• Title/Summary/Keyword: 운동과 에너지 영역

Search Result 127, Processing Time 0.027 seconds

Characteristics of Temperature in Reformer Tube and Chemical Reaction for Steam Methane Ratio (수증기-메탄 혼합비에 따른 개질 튜브 내 온도 및 화학반응 특성)

  • Han, Jun Hee;Kim, Ji Yoon;Lee, Seong Hyuk
    • Journal of the Korean Institute of Gas
    • /
    • v.20 no.5
    • /
    • pp.27-33
    • /
    • 2016
  • The aim of numerical study is the investigation of the solid and fluid temperatures in a reformer tube and chemical reaction characteristics of different steam-carbon ratio. We considered conjugate heat transfer contain radiation, convection and conductive heat transfers. This is because steam reforming reaction of hydrocarbon occurred high temperature conditions up to 800 K- 1000 K by using commercial computational fluid dynamics (CFD) code (Fluent ver. 13.0). For numerical simulation, the Reynolds-Averaged Navier-Stokes, momentum and energy equation were employed. In addition, inside of reformer tube is assumed as the porous medium to consider the Nichrome-based catalyst. To analysis characteristics of tube temperature in chemical reaction, we changed steam-methane ratio(SCR) from 1 to 6. As increased SCR, the higher tube temperature and methane conversion were observed. It was obtained that the highest hydrogen production held in SCR of 5.

Numerical Analysis of Thermal and Flow affected by the variation of rib interval and Pressure drop Characteristics (리브 간격 변화에 따른 열.유동 수치해석 및 압력 저하 특성)

  • Chung, Han-Shik;Lee, Gyeong-Wan;Shin, Yong-Han;Choi, Soon-Ho;Jeong, Hyo-Min
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.5
    • /
    • pp.616-624
    • /
    • 2011
  • The flow characteristics and heat transfer augment on the periodically arranged semi-circular ribs in a rectangular channel for turbulent flow has been investigated numerically. The aspect ratio of the rectangular channel was AR=5, the rib height to hydraulic diameter ratio were 0.07 and rib height to channel height ratio was set as e/H=0.117 for various PR(rib pitch-to-rib height rate) between 8~14, respectively. The SST k-${\omega}$ turbulence model and v2-f turbulence model were used to find out the heat transfer and the flow characteristics of near the wall which are suited to obtain realistic phenomena. The numerical analysis results show turbulent flow characteristics, heat transfer enhancement and friction factor as observed experimentally. The results predict that turbulent kinetic energy(k) is closely relative to the diffusion of recirculation flow. and v2-f turbulence model simulation results have a good agreement with experimental values.

Dynamic Simulation of the Water-steam System in Once-through Boilers - Sub-critical Power Boiler Case - (관류보일러 물-증기 계통의 동적 시뮬레이션 - 아임계 동력보일러 사례 -)

  • Kim, Seongil;Choi, Sangmin
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.41 no.5
    • /
    • pp.353-363
    • /
    • 2017
  • The dynamics of a water-steam system in a once-through boiler was simulated based on the physics-based modeling approach, representing the system in response to large load change or scale disturbance simulations. The modeling considered the mass, energy conservation, and momentum equation in the water pipe and the focus was limited to the sub-critical pressure region. An evaporator tube modeling was validated against the reference data. A simplified boiler system consisting of economizer, evaporator, and superheater was constructed to match a 500 MW power boiler. The dynamic response of the system following a disturbance was discussed along with the quantitative response characteristics. The dynamic response of the boiler system was further evaluated by checking the case of an off-design point operation of the feedwater-to-fuel supply ratio. The results re-emphasized the significance of controlling the feedwater-to-fuel supply ratio and additional design requirements of the water-steam separator and spray attemperator.

