• Title/Summary/Keyword: 운전 스트레스

Search Result 63, Processing Time 0.039 seconds

A Study on Feedback Queue Generation Method in Police Motorcycle Simulator System (경찰 오토바이 시뮬레이터 시스템에서 피드백 큐 생성 방법에 관한 연구)

  • Ahn, Dong-Hyuk;Cho, Sung-Hyun;Jeong, Yang-Kwon
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.13 no.4
    • /
    • pp.827-836
    • /
    • 2018
  • In this study, we developed a PC - based motorcycle simulator based on the development technology of a virtual patrol motorcycle training system. This simulator has been developed to be applied to a variety of fields such as driving training for beginners, driver factor research, and system development such as ABS, which can be seen in advanced models. The weight of the motorcycle operated by the patrol guards is more than 400Kg. There is a lot of risk due to the nature of work without prior practice. Therefore, we implemented a study on the untilization of physical stress and temporal pressure in emergency situations. In order to get a feeling that the motorcycle simulator is operating in real-life, it is important that the mutual reliable signal transmission and operation feel between the driver and the simulator. In order to achieve this, we developed a system that can apply the sub-systems of the actual vehicle to the motorcycle simulator in order to generate the same operation feeling as the actual vehicle. Based on these results, we have developed a method of generating a feedback queue.

Development of TRAIN for Accident Management (중대사고관리를 위한 훈련도구(TRAIN)의 개발)

  • Moo-Sung Jae
    • Journal of the Korean Society of Safety
    • /
    • v.16 no.1
    • /
    • pp.84-87
    • /
    • 2001
  • Severe accident management can be defined as the use of existing and alternative resources, systems, and actions to prevent or mitigate a core-melt accident in nuclear power plants. TRAIN (Training pRogram for AMP In NPP), developed for training control room staff and the technical group, is introduced in this paper. The TRAIN composes of phenomenological knowledge base (KB), accident sequence KB and accident management procedures with AM strategy control diagrams and information needs. This TRAIN might contribute to training them by obtaining phenomenological knowledge of severe accidents, understanding plant vulnerabilities, and solving problems under high stress.

  • PDF

Review on the Electromagnetic Force of Underground Cable According to the Cleat Distance (클리트 간격에 따른 지중케이블 전자력 영향 검토)

  • Kang, J.W.;Park, H.S.;Jang, T.I.;Tark, E.G.;Kim, Y.S.;Keon, J.G.;Lee, K.S.;Jang, W.S.
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.2091_2092
    • /
    • 2009
  • 지중케이블 시스템에서의 고장은 필연적으로 대전류 현상을 수반하는 경우가 대부분으로서 고장전류는 고장 케이블 자체와 인접해 있는 타 선로 및 통신선 등에 악영향을 미칠 가능성이 크고, 초고압 케이블의 운전전압 레벨이 지속적으로 증가하고 있는 상황에서 사고의 파급 및 위험정도 또한 지속적으로 증가하고 있다. 특히, 단락 고장의 경우 고장전류의 크기도 크지만 고장전류 발생에 따른 전자력을 동반하게 되어 케이블 및 접속함, 각종 금구류에 전기적, 기계적인 스트레스를 야기할 수 있다[1]. 따라서 본 논문에서는 지중케이블의 삼각배열 구간의 단락전자력 영향을 최소화하기 위한 방안을 모색하기 위하여 154kV OF케이블 3상 단락 실증시험을 2회 시행하였고, 유한요소법을 이용하여 단락전자력 발생시 클리트 설치간격에 따른 케이블 변위를 계산함으로써 케이블의 단락 전자력 영향 검토결과를 기술하였다.

  • PDF

A Study on Fatigue Assessment of the Crane Post due to Vibration during the Emergency Stop (충격하중에 의한 Jib Crane Post의 피로 수명 평가)

  • Kim, Kuk-Su;Kim, Nho-Seong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2011.04a
    • /
    • pp.633-637
    • /
    • 2011
  • The tall and slender main crane is generally installed on the upper deck to load and unload the equipment or something heavy in the drilling rig or the ship. So the natural frequency of the crane equipment is very low, therefore, there is some possibility of excessive vibration at the emergency state due to sudden stop during the crane operation. This study describes a fatigue assessment due to heavy vibration during brake test of sudden stop because it is necessary the safety of crane is estimated against the heavy vibration. In order to find out the applied force, the vibration measurement and analysis have been performed.

  • PDF

The Factors Related to Musculoskeletal Symptoms of Male Taxi Drivers (남성 택시 운전원의 근골격계 자각증상에 영향을 미치는 요인)

  • Eum, Mi-Jung;Jung, Hye-Sun
    • Korean Journal of Occupational Health Nursing
    • /
    • v.23 no.4
    • /
    • pp.227-234
    • /
    • 2014
  • Purpose: This study was conducted to understand the subjective symptom rate of musculoskeletal disease of male taxi drivers and comprehend general features, health behavior features, and factors related to the subjective symptoms of musculoskeletal system depending on the level of job stress. Methods: The participants were 206 male taxi drivers from 4 transportation companies in the Seoul and Gyeonggi areas. The investigation was conducted from July 20th 2012 to August 20th 2012 through a self-administered questionnaire survey. Results: The participants who exercised less than three times per week complained about the subjective symptoms of the musculoskeletal system (p=.016) 13.770 times as more as than those of the participants who exercised more than three times per week the participants who had a higher level of job stress complained about the subjective symptoms of the muscular skeletal (p=.011) 1.051times as more as than those who had a relatively lower level of job stress. Conclusion: This study recommends that it is necessary to provide exercise programs and arrange various plans reducing job stress to prevent muscular skeletal disease and minimize the disease susceptibility of taxi drivers.

