• Title/Summary/Keyword: 운전 pH

Search Result 325, Processing Time 0.048 seconds

The Electro-Chemical Treatment for Nitrogen Removal of Metal Finishing Wastewater (질소제거를 위한 금속표면처리폐수의 전기화학적 처리)

  • Sim, Joo-Hyun;Seo, Hyung-Joon;Kim, Dae-Hwan
    • Korean Chemical Engineering Research
    • /
    • v.45 no.2
    • /
    • pp.190-196
    • /
    • 2007
  • This study examined the nitrate removal efficiency which uses an electrowinning, and also analyzed the nitrate removal efficiency under a variety of operating conditions such as nitrate concentrations, pH, current densities, electrodes, reducing agents in order to determine optimal conditions. In addition, the multi-step electro-chemical process test has been also analyzed. During the electrowinning, the identical Zn-Zn and Pt-Ti electrodes in the insoluble oxidation electrode(Pt) has shown the highest nitrate removal efficiency in the 100 mg $NO_3^{-}$ -N/L concentration. In the concentration of 150 mg $NO_3^{-}$ -N/L, the efficiency of the Zn-Zn electrode were 70~85%, and that of Pt-Ti electrode were 40~50% without any change of pH. In the high concentration of 500 and 1,000 mg $NO_3^{-}$ -N/L, the higher the concentration, the more decrease of its nitrate removal efficiency decreased. However, the energy consumed for nitrogen removal increased when the nitrate concentration was high. As a result of the multi-step electro-chemical process test, We chose the Test 4. Because the first, most of the zinc consumed from 1 step was recovered from over the 2 step. The second, amount of consumption anode decreased with insoluble anode Pt from over the 2 step. And the third, Zn cathode increased the possibility of reusing Zn deposited. In view of the results so far achieved, the multi-step electro-chemical process would be applied to treat nitrogen involved in metal finishing wastewater.

Effect of Operational Parameters on the Ammonia Stripping (암모니아 스트리핑에 미치는 운전인자의 영향)

  • Seo, Jeong-Beom;An, Kwang-Ho
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.9
    • /
    • pp.935-939
    • /
    • 2006
  • The biological nutrient removal from domestic wastewater with low C/N ratio is difficult. Therefore, this study was performed to examine effect of operational parameters such as air supply, hydraulic retention time, pH on the nitrogen removal by ammonia stripping and to increase influent C/N ratio without required carbon source. The ammonia stripping system used for the bench-scale experiment in laboratory had a dimension of 15 cm diameter and 150 cm height. The ammonia stripping reactors were classified into two types, type AS I and type AS II, according to there using or not media. Results of the research showed that the T-N removal efficiency of AS I using plastic media is slightly higher than AS II without media. In experimental condition of air supply 30 L/min and pH 12.5, T-N removal efficiencies increased as HRT of ammonia stripping reactor became longer from 8 hr to 36 hr. In experimental condition of HRT 36 hr, it was also found that the T-N removal efficiencies improved through increase of air supply. On the other hand, C/N ratio of wastewater was increased from average 3.9 to 5.4 by ammonia stripping.

A Study of de-excitation improved equipment for compound-controlled rectifier excitation system (복권헝 여자시스템 De-excitation 설비개선에 관한 연구)

  • Lee, J.H.;Lim, I.H.;Ryu, H.S.;Shin, M.S.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.1181-1183
    • /
    • 2002
  • 전력수요의 증대로 발전소 운전에 핵심적인 역할을 담당하는 제어시스템의 중요성이 한층 더 강조되었다. 본 연구에서는 발전기 전압제어를 담당하는 여자시스템의 독특한 형태인 복권형 P-bar 여자시스템과 De-excitation 설비에 대하여 기술하고, Y원자력 발전소에서 경험하였던 De-excitation 설비에 계자방전 인덕터(FDI) 사용함으로써 발전기 계자권선에 축적된 에너지를 방전하는데 계자권선 시정수인 Tdo'이 설계치보다 너무 오래 지속되는 문제점을 검토하고, 이를 해결하기 위한 개선방안을 제시하였으며 이를 유사 발전소에 적용한 결과와 그 효용성을 보였다

  • PDF

The characteristic of operating the cogeneration system of 1kW PEMFC (1KW 고분자 연료전지의 열병합 발전 시스템 특성)

  • Choi, H.J.;Park, S.J.;Ha, M.H.;Cha, I.S.;Yoon, H.S.;Yoon, J.P.
    • Proceedings of the KIPE Conference
    • /
    • 2007.11a
    • /
    • pp.172-174
    • /
    • 2007
  • 본 연구는 가정용 연료전지 모니터링 사업을 통한 실증화 연구로써, 연료전지의 실용성에 대한 가치를 평가하고 실용화를 앞당기고자 하는데 목적을 두고 있다. 가정용 고분자 전해질 연료전지는 화학에너지를 전기에너지로 직접 변환함으로써 시스템 전체 효율이 80%이상의 고효율이고 환경 친화적이라는 점과, 연료전지 시스템의 운전 시 발생되는 폐열을 회수하여 급탕 및 난방용으로 활용함으로서 효율을 배가 시킬 수 있다는 장점 또 쉽게 구할 수 있는 LPG, LNG를 연료로 한다는 점을 특징으로 한다. 본 연구는 1kW 가정용 연료전지를 직접 구동하고 모니터링 함으로써 발생되는 문제점과 열병합 발전 시스템에 대한 연구를 진행하였다.

