• Title/Summary/Keyword: 용량변동

Search Result 290, Processing Time 0.022 seconds

Prediction Model for Accumulation and Decline of Exchangeable Potassium in Upland Soil with Long-Term Application of Fertilizer Potassium (가리질비료(加里質肥料) 연용(連用) 고추재배(栽培) 밭토양(土壤)의 치환성가리함량(置換性加里含量) 변동양상(變動樣相) 예측방법(豫測方法))

  • Jung, Beung-Gan;Yoon, Jung-Hui;Hwang, Ki-Sung
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.29 no.4
    • /
    • pp.342-346
    • /
    • 1996
  • Field experiments were conducted to investigate the mode of changes in exchangeable K contents in the soil under the continued(for three years) application of different levels of K fertilizer(KCl) with and without application of conventional compost(CC) and chicken-dung derived compost (CDC) for red pepper cultivation at two field parcels with different exchageable K contents on Gopyong silty loamy soil. The application of KCl at standard rate for red-pepper resulted in the increase in exchangeable K in the soil after each harvest of the crop. while no application of K and the application of KCl at one half of the standard rate tended to lower the exchangeable K in top soil with the cultivation of the crop. The application of compost in addition to KCl ammplified the difference in exchangeable K in the soil before and after the harvest of each crop. An equation could resonably well predict the exchageable K content in top soil after the years of crop cultivation, under different treatments. were developed.

  • PDF

Serologic follow-up Study in neurocysticercosis patients by ELISA after praziquantel treatment (프라지콴텔 치료후 효소면역측정법에 의한 뇌 유구낭미충증 환자의 혈청학적 추적검사)

  • Cho, Seung-Yull;Kim, Suk-Il;Kang, Shin-Yong
    • Parasites, Hosts and Diseases
    • /
    • v.24 no.2
    • /
    • pp.159-170
    • /
    • 1986
  • A total of 69 patients of confirmed neurocysticercosis was followed serologically by ELISA up to 22 months after praziquantel treatment. The intervals and numbers of follow-up were variable by patient. Serially collected samples of serum and CSF were examined simultaneously for their specific IgG antibody levels by ELISA, using cystic fluid, saline extracts of bladder wall and scolex as antigen. Within 4 months after praziquantel treatment, the antibody levels were elevated temporarily in both serum and CSF in most patients. In some cases antibody levels exhibited steady declining tendency after the treatment. Concomitant administration of dexamethasone appeared to suppress the elevation of antibody levels. The rate of mean absorbance of antibody changed more in serum than in CSF. The rate of elevation was greater in antibodies to parenchymal antigens than that to cystic fluid, but absolute difference of antibody levels was greater in antibody to cystic fluid. Previously negative samples for IgG antibody may become positive after the praziquantel treatment, which could be used as a complementary tool (provocation test) in serodiagnosis. One month was considered to be sufficient interval for the follow-up test for that purpose. In the follow-up of up to 22 months, only few cases of chronic neurocysticercosis showed declining tendency of IgG antibody levels below negative range. During acute encephalitic attacks in chronic patients, IgG antibody to parenchymal antigen were elevated in CSF temporarily. These results indicated that serologic follow-up of every year was recommendable to differentiate the cured patients from chronic patients with slowly calcifying lesions.

  • PDF

3-Phase Power Quality Disturbance Generator with Phase Jump Function (위상급변 기능을 갖는 3상 전력품질 외란발생기)

  • Lee, B.C.;Choi, S.H.;Paeng, S.H.;Park, S.D.;Choi, N.S.;Kim, I.D.;Chun, T.W.;Kim, H.G.;Nho, E.C.
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.11 no.5
    • /
    • pp.463-470
    • /
    • 2006
  • This paper deals with a new 3-phase power quality disturbance generator. The proposed generator can provide phase jump as well as voltage sag, swell, outage, unbalance, and over and under voltage. The operating principle of the generator is described in each mode of disturbance. The magnitude of the phase jump is analysed and it is found that the magnitude is the function of the turn-ratios of the transformers consisting the generator. The scheme has simple structure compared with the conventional one, and the major components of the proposed scheme are SCR thyristor and transformer, which guarantees high reliability and cost-effective implementation of the generator. Furthermore, high efficiency can be obtained because there is no PWM switching of the semiconductor devices, and it is easy to control the system. Simulations are carried out to confirm the operation in each disturbance mode, and experiments has been done with 5kVA power rating. The usefulness of the proposed scheme is verified through simulation and experimental results. It is expected that the scheme can be applied to the performance test of the custom power devices such as UPS, DVR, DSTATCOM, and SSTS with cost-effective system.

