• 제목/요약/키워드: 용접식 판형열교환기

검색결과 6건 처리시간 0.022초

동일 전열면적을 갖는 용접식 판형열교환기와 관류형 열교환기의 성능 비교 (Performance Comparison of a Welded Plate Heat Exchanger and Shell and Tube Heat Exchanger with Same Heat Transfer Area)

  • 함정균;김민준;안성국;조홍현
    • 한국지열·수열에너지학회논문집
    • /
    • 제15권4호
    • /
    • pp.46-54
    • /
    • 2019
  • In this study, the performance of a shell and tube heat exchanger (STHE) and welded plate heat exchanger (WPHE) was measured experimentally. The pass numbers of the STHE was changed by 1, 2 and 4. As a result, the WPHE showed 2.1 times higher heat exchange capacity than that of the STHE. In case of pressure drop, the STHE with 1 and 2 pass number has a lower pressure drop than the WPHE, while the STHE with 4 pass presented higher pressure drop than the WPHE. The performance index considering the heat exchange capacity and pump consumption power, showed in oder of STHEPass1 > STHEPass2 > W PHE > STHEPass4 under the same flow rate. Therefore, when the WPHE was designed optimally under same operating condition with STHE, the maintenance fee and space can be reduced effectively by using the WPHE.

용접식 판형열교환기 헤더형상에 따른 채널 위치별 유량 분배 특성 고찰 (Investigation of Flow Distribution Characteristics at the Channel Location according to the Header Shape of Welded Plate Heat Exchanger)

  • 함정균;김의;안성국;조홍현
    • 한국지열·수열에너지학회논문집
    • /
    • 제15권3호
    • /
    • pp.7-13
    • /
    • 2019
  • To improve the flow distribution at channel locations in the welded plate heat exchanger with "L"-type inflow, the flow visualization of Model 1 was carried out. Besides, the characteristics of flow distribution was investigated experimentally according to the header shape. The inlet flow rate for each channel location was increased at the side channels but decreased at the central channels. In the case of Model 2, which has a slant structure added to the basic header of Model 1, the unevenness of inlet flow increased by 23% from 0.019 to 0.023 as compared to Model 1. On the other hand, Model 3, which has a baffle structure added to Model 2, showed 0.064 unevenness in inlet flow, which was a 36% reduction one compared to Model 1. To improve the distribution at each channel in the welded plate heat exchanger with "L"-type flow, it is necessary to improve the header external shape for the guide of flow as well as the baffle structure for reduction of vortex flow.

용접형 판형 열교환기의 열전달 및 압력강하 특성에 관한 실험적 연구 (Experimental study of Heat Transfer and Pressure Drop Characteristics for the Welded Plate Heat Exchanger)

  • 정종윤;김성수;강용태
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.419-424
    • /
    • 2008
  • Heat transfer and pressure drop characteristics of welded plate heat exchanger are studied to apply it for the solution heat exchanger of 210RT absorption system. This study quantifies the effect of mass flow rate and strong solution concentration on the heat transfer coefficient and pressure drop in the plate heat exchanger. The concentration of weak solution is fixed at 55% and the strong solution varies 55%, 57%, and 59% in mass. The results show that the overall heat transfer coefficient and pressure drop increase linearly with increasing Reynolds number. It is also found that the heat transfer coefficient of hot side increases with increasing the concentration of strong solution while the strong solution concentration has no effect on heat transfer coefficient of cold side.

  • PDF

용접식 판형 열교환기의 성능에 관한 실험적 연구 (Experimental study on the performance of a brazed plate heat exchanger)

  • 김종하;윤재호;권오경;김종훈;류해성;이창식
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집D
    • /
    • pp.477-482
    • /
    • 2001
  • An experimental study on the performance evaluation of a brazed plate heat-exchanger with 10RT of normal cooling capacity has been carried out. In the present study, a brazed type plate heat exchanger was tested at a chevron angle $25^{\circ}$ with refrigerant R-22. Mass flux was ranged from $23\;to\;58kg/m^{2}s$ in condensation, and from $22\;to\;53kg/m^{2}s$ in evaporation. The heat transfer coefficient and pressure drop increased with the mass flux increases. The water side pressure drop increased with the cooling water flow rate and chilled water flow rate increases, while mass flux has little affect. It is also shown that the system performance can be improved by enlarging condensation heat transfer area.

  • PDF

용접식 판형열교환기에서 작동유체의 유량과 온도변화에 따른 성능특성 고찰 (Investigation of Performance Characteristics in a Welded Plate Heat Exchanger according to Mass flow rate and Temperature)

  • 함정균;김민준;안성국;조홍현
    • 한국지열·수열에너지학회논문집
    • /
    • 제14권4호
    • /
    • pp.20-26
    • /
    • 2018
  • In this study, the performance characteristics of a welded plate heat exchanger was investigated experimentally. Performance tests were carried out according to the flow rate and inlet temperature of working fluid. As a result, the heat transfer capacity increased by 335.5 kW with an increasing the flow rate and temperature difference between hot and cold side. However, the overall heat transfer coefficient was increased with the increase of flow rate, and it was not effected significantly from inlet temperature difference between hot and cold working fluid. The pressure drop was increased by 55.78 kPa with an increasing the frow rate when the flow rate ratio between hot and cold side 1:1. However, the tendency of pressure drop was difference when flow rate ratio wasn't 1:1. In case that the flow rate ratio between hot and cold side was not 1:1, the pressure drop at the low flow rate side was higher than that when the flow rate ratio was 1:1, while pressure drop of the other side was decreased compared to that when the flow rate ratio was 1:1.

용접식 판형 열교환기의 성능에 관한 실험적 연구 (An Experimental Study on the Performance of a Brazed Plate Heat Exchanger)

  • 김종하;권오경;윤재호;이창식
    • 설비공학논문집
    • /
    • 제14권1호
    • /
    • pp.83-90
    • /
    • 2002
  • An experimental study on the performance evaluation of a brazed plate heat exchanger with 10USRT of normal cooling capacity has been carried out. In the present study, a brazed plate heat exchanger was tested at a chevron angle $25^{\circ}$with refrigerant R-22. Refrigerant mass flux was ranged from 23 to 58 kg/$m^2$s in condensation, and from 22 to 53 kg/$m^2$s in evaporation. The heat transfer coefficients and pressure drops are increased as the mass flux increases. The water side pressure drop is increased as the cooling water flow rate and chilled water flow rate increase, while mass flux has little effect. It is also shown that the system performance can be improved by enlarging condensation heat transfer area.