  • PDF

Fermentative Hydrogen Production under Various $SO_4^{2-}$ Concentration using Anaerobic Mixed Microflora (혐기 혼합균주에서 황산염 농도변화에 따른 수소 발효 특성)

  • Hwang, Jae-Hoon;Choi, Jeong-A;Lee, Jong-Hak;Jeong, Tae-Young;Cha, Gi-Cheol;Song, Ho-Cheol;Yong, Bo-Young;Kim, Dong-Jin;Jeon, Byong-Hun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.6
    • /
    • pp.434-441
    • /
    • 2009
  • The effect of varying sulfate concentration on continuous fermentative hydrogen production was studied using enriched mixed microflora in continuously fed reactor. Glucose was used as a model substrate for carbohydrates, and hydraulic retention time (HRT) was maintained at 1, 0.5, 0.25 day, respectively. Sulfate concentration was 0${\sim}$20,000 mg/L and the operating pH was maintained at 5.5. The experimental results indicate that hydrogen production is not affected by high sulfate concentration and shorter HRT of 0.25 day enhance hydrogen production. At HRT 1, 0.5, 0.25 day, the hydrogen production rate and hydrogen yield were 2.6, 4.6, 9.4 L/day, and 2.0, 1.8, 1.6 mol $H_2$/mol glucose, respectively. Residual sulfate content was 96${\sim}$98, 95${\sim}$97, and 94${\sim}$97% at HRT 1, 0.5, 0.25 day which show that no sulfate reduction occurred in the reactor during the experiments. Results of Fluorescence In Situ Hybridization (FISH) may indicate the presence of HPB (hydrogen producing bacteria) under all experimental conditions. However, SRB (sulfate reducing bacteria) were not found.

Phosphorus Removal and Operating Performance of Mesh Filtration Bio-reactor with the Addition of Alum (Alum 주입 메쉬 침지 여과분리형 생물반응조의 운전 특성과 인 제거)

  • Jung, Yong-Jun;Min, Kyung-Sok
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.5
    • /
    • pp.458-463
    • /
    • 2005
  • Considering the characteristics of a filtration bio-reactor equipped with a mesh filter module which can effectively maintain high concentration of biomass and enhanced solid-liquid separation performance, the hybrid process of filtration bio-reactor combined with coagulation was investigated to get improved filtration characteristics as well as water quality in this work. Two bio-reactors (Run-1 & Run-2) were operated under the following conditions: working volume of 25 L, continuous loading of a synthetic wastewater (BOD: 200 mg/L, T-N: 50 mg/L, T-P: 5 mg/L), where an appropriate amount of alum ($Al_2(SO_4)_3{\cdot}18H_2O$) was added once a day into the reactor (Run-2). In the system without using a alum (Run-1), the clogging of mesh filter module was observed two times through 85 days of whole operation. Meanwhile, the filter module did not clog even at higher MLSS concentration (6,000~12,000 mg/L) and the stable filtration (0.7 mid) was continued in the case of using a alum. Due to the stable formation of cake layers, BOD and SS were shown below 6 and 3 mg/L, respectively. T-P and pH of the effluent were changed because of the intermittent addition of the alum. In the case of Al/P=2.5, the average T-P removal efficiency per day was 85.2% and the average T-P concentration of the effluent was 0.3 mg/L. However, the removal efficiency of phosphate was influenced by pH in the reactor.

A Study of Heavy Metal-Contaminated Soil Remediation with a EDTA and Boric acid Composite(II): Cd and Cr (EDTA와 붕산 혼합용출제를 이용한 중금속으로 오염된 토양의 처리에 관한 연구(II): 카드뮴 및 크롬)

