• Title/Summary/Keyword: 외부하중

Search Result 552, Processing Time 0.036 seconds

현수교의 해석 및 설계

  • 현창헌
    • Computational Structural Engineering
    • /
    • v.5 no.1
    • /
    • pp.28-33
    • /
    • 1992
  • 현수교는 상당히 오래전부터 가설되어온 교량형식이기 때문에 구조해석이론도 일찍부터 개발되어 왔다. 그러나 외부 하중에 민감한 구조물이어서, 특히 동적인 하중에 대한 정확한 구조해석방법, 내풍설계방법 등은 아직도 연구가 계속되고 있다. 본 고에서는 현수교의 기본 형상을 소개하고 미력하나마 구조해석방법, 내풍설계방법, 설계시 고려해야 할 기본적인 사항들에 대하여 간략히 정리하여 보았다.

  • PDF

An Experimental Study on Mechanical Properties of SC Beam Structure under Temperature Load (강판콘크리트(SC : Steel Plate Concrete) 보의 온도하중 재하 시 역학적 특성에 관한 실험연구)

  • Lee, Kyung Jin;Ham, Kyung Won;Park, Dong Soo
    • Journal of Korean Society of Steel Construction
    • /
    • v.21 no.5
    • /
    • pp.443-450
    • /
    • 2009
  • This paper describes the experimental study that was conducted on the temperature characteristic and bending capacity of a steel-plate-reinforced concrete-wall module (SC module). The steel plate ratio and temperature loading parameters were tested, and the influence of these parameters on the moment-curvature relationship and on the bending strength of the SC module was investigated. The fundamental-structure characteristic result of every SC module that assumed practical use was investigated. In this study, the bending and flexural characteristics of SC structures were evaluated to verify the yielding and ultimate strength of the SC beam under thermal-loading conditions.

Buckling and Postbuckling Control of a Composite Beam with Embedded SMA Wire Actuators (형상기억합금 선 작동기를 삽입한 복합적층 보의 좌굴 및 좌굴후 제어)

  • Choi, S.;Lee, J.J.;Seo, D.C.;Choi, S.W.
    • Composites Research
    • /
    • v.12 no.3
    • /
    • pp.45-54
    • /
    • 1999
  • In this paper, an experimental study on the buckling and postbuckling control of a laminated composite beam with eccentrically embedded SMA wire actuators is performed. For the purpose of enhancing the critical buckling load, buckling control is investigated through the use of reactive moment associated with the shape recovery force of SMA wire actuators. To improve the control authority for the buckling and postbuckling control of the SMA-composite beam, closed-loop control is used. The buckling and postbuckling control behaviours are presented and discussed qualitatively and quantitatively on loaddeflection plots considering the stacking sequence of the laminate, slenderness ratio of the beam and activation conditions of the SMA wire actuators. By maintaining the desired deflection shape with the proper reactive moment, buckling control can be extended to the postbuckling of the SMA-composite beam subjected to an external load.

  • PDF

Relationship between the CMOD and the Load-Line Deflection of Concrete (콘크리트의 균열개구 변위와 하중방향 변위관계)

  • 김석기
    • Magazine of the Korea Concrete Institute
    • /
    • v.9 no.1
    • /
    • pp.183-194
    • /
    • 1997
  • Traditional displacmir~nt measurement included an extrancous and cvrntlc. portmn due to test setup and support crushing. The magnitudc of this erroneous deformation was found to be of the same order as the actual displacement, leading to inaccurate determinations of fracture parameters. To overcome this problem, the load-CMOD relationship is a more reliable parameter for determining the fracture characteristics because it is unaffected by the specimen setup and any support crushing. An important step towards the use of load-(:MOD concept as a key fracture parameter depends on relating the CMODto the traditional load-line deflection. This investigation found that there was an unique linear relationship between the CMOD and the load-line deflection. The exact numeric value of relationship between the CMOD and the deflection. that is, the slope ofthe line, is discovered to be a material property. The relationship finds a problem with the existing IZIL,EM recommendations for. measuring the fracture energy of concrete. A proposal to correct the problem is made.

