• Title/Summary/Keyword: 외부순환도로

Search Result 4, Processing Time 0.02 seconds

Analysis of the Construction Plan and Enforcement Condition of the Port Circular Highway for Cargo Transportation of the Pusan Port (부산항 물동량 처리를 위한 광역배후수송도로의 건설계획과 시행실태 분석)

    • Journal of Korean Port Research
    • /
    • v.13 no.2
    • /
    • pp.313-322
    • /
    • 1999
  • Pusan the principal port of South Korea, has opened its door since 1876. Currently, the four-stage port construction project is under way to handle ever-growing marine transportation volume. While the port unloading capabilities are increasing the infrastructure to deal with all the transportation volume failed to catch up with them. Accordingly the city had to suffer from worst traffic congestion on due to the increasing container traffic volume causing logistical costs to rise. This study was designed to inspect the enforcement of infrastructure construction plan and suggest systematical and effective ways to improve the plan. The study focused on :\circled1The decision-making procedure, \circled2Financial resource for the plan, \circled3Effectiveness of the project enforcement, and \circled4Who will be in charge of the project. As a result from the study, these followings were suggested to improve the plan. First, Pusan Port Infrastructure consisting of (Inter-city Free way, Belt Highway and Outer Highway) should be immediately legally-regulation project. Second, the method to finance the project should be deter-mined and investment consultation among the central government the city government and private sector should be also made. Measures to make the central government budget allocation for the project mandatory should be discussed. Third, Effectiveness of the project can be doubled by gradually or partialyl opening the routes based on long-term or short-term operating plans. Fourth, The organizer of the project should be appointed, or a special task-force team in charge of the plan can be formed.

  • PDF

Analyze of Thermal Resistivity Characteristics for Recycled Aggregates (순환골재의 열저항특성 분석)

  • Kim, Kyoungyul;Hong, Sungyun;Lee, Daesoo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.164.2-164.2
    • /
    • 2010
  • KEPCO에서는 발전소로부터 생산되는 전력을 각 가정에 공급하기 위하여 전력선을 설치하고 있다. 이 전력선은 지상과 지중에 동시에 설치되고 있으며, 지상에 위치한 전력선을 가공선이라 한다. 지중에 설치된 전력선을 지중선이라 하며, 지중선을 설치하기 위한 공사를 지중화공사라 한다. 전력선은 전력이 통전될 때 일정한 온도 이상의 열이 발생하게 되며 이 열이 신속하게 외부로 빠져나가야지만 전력수송효율이 떨어지지 않게 된다. 지중화공사는 대부분 도로를 재굴착하여 설치하게 되며, 전력선을 설치한 후 주변 되메움재로는 모래를 이용하고 있다.하지만 최근 들어 모래의 수급이 딸리고, 가격이 높아지고 있는 관계로 이의 대체재료가 필요한 실정이다. 이에 본 연구에서는 전력선 되메움재인 모래의 대체재료로 건설폐기물의 일종이었던 순환골재를 이용하기 위하여 열저항특성을 분석하였다. 이미 순환골재는 2005년부터 공공 공사에 의무적으로 사용하도록 규정이 되어 있어 도로 또는 콘크리트 골재로 사용하고 있다. 순환골재를 전력선 되메움재로 사용하기 위해서는 열저항온도(thermal resistivity)가 $120^{\circ}C$-cm/W 이하가 되어야만 전력선 효율이 떨어지지 않기 때문에 이를 만족하는 것이 매우 중요하다. 이를 위해 QTM-500 장비를 이용하여 순환골재의 열저항 특성실험을 시행하였다. 실험의 원활한 수행을 위하여 순환골재의 입도는 5.0mm 이하로 제한하였으며, 인자로는 다짐도와 함수비를 중요한 인자로 선택하였다. 분석결과, 다짐도 및 함수비는 순환골재의 열저항온도에 영향을 미치는 주인자로 나타났으며, 일부 교호작용도 존재하는 것으로 나타났다. 향후 실험결과를 바탕으로 현장 실증실험을 수행할 예정이며, 본 연구결과는 KEPCO의 순환골재 이용기준수립에 활용할 예정이다.