Discovery of Sub-pc Scale Plasma Torus in the Nearby Radio Galaxy 3C 84 with the KVN and VERA Array (KaVA)

  • Wajima, Kiyoaki;Kino, Motoki;Kawakatu, Nozomu
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.41 no.2
    • /
    • pp.32.4-33
    • /
    • 2016
  • 활동성은하핵(AGN)의 거대 블랙홀 주변에 존재하는 플라스마 디스크의 구조나 물리적인 상태를 관측으로 직접 찾는 것은 AGN 중심부분에서의 제트 형성, 방출과정이나 에너지 수송과정을 조사하기 위해 중요한다. 지금껏 주로 센치미터파장 영역의 다주파 VLBI 관측으로 우리은하에서 가까운 AGN 속에 존재하는 10 pc 정도의 플라스마 디스크가 발견되어 있다만, AGN의 활동성을 정하고 있는 1 pc 이하의 스케일에서의 디스크 구조를 직접 관측한 결과는 아직 없다. 우리는 2015년8월부터 KVN 및 KVN과 일본 VERA로 구성되는 한일공동 VLBI 관측망(KaVA)을 이용해서 전파 은하 3C 84(z = 0.0176, 1 mas = 0.36 pc)의 밀리미터파장 모니터링을 진행하고 있다. KVN과 KaVA를 이용하면 1 pc 이하의 스케일로 3C 84의 중심구조를 고감도에서 분해할 수 있다. 이번 발표에서는 KVN 및 KaVA로 거의 동시에 실시한 관측결과를 중심으로 보고한다. 관측은 2016년2월22일(KaVA 43 GHz) 및 23일(KVN 86 GHz)에 실시되었다. 양 주파수의 이미지에서 종래의 센치미터 ~ 밀리미터파장 VLBI관측으로도 검출되어 있는 중심핵(C1) 및 남쪽에 약 3 mas 떨어져서 위치하는 로브(C3) 성분 뿐만 아니라 C1으로부터 북쪽에 약 2.5 mas 떨어져서 위치하는 새로운 성분(N1)을 검출하였다. N1의 검출 수준은 43, 86 GHz 모두 $6{\sigma}$이며, 양 주파수 사이에서 광학적으로 두꺼운 스펙트럼을 가지고 있다. 과거의 관측으로 측정된 C3의 겉보기 속도는 빛의 속도의 약 23%이며, 남북 로브의 구조와 운동의 대칭을 가정하면 N1이 도플러 분사출 효과 때문에 어두워지고 있는 가능성은 낮다. 따라서 C3에 대응하는 북쪽 N1로브로부터의 복사가 블랙홀 주변의 플라스마 디스크로 인해 저주파수에서 강한 흡수를 받고 있는 결과고 생각된다.

  • PDF

Numerical modeling of debris flow in Mt. Umyeon using FLO-2D model (FLO-2D 모형을 이용한 우면산 토석류 수치모델링)

  • Kim, Seung-Eun;Paik, Joong-Cheol;Kim, Kyung-Suk
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2012.05a
    • /
    • pp.105-105
    • /
    • 2012
  • 최근 우리나라는 집중호우로 인한 토석류의 발생이 현저하게 증가하고 있으며, 2002년 태풍 루사와 2003년 매미 그리고 2006년 7월 집중호우 등으로 인한 피해의 규모는 여러 조사와 문헌에서도 확인할 수 있다. 2011년 7월, 서울 우면산 일대에서는 집중호우로 인한 토석류가 발생하였으며, 16명의 인명손실을 포함한 큰 피해가 있었다. 우면산 토석류는 십여 개 지역에서 동시다발적으로 발생하였으며, 토석류 발생 유역 특성과 토석류의 유동특성을 분석하기 위한 현장 조사가 진행되었다. 조사한 자료에 따르면 우면산 일대의 일일 강우량은 서초 기상측정소를 기준으로 최대 24시간 누적 324mm 그리고 시간당 최대 68.5mm/hr를 기록하였다. 상업용 소프트웨어인 FLO-2D는 유사농도의 함수로서 점성(viscous)응력, 항복(yield)응력, 난류 및 분산(dispersive) 응력항을 포함하는 2차 유변학(quadratic rheology) 모델을 기본으로 사용하여 이류(mudflow)와 토석류(debris flow)를 모의할 수 있다. FLO-2D는 흐름의 운동량 및 에너지 보존을 고려하여 격자와 시간에 관계없이 유동심도, 속도, 압력을 예측할 수 있으며, 격자 기반의 모델로서 GIS 및 기타 응용 프로그램들과 연동이 쉽다는 장점이 있다. 그러나 하상침식에 의해 유발된 토석류의 체적 증가는 고려 할 수 없으므로 토석류의 전파 및 퇴적영역에서의 토석류 모의에만 사용할 수 있는 단점이 있다. 이 연구의 목적은 FLO-2D 소프트웨어를 이용하여 우면산에서의 토석류 현상을 재현하는 것이다. 우면산 일대에서 발생한 토석류 중 서초구 방배동의 래미안 아파트 부근에서 발생한 토석류에 대하여 수치지도(DEM)와 현장조사를 통해 얻은 지형자료, 해당 지역의 강우량 및 지질 특성 자료 등을 토대로 FLO-2D 모델을 적용하여 토석류의 흐름특성을 검토한다. 토석류 유동 및 퇴적에 대한 가용한 현장관측 자료와의 비교 분석을 통하여 토석류 특성 값을 산정하고, 모델의 적용성을 검증한다.

