• Title/Summary/Keyword: 요동

Search Result 297, Processing Time 0.033 seconds

Oxygen Transfer Rate from Liquid Free Surface in Reciprocally Shaking Vessel (왕복요동 교반조의 자유 표면에서의 산소흡수속도)

  • Koh, Seung-Tae
    • Korean Chemical Engineering Research
    • /
    • v.59 no.2
    • /
    • pp.276-280
    • /
    • 2021
  • The oxygen transfer rate at the liquid surface of the reciprocally shaking vessel was studied. The required power of the reciprocally shaking vessel was not proportional to the shaking frequency, unlike the rotational shaking vessel, and the liquid level suddenly fluctuated greatly at a certain frequency as the flow pattern in the vessel was a left and right wave flow different from that of the rotational shaking that has a rotational flow. The effect of the shaking frequency on the required power in the reciprocally shaking vessel was very complex, such as less power required than the rotational shaking vessel when the shaking frequency is more than 3 s-1, but the required power for the range of the generated rotational flow in the reciprocally shaking vessel could be correlated with the equation that was reported for the rotational shaking vessel. The kLa (mass transfer capacity coefficient) in the reciprocally shaking vessel also increased in a complex pattern because the required power for shaking was not consumed in a simple pattern, unlike kLa in the rotational shaking vessel, which increases linearly with increasing frequency. The kLa of the reciprocally shaking vessel was larger than the kLa of the rotational shaking vessel, and as the kLa value increased, the difference between them increased sharply. As a result, the oxygen transfer rate in the reciprocal motion was greater than that of the rotational motion, and could be correlated with the required power per unit volume.

보조 전극에 의한 기체방전 레이저의 출력안정화

  • 신동주;정영봉;이인원
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 1988.06a
    • /
    • pp.37-40
    • /
    • 1988
  • 보조전극을 사용하여 전기방전을 궤환 조절하여 연속출력 탄산가스 출력을 안정화하였다. 보조전극은 양극과 접지되어 있는 음극사이에서 음그근처에 설치하였으며 레이저 출력을 HgCdTe-detector로 측정하여 레이저 출력의 요동에 따라 보조전극에 인가되는 전압이 변화되도록 하였다. 보조전극을 사용하여 레이저 출력을 안정화시킨 결과 레이저 출력의 요동은 안정화하지 않았을때의 레이저출력 요동의 1/10 이하로 감소하였다.

  • PDF

Motion Sensing Algorithm for SAR Image Using Pre-Parametric Error Modeling (매개변수 사전 오차 모델링 기법을 이용한 SAR 요동측정 알고리즘)

  • Park, Woo Jung;Park, Yong-gonjong;Lee, Soojeong;Park, Chan Gook;Song, Jong-Hwa;Bae, Chang Sik
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.47 no.8
    • /
    • pp.566-573
    • /
    • 2019
  • In order to obtain high-quality images by motion compensation in the airborne synthetic aperture radar (SAR), accurate motion sensing in image acquisition section is necessary. Especially, reducing relative position error and discontinuity in motion sensing is important. To overcome the problem, we propose a pre-parametric error modeling (P-PEM) algorithm which is a real-time motion sensing algorithm for the airborne SAR in this paper. P-PEM is an extended version of parametric error modeling (PEM) method which is a motion sensing algorithm to mitigate the errors in the previous work. PEM estimates polynomial coefficients of INS error which can be assumed as a polynomial in the short term. Otherwise, P-PEM estimates polynomial coefficients in advance and uses at image acquisition section. Simulation results show that the P-PEM reduces relative position error and discontinuity effectively in real-time.

