• Title/Summary/Keyword: 용량조절

Search Result 580, Processing Time 0.032 seconds

Performance of the Flow Distribution and Capacity Modulation of a Multi-Heat Pump System (멀티형 열펌프의 유량분배 및 용량조절 특성)

  • 최종민;김용찬;하진호
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.5
    • /
    • pp.313-320
    • /
    • 2001
  • In the present study, various experiments were performed to investigate capacity modulation and refrigerant flow distribution of a multi-heat pump using a variable speed compressor and electronic expansion valves(EEVs) in the cooling mode. Based on the experimental results, it was possible to understand the interrelation of dual indoor units which provides some difficulties in capacity control of each indoor unit. The characteristics of capacity modulation of two indoor units were measured by controlling two EEVs with a cooling load of each indoor unit.

  • PDF

Capacity Modulation of a Multi-Type Heat Pump System using PID Control with Fuzzy Logic (퍼지 로직 적용 PID 제어를 이용한 멀티형 열펌프의 용량조절)

  • 김세영;김민수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.9
    • /
    • pp.810-817
    • /
    • 2001
  • Performance of a water-to-water multi-type heat pump system using R22 which has tow indoor units has been investigated experimentally. The refrigerant flow rate of each indoor unit was regulated by an electronic expansion valve and the total refrigerant flow rate of the system was controlled by a variable speed compressor. In the system, evaporator outlet pressure of refrigerant and outlet temperatures of secondary fluid from indoor units were selected as control variables. Experiments were executed for both cooling and heating modes using PID control method with fuzzy logic, and results of the test are compared with a classical PID method. In the case of PID control with fuzzy logic, the fuzzy control rules corrects PID parameters each time. Results show that PID control with fuzzy logic has the merits of quick response and reduced overshoot.

  • PDF

A study for the target water level of the dam for flood control (댐 홍수조절을 위한 목표수위 산정연구)

  • Kwak, Jaewon
    • Journal of Korea Water Resources Association
    • /
    • v.54 no.7
    • /
    • pp.545-552
    • /
    • 2021
  • The burden of flood control on the dam under frequently flood due to climate change and especially heavy flood in 2020 year are come to the forward and increased. The objective of the study is therefore to establish the method to estimate capacity and target water level for flood control in actual dam management. Frequency matching method was applied to establish a pair of cumulative distribution function (CDF) based on daily dam inflow and discharge records. The relationship between dam storage and discharge volume represented as a percentage of inflow volume was derived and its characteristics was analyzed. As the result, the Soyanggang (45%) and Chungju Dam (39%) contributing to flood control with temporarily storing flood runoff. The method and diagram to estimate flood control capacity and target water level for flood control in the dam were established. The result of the study could be used as a supplementary data for flood control of the dam according to the rainfall prediction on the Korea Meteorological Administration.

Flood control and advanced dam operation system through the improvement of operation system in the Seomjin river dam (섬진강 홍수기 댐 운영 체계개선을 통한 홍수조절 및 댐운영고도화)

  • Kim, Jin Won;Kim, Jin Woo;Kim, Jeong-Hun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.105-105
    • /
    • 2022
  • 섬진강댐은 100년빈도 홍수에 대응토록 설계되어 홍수조절 능력이 타 다목적댐 대비 상대적으로 취약함에 따라 댐운영 체계 개선이 필요하다. 이에따라 K-water는 홍수시 피해를 최소화 할 수 있도록 댐운영과 관련한 홍수대응 체계를 개선하였다. 주요 개선대책은 섬진강 홍수조절용량 추가확보, 홍수기 강우특성을 고려한 홍수조절, 하류주민 및 기관과 소통에 기반한 정보 공유체계 확립, 디지털 트윈 기반 댐 운영 의사결정시스템 구축이다. 섬진강댐의 건설홍수조절용량은 3천만m3으로, 타 다목적댐 설계빈도인 200년 대비 홍수대응 능력이 미흡하다. 이에따라, 섬진강댐은 '21.1월부터 '22.12월까지 홍수기 제한수위를 기존 197.7m에서 2.5m 낮춘 194.0m로 시범운영하고 있다. 이를통해 기존 3천만m3에서 9천만m3까지 6천만m3의 홍수조절용량을 추가 확보하였다. 이와 연계하여 홍수기 동안 섬진강댐 운영수위 기준을 별도 수립하여 홍수기 전·후반으로 나누었으며, 전반기(~7/31)는 '20년 홍수상황에서 발생한 더블피크 집중호우(360mm)에 대응가능한 홍수조절능력을 확보하고, 후반기(8/1~)는 홍수조절능력을 최대한 확보함과 동시에 차년도 용수공급을 대비할 수 있도록 운영수위를 개선하였다. 그간 수문방류 정보는 '댐 관리규정'에 따라 방류개시 3시간 전까지 방류계획을 하류지역의 지자체 및 주민에게 통보하였으나, 하류주민들이 충분히 사전준비하기에 시간적으로 부족하다는 의견을 제시함에 따라 수문방류 24시간전 사전 안내토록 '수문방류 예고제'를 도입, 시행하였다. '댐 홍수관리 소통회의'를 통해 댐 운영기관-정부기관-주민이 댐 운영에 대한 전반에 대해 함께 공유하고 운영 제약사항 및 개선사항을 공동 발굴하여 대책을 마련하는 체계를 구축하였다. 댐 운영 개선사항과 더불어 댐방류 의사결정시, 실시간 하류하천 상황에 대한 확인이 어려움에 따라, 3D기반 의사결정 지원시스템인 Digita Twin Platform을 개발 및 구축하여 '22년부터 섬진강댐 운영에 시범적용을 추진하고자 한다.

