• Title/Summary/Keyword: 용량변동

Search Result 290, Processing Time 0.03 seconds

Nitric Oxide/cGMP-Independent Vasorelaxation Enhanced by L-Arginine (L-Arginine의 산화질소생성과 무관한 혈관이완효과)

  • 문승호;이종은;유광재;오봉석;이동준
    • Journal of Chest Surgery
    • /
    • v.31 no.2
    • /
    • pp.102-107
    • /
    • 1998
  • It has not been clear whether L-arginine plays solely a role contributing to vascular nitric oxide (NO) synthesis. To investigate the mechanisms by which L-arginine induces vasorelaxation, effects of L-arginine on the isometric tension, and tissue NOx and cyclic guanosine monophosphate(cGMP) contents were examined in the isolated rat thoracic aorta. L-Arginine induced a dose-dependent relaxation of aortic rings only with intact endothelium only. The vasorelaxation response to low concentrations of L-arginine was abolished by the pretreatment with NG-nitro-L-arginine methyl ester(L-NAME, 10-4 mol/L), whereas the relaxation caused by higher concentrations L-arginine(10-5-10-3 mol/L) was maintained and even more pronounced in the presence of L-NAME. L-Arginine did not affect the vascular tension precontracted with KCl. The vascular tissue contents of NOx/cGMP were not significantly affected by L-arginine, while they were decreased by L-NAME. L-Arginine could not completely recover the NOx/cGMP decreased by L-NAME. Methylene blue only partially antagonized the relaxation response to L-arginine. Indomethacin did not affect the L-arginine-induced vasorelaxation, whereas ouabain markedly attenuated the relaxation. It is suggested that L-arginine induces vasorelaxation not only through its contribution to NO synthesis, but also through enhancing another endothelium-dependent mechanism which is NO/cGMP-independent and cyclooxygenase- independent.

  • PDF

The Effect of Long-term Application of different Organic Material Sources on Soil Physical Property and Microflora of Upland Soil (유기물원이 다른 퇴비연용이 밭토양의 물리성 및 미생물상 변화에 미치는 영향)

  • Kim, Jong-Gu;Lee, Sang-Bok;Kim, Seong-Jo
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.34 no.5
    • /
    • pp.365-372
    • /
    • 2001
  • The objective of this study was to determine the effects of various kinds of composts on the change of soil physical properties and microorganism in upland soils. Field experiments were conducted in the loam and sandy loam soils, while the clay loam and sandy loam soils were used for laboratory experiments. Various kinds of composts such as poultry manure compost(PMC). cow manure compost(CMC). human excrement sludge(HES), and food industrial sludge compost(FISE) were applied annually at rates of 0, 40, and $80Mg\;ha^{-1}$ to soils grown with soybean and maize plants for 4 years during 1994 to 1997. The results of this study were as follows : Bulk density of loam soil decreased with compost application to $1.07{\sim}1.32Mg\;m^{-3}$ compared with $1.49Mg\;m^{-3}$ of control plot, while in sandy loam soil it decreased to $1.00{\sim}1.20Mg\;m^{-3}$ compared with $1.25Mg\;m^{-3}$ of control plot. Bulk density of soil was decreased according to maize cultivation compared with bare control, but soybean cultivation was similar. Population of organic material decomposing microorganisms was increased rapidly at the initial incubation stage at $25^{\circ}C$, and increased more sensitively at the loam soil than sandy loam soil. In the case of the change of microorganisms associated with nitrogen circulation, ammonia oxidizing bacteria was more at the initial incubation stage, and denitrifying bacteria was more at the initial incubation stage, and denitrifying bacteria increased until 1~4 weeks after incubation and increased more at the loam soil than sandy loam soil.

  • PDF

A study on the Sediment Specific Properties of the Basin of Im-Jin River (임진강 유역의 유사특성에 관한 연구)