SAR Motion Compensation Using GPS/IMU (GPS/IMU를 이용한 SAR 영상의 요동 보상 기법에 대한 연구)

  • Kim, Dong-Hyun;Park, Sang-Hong;Kim, Kyung-Tae
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.1
    • /
    • pp.16-23
    • /
    • 2011
  • This paper suggests a motion compensation technique using GPS/IMU data in order to compensate for phase error caused by undesired motion of radar platform. An actual flight trajectory would be deviate from an ideal straight-constant trajectory with a constant velocity for SAR imaging, due to pitch, roll and yaw motion of aircraft caused by turbulence. This leads to blurred SAR images due to inter-pulse phase errors as well as along-track velocity errors. If the motion compensation is carried out to reduce those errors, SAR image quality can be significantly improved. Simulation results show that the motion compensation technique introduced in this paper is an effective tool to improve SAR image quality against severe motion of radar platform.

The Effect of the Packing Materials on the Pressure Fluctuations in Fluidized Bed (유동층 연소로에서 충전물이 압력 요동 특성에 미치는 영향)

  • Kim, Mi Young;Jo, Byung Yeol;Park, Sang Chan;Lee, Dong Kyu;Kim, Eui Sik
    • Applied Chemistry for Engineering
    • /
    • v.9 no.6
    • /
    • pp.852-856
    • /
    • 1998
  • Effects of packing materials on the pressure fluctuations in a fluidized bed have been analysed using statistical method to interpret fluidized bed behavior. The experiments were carried out in a fluidized bed of 6.7cm - ID, and the experimental variables were particle size and its distributions, fluidizing velocity, aspect ratio, and packing materials, etc. Screen packings are used as packing material, the properties of the pressure fluctuations in the fluidized bed were measured by a differential pressure transducer. The measured properties for the pressure fluctuations were the mean, the standard deviation, and the major frequency of the power spectral density functions, etc. The standard deviations of the pressure fluctuations have been slightly affected in the radial directions of fluidized bed, and almost constant in axial directions the height above 4.5cm of the distributor of fuidized bed without packing materials. The major frequency decreased with increaing packing size, whereas it showed maximum at 10% of packing materials. It has been found that the standard deviation of the pressure fluctuations can effectively explain the fluidized phenomena, and the packing materials severely affected the properties of the pressure fluctuations.

  • PDF

Characteristics of Minimum Fluidization Velocity and Pressure Fluctuations in Annular Fluidized Beds (Annular 유동층 반응기에서 최소유동화 속도 및 압력요동 특성)

  • Son, Sung-Mo;Kim, Uk-Yeong;Shin, Ik-Sang;Kang, Yong;Choi, Myung-Jae
    • Korean Chemical Engineering Research
    • /
    • v.46 no.4
    • /
    • pp.707-713
    • /
    • 2008
  • Characteristics of minimum fluidization velocity and pressure fluctuations were investigated in an annular fluidized bed whose diameter was 0.102 m and 2.0 m in height. Effects of gas velocity, particle size and bed temperature on the minimum fluidization velocity and pressure fluctuations were examined. The values of minimum fluidization velocity obtained by means of three different methods were very similar each other. The correlation dimension could be a quantitative parameter for expression the resultant complex behavior of gas and solid mixture in the annular fluidized bed. The value of correlation dimension increased with increasing gas velocity, fluidized particle size and temperature in the bed. The minimum fluidization velocity could be determined by means of correlation dimension of pressure fluctuations as well as pressure drop in the bed and standard deviation of pressure fluctuations. The minimum fluidization velocity increased with increasing particle size but decreased with increasing bed temperature in annular fluidized beds. The minimum fluidization velocity was well correlated in therms of correlation dimension as well as operating variables within experimented conditions of this study.

Clinical Implementation of a Virtual-Micro MLC for Smoothing MLC Field Edge (다엽콜리메이터에 의한 조사경계면에서의 요동현상을 완화시켜주는 가상미세다엽콜리메이터의 임상 적용)

  • Cho Byung-Chul;Park Hee-Chul;Bae Hoonsik
    • Progress in Medical Physics
    • /
    • v.15 no.3
    • /
    • pp.167-172
    • /
    • 2004
  • A Siemens HD-270 MLC$^{TM}$, a virtual-micro MLC, allows to the application of a smooth field edge method due to the finite leaf-width of MLC. This technique was implemented into a Pinnacle planning system in order to evaluate the dose distributions during the planning stage. The necessary dosimetric aspects, such as undulation and effective penumbra, were investigated with variations in the resolutions of a virtual-micro MLC and field edge angle. The positional accuracy of the couch movement was also assessed for clinical implementation. The overhead time for planning and treatment was confirmed as negligible.e.

