• Title/Summary/Keyword: 용접보

Search Result 294, Processing Time 0.022 seconds

Comparative Study for Long Span Beams built up with Sub-marine High Strength Structural Steels at High Temperature using Analytical Method (고강도 용접구조용 강재 적용 장스팬 보부재의 해석적 내화성능 비교 연구)

  • Kwon, In-Kyu
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2016.05a
    • /
    • pp.120-121
    • /
    • 2016
  • Recently, the building has been changed into high-rise and long span and this yields a development of high performance structural steels in construction market. According to this effect, the SM 520 and the SM 570 were developed and utilized into steel building industry. However, the study for fire resistance of them were not done actively. In this study, to know and comparative the fire resistance performance of long span beams built up with high strength structural steels an analytical method is going to applied using mechanical and thermal properties at high temperature.

  • PDF

PWSCC of Alloy 600 components in PWRs-Part 1 (원자력 발전소 Alloy 600 부품의 PWSCC-Part 1)

  • Hwang, Seong Sik
    • CORROSION AND PROTECTION
    • /
    • v.12 no.1
    • /
    • pp.1-11
    • /
    • 2013
  • Alloy 600 재료의 PWSCC의 개념을 소개하고 그 발생과 전파에 미치는 미세조직, 온도, 응력, 수화학 환경등의 주요인자를 정리하였다. ◯ PWSCC란 니켈 기지 합금인 Alloy 600와 그 용접재인 Alloy 82/182 재료가 원자로 1차수 환경에서 보이는 응력부식균열을 의미한다. ◯ Alloy 600의 PWSCC에 미치는 주요 인자에는 재료의 미세조직, 응력, 온도, 환경등이 있으며 그 중에서 재료의 미세조직이 가장 지배적인 인자이다. ◯ 재료내의 탄화물은 탄소 함량과 열처리 조건에 따라 달리 형성되며 입계를 따라 준연속적으로 잘 발달된 입계탄화물을 가지는 재료가 PWSCC에 저항성을 가진다. ◯ 손상속도는 부가 응력의 네 제곱에 비례하여 증가하는 것으로 알려져 있다. ◯ PWSCC는 Arrhenius 관계의 열활성화 과정(thermally activated process)이다. ◯ 용존수소량에 따라 재료의 부식전위가 정해지는데 전극전위가 Ni/NiO 평형전위 부근에서 가장 큰 균열 성장 민감도를 보인다는 데는 연구자들 사이에 이견이 없다. 그러나 균열의 개시에 대한 용존수소량의 영향에 대해서는 이견이 있다.

Characteristic of Local Behavior in Orthotropic Steel Deck Bridge with Open Ribs according to Running Vehicle (주행차량에 따른 개단면 강바닥판 교량의 국부거동 특성)

  • Lee, Sung-Jin;Kyung, Kab-Soo;Park, Jin-Eun;Lee, Hee-Hyun
    • Journal of Korean Society of Steel Construction
    • /
    • v.24 no.1
    • /
    • pp.101-108
    • /
    • 2012
  • The orthotropic steel deck bridge made by using relatively thin steel plate, and structural members such as transverse and longitudinal ribs, cross beam, etc. in the bridge are fabricated with complex shape by welding. Therefore, the possibility occurring deformation and defects by welding is very high, and stress states in the welded connection parts are very complex. Also, the fatigue cracks in orthotropic steel deck bridge are happening fromthe welded connection parts of secondary member than main member. However, stress evaluation for main members is mainly carried out in the design process of the bridge, detailed stress evaluation and characteristic analysis is not almost reviewed in the structural details which fatigue crack occurred. For the orthotropic steel deck bridge with open ribs which has been serviced for 29 years, in this study, the cause of fatigue crack is investigated and the fatigue safety of the bridge is examined based on fieldmeasurement by the loading test and real traffic condition. Also, structural analyses using gridmodel and detailed analysis model were carried out for the welded connection parts of longitudinal rib and diaphramthat fatigue crack occurred. Additionally, the behavior characteristics due to running vehicles were investigated by using influence area analysis for these structural details, and the occurrence causes of fatigue crack in the target bridge were clarified.

Study on Hydrogen Embrittlement for API 5L X65 Steel Using Small Punch Test II : Weld Metal (소형펀치 시험을 이용한 API 5L X65 강의 수소취화에 관한 연구 II : 용접부)

  • Jang, Sang-Yup;Yoon, Kee-Bong
    • Journal of Energy Engineering
    • /
    • v.18 no.1
    • /
    • pp.56-62
    • /
    • 2009
  • With weld metal of X65 steel, hydrogen was charged by electro-chemical method and mechanical behavior such as strength was measured by the small punch test. The weld metal was more sensitive to hydrogen charging than the case of base metal. The small punch (SP) strength was decreased as the hydrogen contents increased. Magnitude of strength decrease was dependent on current density, temperature, charging time. Current density and charging time have significant effect on the mechanical properties but temperature of electrolyte has limited effect. Fractured surfaces of the tested specimens were observed by SEM (scanning electron microscope). In the hydrogen charged specimens cleavage fracture were observed, which is consistent with the SP test results. Since the testing procedure for studying hydrogen embrittlement proposed in this study has shown good reproducibility of test results, the proposed method can be assumed to be a reliable test procedure. Using the electrochemical charging and the small punch test, the change of SP strength for X65 weld metal due to hydrogen embritlement could be evaluated sensitively.

