• Title/Summary/Keyword: 외부접합형

Search Result 50, Processing Time 0.027 seconds

Improvement and Evaluation of Seismic Performance of Reinforced Concrete Exterior Beam-Column Joints using Embedded CFRP Rods and CFRP Sheets (매입형 CFRP Rod와 CFRP시트를 활용한 RC 외부 보-기둥 접합부의 내진성능 평가 및 개선)

  • Ha, Gee-Joo;Kang, Hyun-Wook
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.3
    • /
    • pp.40-48
    • /
    • 2014
  • In this study, experimental research was carried out to evaluate and improve the seismic performance of reinforced concrete beam-column joint regions using strengthening materials (embedded CFRP rod and CFRP sheet) in existing reinforced concrete building. Therefore it was constructed and tested six specimens retrofitting the beam-column joint regions using such retrofitting materials. Specimens, designed by retrofitting the beam-column joint regions of existing reinforced concrete building, were showed the stable failure mode and increase of load-carrying capacity due to the effect of crack control at the times of initial loading and confinement of retrofitting materials during testing. Specimens RBCJ-SRC2, designed by the retrofitting of CFRP Rod and CFRP Sheet in reinforecd beam-column joint regions were increased its maximum load carrying capacity by 1.97 times and its energy dissipation capacity by 2.08 times in comparison with standard specimen RBCJ for a displacement ductility of 4 and 7. Also, specimens RBCJ-SRC2 were increased its maximum load carrying capacity by 1.09~1.11 times in comparison with specimen RBCJ-SR series. And Specimens RBCJ-CS, RBCJ-SR series, RBCJ-SRC2 were increased its energy dissipation capacity by 1.10~2.30 times in comparison with standard specimen RBCJ for a displacement ductility of 5, 6.

Behavior of Concrete-Filled Tube Column to H-Beam Connections with External Stiffeners and Reinforcing Bar (외부스티프너와 철근으로 보강한 CFT 기둥-H형강 보 접합부의 거동)

  • Kang, Chang-Hoon;Shin, Kyung-Jae;Oh, Young-Suk;Moon, Tae-Sup
    • Journal of Korean Society of Steel Construction
    • /
    • v.12 no.1 s.44
    • /
    • pp.55-63
    • /
    • 2000
  • This paper is a study on the behavior of Concrete-Filled Square Tubular(CFST) column to H-beam connections reinforced with external stiffeners and reinforcing bar. The cyclic loading tests of 5 test specimens were carried out. The main Parameters are as follows; 1)the length of the stiffener: 200mm, 250mm, 2)the diameter of reinforcing bar: HD16, 19. The results of the researches demonstrate that the increase of the stiffener length was more effective than the increase of the area of reinforcing bar in the point of both strength and stiffness. By reinforcing external stiffeners, stable hysteretic behavior was shown and plastic hinge was formed on the beam flange. Cold-formed tube sections should be used carefully to avoid the welding fracture at the round corners of section, and the proposed welding methods are suitable for this connections.

  • PDF

A Study on Unbalanced Moment of Flat Plate Exterior Connections (플랫 플레이트 외부접합부의 불균형모멘트에 관한연구)

  • Choi, Hyun-Ki;Beck, Seong-Woo;Back, Young-Soo;Jin, Eon-Sik;Choi, Chang-Sik
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.1-4
    • /
    • 2008
  • Flat plate slab has been widely used in high rise building for its remarkable advantages. However, Flat plate structures under lateral load are susceptible to punching shear of the slab-column connection. Exterior slab-column connections has an unsymmetrical critical section for eccentric shear of which perimeter is less than that of interior connection, and hence, around the connection, unbalanced moment and eccentric shear are developed by both gravity load and lateral loads. Therefore, exterior connections is susceptible to punching shear failure. For that reason, this study compare ACI 318-05 to CEB-FIP MC 90 that is based on experiment results and existing data of flat plate exterior connections. This study shows that compared to CEB-FIP MC 90 is more exact about eccentric shear stress, unbalanced moment and Both of all are not suitable in large column aspect ratio. Considering gravity shear ratio, These are suitable but design condition only consider gravity shear ratio. So these should be considered differences from change of design condition

