Experimental Study of Co-firing and Emission Characteristics Fueled by Sewage Sludge and Wood Pellet in Bubbling Fluidized Bed (기포 유동층 반응기를 이용한 하수슬러지 및 우드펠렛 혼소에 관한 연소 특성 분석 및 비교)

  • Lee, Youngjae;Kim, Jongmin;Kim, Donghee;Lee, Yongwoon
    • Clean Technology
    • /
    • v.23 no.1
    • /
    • pp.80-89
    • /
    • 2017
  • The bubbling fluidized bed (BFB) reactor with a diameter of 0.1 m and a height of 1.2 m was used for experimental study of co-firing and emission characteristics fueled by sewage sludge (SS) and wood pellet (WP). The facility consists of a fluidized bed reactor, feeding system, cyclone, condenser and gas analyzer, The mean particle diameter and minimum fluidization velocity are $460{\mu}m$ and $0.21ms^{-1}$ respectively. SS produced from Korea and WP from Canada were examined. The various mixing ratios of WP were 20, 50, and 80% based on HHV. The equivalence ratio of 1.65, reactor temperature of $800^{\circ}C$, air flow rate of $100Lmin^{-1}$, and fluidization number of 4 were fixed in the BFB experiment. In TGA, the range of combustion temperature of SS was wider than that of WP. It represents that the combustibility of WP is higher than that of SS. The BFB reactor temperature was maintained between 800 and $900^{\circ}C$. CO emission of SS was high because of lower combustibility. $NO_X$ and $SO_X$ formation of SS were higher than that of WP since high nitrogen and sulfur contents of SS. CO, $NO_X$, and $SO_X$ formation were suppressed as the mixing ratio of WP was increased. The slagging and fouling tendencies show high in all test conditions.

Investigation on Combustion Characteristics of Sewage Sludge using Pilot-scale Bubbling Fluidized Bed Reactor (파일럿 규모 기포 유동층 반응기를 이용한 하수 슬러지 연소 특성 분석)

  • Kim, Donghee;Huh, Kang Y.;Ahn, Hyungjun;Lee, Youngjae
    • Clean Technology
    • /
    • v.23 no.3
    • /
    • pp.331-342
    • /
    • 2017
  • To estimate the combustion characteristics of sewage sludge and wood pellet, thermogravimetric analysis (TGA) was conducted. As TGA results, combustion characteristics of sewage sludge was worse than wood pellet. In ash fusion temperature (AFT) analysis, slagging tendency of sewage sludge is very high compared to wood pellet. And also, the bubbling fluidized bed reactor with a inner diameter 400 mm and a height of 4300 mm was used for experimental study of combustion characteristics fueled by sewage sludge and wood pellet. The facility consists of a fluidized bed reactor, preheater, screw feeder, cyclone, ash capture equipment and gas analyzer. The thermal input of sewage sludge cases were $54.5{\sim}96.5kW_{th}$, in case of wood pellet experiment, it was $96.1kW_{th}$. As experiment results, the $NO_x$ emission of sewage sludge was averagely about 10 times the $NO_x$ emission of wood pellet. And also CO emission of sewage sludge is about 3.5 times of wood pellet. Lastly as a result of analysis of captured ash in cyclone, the combustion efficiency of all cases were over 99%, but the potential for slagging/fouling was high at all cases by component analysis of ash.

Co-firing Characteristics and Slagging Behavior of Sewage Sludge with Coal and Wood Pellet in a Bubbling Fluidized Bed (기포 유동층 반응기를 이용한 하수 슬러지와 석탄 및 우드 펠렛의 혼소 특성 및 슬래깅 성향 연구)