An Experimental Study on the Strengthening Effect of RC Beam subjected to Repeated Loading during CFS Strengthening Process (탄소섬유 보강 중에 반복하중을 받은 RC보의 보강효과에 관한 실험적 연구)

  • Jang, Hee-Suk;Kim, Hee-Sung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.10 no.1
    • /
    • pp.183-189
    • /
    • 2006
  • When RC structures are repaired or strengthened using FRP, it is required to cure for some Period under certain air temperature and then it is hopeful to avoid detrimental action caused by external vibration sources during that period. Therefore, an effect of repeated loading during Carbon Fiber Sheet(CFS) strengthening Process on the strengthening efficiency is studied through an experiment for a number of RC beams. Experimental results showed that the curing time of 24 hours without any repeated loading after CFS attachment were recommended for 1 ply strengthening, and 12 hours for 2 plies strengthening.

Seismic Behaviour of Exterior Joints in Post-Tensioned Flat Plate Systems (포스트 텐션 플랫 플레이트 외부 접합부의 내진 거동)

  • Han, Sang-Whan;Kee, Seong-Hoon;Kang, Tomas H.K.;Cho, Jong;Lee, Li-Hyung
    • Journal of the Korea Concrete Institute
    • /
    • v.18 no.5 s.95
    • /
    • pp.595-602
    • /
    • 2006
  • An experimental study was conducted to investigate seismic behaviour of post-tensioned(PT) exterior slab-column connections used for the purpose to resist gravity loads only. For these, 2/3-scale, two PT post-tensioned exterior connections with two different tendon arrangement patterns and one conventional reinforced concrete(RC) exterior connection was tested under quasi-static, uni-directional reversed cyclic loading. During the lateral testing, gravity forces transferred to the column were kept constant to closely simulate a moment to shear ratio of a real building. One of the objectives of this study was to assess the necessity and/or the quantity of bottom bonded reinforcement needed to resist moment reversal which would occur under significant inelastic deformations of the adjacent lateral force resisting systems. The ACI 318 and 352 provisions for structural integrity were applied to provide the bottom reinforcement passing through the column for the specimens. Prior test results were also collected to conduct comparative studies for some design parameters such as the tendon arrangement pattern, the effect of post-tensioning forces and the use of bottom bonded reinforcement. Consequently, the impact of tendon arrangement on the seismic performance of the PT connection, that is lateral drift capacity and ductility, dissipated energy and failure mechanism, was considerable. Moreover, test results showed that the amount of bottom reinforcement specified by ACI 352. 1R-89 was sufficient for resisting positive moments arising from moment reversal under reversed cyclic loads. Shear strength of the tested specimens was more accurately predicted by the shear strength equation(ACI 318) considering the average compressive stress over the concrete($f_{pc}$) due to post-tensioning forces than that without considering $f_{pc}$.

비선형 균열배관 해석 방법을 이용한 배관 안전성 평가

  • 김태순;박치용;김진원;박재학
    • Proceedings of the Korean Institute of Industrial Safety Conference
    • /
    • 2001.11a
    • /
    • pp.169-174
    • /
    • 2001
  • 원자력발전소 배관계통에 존재하는 균열을 해석하는 방법으로, 이제까지는 균열을 고려하지 않은 상태에서 지진하중을 고려한 탄성 배관해석을 수행하여, 배관에 작용하는 하중을 구한 후, 다음 단계에서 파괴해석 방법으로 균열을 가정한 탄소성 균열해석을 수행하는 2단계의 해석을 통해 균열안정성을 평가해 왔다. 이러한 방법은 전체 배관의 거동과 배관 내에 존재하는 균열의 거동을 서로 독립적인 것으로 고려하고 있으며 재료물성치로는 설계값을 사용하는 등의 보수적인 가정들을 포함하고 있어 배관에 작용하는 하중 또는 응력을 과도하게 계산하는 결과를 초래하고 있다 특히, 지진하중과 같은 반복적인 외부 동적하중이 작용하는 경우, 배관에 국부적인 소성변형이 발생함에도 이를 단지 탄성거동으로 간주하게 되는 것이다. 이러한 몇몇 보수적 가정들을 포함하고 있는 기존의 해석방법은 지나친 보수성을 가질 뿐만 아니라, 균열에 의한 실제 배관의 파단하중과 계산에 의한 파단하중의 비교로서 배관의 안전여유도를 예측하는 방법으로는 적절하지 못하다.(중략)

