• 제목/요약/키워드: 용액형

검색결과 860건 처리시간 0.03초

pH Measurement Using Isosbestic Point of Indicator (지시약의 등흡광점을 이용한 용액의 pH 측정)

  • Won-Hyung Choi;Ho-Jang Hur
    • Journal of the Korean Chemical Society
    • /
    • 제33권2호
    • /
    • pp.203-207
    • /
    • 1989
  • The methyl red stock solution was added to sample solution and the absorbance values of this solution were measured at the maximum absorption wavelengths of the acidic form, the basic form, and the isosbestic point of the indicator. From the measurements of absorbance, the pH of this solution was calculated. The range of absorbance at the isosbestic point was maintained within 0.1 ${\sim}$ 0.3. The error of pH measurement was within ${\pm}0.08$ pH unit in the pH range of sample solution of $pK_I{\pm}1$.

  • PDF

Flow of Dilute Polymer Solutions in the Confined geometry (한정된 공간에서의 희석 고분자 용액의 흐름)

  • 박오옥
    • The Korean Journal of Rheology
    • /
    • 제4권1호
    • /
    • pp.62-69
    • /
    • 1992
  • 한정된 공간 속을 희석 고분자 용액이 흐를 때 그공간의 특성 길이가 고분자의 그 것과 비슷한 경우에는 실험적으로 무한 공간에비하여 점도가 작게 됨을 보였다, 잔탄 검 용 액과 폴리아크릴 아미드 용액이 원통형 다공을 가진 고분자 막을 통해 흐를때의 점도를 뉴 톤 영역뿐 아니라 비뉴톤 영역에서도 한꺼번에 측정할 수 있는 흐름장치를 만들어 실험하였 다, 뉴톤 점도는 다공의 크기가 줄어들수록 줄어드는 경향을 보였는데 이는 두 특성 길이의 비로서 설명할수 있었다, 비뉴톤 점도 영역에서의 지표(power law index)는 폴리아크릴 아 미드 용액에서는 차이가 발견되지 않았으나 잔탄 검용액에서는 다공의 크기가 감소할수록 점점 작은 값을 보였다, 이것은 두 고분자 사슬의 경직성 차이에 기인된다 하겠다. 결론적으 로 벽 근처에 분차 크기 정도의 고분자 희박 영역이 존재하고 그 영역내에서는 고분자 사슬 의 배향 구조가 제한적이다고 하는 이론적 설명과 부합되는 결과를 얻었다.

  • PDF

Preparation of Electrolyte Film for Solid Oxide Fuel Cells by Electrophoretic Deposition (전착법에 의한 음극지지형 SOFC 전해질막 제조)

  • 김상우;이병호;손용배;송휴섭
    • Journal of the Microelectronics and Packaging Society
    • /
    • 제6권1호
    • /
    • pp.23-29
    • /
    • 1999
  • An yttria-stabilized zirconia(YSZ) thin film on a porous NiO-YSZ substrate for an anode support type solid oxide fuel cell(SOFC) was prepared by an electrophoretic deposition(EPD). Deposition condition and film properties in order to obtain the homogeneous YSZ thin film from the EPD solution with different polarity were studied. In different case of alcohol solution, hydrogen gas was produced in aqueous solution from the electrolyte reaction under constant current above 0.138 mA /$\textrm{cm}^2$.Its reaction generated the bubble-formed defect in the deposited film and decreased weight of the film. The homogeneous YSZ thin film was formed in alcohol solution at a constant current, 0.035 mA /$\textrm{cm}^2$ for 10 s.

  • PDF

Preparation of UV-Curable Hydrophilic Coating Films Using Colloidal Silica (콜로이드 실리카를 이용한 UV 경화형 친수성 코팅 도막 제조)

  • Yang, Jun Ho;Song, Ki Chang
    • Korean Chemical Engineering Research
    • /
    • 제55권6호
    • /
    • pp.754-761
    • /
    • 2017
  • UV-curable hydrophilic coating solutions were prepared by mixing colloidal silica dispersed in alcohol with an acrylic monomer, pentaerythritol triacrylate (PETA). Hydrophilic coating films were also prepared by spin coating the hydrophilic coating solutions on PC substrates and UV curing for 10 minutes subsequently. The effect of the amount of colloidal silica in the coating solutions, which was varied from 10 g to 50 g, was investigated on the hydrophilic properties of UV-cured coating films. The results showed that the amount of colloidal silica had a great influence on the hydrophilic properties of UV-cured coating films and the coating film prepared with 30 g of colloidal silica showed a lowest contact angle of $37^{\circ}$ and an excellent pencil hardness of H.