  • PDF

Electrochemical Properties of Sub-micron Size Si Anode Materials Distributed by Wet Sedimentation Method (습식 분급으로 입도 조절된 서브 마이크론 크기의 Si 음극활물질의 전기화학적 특성 분석)

  • Jin-Seong Seo;Hyun-Su Kim;Byung-Ki Na
    • Korean Chemical Engineering Research
    • /
    • v.61 no.1
    • /
    • pp.39-44
    • /
    • 2023
  • In this study, the particle size of Si polycrystals was controlled through wet-sedimentation method, and changes in the capacity and cyclic characteristics of the Si anode material according to the particle size were observed. After wet-sedimentation of Si particles pulverized by a vibration mill, the non-uniform particle distribution of Si was uniformly controlled. The d50 of a sample in which Si was sedimented for 24 hours decreased to 0.50 ㎛. As a result of the electrochemical characteristic analysis, the Rct value representing the resistance in the electrode was significantly reduced due to the decrease in particle size. The unclassified Si sample exhibited a discharge capacity of 2,869 mAh/g in the first cycle, and decreased to 85.7 mAh/g after 100 cycles. The sample in which Si was classified for 24 hours showed a capacity of 3,394 mAh/g initially, and maintained a capacity of 1,726 mAh/g after 100 cycles. As the size of the Si particles decreased, the discharge capacity increased and the cycle life was also increased.

Application of Heat Balance Model for Determination of Facilities Capacity to Overcome High Temperature in Greenhouses (온실의 고온극복설비 용량 결정을 위한 열평형 모델의 적용)

  • 남상운
    • Proceedings of the Korean Society for Bio-Environment Control Conference
    • /
    • 2000.10b
    • /
    • pp.27-30
    • /
    • 2000
  • 여름철 고온기에 시설 이용율을 높이고 안정적인 생산을 하기 위하여는 적극적인 차광 환기시스템과 증발냉각시스템을 도입하는 것이 필요하다. 이러한 시스템을 도입하기 위하여는 적정 설비용량의 결정이 중요하며, 이는 지역별 외부의 설계 기상자료로부터 구할 수 있다. 차광환기시스템에서 차광율은 작물의 종류에 따라서 결정되어야 하며 따라서, 기븐적으로 결정해야될 설계 인자는 목표온도를 달성하기 위한 필요환기율과 증발냉각시스템 의 분무수량이다. (중략)

  • PDF

Case Study for Setting Operation Rules to Irrigation Reservoirs (농업용 저수지 운영률 설정 사례 연구)

  • Noh, Jae-Kyoung
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2010.05a
    • /
    • pp.837-841
    • /
    • 2010
  • 농업용 저수지는 주로 관개용수를 공급하는 역할을 해 왔으나 4대강 살리기 사업의 저수지 둑 높이기로 확보한 저수량을 이용하여 하류하천의 유지유량 공급과 홍수조절용량으로 이용하기 위한 저수지의 운영률 설정을 요구하고 있다. 관개용수를 공급하면서 하천유지유량을 상시공급, 유량부족시 공급, 30일, 60일, 90일 집중 공급 등 시나리오별 공급효과와 홍수기 홍수조절용량을 단계별로 설정하여 각 운영효과를 분석해 저수지 운영률을 합리적으로 설정할 수 있는 방법을 검토하였으며, 탑정저수지와 미호저수지에 대해 적용한 사례를 제시하였다.