  • Shin, Sang-Ik;Park, Ji-Hyun;Lee, Eun-Tae
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2007.05a
    • /
    • pp.1670-1676
    • /
    • 2007
  • 본 연구는 임진강 유역을 대상유역으로 대표지점을 선정하고 각 지점의 하상변동 예측, 저수지 퇴사량 추정, 유사 유출량 추정, 하상 상승 및 유수소통단면 축소에 따른 홍수범람규모의 증대, 저수지 용량 감소 및 상수원 취수구 매몰 등의 원인인 유사퇴적에 대한 신뢰성 있는 자료를 실측하여 제시하고자 한다. 실측된 유사량의 특성을 알아보고자 각 대표지점 별로 동일한 유량 시 유사량을 비교하여 유사량과 각 지형 인자들과의 상관관계를 분석함으로써 임진강 유역의 특성이 반영된 유사량 산정에 관한 기초이용 자료로 활용 제시하여 수자원 개발 및 관리에 보다 효율적으로 적용하는데 목적이 있다. 임진강 유역의 대표지점으로는 적성, 군남, 전곡지점을 선정하였고, 임진강 유역 대표지점의 특성으로는 적성지점(유역면적:$6,800.2km^2$, 유로연장:224.5km), 군남지점(유역면적:$4,228.5km^2$, 유로연장:204.9km), 전곡지점(유역면적:$2,152.9km^2$, 유로연장:133.0km)이다. 총유사량의 산정은 부유사와 소류사의 양을 더하여 산정하는 것이 가장 이상적이나 소류사의 채취가 어렵고 정확도가 떨어지기 때문에 채취한 부유사량에 수정 아인쉬타인 방법 등을 이용하여 구한 소류사를 더해 총유사량을 추정하는 것이 일반적이다. 따라서 본 연구에서는 임진강 유역에서는 실측한 부유사량에 수정 아인쉬타인 방법으로 추정한 소류사량을 더한 총유사량을 구하여 분석하였고, 기타 다른 유사량산정 공식들과 비교 분석하여 보았다. 부유사 농도분석 방법으로는 저농도(10,000ppm)인 시료에 적합한 여과법을 이용하여 분석하였으며, 유사 입경분포 분석방법으로는 BW관 방법을 이용하여 분석하였다. 현재까지 국내 외적으로 하천 유사량 산정과 관련된 많은 경험식들이 제시되고 있다. 하지만, 외국의 충적하천에 기초하여 개발되어진 유사량 공식들을 우리나라 하천에 무분별하게 적용하는 것은 위험스러우며, 유사량 산정 결과의 신뢰성을 높이기 위해서는 무엇보다 우리나라 하천의 지형, 수리, 수문학적 요소들이 유사 특성에 미치는 영향을 알아야 한다. 그러므로, 본 연구에서는 실측을 통한 유사량 값을 하천의 지형, 수리, 수문학적 요소들과 비교 분석하여우리나라 하천에 맞는 유사특성을 알아보고, 기타 총유사량산정 공식을 이용하여 실측한 유사량과 비교 분석하고자 한다.

  • PDF

GVT, Inc.의 HP Series 2단 Gifford-McMahon 극저온 냉동기 성능시험

  • Lee, Dong-Ju;Han, Myeong-Hui;Mun, Jae-Yeong;In, Sang-Ryeol
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.227-227
    • /
    • 2012
  • Cryopump는 반도체 임플란타 공정, OLED분야, 신소재 개발, 표면분석 및 처리, 의료분야, 입자가속기, 핵융합 등 다양한 진공분야에 응용되는 고진공용 극저온펌프이다. 특히 향후로의 산업구조는 디스플레이, 반도체, IT 산업분야로 집중 재편될 것이기에, 이에 따른 핵심제조장비인 고진공 펌프의 수요가 급증할 것으로 판단된다. 그리고 이를 위한 핵심부품과 장비들의 국산화가 시급한 실정이다. 기술적인 측면에서 보자면 GVT는 미국의 Varian과 일본Ebara의 Cryopump 제조기술을 원천으로 한 회사로써 현재는 국내 유일의 G-M냉동기와 Cryopump 제조기술을 보유한 업체이다. 그리고 최근 오랫동안 정체되었던 관련 기술을 발전시켜 최적화된 한국형 G-M 냉동기 및 이를 장착한 다양한 사이즈의 고성능 Cryopump를 출시하게 되었다. 가장 큰 수확은 Cryopump의 성능을 크게 향상시켰으며 무엇보다 고객맞춤형으로 디자인할 수 있을 정도의 기술력을 확보하게 되었다는 점이다. Cryopump의 성능은 장착되는 Cryocooler(G-M냉동기)의 성능과 밀접한 관련이 있기 때문에 일차로 Cryocooler의 성능을 개선하고 이차로 이를 장착한 Cryopump의 성능을 개선하였다. 본 연구는 일차로 진행된 HP Series 2단 Cryocooler 4가지 모델 중 가장 범용인 HPM 모델과 HPS모델에 대한 제작과 성능시험에 관한 것이다. 이는 각각 기존의 ICP Series 펌프에 장착되던 Expander 535 모델 및 Expander 855 모델에 대한 설계 최적화의 결과물로써 내용은 Cryocooler에 대한 'Typical Performance Test(1st STG와 2nd STG의 온도가 각각의 Stage에 인가되는 Heat Load에 의해 그물망 형태의 그래프가 되도록 수행하는 시험법)'의 절차를 따라 수행되었다. HPM Cryocooler의 성능은 2nd STG Temp. 20K 와 1st STG Temp. 80K를 Heat Load 기준으로 하였을 경우, 각각 8.2W, 55.0W의 성능을 나타내었고 HPS Cryocooler의 성능은 2nd STG Temp. 20K 와 1st STG Temp. 72K를 Heat Load기준으로 하였을 경우, 각각 14.0W, 90.0W의 성능을 나타내었다. 1st STG Temp.를 72K로 정한 이유는 Power Supply의 용량 한계로 인해 90W이상의 Heat Load를 인가할 수 없었기 때문이다. 만약 성능 그래프의 경향성을 고려하여 1st STG Temp. 80K로 가정한다면, 각각 약 13W, 100W 정도의 성능을 가질 것으로 추정된다. 단, 본 시험에 사용된 Compressor는 GVT의 HC80Plus 모델로 내부에는 Helium용 5HP급 Scroll Type의 Compressor가 장착되어 있으며, 봉입압력 250Psig에 저압 100Psig기준, 65scfm의 유량을 가지는 압축기이다. 압축기와 Cryocooler의 조합은 1:1이었고 시험방법은 Cryocooler에 대한 GVT 자체규정에 따라 진행되었으며 밤과 낮 및 공장전체의 부하변동에 따른 냉각수 온도변화에 따른 펌프의 성능변화는 고려되지 않았다.