  • PDF

Analysis of Pressure Fluctuation Properties during the Carbonization of Rice husk in a Fluidized Bed Reactor (유동층반응기에서 압력요동특성치를 이용한 왕겨 탄화반응 해석)

  • Han, Seung-Dong;Park, Ji-Heon;Peng, Meimei;Lee, Hwa-Yong;Cha, Wang-Seong;Jang, Hyun-Tae
    • Proceedings of the KAIS Fall Conference
    • /
    • 2010.05b
    • /
    • pp.1237-1240
    • /
    • 2010
  • 본 연구에서는 유동층반응기를 이용하여 왕겨의 탄화반응을 수행하였다. 탄화반응은 내경 40mm, 높이 1.8m의 유동층을 사용하였으며, 분산판은 다공성 스테인레스스틸을 사용하였다. 탄화반응은 질소를 이용하여 수행하였다. 왕겨 주입입자 크기는 직경 2.0mm, 0.715mm, 0.359mm, 0.194mm를 각각 사용하였으며, 유동층의 온도는 $400^{\circ}C$, $500^{\circ}C$, $600^{\circ}C$, $700^{\circ}C$에서 탄화특성을 측정하였다. 또한 유동층의 매질로는 직경 1.0mm의 Co-Mo-Fe/$Al_2O_3$ 촉매를 사용하였으며, 탄화물은 유동층상부에 설치된 사이크론에 의하여 포집분리되었다. 탄화시 유동층 내부의 현상을 압력요동을 이용하여 해석하였으며, 압력신호로부터 평균압력, 압력요동의 표준편차, 주진동수, power spectrum density function을 계산하여 층내현상을 해석하였다. 층내온도, 유동화속도, 공급 입자크기에 따른 층내현상을 압력요동특성치를 이용하여 해석할 수 있었다.

  • PDF

The Characteristics of Elutriation with Gaussian Particle Size Distributions in a gas-solid fluidized bed (기-고 유동층에서 Gaussian 분포 입자군의 표준편차에 따른 유출 특성)

  • Jang, Hyun-Tae;Cha, Wang-Seog
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.11
    • /
    • pp.3274-3279
    • /
    • 2009
  • The elutriation characteristics of particle size distribution were investigated in a gas-solid fluidized bed. Experiments were carried out with the mulit-sized particles of Gaussian distributions. The elutriation rate constant obtained from the experiment was correlated with the standard deviation of particle size and the dimensionless group of the velocity ratio. The standard deviation of pressure fluctuation, mean pressure, major frequency and power spectrum density function were calculated by pressure fluctuation properties. Size distribution of elutriated particles and pressure fluctuations were measured for the particle size distribution of particle system depended largrly on the size distribution. Characteristics of fluidization and elutriation were greatly influenced by the particle size distribution and these characteristics could be interpreted with pressure fluctuation properties.

Characteristics of Pressure-Drop Oscillations in a Boiling Channel (비등유로의 압력강하 요동특성)

  • Kim, B.J.;Shin, K.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.7 no.1
    • /
    • pp.132-141
    • /
    • 1995
  • Characteristics of pressure-drop oscillations(PDO) in a boiling channel were studied numerically and compared with experimental data. Effects of initial and boundary conditions on PDO were investigated in terms of oscillation period and amplitude. The period and amplitude of PDO increased with increasing of the compressible volume in the surge tank and the heat input. PDO occurred within the specific range of the fluid temperature, at which oscillation period and amplitude diminished rapidly with the increase of the fluid temperature. The increase of the loss coefficient in fluid supply line resulted in slightly longer oscillation period and larger amplitude. Numerical results showed good agreement with the experimental data.

  • PDF