  • Lee Jong-Yeol;Kim Yong-Soo;Kwon Young-Ho;Kong Sung-Ho;Park Shin-Young;Lee Chang-Hwan;Sung Hae-Ryun
    • Journal of Soil and Groundwater Environment
    • /
    • v.9 no.4
    • /
    • pp.8-14
    • /
    • 2004
  • To investigate the optimal operation factors in appling Soil Flushing Process, which use EDTA and boric acid composite as a flushing reagent, to the Cd(cadmium) and Cr(chromium) contaminated sites, Cd and Cr emediation rate was investigated at various experimental conditions; as EDTA concentration was increased from 0.001M to 0.1M, Cd remediation rate was increased from $73.2\%\;to\;98.5\%$; as boric acid concentration was increased from 0.001M to 0.1M, Cr remediation rate was increased from $59.2\%\;to\;99.0\%$. In the experiments using 0.005M of EDTA and 0.005M of boric acid composite as a flushing reagent at different pH regimes, Cd remediation rate was decreased from $92.4\%\;to;80.9\%$ as the pH was increased from 3 to 7. But Cr remediation rate was more effective ($70.4\%$) at pH 5 compared to the other pHs. Furthermore, at pH 5, Cd and Cr remediation rate was investigated at different molecular ratio of [EDTA]/[Boric aicd]; the optimized [EDTA]/[Boric acid] ratio was 0.01M/0.1M for Cd contaminated site and, as the concentration of boric acid was increased over 0.1M, Cr remediation rate was also increased. So the similar results were shown in the experiments using real contaminated soils which were sampled from a mining and a industrial area.

The Characteristics of Carbon Dioxide Fixation by Chlorella sp. HA-1 in Semi-continuous Operation (반연속식 운전에서 Chlorella sp. HA-1의 이산화탄소 고정화 특성)

  • Lee, Jae-Young;Kang, Hyun-Ah;Yang, Ji-Won
    • KSBB Journal
    • /
    • v.14 no.6
    • /
    • pp.742-746
    • /
    • 1999
  • The microalgal, Chlorella sp. HA-1, had good $CO_2$ fixation efficiency compared to other algal strains at the same operating condition. In this study, Chorella sp. HA-1 showed similar tolerance both 10% and 20% $CO_2$ concentration. By optimization of the major operation variables such as pH, initial cell concentration, light intensity, the $CO_2$ fixation rate could be raised to a reasonably high value, 372 $gCO_2/m^2{\cdot}day$ in a 3 L internally illuminated photobioreactor. In order to maintain the $CO_2$ fixation rate for a long time, the method of semi-continuous operation was employed, in which dilution ratio was the controlling parameter. Starting with the dilution ratio of 0.5 with the increased increment of 0.1, the constant $CO_2$ fixation rate was obtained.

  • PDF

A study on the comparison of coated nitrifying bacteria on nitrification efficiency and distribution of nitrifying bacteria

  • Kwon, Hyun-Jin;Yoon, Joung-Yee;Chae, Jong-San;Kim, Dong-Jin
    • 한국생물공학회:학술대회논문집
    • /
    • 2005.10a
    • /
    • pp.434-438
    • /
    • 2005
  • Nitrification characteristics and performance of wastewater treatment plants depend on not only temperature, pH, and dissolved oxygen of the wastewater but also species, distribution, and their metabolic stages of nitrifying bacteria. Due to their low specific growth rate, nitrifying bacteria are easy to wash out of the reactor and need long time to start-up and recover from damaged nitrifiers community. In order to overcome this limitation, nitrifying bacteria were coated on a polyurethane-based media. Laboratory and pilot-scale reactor had been designed and operated to compare the effect of coated nitrifying bacteria on wastewater nitrification efficiency and performance. Furthermore, the species and quantitative distribution of nitrifying bacteria were also investigated in the suspension and on the media. The results showed that nitrifier-coated reactor had better nitrification efficiency and performance than the control experiments. It also demonstrated that the amounts of total nitrifying bacteria of a coated reactor was higher than other reactors and it increased with operation time and wastewater temperature.

  • PDF

Water Treatment of Seawater Recirculating Aquaculture System by Using Three Phase Fluidized Bed Reactor (삼상 유동층 반응조를 이용한 해수 순환 여과 시설의 수처리)

  • Lee, Byung-Hun;Choi, Hyeok;Ryu, Jong-Soo
    • Journal of Aquaculture
    • /
    • v.13 no.2
    • /
    • pp.137-145
    • /
    • 2000
  • Capacity of water treatment of the three phase fluidized bed reactor as a biofilter in the seawater recirculating system was evaluated. The water treatment system consists of fluidized bed reactor for ammonia removal, cartridge filter for solid removal and ozone contactor for disinfection. Mean concentration of water quality parameters: COD, TAN, $NO_2$-N, $NO_3$-N, SS and alkalinity were 9.0, 0.22, 0.05, 20.0, 9.5 and 70.0 mg/l, respectively; the relevant values were 7.6 for pH and 3.64 NTU for turbidity. These indicate the maintenance of good water quality by the treatment system. The influent TAN loading rate in to the fluidized bed reactor ranged from 4.3 to 32.9 g/$m^3$/day, and averaged to 20 g/$m^3$/day. TAN removal efficiency of each phase of the fluidized bed reactor was 47-60%, indicating the effective ammonia removal. During operation the effluent of fluidized bed reactors also maintained the unionized ammonia nitrogen level below 0.002 mg/l.

  • PDF