  • PDF

A Study on Friction Loss of Engine using Microfluidics Approach (미세유동의 경계면 특성을 적용한 엔진 마찰 손실 연구)

  • Park, Cho Hee;Kim, Bo Hung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.12
    • /
    • pp.1035-1042
    • /
    • 2014
  • Reducing the friction of engine parts is an important issue in engine design. The loss of energy in the piston assembly due to mechanical friction ranges from 40 to 55%, and there is an increase in the total energy of about 5% if the friction of the piston can be removed. In order to reduce the friction loss at the level of each engine part, it is necessary to perform a comparative analysis with other engines to determine the important factors affecting the energy loss. Several studies have been performed to analyze the lubrication based on hydrodynamic modeling, since a piston lubrication system has dimensions in the nanoscale to microscale domain. Therefore, it is necessary to determine the correlations between the molecular and continuum systems. In this study, we investigated the friction changes due to the various interactions between molecules in the wall/fluid interface, where a microscopic movement of the oil film occurs along the cylinder liner of the engine.

Curriculum Relevance Analysis of Physics Book Report Text Using Topic Modeling (토픽모델링을 활용한 물리학 독서감상문 텍스트의 교육과정 연계성 분석)

  • Lim, Jeong-Hoon
    • Journal of Korean Library and Information Science Society
    • /
    • v.53 no.2
    • /
    • pp.333-353
    • /
    • 2022
  • This study analyzed the relevance of the curriculum by applying topic modeling to book reports written as content area reading activities in the 'physics' class. In order to carry out the research, 332 physics book reports were collected to analyze the relevance among keywords and topics were extracted using STM. The result of the analysis showed that the main keywords of the physics book reports were 'thought', 'content', 'explain', 'theory', 'person', 'understanding'. To examine the influence and connection relationship of the derived keywords, the study presented degree centrality, between centrality, and eigenvetor centrality. As a result of the topic modeling analysis, eleven topics related to the physics curriculum were extracted, and the curriculum linkage could be drawn in three subjects (Physics I, Physics II, Science History), and six areas (force and motion, modern physics, wave, heat and energy, Western science history, and What is science). The analyzed results can be used as evidence for a more systematic implementation of content area reading activities which reflect the subject characteristics in the future.

Analysis and Improvement of System Efficiency for the Moving-actuator type Bi-Ventricular Assist Device ($AnyHeart^{TM}$) (한국형 양심실 보조 인공 심장의 효율 분석 및 개선에 관한 연구)