Cyclic Seismic Testing of Cruciform Concrete-Filled U-Shape Steel Beam-to-H Column Composite Connections (콘크리트채움 U형합성보-H형강기둥 십자형 합성접합부의 내진성능)

  • Park, Chang-Hee;Lee, Cheol-Ho;Park, Hong-Gun;Hwang, Hyeon-Jong;Lee, Chang-Nam;Kim, Hyoung-Seop;Kim, Sung-Bae
    • Journal of Korean Society of Steel Construction
    • /
    • v.23 no.4
    • /
    • pp.503-514
    • /
    • 2011
  • In this research, the seismic connection details for two concrete-filled U-shape steel beam-to-H columns were proposed and cyclically tested under a full-scale cruciform configuration. The key connecting components included the U-shape steel section (450 and 550 mm deep for specimens A and B, respectively), a concrete floor slab with a ribbed deck (165 mm deep for both specimens), welded couplers and rebars for negative moment transfer, and shear studs for full composite action and strengthening plates. Considering the unique constructional nature of the proposed connection, the critical limit states, such as the weld fracture, anchorage failure of the welded coupler, local buckling, concrete crushing, and rebar buckling, were carefully addressed in the specimen design. The test results showed that the connection details and design methods proposed in this study can well control the critical limit states mentioned above. Especially, the proposed connection according to the strengthening strategy successfully pushed the plastic hinge to the tip of the strengthened zone, as intended in the design, and was very effective in protecting the more vulnerable beam-to-column welded joint. The maximum story drift capacities of 6.0 and 6.8% radians were achieved in specimens A and B, respectively, thus far exceeding the minimumlimit of 4% radians required of special moment frames. Low-cycle fatigue fracture across the beam bottom flange at a 6% drift level was the final failure mode of specimen A. Specimen B failed through the fracture of the top splice plate of the bolted splice at a very high drift ratio of 8.0% radian.

Experimental Study on Double Skin Composite Walls Subjected to Cyclic Loading (주기하중을 받는 이중강판합성벽의 실험연구)

  • Eom, Tae Sung;Park, Hong Gun;Kim, Jin Ho;Chang, In Hwa
    • Journal of Korean Society of Steel Construction
    • /
    • v.20 no.2
    • /
    • pp.289-301
    • /
    • 2008
  • Double skin composite (DSC) wall is a structural wall that is filed with concrete between two steel plate skins connected by tie bars. This type of wall was developed to enhance the structural performance of wall, to reduce wall thickness, and to enhance constructibility, eliminating the use of formwork and re-bars. In this study, cyclic tests were performed to investigate the inelastic behavior and earthquake resistance of isolated and coupled DSC walls with rectangular and T-shapedcross-sections. The DSC walls showed stable cyclic behaviors, exhibiting excellent energy dissipation capacity. The te st specimens failed by the tensile fracture of welded joints at the wall base and coupling beam and by the severe local buckling of the steel plate. The deformation capacity of the walls varied with the connection details at the wall base and their cross-sectional shapes. The specimens with well-detailed connections at the wall base showed relatively god deformation capacity ranging from 2.0% to 3.7% drift ratio. The load-carrying capacities of the isolated and coupled wall specimens were evaluated considering their inelastic behavior. The results were compared with the test results.

Deformation Capacity of Inverted V-Type Brace Strengthened by Built-up Non-welded Buckling Restraint Element (조립형 무용접 좌굴방지재로 보강된 역V형 가새의 변형성능)

  • Kim, Sun Hee;Moon, Ji Young;Choi, Sung Mo
    • Journal of Korean Society of Steel Construction
    • /
    • v.27 no.3
    • /
    • pp.261-271
    • /
    • 2015
  • Steel concentrically braced frame is an efficient system that can acquire resistance against the lateral force of buildings with the least amount of quantity. In this study is intended to proceed on the research of schemes for reinforcement by supplementing previously installed H-formed brace with non-welded cold-formed plastic stiffening materials restricting the flexure and buckling and acquire a consistent strength on the tensile and compressive force. As for the measures of supplementing previously-installed inverted V-formed braced frame, stiffening materials in the previous studies were converted to weak-axial supplementing materials to suggest a specific scheme evaluating the structural function through an experiment of members, interpretation of members, and frame-focused experiment. Reinforced brace satisfied the requirement to be prevent AISC brace from being ruptured due to imbalanced strength in the beam.