Flow Analysis and an Experimental Study on Formation of Slurry Ice in the Reversing Flow Layer (역전 유동층 내의 유동해석 및 슬러리아이스 생성에 관한 연구)

  • Oh, Cheol;Choi, Young-Gyu
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.4
    • /
    • pp.421-428
    • /
    • 2011
  • Thermal energy storage(TES) cooling system using cheaper electricity of off-peak time has been applied to relieve a significant portion of the peak demand of electricity during the daytime in summer. Slurry ice type thermal energy storage cooling system is one kind of more efficient ice-thermal energy storage cooling system than Ice-on-Coil type or Encapsulated type TES cooling system, even though, which are more popular TES system. This experimental study was carried out to observe flow pattern and formation of slurry ice in reversing flow layer to improve efficiency of heat transfer between fluid and freezing tube and to disturb ice adhesion on tube surface. The reversing flow layer was made by using reversing materials in heat exchanger section(test section) to disturb ice adhesion. At this experiment, styrofoam balls and poly propylene balls were used as reversing materials, and a 20wt% solution of ethylene glycol was used as reversing flow layer. The experimental apparatus was constructed of the test section for making/storing slurry ice, the brine tank, pumps for circulating of a 20wt% solution of ethylene glycol and brine, a flow-meter, a data logger for measuring the temperature. The experiments were carried out under various conditions, with volumetric flow rate, ball filling rate and air filling rate.

A Study on the Relation Characteristics between Bubble Size Distribution and Floating Time (버블의 크기별 입도분포와 부상시간과의 상관특성에 관한 연구)

  • Jeon, Gun;Park, Chul-Hwi
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.39 no.5
    • /
    • pp.277-281
    • /
    • 2017
  • Lately rainfall characteristics that it rains a lot in a short space of time often occurs. Because of this meteorological phenomena, the flow rate and concentration of initial rainfall for runoff and combined sewer overflows are changed. In the case of this inlet fluctuation, the flotation method at high surface loading rate is suitable for water quality management. the flotation method is able to meet the removal rate requirements of water public zone in 5 to 10 min which is irelatively short period. For assessment and diagonision of flotation method, A/S ratio is applied until now. But unfortunately, this has some limits for evaluation standard for certification and assessment of technical diagnosis and operation. This is why there is different efficiency in the bubble distribution at the same A/S ratio. The velocity and time of floating is changed by the different bubble distributions. The floating time affects the plant volume because the time factor make size dicision. Therefore the charateristics of bubble distribution and floating time at the same A/S ratio is necessary to apply to evaluation standard for certification and assessment of technical diagnosis and operation. For generalization of the method in certification and assessment, the characteristics of bubble distribution was studied. Until recently, using the optical device and shooting live video, there are some analysis technology of the floating factors. But this kind of technology is influenced by the equipment. with this level of confidence about the results, it is difficult to apply to generalize. According this reasons, this study should be applied on experiment generalization of method about measurement of relation between bubble distribution and floating time.

A Study on Establishment of Buffer Zone of Radioactive Waste Repository (방사성패기물 처분시설에서의 완충공간 설정에 대한 고찰)

  • Yoon, Jeong-Hyoun;Park, Joo-Wan;Ju, Min-Su;Kim, Chang-Lak;Park, Jin-Baek
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.6 no.1
    • /
    • pp.45-54
    • /
    • 2008
  • A new proposed repository has a final capacity of 800,000 drums radioactive waste. Most of foreign repositories have a general practice of segregating control zones which mainly contributes to classification of degree of control, whether it is called buffer zone or not. Domestic regulatory requirements of establishment of buffer zone in a repository are not much different from those of nuclear power plants for operation period, in which satisfactory design objective or performance objective is the most important factor in determination of the buffer zone. The meaning of buffer zone after closure is a minimum requested area which can prevent inadvertant intruders from leading to non-allowable exposure during institutional control period. Safety assessment with drinking well scenario giving rise to the highest probability of exposure among the intruder's actions can verify fulfillment of the buffer zone which is determined by operational safety of the repository. At present. for the repository to be constructed in a few years, the same procedure and concept as described in this paper are applied that can satisfy regulatory requirements and radiological safety as well. However, the capacity of the repository will be stepwise extended upto 800,000 drums, consequently its layout will be varied too. Timely considerations will be necessary for current boundary of the buffer zone which has been established on the basis of 100,000 drums disposal.