  • PDF

The behavior of boron segregation according to heat input in the weld CGHAZ of low alloyed steel (용접 입열량에 따른 저합금강 용접부 CGHAZ의 보론 편석거동 분석)

  • Kim, Sang-Hoon;Lee, Jong-Ho;Lee, Kyung-Sub;Hwang, Byoung-Chul;Lee, Chang-Gil;Lee, Chang-Hee
    • Proceedings of the KWS Conference
    • /
    • 2009.11a
    • /
    • pp.60-60
    • /
    • 2009
  • 본 연구는 보론이 첨가된 저합금강 용접 열영향부에서의 보론 편석 거동 연구를 위해 보론이 10ppm 첨가된 저합금강을 이용하여 다양한 용접 입열량 및 외부 응력에 따른 용접부 CGHAZ의 보론 편석거동을 분석하였다. 이를 위해 Gleeble 시스템을 이용하여 다양한 입열량에 따른 CGHAZ를 열 및 열-응력 사이클을 통하여 재현하였다. 재현된 시편의 미세조직은 OM을 통하여 분석하고, 보론의 편석거동을 SIMS와 PTA 분석법을 통하여 분석하였다. 그 결과 입열량에 따른 보론의 편석 거동은 최초 입열량이 증가함에 따라 보론의 편석이 증가하다가 다시 감소하였는데 이는 비평형 편석 후 고온에서 유지시간이 길어짐에 따라 back diffusion 발생에 따른 영향으로 판단된다. 또한 외부 응력에 의한 보론 편석 거동 분석 결과, 용접 열 사이클 중 작용하는 외부 응력에 의해 결정립계 편석 감소하였는데 이는 외부 응력에 의한 오스테나이트 결정립 크기 감소에 따른 결정립계 증가의 영향으로 판단된다.

  • PDF

Evaluation of Structural Behavior of Reinforced Concrete Exterior Beam-Column Joints with High-Strength Concrete (고강도 콘크리트를 사용한 철근콘크리트 외부 보-기둥 접합부의 거동 평가)

  • Lee, Bum-Sik;Kim, Kyung-Duk;Kim, Sang-Woo;Kim, Kil-Hee;Lee, Jung-Yoon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.6
    • /
    • pp.72-81
    • /
    • 2014
  • This paper reports the test results of reinforced concrete exterior beam-column joints with high-strength concrete. The main parameters of eight specimens were joint failure modes, the compressive strength of concrete, and the head shapes of steel bars. All specimens were designed according to ACI 352R-02 design recommendations. Two types of failure modes were considered; J-failure and BJ-failure. The longitudinal steel bars were anchored by 90 degree standard hooks or headed reinforcement. Experimental results indicated that the current ACI design recommendation limited by the compressive strength of concrete somewhat underestimated the strength of beam-column joints with high-strength concrete. In the specimens showed joint shear failure, the strength of beam-column joints with headed bars was approximately 10 percent higher than that of joints with 90 degree standard hooks.

Experimental Study on the Behavior of Hybrid Beam-Column Joints Consisted of Reinforced Concrete Column and Steel Beam (철근콘크리트 기둥 및 철골보로 구성된 복합구조의 접합분 거동에 관한 실험적 연구)

  • Choi, Keun-Do;You, Young-Chan;Lee, Li-Hyung
    • Journal of the Korea Concrete Institute
    • /
    • v.15 no.2
    • /
    • pp.297-304
    • /
    • 2003
  • This paper presents the test results of RCS(Reinforced Concrete Steel) beam-column joint with various types of transverse reinforcements such as small-column-type transverse reinforcements, four-piece ㄱ-shape assembled hoops and four-piece ㄱ-shape welded hoops. Five interior beam-column joint specimens were tested to examine the seismic performance and the shear strengths. From the test results, it was found that all the specimens sustained their strength at large levels of story drift(${\theta}$=0.035) without significant loss of strength and stiffness. Therefore it was concluded that the seismic performance and shear strength of the proposed RCS joint are at least the same as those of the specimen with conventional reinforcing details. Also, the contribution of the outer panel to the shear strength of the joint should be evaluated by the compression strut mechanism rather than compression field mechanism.

