

  • Kim, Seung Hyun;Lee, Dong Wook
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.39 no.3
    • /
    • pp.419-429
    • /
    • 2019
  • The characteristics of ground vibration have been analyzed by test blasting in southern region of Jeju (layered ground consisting of basalt and clinker). By grasping the principal component of ground vibration and depriving the prediction equations of ground vibration, the propagation characteristics of ground vibration have been compared to the domestic design guidelines. Ground vibration in layered ground has a small amplitude at a short distance. However, it has been confirmed that the vibration energy is transmitted further by virtue of the low attenuation of the ground vibration as it goes to a longer distance. Moreover, the frequency has been confirmed to be low frequency band. The outcome has been defined that it resulted because the clinker layer with a large pore transforms the blasting energy seismic wave with high frequency into a low frequency wave having a long waveform period. In addition, the limits of design guidelines were identified by comparing the ground vibration of Jeju and other bedrock areas. Thus, the necessity of the development of the prediction equations of ground vibration utilized in design that reflect the characteristics of the area has been suggested.

A Numerical Analysis Study on the Estimation of the 3D Underwater Radiated Noise Pattern using the Hull Vibration Signals (선체진동신호를 이용한 3차원 수중방사소음 패턴 산출에 대한 수치해석 연구)

  • Yi, Jong-Ju;Kang, Myung-Hwan;Han, Seung-Jin;Bae, Soo-Ryong;Kim, Jae-Ho;Jung, Woo-Jin
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.24 no.10
    • /
    • pp.770-779
    • /
    • 2014
  • In this study, a numerical estimation method for 3D underwater radiated noise pattern using hull vibration and total acoustic power of the vibrating structure in the far-field is proposed. The underwater radiated noise pattern is known to be predicted using the vibration signals and radiation efficiency of each surface patch. But it is very difficult to know radiation efficiency of each surface patch which is one of important factors to calculate the 3D underwater radiated noise pattern. Instead of using radiation efficiency of each patch, the underwater radiated noise level is modified with the total acoustic power of the vibrating structure. The suggested estimation method for underwater radiated noise pattern is discussed with numerical model.

Study of Lawson Formula at near- and far-field (근거리 및 원거리에서의 Lowson Formula에 대한 연구)

  • Wonju Jeon;Lee, Duck-Joo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.11b
    • /
    • pp.1393-1393
    • /
    • 2001
  • This paper reviews the Lawson formula which predicts the sound field of a point force in arbitrary motion. The acoustic density was represented by an integral of integrand including the generalized function and its partial derivative at retarded time. After skillful integration, a mathematically exact formula was yielded with some terms which were still remained in need of numerical calculations. The significance of further mathematical progress is discussed in this paper. And also, the adequacy of procedures deriving the far- and near-field terms is investigated from the viewpoint of radiation.

  • PDF

Development of Leak and Vibration Monitoring System for High Pressure Steam Pipe by Using a Camera (카메라를 이용한 고압 증기 배관 누설/진동 감시시스템 개발)

  • Jeon, Hyeong-Seop;Suh, Jang-Su;Chae, Gyung-Sun;Son, Ki-Sung;Kim, Se-Oh;Lee, Nam-Hee
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.36 no.6
    • /
    • pp.496-503
    • /
    • 2016
  • Leakages at plant structures of power and petrochemistry plants have led to casualties and economic losses. These leakages are caused by fatigue failure of pipelines and their wall thickness. Vibration measurement methods for plant pipelines mainly use acceleration and laser sensors. These sensors are difficult to install and operate and thus lead to an increase in operational cost especially for wide area surveillance. Recently, measurements of leak and vibration displacements using cameras have attracted the interest of many researchers. This method has advantages such as simple installation, long distance monitoring, and wide area surveillance. Therefore, in this paper, we have developed a system that can measure the leakage and vibrational displacement by using a camera. Furthermore, the developed system was verified with experimental data.

Measurement of Tire Structural Vibration Noise Using Spatial Transformation of Sound Field Technique (음장의 공간적 변환기법을 이용한 타이어 구조 진동 소음 측정)

  • Kim, Byoung-Sam
    • The Journal of the Acoustical Society of Korea
    • /
    • v.14 no.5
    • /
    • pp.11-19
    • /
    • 1995
  • The Interaction between tire and road is responsible for the excited vibration of the tire, and It is also important for the sound radiation. In this paper. measurement of tire structural vibration noise from a chassis dynamometer using Spatial Transformation of Sound Field(STSF) technique is studied. STSF involving a scan that uses an array of transducers over a planar surface close to the source is under investigation. From cross spectra measurement during the scan, a principal component representing the sound field is extracted. Any power descriptor of the near field can then be investigated by means of near-field acoustic holography, while the distant field can be determined by application of Helmholtz integral equation. The results of the measurement were used to obtain the radiation sound pattern from the center line of the tire, and to locate the radiation sound generating regions in the vicinity of the tire.

  • PDF

Vibration Characteristics Analysis of Boom Sprayer for Upland-use Using Frequency Analysis (주파수 분석을 이용한 전작용 붐방제기의 진동 특성 분석)

  • 김영주;이중용
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2003.02a
    • /
    • pp.244-250
    • /
    • 2003
  • 국내에 보급된 방제기는 인력분무기, 동력 분무기, 동력 살분무기, 스피드 스프레이어, 붐방제기 등이 있다. 그 중 동력경운기에 탑재하거나 트랙터에 견인되는 동력분무기를 주축으로 기계화되어 있다. 작은 입경의 분무입자로서 가급적 적정량을 균일하게 뿌릴 때 방제효율을 높일 수 있는데도 불구하고, 동력분무기에 의한 액제 살포는 원거리 살포에 따라 분무입자의 입경 분포가 다양하며 대부분 분무입자가 매우 크므로 고른 살포를 기대하기 어렵기 때문에 약액을 1000대 1로 희석하여 흠뻑 적실 정도로 다량 살포를 하여 살포효율을 높이고 있다. 그러나 이러한 방제 방법은 효율성, 작업능률과 환경의 오염 측면에서 상당한 문제로 지적되고 있다. (중략)

  • PDF

The Smart Cane for the Visually-impaired using Ultrasonic sensors (초음파 센서를 이용한 시각 장애우용 스마트 케인)

  • Park, Cha-Hun;Ahn, Hyun-Jin;Lee, Jae-ik;Song, Kwang-ho;Kim, Ha-hyung;Jung, Sang-chan
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2021.01a
    • /
    • pp.181-182
    • /
    • 2021
  • 시각장애인이 길거리에 나설 때 주변에 보행 안전을 위한 시설이 많이 부족하다. 본 연구에서는 시각장애인에게 전방의 장애물을 알려주어 안전한 보행을 위한 스마트 지팡이를 제안한다. 초음파센서를 통하여 사물을 감지하여 진동으로 보행자의 진로 방향을 안내하며 조도 센서를 통하여 다른 사람들이 원거리에서 인식 할 수 있게 발광 기능을 포함한다. 또한, 긴급버튼을 통하여 비상시 보호자에게 알릴 수 있는 통보기능도 내장하고 있다. 향후 소형화와 지능화를 통하여 사회적 약자인 시각장애인의 안전한 보행권을 확보할 수 있는 기술로 발전시키고자 한다.

  • PDF