Studies on the Intercalation between Montmorillonite and Lanthanides (몬모리노나이트와 란탄족 원소들과의 인터카레이숀에 관한 연구)

  • Young Gu Ha
    • Journal of the Korean Chemical Society
    • /
    • 제30권5호
    • /
    • pp.488-492
    • /
    • 1986
  • The $Ca^{++}$ and $Mg^{++}$ released during Ca, Mg-Na exchange on Kampo 78 montmorillonite which was treated with various concentrations of NaCl solution, were measured with EDTA titration metbod in the leaching solutions. Lanthanide montmorillonite was prepared with various neutral lanthanide ions from sodium montmorillonite in which the exchangeable ions are displaced from the exchanger, such as the displacement of $Na^+$ by $Ln^{3+}$ ions, Cation exchange capacity (CEC) is determined on remaining lanthanides in the leaching solutions with E. D. T. A titration method. As a results of this study, there were no difference of C. E. C in series of lanthanide contraction, but C. E. C depends on charge density of montmorillonite. When we conformed the structure of Ln-montmorillonite by X-ray diffraction. It was found that there was much difference of pattern between Na-montmorillonite and Ln-montmorillonite.

  • PDF

Large-Scale Synthesis of Plate-Type ZnO Crystal with High Photocatalytic Activity (광촉매 활성이 우수한 판상형 ZnO 결정의 대용량 합성)

  • Kim, Da-Jung;Kim, Bo-Mi;Joe, Ara;Shim, Kyu-Dong;Han, Hyo-Won;Noh, Gyung-Hyun;Jang, Eue-Soon
    • Journal of the Korean Chemical Society
    • /
    • 제59권2호
    • /
    • pp.148-155
    • /
    • 2015
  • ZnO nanoplates were prepared by seed-mediated soft-solution process. Photocatalytic property of ZnO nanoplates was superior to that of conventional ZnO nanoparticles owing to the enhanced (0001) plane with large defect sites. In addition, we found that silica coating method could provide to reduce cytotoxicity of ZnO nanoplates. Finally, we have successfully synthesized for the first time large-scale synthesis of plate-type ZnO as few hundreds gram scale for industrial applications through controlling various reagents of growth solution.

A experimental study of water vapor absorption characteristics using four components solution for gas fired absorption chiller (가스냉난방기용 4성분계 흡수용액의 수증기 흡수특성에 관한 실험적 연구)

  • Lee Yong-Won;Oh Young-Sam;Park Dal-Ryung;Baek Young-Soon
    • Journal of the Korean Institute of Gas
    • /
    • 제2권4호
    • /
    • pp.47-52
    • /
    • 1998
  • Water vapor absorption performance of four components solution ($LiBr+LiNO_3+LiC1+H_2O$) which could be substituted for commonly used $LiBr/H_2O$ solution in water cooled abosorption chiller is tested using a vertical tube absorber. Inlet solution concentration, inlet solution temperature, solution flow rate and inlet temperature of cooling water is varied as experimental parameters. The results of the experiment of water vapor absorption performance show that four components solution should have $2\%$ higher concentration for equal absorption capacity of $LiBr/H_2O$. But considering that four components solution have higher solubility than LiBr solution about $3\%$ high oncentration, four components solution ($LiBr+LiNO_3+LiC1+H_2O$) have more absorption capacity than LiBr solution in actual absorption chiller and can be applied to a small or air cooled absorption chiller.

  • PDF

A COMPARATIVE STUDY ON SHEAR BOND STRENGTHS INFLUENCED BY TIME ELAPSED AFTER BRACKET BONDING WITH A LIGHT-CURED GLASS IONOMER CEMENT (광중합형 글래스아이오노머 시멘트의 브라켓 접착후 시간 경과에 따른 전단결합강도의 비교연구)

  • Lee, Ki-Soo;Lim, Ho-Nam;Park, Young Guk;Shin, Kang-Seob
    • The korean journal of orthodontics
    • /
    • 제25권5호
    • /
    • pp.605-611
    • /
    • 1995
  • The purpose of this study was to evaluate effects of time on shear bond strengths of a light-cured glass ionomer cement and chemically cured resin cement to enamel, and to observe the failure patterns of bracket bondings. Shear bond strength of a light-cured glass ionomer cement were compared with that of a resin cement. Metal brackets were bonded on the extracted human bicuspids. Specimens were subjected to a shear load(in an Instron machine) after storage at room temperature for 5 and 15 minutes; after storage in distilled water at $37^{\circ}C$ for 1 or 35 days. The deboned specimens were measured In respect of adhesive remnant index. The data were evaluated and tested by ANOVA, Duncan's multiple range test, and t-test, and those results were as follows. 1. The shear bond strength of light-cured glass ionomer cement is higher than that of resin cement at 5 and 15 minutes. 2. The shear bond strengths of both light-cured glass ionomer cement and resin cement increase with time. There was no significant difference in those of both 1 day group and 35 day group 3. Light-cured glass ionomer cement is suitable as orthodontic bracket adhesives