  • PDF

Hemoglobin Concentration in Female Workers of Occupational Exposure to Lead (연 취급 근로자들의 혈색소치의 변동)

  • Park, Nan-Kyu;Kang, Pock-Soo;Chung, Jong-Hak
    • Journal of Yeungnam Medical Science
    • /
    • v.3 no.1
    • /
    • pp.73-79
    • /
    • 1986
  • This study was conducted to evaluate the effects of lead on the incidence of anemia and to find cases with lead poisoning early among female workers who have been exposed to lead occupationally, for one year from August, 1985. The level of blood lead and hemoglobin concentration were observed for 284 female lead workers and 123 female non-lead workers of industries in the Gumi industrial complex in Kyungpook Province. The average age was $20.3{\pm}2.9$years and $21.1{\pm}3.5$ years in lead workers and non-lead workers, respectively. The average working duration was $26.46{\pm}19.26$ months in lead workers. The mean value of blood lead was $30.11{\pm}6.61{\mu}g/100ml$ and $21.86{\pm}3.75{\mu}g/100ml$ in lead workers and non-lead workers, respectively. There were significant differences between two groups. The mean value of hemoglobin concentration was $14.00{\pm}0.57g/100ml$ and $14.03{\pm}0.64g/100ml$ in lead workers and non-lead workers, respectively. Anemia cases were not observed at Hb concentration below 12g/100ml. The percentages of lead workers at Hb concentration ranged 12.0~13.0g/100ml were 4.5%. There was no dose-response relationship between blood lead level and the incidence of anemia. There were no remarkable differences between age and blood lead level as well as Hb concentration, and between working duration and the level of blood lead and hemoglobin.

  • PDF

A Feasibility Study on Optimization System of Coagulant Dosing for Total Phosphorous Treatment (총인 처리를 위한 응집제 주입량 최적제어 시스템의 적용성 연구)

  • Seo, Jeong-Mi;Cho, Young-Beom;Choi, Ye-Mook;Park, Chul-Hwi
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.7
    • /
    • pp.483-491
    • /
    • 2014
  • In this study, we developed an M-COS (molit coagulant-dosing optimization system), which enables to apply the optimum coagulant dose determined in real time, in order to satisfy the total phosphorus (TP) regulation (0.5 mg/L), and then tested its field applicability. Field tests were conducted at three different periods in 2014 in a pilot plant where the M-COS was installed. Coagulant reduction rate by the M-COS was 10.4%, 15.3%, and 9.0% for each period (average 11.6%), when comparing with a control where coagulants were applied at a constant rate. Total cost for the M-COS or control was estimated by summing up the coagulant cost and sludge treatment cost, and then the resulting cost increase was predicted. Cost reduction rate by the M-COS was 13.8%, 20.0%, and 11.4% for each period (average 15.0%). This study indicates that the M-COS can be an alternative to a conventional system for TP treatment, with a better cost efficiency.

A Study on the Cause of Noise and Vibration of an Elevator (엘리베이터 소음 및 진동의 원인에 관한 연구)