  • PDF

Design and fabrication of a Small Microstrip Antenna (소형 마이크로스트립 안테나 설계 및 제작)

  • 곽원일;박수봉;김재이;고영혁
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2001.10a
    • /
    • pp.246-249
    • /
    • 2001
  • 본 논문에서는 기존의 QMSA에 비해 안테나 전체 길이를 소형화함은 물론 전기력선이 미치는 범위가 제한받지 않도록 그라운드 판을 접어올린 좌측 평행 평판과 방사 패치사이 용량을 장하하고 급전점의 위치를 조절하여 더욱 소형화할 수 있는 용량을 장하한 QMSA를 제안하고 설계ㆍ제작했다. 설계ㆍ제작된 용량을 장하한 QMSA는 중심 주파수를 2.0GHz하고 급전점을 변화시켜서 안테나 전체 길이를 40mm에서 37mm로 소형화하였다. 또한, 급전점을 변화시켜서 용량을 장하한 QMSA의 방사 패치 길이가 17mm(equation omitted g/4)의 2배인 35.1(equation omitted g/2)로 제작된 용량을 장하한 변형된 MSA는 공진주파수가 2.16GHz로 용량을 장하한 QMSA에 비해 소형화할 수는 없으나 대역폭이 9.20 %로 매우 넓음을 보였다. 그리고 상용화된 HFSS에 의해서 QMSA, 용량을 장하한 QMSA, 변형된 MSA, 용량을 장하한 변형된 MSA등의 방사 특성과 리턴로스 특성 분석은 용량을 장하하는 안테나가 이득은 낮지만 공진 주파수가 낮아서 소형화할 수 있음을 보였다.

  • PDF

Dynamic Weight Round Robin Scheduling Algorithm with Load (부하를 고려한 동적 가중치 기반 라운드로빈 스케쥴링 알고리즘)

  • Kim, Sung;Kim, Kyong-Hoon;Ryu, Jae-Sang;Nam, Ji-Seung
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2001.10b
    • /
    • pp.1295-1298
    • /
    • 2001
  • 멀티미디어 스트리밍 서비스를 제공하는 서버의 동적 부하분산을 위한 동적 가중치 기반 라운드 로빈 스케줄링 알고리즘을 제안한다. 기존의 가중치 기반 라운드로빈 알고리즘은 서버의 처리 용량만을 이용하여 가중치를 부여하므로 요청이 폭주할 경우 동적 부하 불균형을 갖게 된다. 동적 부하 불균형을 해결하기 위해 제안한 동적 가중치 기반 라운드로빈 알고리즘은 서버의 처리 용량뿐만 아니라 서버의 동적 부하를 이용하여 가중치를 부여하므로 동적 부하 불균형에 잘 적응하여 부하를 균형있게 조절한 수 있다. 제안한 알고리즘은 각 서버의 처리용량을 기준으로 가중치를 계산하고 동적으로 변하는 서버의 부하값에 가중치를 적용한다. 그 결과 동적 부하 불균형 문제를 해결했으며, 더 세밀한 부하 조절 기능을 수행할 수 있었다

  • PDF

External Ballast Capacitor를 통해 발생된 아크 방전의 특성 분석

  • Son, Ji-Han;Ha, Chang-Seung;Kim, Dong-Hyeon;Lee, Hae-Jun;Lee, Ho-Jun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.490-490
    • /
    • 2012
  • Ballast capacitor에 저장된 에너지로 방전 에너지를 조절할 수 있는 방전장치를 개발하였다. 본 연구에서는 ballast capacitor의 용량을 조절하여 micro-size의 아크 플라즈마를 발생시켰으며, 용량변화에 따른 플라즈마의 온도를 측정하였다. 또한 ICCD camera를 이용하여 ballast capacitor의 용량변화에 따른 cathode의 변화를 관찰하였다. Optical Emission Spectroscopy를 통하여 플라즈마의 광학적 특성을 분석하였다. 마이크로 아크 방전의 주파수를 높이기 위하여 switching device를 병렬로 연결하여 아크 플라즈마를 구동시켰으며, 발생된 마이크로 아크 플라즈마는 정밀방전 가공에 응용되었다. 본 연구는 2011년도 지식경제부의 재원으로 한국에너지 기술평가원(KETEP)의 지원을 받아 수행한 연구 과제입니다(No. 20104010100670).

  • PDF