  • PDF

A Study on the CO2 Removal Efficiency with Aqueous MEA and Blended Solutions in a Vortex Tube Type Absorber (Vortex Tube 형 흡수장치에서 MEA와 혼합흡수용액을 이용한 CO2 제거 효율 고찰)

  • Ryu, Woo-Jung;Han, Keun-Hee;Choi, Won-Kil;Lee, Jong-Sub;Park, So-Jin
    • Korean Chemical Engineering Research
    • /
    • 제47권6호
    • /
    • pp.795-800
    • /
    • 2009
  • In this study, the $CO_2$ removal characteristics of the Vortex tube type absorbtion apparatus were investigated to enhance the compactness of $CO_2$ absorption process and to reduce the amount of absorbing solution of the $CO_2$ separation process. The Vortex tube with the diameter of 17 mm and the length of 250mm was introduced in the experimental apparatus to treat $20Nm^3/hr$ of $CO_2$ containing flue gas. The flue gases for experiments containing 11~13 vol% of $CO_2$ were supplied from the coal-firing CFBC power plant with 12 ton/hr of steam producing capacity. The mixed solutions of 20 wt% of MEA as base solution with the adding solutions like HMDA, AMP and KOH were used as absorbents. The experiments were executed under the various conditions like the absorbing solution concentrations in the range of 20 to 50 wt%, the flow rate of $CO_2$ containing flue gases in the range of 6 to $15Nm^3/hr$ and the flow rate of absorbing solution in the range of 1.0 to 3.0 l/min. As a results, the $CO_2$ removal efficiency of mixed absorbent of 20 wt% of MEA with HMDA was remarkable. From this study, we concluded that the efficient separation of $CO_2$ from flue gases using the features of the Vortex tube type absorbing unit for gas/liquid contact and the separation of gas/liquid be possible. But more works are needed to increase the $CO_2$ removal efficiency of Vortex tube process.

Aerosol Jet Deposition을 이용한 기판 온도에 따른 $CuInS_2$ 박막 특성

  • Kim, Dong-Chan;Beon, Yeong;Gong, Seon-Mi;Jeong, Ji-Won
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 한국진공학회 2011년도 제40회 동계학술대회 초록집
    • /
    • pp.160-160
    • /
    • 2011
  • I-III-VI족 화합물 반도체인 $CuInS_2$(CIS) 박막은 Cu(In,Ga)$Se_2$에 비해서 독성원소를 사용하지 않으므로 환경 친화적이고 Ga, Se를 사용하지 않아 조성의 조절이 쉬우며 태양전지의 이상적인 밴드갭인 1.5 eV에 근접한 1.53 eV의 직접천이형 에너지 밴드갭을 가지고 있어 태양전지의 광흡수층으로써 유망한 재료이다. CIS 박막 증착에는 다양한 방법이 있으며 본 연구에서는 chamber를 진공으로 만들고 CIS를 구성하는 용액으로부터 미립자화 된 입자를 노즐을 통하여 팽창시켜 에어로졸을 생성하고 입자들의 운동에너지를 증착에 직접 이용 할 수 있는 Aerosol Jet Deposition (AJD)라는 방법을 이용하려고 한다. 이 방법은 높은 증착속도로 우수한 박막을 성장시킬 수 있는 저비용 및 단순공정으로 CIS를 증착 할 수 있는 새로운 방법이다. 물을 용매로 하여 수용액 상태의 $CuCl_2{\cdot}2H_2O$, $InCl_3$, $(NH_2)_2CS$를 혼합하여 CIS 용액을 제조하고 carrier gas를 주입하여 CIS 용액을 노즐로 이동시켜 팽창시킨다. 용액이 팽창되면서 온도가 감소하여 응축이 일어나며 이 응축된 용액이 가열된 기판 위에 충돌하여 용매가 증발하면서 결정화된 CIS가 증착이 된다. CIS의 특성은 용액의 전구체 비율, 기판 온도, 팽창 전 압력, chamber 압력 등의 영향을 받는데 본 연구에서는 기판 온도를 증착변수로 선택하여 CIS 박막을 증착하고 박막의 특성을 고찰하고자 한다.

  • PDF