  • Chung, J.H.;Nam, K.W.;Choi, S.W.;Lee, J.J.;Park, C.Y.;Kim, W.E.;Choi, J.S.;Min, B.G.
    • Journal of Biomedical Engineering Research
    • /
    • v.22 no.5
    • /
    • pp.449-458
    • /
    • 2001
  • This is a test report of system efficiency for the moving-actuator type Bi-ventricular assist device (AnyHear $t^{MT}$ ) Seoul National University). $AnyHeart^{TM}$), as an energy converter. utilities a brushless DC motor(S/M 566-26A. Sierracin/ Magnedyne, Carlsbad, CA. U.S.A.) generating their pendulous motion in the epicyclic gear train. It is necessary to know about the overall efficiency of the system. The system is subdivided into three parts: motor part, actuator part and blood sac part (including valves, etc.) according to system mechanism. The motor was operated with a variable range of torque. angular speed and width of voltage Pulse In this report. $AnyHeart^{TM}$ is focused on the efficiency of the motor and actuator parts. 4 $\ell/min$ pump output. which is normal condition of $AnyHeart^{TM}$ system, the total system efficiency is 8%, which is composed of 50%, 85% and 17% efficiency (motor Part, actuator Part and blood sac Part) respectively. In the analyzed result. applied input voltage on normal condition of $AnyHeart^{TM}$ is determined. Also speed Profile with considering filling state of blood sac is Provided. In the test of the in vitro mock circulation. some experimental results are Provided to demonstrate the effectiveness of the Presented approach.

  • PDF

A Numerical Analysis of Flow Characteristics in a Heat Recovery Steam Generator with the Change of Inlet Flow Conditions (배열회수보일러(HRSG)의 입구유동 경계조건에 따른 유동특성 변화에 관한 연구)

  • Kim, Tae-Kwon;Lee, Boo-Yoon;Ha, Ji-Soo
    • Journal of the Korean Institute of Gas
    • /
    • v.15 no.3
    • /
    • pp.53-57
    • /
    • 2011
  • The present study has been carried out to analyze the flow characteristics of a heat recovery steam generator with the change of inlet flow conditions by using numerical flow analysis. The inlet of HRSG corresponds the outlet of gas turbine exit and the flow after gas turbine has strong swirl flow and turbulence. The inlet flow condition of HRSG should be included the exit flow characteristics of gas turbine. The present numerical analysis adopted the flow analysis result of gas turbine exit flow as a inlet flow condition of HRSG analysis. The computational flow analysis result of gas turbine exit shows that the maximum axial velocity appears near circular duct wall and the maximum turbulent kinetic energy and dissipation rate exist relatively higher gradient region of axial velocity. The comparison of flow analysis will be executed with change of inlet turbulent flow condition. The first case is using the inlet turbulent properties from the result of computational analysis of gas turbine exit flow, and the second case is using the assumed turbulent intensity with the magnitude proportional to the velocity magnitude and length scale. The computational results of flow characteristics for two cases show great difference especially in the velocity field and turbulent properties. The main conclusion of the present study is that the flow inlet condition of HRSG should be included the turbulent properties for the accurate computational result of flow analysis.

2-Dimensional Unsteady Modeling of Spray Flame Formed in a Laminar Counterflow Field - Effects of Equivalence Ratio and Fuel - (층류 대향류장에 형성된 분무화염의 2차원 비정상 모델링 -당량비 및 연료종에 관한 영향-)

  • Hwang, Seung-Min;Chung, Jin-Do;Seo, Byung-Min;Kim, Young-Woo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.10
    • /
    • pp.933-940
    • /
    • 2009
  • To evaluate characteristics in spray flame, laminar counterflow is investigated on the effects of equivalence ratio and fuel by a two-dimensional DNS (direct numerical simulation). For the gaseous phase, Eulerian mass, momentum, energy, and species conservation equations are solved. For the disperse phase, all individual droplets are calculated by the Lagrangian method without the parcel model. n-Decane ($C_{10}H_{22}$) and n-heptane ($C_7H_{16}$) is used as a liquid spray fuel, and a one-step global reaction is employed for the combustion reaction model. As equivalence ratio increases, the fuel ignites early and the high temperature region spreads wider. The peak value of temperature, however, tends to once increase and then decreases with increasing equivalence ratio. The decrease in the peak value of temperature for the higher equivalence ratio condition is caused by the cooling effect associated with droplet group combustion. Since the evaporation of n-heptane is early, the high temperature region spreads wider than ndecane, but the peak values of temperature for both n-heptane and n-decane is almost same.