• Title/Summary/Keyword: 외피단열

Search Result 51, Processing Time 0.022 seconds

Evaluation of Building Envelope Performance of a Dry Exterior Insulation System Using Truss Insulation Frame (트러스 단열 프레임을 이용한 건식 외단열 시스템의 외피 종합 성능 평가)

  • Song, Jin-Hee;Lee, Dong-Yun;Shin, Dong-Il;Jun, Hyun-Do;Park, Cheol-Yong;Kim, Sang-Kyun
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.35 no.6
    • /
    • pp.153-164
    • /
    • 2019
  • The presence of thermal bridges in a building envelope cause additional heat loss which increases the heating energy. Given that a higher building insulation performance is required in these cases, the heat loss via thermal bridges is a high proportion of the total heat energy consumption of a building. For the dry exterior insulation system that uses mullions and transoms to fix insulation and exterior materials such as stone and metal sheet, the occurrence of thermal bridges at mullions and transoms is one of the main reasons for heat loss. In this study, a dry exterior insulation system using the truss insulation frame (TIF) was proposed as an alternative to metal mullions. To evaluate the building envelope performance, structural, air-leakage, water-leakage, fire-resistance, thermal, and condensation risk tests were conducted. In addition, the annual energy consumption associated with heating and cooling was calculated, including the linear thermal transmittance of the thermal bridges. As a result, the dry exterior insulation system using TIF achieved the allowable value for all tests. It was also determined that the annual heating load of a building was reduced by 36.7 % when the TIF dry exterior insulation system was used, relative to the dry exterior insulation system using steel pipes without additional insulations.

A Study on the Current Status of Building Envelope in detached houses of near Local Cities - with Staff of Small-sized Architectural Design Firms in Gwangju and Jeonnam - (지방도시근교 단독주택의 외피구성 현황에 관한 연구 - 광주광역시/전남 소규모 건축설계사무소 실무자를 대상으로 -)

  • Park, Sung-Jin;Lee, Chang-Jae
    • KIEAE Journal
    • /
    • v.13 no.2
    • /
    • pp.53-60
    • /
    • 2013
  • This study examined the building envelope structure used in small housings near urban area which have not good energy source in relation to the application of passive design for energy saving of small-sized architectural design firms in local cities and aimed to provide the basic materials of future design direction of designers and housing owners by analyzing economy of a project in order to know the amount of energy saving and additional expenses depending on the building envelope pattern. As a result of comparing and examining the energy saving cost from the period of use compared to investment by the thickness of insulating materials based on building envelope pattern for energy saving, it was found that the thicker the insulating materials are, the more energy saving amount is. While the current bead-type insulating materials have short payback period due to low initial investment, extruded insulating materials show the difference of five years compared to bead-type insulation because of its high initial investment.

The Numerical Analysis on Insulation Performance with Respect to the Envelope Geometries and Array of Evacuated Powder Panel in Rigid Foam/Evacuated Powder Composite Panels (혼합초단열재에서 진공분말패널의 외피형상 및 패널배열에 따른 단열성능해석)

  • Hong, J.K.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.8 no.4
    • /
    • pp.497-509
    • /
    • 1996
  • Evacuated powder insulations have long been known to have better thermal performance than existing commercially available insulators, such as fiber glass and CFC-blown foam. To make a composite powder panel, a series of individually evacuated panels was encapsulated in a rigid closed cell foam matrix. The panels were encapsulated in a thin glass sheet barrier to preserve the vacuum. The thermal conductivity of the individual panel was found to be $0.0062W/m^{\circ}K$ by experiment and the polyurethane foam above had a thermal conductivity of $0.024W/m^{\circ}K$. In this study, numerical analysis using finite element method was carried out to investigate insulation performance of rigid foam/evacuated powder composite panel with respect to panel geometries such as panel pitch, panel aspect ratio and panel area ratio. Numerical analysis has indicated that more optimal vacuum panel geometries, much lower overall thermal conductivities can be achieved.

  • PDF

Impact of Reinforced Standard for Envelope Insulation on the Regional Heating and Cooling Energy Consumption (강화된 건물 외피 단열기준의 지역별 냉난방에너지 감소 효과)

  • Moon, Jin-Woo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.10
    • /
    • pp.646-655
    • /
    • 2011
  • This study aimed at quantifying the impact of the reinforced standard for envelope insulation on heating and cooling energy consumption in a Korean detached house as well as at identifying the effect of regionally subdivided standards. For them, a series of simulations for application of the reinforced standard on respective walls, roof, floor, windows, and all envelopes were computationally conducted for a prototypical detached residential building. In addition, the subdivided standards were applied to each regions-central and southern regions, and the Jeju island. Analysis revealed that heat transfer through envelopes was the most significant source of building heat gain and loss; the reinforced standard effectively reduced heating energy consumptions, especially in central region; and the subdivided standards did not presented a clear difference in the amount of energy consumption for the southern region and the Jeju island, thus, a further study is required to investigate the necessity of regional subdivisions.