  • PDF

GVT, Inc.의 HP Series 2단 Gifford-McMahon 극저온 냉동기 성능시험

  • Lee, Dong-Ju;Han, Myeong-Hui;Mun, Jae-Yeong;In, Sang-Ryeol
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.118-118
    • /
    • 2012
  • Cryopump는 반도체 임플란타 공정, OLED분야, 신소재 개발, 표면분석 및 처리, 의료분야, 입자가속기, 핵융합 등 다양한 진공분야에 응용되는 고진공용 극저온펌프이다. 특히 향후로의 산업구조는 디스플레이, 반도체, IT 산업분야로 집중 재편될 것이기에, 이에 따른 핵심제조장비인 고진공 펌프의 수요가 급증할 것으로 판단된다. 그리고 이를 위한 핵심부품과 장비들의 국산화가 시급한 실정이다. 기술적인 측면에서 보자면 GVT는 미국의 Varian과 일본Ebara의 Cryopump 제조기술을 원천으로 한 회사로써 현재는 국내 유일의 G-M 냉동기와 Cryopump 제조기술을 보유한 업체이다. 그리고 최근 오랫동안 정체되었던 관련 기술을 발전시켜 최적화된 한국형 G-M 냉동기 및 이를 장착한 다양한 사이즈의 고성능 Cryopump를 출시하게 되었다. 가장 큰 수확은 Cryopump의 성능을 크게 향상시켰으며 무엇보다 고객맞춤형으로 디자인할 수 있을 정도의 기술력을 확보하게 되었다는 점이다. Cryopump의 성능은 장착되는 Cryocooler (G-M냉동기)의 성능과 밀접한 관련이 있기 때문에 일차로 Cryocooler의 성능을 개선하고 이차로 이를 장착한 Cryopump의 성능을 개선하였다. 본 연구는 일차로 진행된 HP Series 2단 Cryocooler 4가지 모델 중 가장 범용인 HPM 모델과 HPS모델에 대한 제작과 성능시험에 관한 것이다. 이는 각각 기존의 ICP Series 펌프에 장착되던 Expander 535 모델 및 Expander 855 모델에 대한 설계 최적화의 결과물로써 내용은 Cryocooler에 대한 'Typical Performance Test(1st STG와 2nd STG의 온도가 각각의 Stage에 인가되는 Heat Load에 의해 그물망 형태의 그래프가 되도록 수행하는 시험법)'의 절차를 따라 수행되었다. HPM Cryocooler의 성능은 2nd STG Temp. 20K와 1st STG Temp. 80K를 Heat Load기준으로 하였을 경우, 각각 8.2W, 55.0W의 성능을 나타내었고 HPS Cryocooler의 성능은 2nd STG Temp. 20K 와 1st STG Temp. 72K를 Heat Load기준으로 하였을 경우, 각각 14.0W, 90.0W의 성능을 나타내었다. 1st STG Temp.를 72K로 정한 이유는 Power Supply의 용량 한계로 인해 90W이상의 Heat Load를 인가할 수 없었기 때문이다. 만약 성능 그래프의 경향성을 고려하여 1st STG Temp. 80K로 가정한다면, 각각 약 13W, 100W 정도의 성능을 가질 것으로 추정된다. 단, 본 시험에 사용된 Compressor는 GVT의 HC80Plus 모델로 내부에는 Helium용 5HP급 Scroll Type의 Compressor가 장착되어 있으며, 봉입압력 250Psig에 저압 100Psig기준, 65scfm의 유량을 가지는 압축기이다. 압축기와 Cryocooler의 조합은 1:1이었고 시험방법은 Cryocooler에 대한 GVT 자체규정에 따라 진행되었으며 밤과 낮 및 공장전체의 부하변동에 따른 냉각수 온도변화에 따른 펌프의 성능변화는 고려되지 않았다.