Experimental Study on the Behavior of Hybrid Beam-Column Joints Consisted of Reinforced Concrete Column and Steel Beam (철근콘크리트 기둥 및 철골보로 구성된 복합구조의 접합분 거동에 관한 실험적 연구)

  • Choi, Keun-Do;You, Young-Chan;Lee, Li-Hyung
    • Journal of the Korea Concrete Institute
    • /
    • v.15 no.2
    • /
    • pp.297-304
    • /
    • 2003
  • This paper presents the test results of RCS(Reinforced Concrete Steel) beam-column joint with various types of transverse reinforcements such as small-column-type transverse reinforcements, four-piece ㄱ-shape assembled hoops and four-piece ㄱ-shape welded hoops. Five interior beam-column joint specimens were tested to examine the seismic performance and the shear strengths. From the test results, it was found that all the specimens sustained their strength at large levels of story drift(${\theta}$=0.035) without significant loss of strength and stiffness. Therefore it was concluded that the seismic performance and shear strength of the proposed RCS joint are at least the same as those of the specimen with conventional reinforcing details. Also, the contribution of the outer panel to the shear strength of the joint should be evaluated by the compression strut mechanism rather than compression field mechanism.

Reliability assessment of RPCB and FPCB Joints bonded using Thermo-compression (열 압착으로 접합된 RPCB와 FPCB 접합부의 신뢰성 평가)

  • Jang, Jin-Kyu;Lee, Jong-Gun;Lee, Jong-Bum;Ha, Sang-Su;Jung, Seung-Boo
    • Proceedings of the KWS Conference
    • /
    • 2009.11a
    • /
    • pp.81-81
    • /
    • 2009
  • 최근 휴대폰, 노트북 등과 같은 소형 멀티미디어 기기의 사용이 증가함에 따라 전자 패키징 산업은 경박단소화를 요구하고 있습니다. 더불어 전기적 신호의 손실을 줄이기 위해 전기, 전자산업체에서는 가볍고 굴곡성이 우수한 연성인쇄회로기판(Flexible Printed Circuit Board, FPCB)과 가격이 싸고 신뢰성이 입증된 경성인쇄회로기판(Rigid Printed Circuit Board, RPCB)의 전극간 접합에 많은 관심을 보이고 있습니다. 기존에 연성인쇄회로기판과 경성인쇄회로기판을 접합하는 방식으로는 connector를 이용한 체결법이 사용되고 있지만 완성품의 부피가 커지고 자동화 공정이 힘들며 I/O 개수가 제한적이어서 신호전달에 취약한 단점이 있습니다. 또한, 최근 FPCB를 RPCB에 접합하는데 interconnection으로 이방성 도전 필름(Anisotropic conductive film, ACF) 또는 비전도성 필름(Non-conductive film)이 널리 사용되고 있습니다. 하지만 필름의 가격이 비싸고, 낮은 전기 전도도를 보이며, 신뢰성 특성이 낮다는 단점을 가지고 있습니다. 본 실험에서는 기존의 connector 방식과 접착 필름을 이용한 방식을 대체하기 위하여 솔더를 interlayer로 이용하여 열과 압력으로 접합하는 방법에 대하여 연구하였습니다. 실험에 사용된 솔더의 조성은 Sn-3.0Ag-0.5Cu (in wt%)이고, RPCB와 FPCB의 표면처리는 ENIG로 하였습니다. 접합 온도와 접합 시간에 따라 최적의 접합 조건을 도출하고자 하였고, 접합된 시편을 가지고 신뢰성 테스트를 진행하였습니다. $85^{\circ}C$/85% 고온고습 시험과 고온 방치 시험을 통하여 접합부의 신뢰성을 테스트 하였고, 90도 Peel test로 기계적 접합 강도를 측정하였고, 파괴 단면을 Scanning Electron Microscopy (SEM), Energy-dispersive spectroscopy (EDS), X-ray photoelectron spectroscopy (XPS)로 분석하였습니다.

  • PDF

Flexural Behaviour of Encased Composite Beam with Precast Hollow Core Slabs and Channels (속빈 PC 슬래브와 채널을 사용한 매입형 합성보의 휨 거동)

  • Heo, Byung Wook;Kwak, Myong Keun;Bae, Kyu Woong
    • Journal of Korean Society of Steel Construction
    • /
    • v.20 no.4
    • /
    • pp.493-504
    • /
    • 2008
  • This paper deals with the experimental analysis of the flexural behaviour of encased composite beams with hollow core slabs and channels. The shear force between steel beams and hollow core slabs are transferred by channels. Three full-scale specimens were constructed and tested with different steel beam heights, which were compared with those of previous studies. Based on observation of the experiments, the encased composite beams exhibited full shear connection behaviour without any other shear connectors due to their inherent mechanical and chemical bond stress. Experimental results show a behaviour similar to steel-concrete composite beams with classical connectors: elastic and yield domains, great ductility, flexural failure mode (plastic hinge), low relative movement at steel-concrete interface and all specimens failed in a very ductile manner. Consequently, this study enables the validation of the proposed connection device under static loading and shows that it meets modern structural requirements.