  • Ahn, Hyungjun;Kim, Donghee;Lee, Youngjae
    • Clean Technology
    • /
    • v.24 no.4
    • /
    • pp.323-331
    • /
    • 2018
  • The results of an experimental investigation on the co-firing characteristics and slagging behavior of dried and hydrothermal carbonization sewage sludge, sub-bituminous coal, and wood pellet in a fluidized bed were presented. Combustion tests were conducted in a lab-scale bubbling fluidized bed system at the uniform fuel-air equivalence ratio, air flow rate, and initial bed temperature to measure bed temperature distribution and combustion gas composition. 4 different fuel blending cases were prepared by mixing sewage sludge fuels with coal and wood pellet with the ratio of 50 : 50 by the heating value. $NO_x$ was mostly NO than $NO_2$ and measured in the range of 400 to 600 ppm in all cases. $SO_2$ was considered to be affected mostly by the sulfur content of the sewage sludge fuels. The cases of hydrothermal carbonization sewage sludge mixture showed slightly less $SO_2$ emission but higher fuel-N conversion than the dried sewage sludge mixing cases. The result of fly ash composition analysis implied that the sewage sludge fuels would increase the possibility of slagging/fouling considering the contents of alkali species, such as Na, K, P. Between the two different sewage sludge fuels, dried sewage sludge fuel was expected to have the more severe impact on slagging/fouling behavior than hydrothermal carbonization sewage sludge fuel.

Performance Test and Flue Gas Characteristics of a 350 kW Wood Pellet Boiler (350 kW(300,000 kcal/h)급 우드 펠렛 보일러 운전 특성 및 성능 평가)

  • Kim, Jong-Jin;Kang, Sae-Byul
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.167-171
    • /
    • 2009
  • We conducted performance test of a 350 kW class wood pellet boiler installed at a dormitory whose total area is $1,354\;m^2$. The maximum heating capacity of the boiler is 350 kW(300,000 kcal/kg). The wood pellet boiler consists of 3 parts; boiler, hot water storage tank and wood pellet storage tank. In testing the boiler, we shut off hot water utility supply and open up floor heating water system in order to measure exact value of the heating output of the wood pellet boiler. To determine the efficiency and heating output of the wood pellet boiler, we measured mass flow rate of wood pellet, the lower heating value(LHV) of the wood pellet, mass flow rate and temperature of water for floor heating and so on. We measured the mass flow rate of fuel, wood pellet with respect to rotational speed of auger, wood pellet feeding screw. We also measured the flue gas concentration of the wood pellet boiler by using a gas analyser. The result shows that the efficiency of the wood pellet boiler is 80.6% based on lower heating value at 124 kW of heating output. At this condition, O2 concentration of the flue gas is 6.0%, CO and NOx concentrations are 85 and 102 ppm.

  • PDF

Hight Efficiency Gasification of Biomass and Tar Reduction by Waste Metal (폐금속을 이용한 바이오매스의 고효율 가스화 및 타르 발생량 저감)

  • Sung, Hojin;Horio, Masayuki
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.179.2-179.2
    • /
    • 2011
  • 바이오매스 가스화 프로세스 개발에 있어서 가장 기본적인 해결과제는 고발열량의 합성가스 제조, 냉가스 효율의 향상, 타르 발생량 저감 및 제거이다. 가스화 효율 향상에 대한 연구는 국내외 적으로 많이 이루어지고 있으나, 타르 발생량 저감에 대한 연구는 많이 이루어져 있지 않다. 타르는 분자량이 큰 방향적 탄화수소로 응축되면 점성이 높아 배관폐쇄, 정제설비의 압력손실 증가로 인해 운전정지 및 가스화율 저하의 원인이 된다. 가스화로에서 타르 발생량을 저감시키는 방법 중에는 Ni계 촉매를 이용하는 방법이 있으나, 카본 누적에 의한 활성저하, 알칼리금속에 의한 응집 등의 문제가 발생할 수 있다. 한편 철산화물은 합성가스 중의 C2-C3계의 타르를 분해하는데 효과가 알려져 있다. 따라서 본 연구에서는 적벽돌, 염색슬러지 회재 등에는 철산화물이 다량 함유되어 있는 것에 착안하여 폐기물중의 폐금속을 이용한 바이오매스 가스화에 대한 연구를 수행하였다. 점토광물계 폐기물인 적벽돌 파쇄물($SiO_2$ 67.2%, $Al_2O_3$ 19.7%, $Fe_2O_3$ 8.7%, $K_2O$ 2.0%, $TiO_2$ 1.2%, MgO 0.7%)을 전처리 한 후 유동매체로하여 우드펠렛을 가스화한 결과, 가스 생성량이 증가하고, 타르 및 탄화수소류가 감소하는 경향을 나타내었다. 특히 타르는 후단의 타르 트랩에서 타르가 거의 검출이 되지 않았다. 전처리를 하지 않은 적벽돌 파쇄물은 반응시간이 경과한 후에 가스화율이 증가함에 따라 철화합이 가스화로내에서 환원되어 타르를 분해하는데에는 어느 정도의 반응시간이 필요한 것을 확인하였다.