  • PDF

A Study on the Optimization of District Heating and Cooling Facilities (지역냉난방사업의 설비 최적화에 관한 연구)

  • Kim, Jin Hyung;Choi, Byung Ryeal
    • Environmental and Resource Economics Review
    • /
    • v.15 no.3
    • /
    • pp.505-530
    • /
    • 2006
  • For the district heating and cooling business, it is required to install energy-saving facilities using energy from waste and land fill gases such as combined heat and power(CHP). The current issues that this business faces can be summarized as below: which facilities including CHP can be economically introduced and how much of their capacities should be. Most of such issues are clearly related to the optimal plant design of the district heating and cooling business, and the prices of energy services such as heating and cooling energy, and electricity. The purpose of this study is to establish linear program model of least cost function and to practice the empirical test on a assumed district heating and cooling business area. The model could choose the optimal type of energy-producing facilities among various kinds available such as CHP's, absorption chillers, the ice-storage system, etc. CHP with the flexible heat and power ratio is also in the set of available technologies. And the model show us the optimal ration of heat producing facilities between CHP and historical heat only boiler in the service area. Some implications of this study are summarized as below. Firms may utilize this model as a tool for the analysis of their optimal size of the facilities and operation. Also, the government may refer the results to regulate resonable size of business.

  • PDF

Economic Impact Analysis on High-yield Groundwater Development R&D Project in Jeju (제주도 청정 대용량 지하수개발 연구사업의 경제적 효과분석)

  • Ahn, Eun-Young;Kim, Seong-Yong
    • Economic and Environmental Geology
    • /
    • v.42 no.2
    • /
    • pp.133-141
    • /
    • 2009
  • For economic impact analysis on a R&D project of high-yield groundwater development in Jeju conducted by KIGAM from 2004 to 2007, benefit/cost ratio(BCR), net present value(NPV), and internal rate of return(IRR) were calculated by contingent valuation method(CVM), production function analysis, domestic water market analysis and technology factor analysis. Measurable direct impact parameters among the major outputs of this R&D project consisted the estimation 4 high-yield and high mineral groundwater reserve in Jeju. Annual use of the reserve by piped water and bottled water was estimated as 12.23 million ton and its monetary value was calculated as 293.4 million dollar in 2006 year value applied of 5.5% discount rate. Economic impact of this R&D project in NPV of year 2006, with applying a discount rate of 5.5%, was identified and estimated as 13.66 million dollar in NPV, 4.05 points in BCR, and 22.74% in IRR, respectively. Additional early launch benefit was 5.58 million dollar. Even increased of the 1% discount rate, NPV of this R&D project was also positive as 12.18 million dollar and BCR was 3.71.

Estimation of Carrying Capacity in Kamak Bay( I ) - Estimation of Primary Productivity Using the Eco-hydrodynamic Model- (가막만의 환경용량 산정( I ) -생태계모델을 이용한 기초생산력 산정-)