Tunneling Magnetoresistance of a Ramp-edge Type Junction With Si3N4 Barrier (Si3N4장벽층을 이용한 경사형 모서리 접합의 터널링 자기저항 특성)

  • Kim, Young-Ii;Hwang, Do-Guwn;Lee, Sang-Suk
    • Journal of the Korean Magnetics Society
    • /
    • v.12 no.6
    • /
    • pp.201-205
    • /
    • 2002
  • The tunneling magnetoresistance (TMR) of a ramp-edge type junction has been studied. The samples with a structure of NiO(60)/Co(10)/NiO(60)/Si$_3$N$_4$(2-6)/NiFe(10) (nm) were prepared by the sputtering and etched by the electron cyclotron (ECR) argon ion milling. Nonlinear I-V characteristics was obtained from a ramp-type tunneling junctions having the dominant difference between zero and +90 Oe perpendicular to the junction edge line. The voltage dependence of TMR was stable up to a bias volt of $\pm$10 V with a TMR ratio of about -10%, which may be very peculiar magnetic tunneling properties with asymmetric tunneling process between wedge Co pinned layer and NiFe free layer.

The Measurement of Junction Depth by Scanning Electron Microscopy (전자현미경에 의한 확산 깊이 측정)

  • 허창우
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2004.05b
    • /
    • pp.623-626
    • /
    • 2004
  • The purpose of this paper is to determinate and to confirm p-n junction depth with nondestructive method by using electron beam. By measuring the critical short circuit current on the p-n junction which induced by electron beam and calculating generation range, the diffusion depth can be obtained. It ran be seen that values destructively measured by constant angle lapping and nondestructively by this study almost concur. As this result, it is purposed that diffusion depth of p-n junction can be easily measured by non-destruction. And this nondestructive method ran be recommended highly to the industrial analysis.

  • PDF

A New Miniaturized Electron-Beam deflector for Microcolumn (Microcolumn 을 위한 새로운 개념의 초소형 전자빔 deflector)

  • Han, Chang-Ho;Kim, Hak;Chun, Kuk-Jin
    • Proceedings of the IEEK Conference
    • /
    • 2003.07b
    • /
    • pp.1037-1040
    • /
    • 2003
  • 본 논문에서는 microcolumn 을 위한 초소형 전자빔 deflector 의 제작방법과 microcolumn array 에서 deflector 의 외부 패드를 최소화 할 수 있는 새로운 배선방법을 기술하였다. 배선의 통로 및 절연체 역할을 하는 Pyrex glass 의 양쪽에 각각 실리콘 웨이퍼의 양극접합 및 deep reactive ion etching(DRIE)과 금속 전기 도금을 이용하여 다층배선을 하였다. 이 배선방법을 이용하면 microcolumn array 가 수백개가 되더라도 deflector 의 외부 패드는 항상 8개를 유지할 수 있다.

  • PDF

A Study on Strengthening of Steel Girder Bridge using Multi-Stepwise Thermal Prestressing Method (다단계 온도프리스트레싱을 이용한 강거더교의 보강에 관한 연구)

  • Kim, Sang Hyo;Kim, Jun Hwan;Ahn, Jin Hee
    • Journal of Korean Society of Steel Construction
    • /
    • v.18 no.6
    • /
    • pp.717-726
    • /
    • 2006
  • Traditional external post-tensioning method using either steel bars or tendons is commonly used as a retrofitting method for steel composite bridges. However, the method has some disadvantages such as stress concentration at anchorages and inefficient load-carrying capability of live loads. Multi-stepwise prestressing method using thermal expanded coverplate is a newly proposed prestressing method, which was originally developed for prestressing steel structures. A new retrofitting method for steel girder bridges founded on a simple concept of thermal expansion and contraction of cover plate, the method is a hybrid of and combines the advantages of external post-tensioning and thermal prestressing. In this paper, basic concepts of the method are presented and an illustrative experiment is introduced. From actual experimental data, the thermal prestressing effect was substantiated and the FEM approach for its analysis was verified. The retrofitting effects ofa single-span bridge were analyzed and the feasibility of the developed method was examined.