  • PDF

Electrolytic Reduction of 1 kg-UO2 in Li2O-LiCl Molten Salt using Porous Anode Shroud (Li2O-LiCl 용융염에서의 다공성 양극 슈라우드를 이용한1kg 우라늄산화물의 전해환원)

  • Choi, Eun-Young;Lee, Jeong;Jeon, Min Ku;Lee, Sang-Kwon;Kim, Sung-Wook;Jeon, Sang-Chae;Lee, Ju Ho;Hur, Jin-Mok
    • Journal of the Korean Electrochemical Society
    • /
    • v.18 no.3
    • /
    • pp.121-129
    • /
    • 2015
  • The platinum anode for the electrolytic reduction process is generally surrounded by a nonporous ceramic shroud with an open bottom to offer a path for $O_2$ gas produced on the anode surface and prevent the corrosion of the electrolytic reducer. However, the $O^{2-}$ ions generated from the cathode are transported only in a limited fashion through the open bottom of the anode shroud because the nonporous shroud hinders the transport of the $O^{2-}$ ions to the anode surface, which leads to a decrease in the current density and an increase in the operation time of the process. In the present study, we demonstrate the electrolytic reduction of 1 kg-uranium oxide ($UO_2$) using the porous shroud to investigate its long-term stability. The $UO_2$ with the size of 1~4mm and the density of $10.30{\sim}10.41g/cm^3$ was used for the cathode. The platinum and 5-layer STS mesh were used for the anode and its shroud, respectively. After the termination of the electrolytic reduction run in 1.5 wt.% $Li_2O-LiCl$ molten salt, it was revealed that the U metal was successfully converted from the $UO_2$ and the anode and its shroud were used without any significant damage.

Spontaneous Combustion of Various Fuels of Carbonization Rank (탄화도별 발전연료의 자연발화 특성 평가)

  • Kim, Jae-Kwan;Park, Seok-Un;Jeong, Jae-Hyeok;Shin, Dong-Ik;Hong, Jun-Seok;Hong, Jin Pyo
    • Journal of Energy Engineering
    • /
    • v.26 no.3
    • /
    • pp.78-89
    • /
    • 2017
  • Spontaneous combustion propensity of various coals of carbonization grade as a pulverized fuel of coal fired power plant has been tested from an initial temperature of $25^{\circ}C$ to $600^{\circ}C$ by heated in an oven with air to analyze an self oxidation starting temperature. This tests produce a CPT(Cross Point Temperature), IT(Ignition temperature) and CPS(Cross Point Slope) by calculated as the slope of time taken a rapid exothermic oxidation reaction at CPT base. CPS show a carbonization rank dependence, whereby wood pellet has the highest propensity to spontaneous combustion of $20.995^{\circ}C/min$. A subbituminous KIDECO coal shows an CPS values of $15.370^{\circ}C/min$ whereas it of pet coke of the highest carbonization rank has $20.950^{\circ}C/min$. The nature of this trend is most likely a concentration of volatile matter and oxygen functional groups of coal surface that governs the available component for oxidation as well as surface area of fuel char, and constant pressure molar heat.