  • 이성춘;김준호;김두훈
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1994.04a
    • /
    • pp.94-99
    • /
    • 1994
  • 최근 인구의 과밀화와 이에 따른 지가의 상승 등으로 대표적인 주거용 빌딩인 아파트의 고층화가 급속하게 진행되고 있고 아파트에 설치되는 엘리베이터도 점차 대형화, 고속화 되고 있다. 실례로 15층 아파트의 경우 11인승, 60m/min의 엘리베이터가 일반적으로 사용되는 반면, 20층 아파트의 경우 17인승, 90m/min이 주로 사용된다. 이와 같이 엘리베이터의 용량과 운행 속도가 증가함에 따라 필연적으로 소음 및 진동 문제가 발생하게 된다. 특히 아파트의 경우 침실, 공부방 등 고도의 정숙을 요하는 생활 공간이 많고, 내부 공간의 활용도를 높이기 위하여 이들 방들이 엘리베이터 기계실 또는 운행 통로와 직접 접하여 있는 경우도 있어 이 경우 소음, 진동 문제는 아주 심각한 문제로 대두된다. 본 연구소가 측정한 방에 의하면 S신도시 L아파트의 경우 아파트 최상층 방에서 실내 소음도가 46dB(A), 벽의 진동가속도가 3.4mm/s$^{2}$(RMS)으로 나타났다. 진동의 경우 생활에 직접적인 악영향을 미칠 수준은 아니지만 소음의 경우 ASHRAE 권장 주택소음 기준치가 35dB(A) 이하임ㅇㄹ 감안하면 주거에 곤란한 수준이다. 수년전, 고층 아파트가 보급될 초기에는 아파트에 엘리베이터가 설치되어있다는 그 자체만으로 충분한 장점이 되어 다소음 소음, 진동문제는 큰 불만거리가 되지 않았지만 엘리베이터가 보편화된 지금에는 엘리베이터의 편리성만으로는 점점더 크게 요구되는 정숙성이 보상되지 않는다. 따라서 전반적인 아파트의 소음, 진동 문제에 큰 비중을 차지하는 엘리베이터에 의한 소음, 진동에 관하여 체계적인 연구가 필요하다. 이에 본고에서는 엘리베이터에 의한 아파트의 소음 및 진동에 관하여 그 현황, 원인 그리고 대책에 관한여 논하고자 한다.감 방법을 연구하였고, T.Sakai는 5자유도 모델을 이용하여 엔진 공회전시 발생하는 치타음에 대해 이론과 실험을 통해 해석하고, 엔진 회전수 변동, 클러치 특성, 변속기의 드래그(drag) 토크의 영향과 치타음 저감을 위한 개선된 클러치 특성을 제시하였다. 이 외에도 Thomas C.T.와 E.P.Petkus는 특정 차량에 대한 동력전달계의 비틀림 진동 현상에 대해 연구하였다. 이러한 연구들로 볼 때, 자동차 동력전달계에서 발생하는 진동은 이론과 실험을 통해 그 해석이 가능하며 설계에 매우 유용하게 이용되고 있음을 알 수 있다. 따라서, 본 연구는 4 실린더 4 싸이클 1.5 L 엔진을 장착한 경승용차의 실차 주행실험을 통해 가속 페달의 급조작에 따른 차체의 종진동 현상을 측정하고, 엔진-변속기-타이어-차체의 반환정계 4자유도 진동모델로 시뮬레이션을 수행하여 실차 주행실험의 결과치와 비교, 분석한 후 클러치 비틀림 특성을 비롯한 자동차 동력전달계의 각 설계인자들이 차체의 종진동에 어떠한 영향을 미치는가를 해석하고자 한다.be presented.LIFO, 우선 순위 방식등을 선택할 수 있도록 확장하였다. SIMPLE는 자료구조 및 프로그램이 공개되어 있으므로 프로그래머가 원하는 기능을 쉽게 추가할 수 있는 장점도 있다. 아울러 SMPLE에서 새로이 추가된 자료구조와 함수 및 설비제어 방식등을 활용하여 실제 중형급 시스템에 대한 시뮬레이션 구현과 시스템 분석의 예를 보인다._3$", chain segment, with the activation energy of carriers from the shallow trap with 0.4[eV], in he amorphous regions.의 증발산율은 우기의 기상자료를 이용하여 구한 결과 0.05 - 0.1

  • PDF

Modal Analysis of Automotive Body Model using Mode Synthesis Method (모드합성법을 사용한 차체모델의 모달해석)