  • CHO Eun Il;PARK Chung Kil;LEE Suk Mo
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.29 no.3
    • /
    • pp.369-385
    • /
    • 1996
  • The eco-hydrodynamic model was used to estimate the primary productivity of the oyster culture grounds in Kamak Bay. It is composed of the three-dimensional hydrodynamic model for the simulation of water flow and ecosystem model for the simulation of phytoplankton. The ecosystem model was applied to simulate phytoplankton biomass during culturing period in condition of no oyster culture grounds. The field surveys were conducted from May, 1994 to March, 1995 in Kamak bay. The results showed the concentration of chlorophyll $\alpha$ to be $1.00\~23.28\;{\mu}g/l$ in the surface layer, $1.27\~29.97\;{\mu}g/l$ in the middle layer and $1.23\~23.08\;{\mu}g/l$ the bottom layer. In monthly variations of chlorophyll $\alpha$ concentration, very high concentration were found in July, 1994 and very low concentrations in December, 1994. As the results of three-dimensional hydrodynamic simulation, the computed tidal currents ave mainly toward the inner part of bay through Yeosu Harbor and the southern mouth of a bay during the flood tide. The computed residual currents were dominated southward in Yeosu Harbor and eastward in the mouth of bay and also showed strong clockwise water circulation at the mouth of bay. The pattern between the simulated and observed tidal ellipses at three stations was very similar. The mean relative errors of all levels between the simulated and observed phytoplankton biomass at 14 stations in Kamak Bay were $13.81\%,\;9.31\%\;and\;17.84\%$, respectively. The results of phytoplankton biomass simulation showed that the biomass increased from June to September and rapidly decreased to December and then slowly increased to March. Primary productivity was estimated in the range of $0.99\~10.20gC/m^2/d$ with the average value of $4.43gC/m^2/d$ in condition of no oyster culture grounds. Primary productivity was rapidly increased from lune to August and rapidly decreased to December and then slowly increased from January to March in Kamak Bay.

  • PDF

Power Generation Cost Comparison of Nuclear and Coal Power Plants in Year 2001 under Future Korean Environmental Regulations -Sensitivity and Uncertainty Analysis- (미래의 한국의 환경규제여건에 따른 2001년도의 원자력과 석탄화력 발전단가비교 -민감도와 불확실도 분석-)

  • Lee, Byong-Whi;Oh, Sung-Ho
    • Nuclear Engineering and Technology
    • /
    • v.21 no.1
    • /
    • pp.18-31
    • /
    • 1989
  • To analyze the impact of air pollution control on electricity generation cost, a computer program was developed. POGEN calculates levelized discounted power generation cost including additional air pollution control cost for coal power plant. Pollution subprogram calculates total capital and variable costs using governing equations for flue gas control. The costs are used as additional input for levelized discounted power generation cost subprogram. Pollution output for Rue Gas Desulphurization direct cost was verified using published cost data of well experienced industrialized countries. The power generation costs for the year 2001 were estimated by POGEN for three different regulatory scenarios imposed on coal power plant, and by levelized discounted power generation cost subprogram for nuclear power. Because of uncertainty expected in input variables for future plants, sensitivity and uncertainty analysis were made to check the importance and uncertainty propagation of the input variables using Latin Hypercube Sampling and Multiple Least Square method. Most sensitive parameter for levelized discounted power generation cost is discount rate for both nuclear and coal. The control cost for flue gas alone reaches additional 9-11 mills/kWh with standard deviation less than 1.3 mills/kWh. This cost will be nearly 20% of power generation cost and 40% of one GW capacity coal power plant investment cost. With 90% confidence, the generation cost of nuclear power plant will be 32.6-51.9 mills/kWh, and for the coal power plant it will be 45.5-50.5 mills/kWh. Nuclear is favorable with 95% confidence under stringent future regulatory requirement in Korea.

  • PDF

Application of MPI Technique for Distributed Rainfall-Runoff Model (분포형 강우유출모형 병렬화 처리기법 적용)

  • Chung, Sung-Young;Park, Jin-Hyeog;Hur, Young-Teck;Jung, Kwan-Sue
    • Journal of Korea Water Resources Association
    • /
    • v.43 no.8
    • /
    • pp.747-755
    • /
    • 2010
  • Distributed Models have relative weak points due to the amount of computer memory and calculation time required for calculating water flow using a numerical analysis based on kinematic wave theory when compared to the conceptual models used so far. Typically, the distributed models have been mainly applied to small basins. It was necessary to decrease the resolution of the grid to make it applicable for large scale watersheds, and because it would take up too much time to calculate using a higher resolution. That has been one of the more difficult factors in applying the model for actual work. In this paper, MPI (Message Passing Interface) technique was applied to solve the problem of calculation time as it is one of the demerits of the distributed model for performing physical and complicated numerical calculations for large scale watersheds. The comparison studies were performed a single domain and a divided small domain in Yongdam Dam watershed in case of typoon 'Ewiniar' at 2006. They were compared to analyze the application effects of parallelization technique. As a result, a maximum of 10 times the amount of calculation time was saved but keeping the level of quality for discharge by using parallelization code rather than a single processor.