  • PDF

항공기에 장착된 POD 연결부의 구조 신뢰성 평가

  • 윤혁중;신규인;박상윤;박재학;김도형;주진원;주영식;전승문
    • Proceedings of the Korean Institute of Industrial Safety Conference
    • /
    • 2003.10a
    • /
    • pp.101-106
    • /
    • 2003
  • 항공기 외부 장착물인 POD는 전자전 방해장치(ECM, electronic counter measures)로서 전자방해 장비 및 부분 부품인 전ㆍ후방 러그(lug)와 외부 케이스로 이루어져 있다. POD는 항공기 외부 동체 하단부 및 파일런(pylon)에 장착되어 작동하므로 항공기의 운용중 이륙부터 착륙간의 기동에 의한 피로하중을 주로 받게 되므로 POD 부품들에 대한 구조 건전성 확보하기 위해서는 MIL-STD-1530의 요구에 따라 내구성(durability) 및 손상허용설계(damage tolerance design) 의 평가가 요구되고 있다.(중략)

  • PDF

Numerical Study on Thrust Characteristics of an External Pintle Thruster (노즐 목 외부형 핀틀추력기의 추력특성에 대한 수치해석 연구)

  • Choi, Junsub;Kim, Dongyeon;Huh, Hwanil
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.43 no.12
    • /
    • pp.1071-1078
    • /
    • 2015
  • Numerical computations were performed to investigate the effects of pintle stroke, altitude, and bore on the performance of an external pintle thruster. Results show that under-expansion flow occurs always, independent of pintle stroke. An external pintle thruster shows good performance in that it is capable of good amount of thrust control, while aerodynamic loads are increased due to shock waves on the pintle support. When altitude is increased to 20 km, the nozzle exit velocity, Mach number, thrust as well as aerodynamic loads are increased. Bore increases aerodynamic load 5.9%, and therefore pintle shape without bore is preferred for lower aerodynamic load of a pintle in order to actuate the pintle.

A study on Development of Methods to Rehabilitate the Damaged Prestressed Concrete beam Using Glass Fiber (유리섬유를 이용한 손상된 프리스트레스트 콘크리트 보의 보강공법 개발연구)

  • Kang, Won-Ho;Han, Man-Yop;Lee, Taek-Sung;Rhu, Young-Min
    • Magazine of the Korea Concrete Institute
    • /
    • v.11 no.2
    • /
    • pp.167-175
    • /
    • 1999
  • Many composite girder bridges have been constructed for about thirty five years. Nowadays they are aged or deteriorated because of the increase in traffic and vehicle loads. In this study, the effect of strengthening with glass fiber sheet is investigated to estimate the possibility for applying to damaged prestressed concrete bridges. One normal and eight cracked specimens which had been preloaded were tested. The cracked specimens were strengthened with either external prestressing or bonding glass fiber sheet, or using both methods. The results showed that the maximum loads are almost same for both methods. So it seems that the strengthening with glass fiber sheet can be used for strengthening damaged prestressed concrete girders. It is important that proper devices should be selected to prevent glass fiber sheet from premature bonding failure below its maximum load, which is similar to end anchorage problem in external prestressing method. It is proved that the devices proposed in this paper have sufficient anchoring capability to increase load carrying capacity.