Field Application of H-Bridge Multi-level Inverter for Fluidized Bed Combustion Boiler Secondary Air Fan (200MW 석탄화력 순환 유동층 보일러 이차공기송풍기용 H-브릿지 멀티레벨 인버터 현장적용)

  • Kim, Bong-Suck;Ryu, Ho-Seon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.12 no.5
    • /
    • pp.424-431
    • /
    • 2007
  • This thesis proposed H-Bridge Multi-Level Inverter for Fluidized Bed Combustion Boiler Secondary Air Fan in 200MW thermal power plant. The adjustable speed drive systems improve the efficiency in lightly load condition and extend the life span of motor by limiting the over current at starting. H-Bridge Multi-level Inverter is composed of the several series low voltage power cell inverters, which have the independent isolated do link, in each phase. KEPRI(Korea Electric Power Research Institute) has successfully completed to develop, install, and commission H-Bridge Multi-level Inverter(6.6kV, 1MVA). This thesis gives a full detail about H-Bridge Multi-level Inverter, proposed boiler DCS(Distributed Control System) logic, and commissioning test result.

A Comprehensive Review of PEMFC Durability Test Protocol of Pt Catalyst and MEA (수소연료전지 백금촉매 및 MEA 장기내구성 평가 방법의 비교)

  • Ham, Kahyun;Chung, Sunki;Lee, Jaeyoung
    • Applied Chemistry for Engineering
    • /
    • v.30 no.6
    • /
    • pp.659-666
    • /
    • 2019
  • Proton exchange membrane fuel cells (PEMFCs) generate electricity by electrochemical reactions of hydrogen and oxygen. PEMFCs are expected to alternate electric power generator using fossil fuels with various advantages of high power density, low operating temperature, and environmental-friendly products. PEMFCs have widely been used in a number of applications such as fuel cell vehicles (FCVs) and stationary fuel cell systems. However, there are remaining technical issues, particularly the long-term durability of each part of fuel cells. Degradation of a carbon supported-platinum catalyst in the anode and cathode follows various mechanistic origins in different fuel cell operating conditions, and thus accelerated stress test (AST) is suggested to evaluate the durability of electrocatalyst. In this article, comparable protocols of the AST durability test are intensively explained.

Analysis on the Effect of Filter to Mitigate Transient Overvoltage on the High Voltage Induction Motor Fed by Multi Level Inverter using EMTP (EMTP를 이용한 멀티레벨 인버터 구동 고압유도전동기에서 발생하는 과도과전압 저감필터의 효과분석)

  • Kwon, Young-Mok;Kim, Jae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.10
    • /
    • pp.82-93
    • /
    • 2006
  • In this paper, filters are designed to reduce transients overvoltage in inverter fed high-voltage large-capacity induction motor drive system. Design issues for a LCR filter at the inverter output terminals to reduce the dv/dt of the inverter output pulse and a RC filter at the induction motor input terminals to match the characteristic impedance between cable and induction motor are examined in detail. These filters are modeled to be suitable to high-voltage large-capacity induction motor. The performance of the filter is evaluated through simulation using EMTP(ElectroMagnetic Transients Program). We presented filters that used high voltage large-capacity induction Motor on the basis of this. Effect of the filter is analyzed for variation of the cable length. Characteristics of filters are analyzed to reduce harmonic in voltage waveform of induction motor input terminal. The switching surge voltage became the major cause to occur the insulation failure by serious voltage stress in the stator winding of induction motor. Filter for to mitigate transients overvoltage presents a required component in drive system of high-voltage large-capacity induction motor. Also, proposed filters are proved through simulation using EMTP.

A Novel Fault Detection Method of Open-Fault in NPC Inverter System (NPC 인버터의 개방성 고장에 대한 새로운 고장 검출 방법)

  • Lee, Jae-Chul;Kim, Tae-Jin;Hyun, Dong-Seok
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.12 no.2
    • /
    • pp.115-122
    • /
    • 2007
  • In this paper, a novel fault detection method for fault tolerant control is proposed when the NPC inverter has a open failure in the switching device. The open fault of switching device is detected by checking the variation of a leg-voltage in the neutral-point-clamped inverter and the two phases control method is used for continuously balance the three phases voltage to the load. It can be achieve the fault tolerant control for improving the reliability of the NPC inverter by the fault detection and reconfiguration. This method has fast detection ability and a simple realization for fault detection, compared with a conventional method. Also, this fast detection ability improved the harmful effects such as DC-link voltage unbalance and overstress to other switching devices from a delay of fault detection. The proposed method has been verified by simulation and experiment.

The Development of Life Evaluation Program for LNG Storage Tank considering Fatigue and Durability (피로 및 내구성을 고려한 LNG 저장탱크의 수명평가 프로그램 개발)

  • Kim, Jung-Hoon;Kim, Young-Gu;Jo, Young-Do
    • Journal of the Korean Institute of Gas
    • /
    • v.21 no.3
    • /
    • pp.39-45
    • /
    • 2017
  • The LNG storage tank as core facility of LNG industry is mainly composed of the inner tank of nikel 9% steel and the outer tank of prestressed concrete. To respond proactively increased risk of structure performance deterioration due to fatigue of the inner tank and durability reduction of the outer tank, life evaluation program for LNG storage tank is needed. In this study, life evaluation program for LNG storage tank was developed to assess fatigue of the inner tank and durability(carbonation and chloride attack) of the outer tank. By defining the main three scenarios in the inner tank, the fatigue life analysis is conducted from structural analysis and Miner's damage rule. Carbonation progress of the outer tank is predicted according to thickness of cover concrete by using carbon dioxide contents and data of penetration depth. To consider a variety of input conditions and a reliability in results of chloride attack, the evaluation of choride attack for the outer tank is constructed through Life-365 program of open source.