  • 장경진;지태한;박영필
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1995.04a
    • /
    • pp.34-39
    • /
    • 1995
  • 최근 승용차의 급격한 수요증가와 더불어 차량의 승차감 개선에 많은 관심이 집중되면서, 저진동 저소음 차량에 대한 연구가 활발히 이루어지고 있다. 이러한 연구의 일부로서, 수치해석법 및 진동실험에 의하여 복잡한 전체 구조물을 해석할 경우, 계산기의 기억용량, 계산시간, 비용이 많이 들게 되고, 한번 해석을 행한 구조물을 부분적으로 변경할지라도 전체의 계산을 다시 수행해야만 한다. 그래서, 복잡한 전체 구조물을 몇 개의 부분구조물로 나누어, 분계의 특성에 맞게 각기 수치해석법이나 모달실험을 적용한 후, 다시 합성하는 방법이 제시되었는데, 이것이 부분구조합성법이다. 이 방법을 사용하면, 유한요소 모델링이 쉬운 분계와 실험이 쉬운 분계를 서로 구분하여 각기 해석한 후 합성함으로써, 각 분계의 특성에 맞는 효율적인 해석을 수행할 수가 있다. 지금까지의 연구를 살펴보면, 유한요소해석에 의한 모드합성법에서는 Hurty가 구속모드법을 제안한 이래, 불구속모드법, 주종계법 등 많은 연구가 있었으나, 실험모달해석을 병행할 경우에는 결합부에서의 회전자유도의 처리문제, 특성 행렬의 동정문제, 많은 절점으로부터 데이타를 얻어야 하는 등의 어려움이 있었다. 이러한 문제를 개선시켜서 Hermanski등은 회전자유도가 보간된 모드합성법(interpolated mode synthesis, IMS)을 연구하여, 적은 실험데이타만을 사용하면서 단순지지 보에 적용함으로써 타당성을 입증하였다. 한편, 차체는 복잡한 부분구조물들로 이루어져 있으므로, 본 연구에서는 유한요소모델링의 용이함, 실험의 간편성, 계산의 효율성등을 추구하며, 실험과 유한요소해석을 병행한 부분구조합성법을 차량의 BIW(body in white)에 적용하는 방법을 연구하게 되었다. 그 기본연구로서 실험과 유한요소해석을 병행하여 회전자유도를 보간하는 방법을 먼저 단순한 판구조물에 적용을 하고, 나아가 실제 BIW를 축소하여 자체 제작한 모형차에 적용시켜 보았다.물은 분계 A(16개의 사각요소)와 분계 B(8개의 사각요소)로 이루어져 있으며 두개의 스프링으로 결합되어 있다. 설계변수는 강성에 국한하였으며 결합부의 결합형태는 탄성결합과 강결합으로 하였다. 감도해석과 축소임피던스 합성법에 의해 구해진 고유진동수와 FRF를 상용 유한 요소 해석 패키지인 MSC/NASTRAN을 통하여 검증하여 이 연구의 타당성을 검토하였다.인풋기어에서의 회전수 변동을 측정하고, 이 실험 데이타를 기초로 하여 엔진 토크 및 변속기에서의 드래그 토크를 계산하여 엔진-변속기 인풋기어의 반한정계 2자유도 진동모델과 비틀림 특성을 가진 클러치 디스크의 프리댐퍼 영역에 대해 시뮬레이션을 수행하여 클러치 비틀림 기구의 설계인자인 비틀림 강성, 히스테리시스 토크에 따른 비틀림 진동 저감 효과를 연구하고자 한다.성을 확인하였다. 여기서는 실험실 수준의 평 판모델을 제작하고 실제 현장에서 이루어질 수 있는 진동제어 구조물에 대 한 동적실험 및 FRS를 수행하는 과정과 동일하게 따름으로써 실제 발생할 수 있는 오차나 error를 실험실내의 차원에서 파악하여 진동원을 있는 구조 물에 대한 진동제어기술을 보유하고자 한다. 이용한 해마의 부피측정은 해마경화증 환자의 진단에 있어 육안적인 MR 진단이 어려운 제한된 경우에만 실제적 도움을 줄 수 있는 보조적인 방법으로 생각된다.ofile whereas relaxivity at high field is not affected by τS. On the other hand, the change in τV does not affect low field profile but strongly in fluences on both inflection fie이 and the maximum relaxivity value. The results shows a fluences on both inflection field and the maximum relaxivity value. Th

  • PDF