A Study on the Optimal Bilateral Heat Transaction of CHP considering the Operation Modes (운전모드를 고려한 열병합발전의 열거래 최적운전)

  • Kim, Yong-Ha;Woo, Sung-Min;Back, Bum-Min;Lee, Pyong-Ho;Kim, Young-Gil
    • Journal of Energy Engineering
    • /
    • v.18 no.1
    • /
    • pp.37-48
    • /
    • 2009
  • Recently, the significance of Green-Energy led by low-carbon Green-Development is increasing as well in Korea. Among them, the most practical solution is the cogeneration which performs the best energy efficiency. This paper addresses the two of RCS(Regional Cogeneration System) connecting heat each other. It is conducted to quantitatively evaluate algorithm that optimally operate the heat transaction considering various operating modes. The proposed method is tested using the real system. Through the case studies, it is verified that the proposed algorithm of heat transaction can evaluate availability.

A Seamless and Autonomous Mode Transfer Method of Bidirectional Grid Connected Inverter in Microgrid. (마이크로그리드에서 양방향 계통연계형 인버터의 자율적이며 끊김없는 모드전환 기법)

  • Park, Sungyoul;Kwon, Minho;Shin, Yangjin;Jung, Hoyoung;Kang, Suhan;Choi, Sewan
    • Proceedings of the KIPE Conference
    • /
    • 2018.07a
    • /
    • pp.36-38
    • /
    • 2018
  • 중요부하를 가지고 있는 계통연계 인버터는 계통과의 연결이 끊길 경우 중요부하에 안정적인 전압공급을 위하여 끊김 없는 모드전환 동작이 요구된다. 기존 인버터는 계통연계 시 전류제어모드, 독립운전 시에는 전압제어모드로 운전을 한다. 그래서 모드전환 시 제어기절체로 인한 출력전압에 심각한 과도상태가 발생할 수 있으며 단독운전 검출 전에도 불안정한 전압을 부하에 공급하게 되어 중요부하에 큰 손상을 입힐 수 있다. 본 논문에서는 LCL필터 뿐만 아니라 LC필터 구조에서도 적용이 가능하며, 양방향 운전 시 자율적인 모드전환이 가능한 계통연계 인버터의 모드전환 기법을 제안한다. 제안된 알고리즘은 5kW 시작품을 제작하여 타당성을 검증하였다.

  • PDF

Flyback Converter Operation in Critical Conduction Mode (플라이백 컨버터의 경계점 모드 운전에 관한 연구)

  • Kim, H.Y.;Woo, J.S.;Jung, H.J.;Kwon, Y.A.
    • Proceedings of the KIEE Conference
    • /
    • 2005.10c
    • /
    • pp.205-207
    • /
    • 2005
  • 플라이백 컨버터의 경계점 도통 모드 운전은 변압기의 자화인덕턴스 전류를 연속과 불연속의 경계에서 도통시킴으로써 기존의 고정주파수 컨버터에서 소프트 스위칭을 위하여 사용하였던 별도의 스위치나 보조회로를 추가하지 않으면서 전력소자의 소프트 스위칭을 가능하게 하는 장점을 가진다. 본 논문에서는 스위치의 온 오프시 변압기의 인덕턴스와 스위치의 기생 커패시터 성분이 일으키는 공진구간을 전체 스위칭 주기에 포함시킴으로써 경계점 도통 모드 운전에서 부하출력에 따른 스위칭 주파수의 변화를 보다 정확히 제시하고 이를 바탕으로한 정상상태모델링을 통하여 경계점 도통 모드 플라이백 컨버터의 여러 운전 특성을 분석하였다.

  • PDF

A Wind Turbine Simulator for Doubly-Fed Induction-type Generator with Automatic Operation Mode Change during Wind Speed Variation (가변 풍속시 운전모드 절환을 고려한 이중여자 유도형 풍력발전기의 시뮬레이터)

  • Song, Seung-Ho;Sim, Dong-Joon;Jeong, Byoung-Chang
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.11 no.4
    • /
    • pp.349-360
    • /
    • 2006
  • Controller for doubly-fed induction-type wind generation system should be designed with mechanical power on blade. The controller in this paper consists of upper level controller and lower level controller. The upper level controller determines operating modes according to mechanical input power and calculates proper reference values. There are 4 operating modes - minimum speed control, variable torque control, torque limit control and idle mode. The lower level controller performs current regulated PWM control of rotor-side converter and grid-side inverter. A wind turbine simulator is implemented using doubly-fed induction-type generator and DSP based back-to-back converter to verify the performance of designed controller experimentally.

Output Control of ITER Vertical Stabilization Converter with Circulating Current Technique (순환전류를 이용한 ITER Vertical Stabilization 컨버터의 출력 제어)

  • Chung, Gyo-Bum;Ji, Jun-Keun;Mok, Hyung-Soo
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.14 no.5
    • /
    • pp.379-386
    • /
    • 2009
  • This paper investigates the operation of ITER(International Thermonuclear Experimental Reactor) Vertical Stabilization(VS) converter with circulating current. The VS converter has two subunits in parallel. The subunit is composed two back-to-back 12 pulse thyristor converter in series. The circulating current free technique can not always maintain the closed path for the load current because of a dead time zone of the converter operation at the region of the load current inversion. The complex circulation current technique for the load current inversion with VS converter can achieve the fast response and always maintain the closed path for the load curret. The paper proposes the new circulating current algorithm for the load current inversion of ITER VS converter and proves the performance of the circulating current technique with PSIM simulation study.