Effects of the Moisture on the Overall Heat Transfer Through Heat Insulators Opaque Envelopes (불투명 외피의 열관류에서 단열재의 습도영향)

  • Lee, S.
    • Solar Energy
    • /
    • v.18 no.3
    • /
    • pp.63-69
    • /
    • 1998
  • The heat conduction and the water vapour diffusion flow through heat insulators between hygroscopical moist building materials were measured by means of the plate method. It was found that the heat transport increases with a moisture motion occuring in the temperature drop. On his basis of simplified assumptions, the increase in the thermal conductivity was calculated from the rate of diffusion flow per unit area, which generally resulted in values inferior to the measured values. The Increase in the heat transport due to water vapour diffusion measured at a large-scale wall specimen was inferior to the one measured by means of the plate method by using a comparable arrangement of layers. The overall heat transfer caused by moisture motion is not a characteristic value of the material, but a property of the whole wall structure

  • PDF

The Thermal Conduction Property of Structural Concrete using Insulation Performance Improvement Materials (단열성능향상 재료를 사용한 구조용 콘크리트의 열전도 특성)

  • Park, Young-Shin;Kang, Min-Gi;Kim, Jung-Ho;Ji, Suk-Won;Jeon, Hyun-Kyu
    • Journal of the Korea Institute of Building Construction
    • /
    • v.16 no.1
    • /
    • pp.9-15
    • /
    • 2016
  • The part of a building with the biggest energy loss is the exterior and many studies are actively conducted to reduce the energy loss on that part. However, most studies consider the window frames and insulation materials, but many studies do not discuss the concrete that takes more than 70% of the exterior. In order to minimize the energy loss of buildings, it is necessary to enhance the concrete's insulation performance and studies need to be conducted on this. Therefore, this study used a micro foam cell admixture, calcined diatomite powder, and lightweight aggregates as a part of a study to develop a type of concrete with improved insulation performance that has twice higher thermal conductivity compared to concrete. It particularly secured the porosity inside concrete to lower thermal conductivity. As a result of the experiment, the slump and air capacity showed fair results, but all mixtures containing micro foaming agent showed 14.3~35.1% lower mass per unit of volume compared to regular concrete. Compressive strength decreased slightly due to the materials used to improve the insulating performance, but it all satisfied this study's target strength(24MPa). Thermal conductivity was up to twice higher than that of regular concrete.

적외선 차단 기능이 있는 투명 전도성 다기능 스마트 필름

  • Seo, Mun-Seok;Jo, Jin-U
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.311.1-311.1
    • /
    • 2013
  • 건축물의 유리창을 통하여 유입되는 태양광을 조절하여 냉난방 부하를 절감하고자 사용하는 스마트 윈도우 필름(Electrochromic (EC), Polymer Dispersed Liquid Crystal (PDLC), Suspended Particle Display (SPD))의 방식이 있다. 이러한 스마트 윈도우 필름은 건물 외피에 적용할 때 여름철 태양으로부터 유입되는 열선 차폐만을 목적으로 유리를 완전히 불투명하게 가려버리는 것은 맑고 투명해야하는 창호의 기본적인 용도를 무시한 단편적 기술로서, 스마트 윈도우 필름을 작동하여 투명하게 할 경우 외부에서 열선이 유입되는 문제를 가지고 있다. 스마트 윈도우 필름을 만들 때 필수적으로 사용하는 전극필름으로 플렉서블 기판에 투명 전도막이 형성됨과 동시에 적외선만을 선택적으로 차단하는 기능을 가지는 필름을 제조하여 단열 성능 실험을 실시하였다. 아울러, 스마트 필름의 다양한 적용을 위한 발열 실험도 실시하였다.

  • PDF

Circulation Effect of the Transparent Insulated Opaque Envelopes (투명 단열외피를 통한 환기효과에 관한 연구)

  • Kim, S.H.;Kim, S.J.;Lee, S.
    • Solar Energy
    • /
    • v.20 no.4
    • /
    • pp.31-43
    • /
    • 2000
  • A model house with a "Ondol" heating working with solar energy and supplied by circulation air was investigated both experimentally and theoretically, A calculation method was developed for interpreting the measured values and for comparing several variants, This calculation method together with the measurement result is presented in the following. The gain in energy of the collector(Trombe wall type with TWD) measured on a particularly selected winter day with plenty of radiation amounted to approximately 31 % of the total solar radiation.

  • PDF

Assessment of material analysis for Non-flammable of cable (케이블 연소방지제의 재료에 대한 성능평가 기술)

  • Soh, Jin-Joong;Shim, Dae-Sub
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1472-1474
    • /
    • 2003
  • 연소방지재(난연테이프, 난연도료, 난연seal, 난연레진, 난연보드 등)란 지중 배전케이블, 접속재 및 통신케이블 등의 외피에 화재확산 방지를 위해 도포하여 사용하는 것으로서 화재 시 발포하거나 단열의 효과가 있어 케이블, 전선 등이 연소하는 것을 지연시킨다. 따라서 본 평가 기술에서는 수직불꽃시험, 산소지수, 저 염소시험, 발연농도, 케이블 허용전류저감률 등 주 재료시험에 대한 시험방법을 검토하고 시험에 적용하여 시험 시 문제점을 도출하여 시험방법을 정립하고자 한다.

  • PDF