Comparison of effectiveness of Aeration Modes on the Removal of Landfill Gases for Landfill Mining (폐기물매립지 굴착사업을 위한 가스치환시 공기공급방법의 효율성 비교)

  • 남궁완;박준석;김정대
    • Journal of Korea Soil Environment Society
    • /
    • v.3 no.2
    • /
    • pp.79-88
    • /
    • 1998
  • The purpose of this study was to estimate the removal potential of landfill gases during landfill mining project. Air injection mode and landfill gas extraction mode were tested. A mode that air injected at one injection well and landfill gas extracted at another extraction well at the same time was also tested to compare. The flow rates of all modes were the same as 15$\textrm{km}^2$/min. Air injection mode was the most effective in removing $CH_4$. Air injection/extraction mode didn't improve the effectiveness of removing CH$_4$compared with air injection mode. Air injection mode were more advantageous than air injection/extraction mode in respect to energy consumption because that of air injection/extraction mode were doubled.

  • PDF

Virtual impedance based droop control for proper power sharing of parallel inverters in islanded microgrid (마이크로그리드 독립운전 시 병렬 운전 인버터의 적절한 전력분담을 위한 가상임피던스 기반의 드룹제어 연구)

  • ko, Seungwoo;Lim, Kyungbae;Choi, Jaeho
    • Proceedings of the KIPE Conference
    • /
    • 2016.07a
    • /
    • pp.125-126
    • /
    • 2016
  • 여러 분산 발전 시스템으로 구성된 마이크로그리드는 계통연계 모드에서 부하의 수요에 담당하게 되고, 계통 사고가 발생할 시 독립 운전 모드로 동작을 해야 한다. 본 논문에서는 독립운전 모드 동작 시 제어 방식 중에서 유, 무효 전력제어를 통한 적절한 전력 분담을 실현하기 위한 드룹제어 방식을 다룬다. 이 방식은 선로 임피던스가 복합 성분으로 구성되어 있거나 불 평형 일 경우 여러 문제로 유,무효 전력 분담의 오차를 발생 시킨다. 이에 대하여 가상임피던스를 추가함으로써, 복합적 불 평형 임피던스에 기인한 유,무효 전력 분담의 오차를 해결 하여, 시스템의 유,무효 전력 분담을 개선 하고자 하였다. 가상 임피던스에 따른 출력 임피던스에 대해서 연구하고 이에 따른 드룹제어를 분석하고, PSIM 시뮬레이션을 이용하여 검증하였다.

  • PDF

Design and analysis of the parallel inverters using virtual capacitive-resistive complex impedance in islanded mode (독립 운전 모드 시 가상 캐패시터-저항 복합 임피던스를 이용한 인버터 병렬 운전 설계 및 분석)

  • Jung, Kyosun;Lim, Kyungbae;choi, Jaeho
    • Proceedings of the KIPE Conference
    • /
    • 2014.11a
    • /
    • pp.145-146
    • /
    • 2014
  • 여러 가지 분산 발전 시스템들은 마이크로그리드의 형태를 지니고 있다. 이 마이크로그리드는 계통연계모드에서 부하의 수요를 담당하게 되고, 계통 사고가 발생할 시 단독운전모드로 동작을 해야 한다. 드룹 제어 방식은 이 때 각각의 분산발전시스템에서의 유효전력과 무효전력 부하 sharing을 통해 안정적으로 전력을 공급 할 수 있고 순환 전류를 최소화 할 수 있다. 본 논문에서는 제안된 가상 저항과 캐패시터를 이용하여 인버터 병렬 운전 시스템을 위한 드룹 제어에 대해서 연구하였다. 그리고 가상 복합 임피던스에 따른 출력 임피던스에 대해서 연구하고 이에 따른 드룹 제어를 분석하여 PSIM 시뮬레이션으로 이를 검증하였다.

  • PDF

Transient Stability Enhancement under Microgrid Environment using P-w Droop Control for Inverter-based Distributed Generation (마이크로그리드 환경에서 인버터기반 분산전원의 P-w 드룹 제어를 통한 과도안정도 향상 대책)

  • Lee, Young-Woo;Kim, Seung-Wan;Jin, Young-Gyu;Yoon, Yong-Tae
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.149-150
    • /
    • 2015
  • 소규모 분산전원 및 에너지 저장장치로 구성된 마이크로그리드는 에너지 자급자족이 가능한 특징을 가지며 계통연계 혹은 독립운전 모드로 운전이 가능하다. 마이크로그리드를 계통연계 모드로 운전하는 경우, 상위 계통에서 사고 발생 시 마이크로그리드 내 동기기의 과도안정도 문제가 발생할 수 있다. 이 때 인버터 기반 분산전원의 빠른 응답 속도를 활용하면 인접 동기기의 유효출력을 효과적으로 제어하여 계통연계 모드를 유지하면서도 과도안정도를 유지할 수 있다. 본 연구에서는 인버터 기반 분산전원의 P-w 제어를 통해, 정상 운전시에는 정해진 전력을 공급하면서 사고 시에는 인접 동기기의 과도안정도를 향상시킬 수 있는 제어 방법을 제안하였다. 또한 실제 적용 가능성을 확인하기 위해 ATP/EMTP프로그램을 이용하여 계통을 구성하고 해석하였다.

  • PDF