  • PDF

A Numerical Study on the Effects of Buildings and Topography on the Spatial Distributions of Air Pollutants in a Building-Congested District (건물 밀집 지역에서 대기오염물질 분포에 미치는 건물과 지형의 영향에 관한 수치 연구)

  • Kang, Geon;Kim, Jae-Jin;Lee, Jae-Bum
    • Korean Journal of Remote Sensing
    • /
    • v.36 no.2_1
    • /
    • pp.139-153
    • /
    • 2020
  • Using a computationalfluid dynamics(CFD) model, thisstudy evaluated the representativeness of an air quality monitoring system (AQMS) in an urban area and presented a methodology to determine the suitable AQMS locations for specific purposes. For this, we selected a 1.6 km × 1.6 km area around the Eunpyeong-gu AQMS (AQMS 111181) as a target area. We conducted simulationsfor two emission scenarios (scenario one: air pollutants transported from inflow boundaries, scenario two: air pollutants emitted from roads). Urban airflows were markedly influenced by mountainous terrain located in the northeast and southeast of the target area, and complicated airflow patterns occurred around the buildings. The distributions of air pollutants were dependent on the terrain (mountain) in scenario one, but the road location and building height in scenario 2. We evaluated whether the AQMS could represent the air quality in the target area based on the simulations for two scenarios. The concentrations simulated at the AQMS were similar in magnitude to the layer mean concentrations, which indicated good representativeness for the air quality in the target area. We also suggested which locations were suitable for different measurement purposes (hot spots, clean zones, average zones, shelter zones, equi-background zones).

Comparison of Heat Exchanging Performances Depending on Different Heat Exchanging Pipe Arrangement (열회수장치의 열교환 파이프형식별 열교환 성능 비교)

  • 서원명;윤용철;강종국;김정섭
    • Proceedings of the Korean Society for Bio-Environment Control Conference
    • /
    • 2001.04b
    • /
    • pp.100-102
    • /
    • 2001
  • 본 연구에서는 온실의 난방에 사용되는 열풍식 난방기 등의 배기 연통에 부착하여 배출되는 가스로부터 열을 회수할 수 있는 장치를 개발함에 있어서 연통과 열회수 장치간의 열 교환 성능을 3가지 상이하게 설계된 열 교환 장치(Fig. 1 참조)에 대하여 실험적으로 비교 분석하였다. Fig. 1-(a)는 열 교회수기 개발을 위해 기존에 사용한 장치로서 회수용 공기의 흐름방향이 배기 연통과 직각을 이룬 형식이며, Fig. 1-(b) 및 (c)는 열 회수 성능 개선을 위해 새로 설계된 형식으로서 각각 열 교환 파이프의 배치형식이 상이하나 회수용 공기의 흐름방향이 180도로 굴곡되는 U-자형 흐름이 이루어지도록 하였다. 실험에 사용된 공기 순환 펜의 용량은 AB-형의 경우에는 최대 25㎥/min이고, C-형 및 D-형의 경우는 공히 최대 42㎥/min으로서 송풍전압 조절장치를 이용하여 풍량을 연속적으로 조절할 수 있도록 하였다. U-자형 흐름형식인 C-형 및 D-형의 경우 흐름 방향의 굴곡으로 인한 마찰저항이 있을 것으로 예상은 했으나 당초 예상했던 것에 비해 마찰 저항이 지나치게 큰 것으로 밝혀졌다. 비록 설계된 열교환 튜브의 배열형식별 열 교환기의 외부 모양이 달라 회수기의 표면을 통한 대류 열 교환이 다소 차이를 보일 것으로 예상되지만 본 연구에서는 열 회수장치에 내장된 열 교환 튜브부분만을 통한 열 회수율을 중심으로 형식간의 성능을 비교하였다. 실험을 통하여 측정된 자료중 대표적인 예는 Fig-2와 같으며, 측정자료를 기준으로 분석된 열회수 성능에 대한 설계형식별 비교 결과는 Table-1과 같으며, 분석된 결과를 요약하면 다음과 같다: 1. AB-형 열회수시스템의 경우, 초기 투자비용과 현재의 농용 전력요금 하에서 에너지 절감규모를 비교하면, 대체로 1년을 전후하여 투자에 대한 보상이 충분히 가능할 것으로 판단된다. 2. C-형 및 D-형 열회수시스템의 경우, 열 회수용 공기의 흐름방향이 동일 공간내에서 180도 굴절됨으로서 저항이 크게 발생되어 송풍 펜의 전압 증가에 따른 유속증가가 미미하였으며, 굴절형의 열교환장치는 비록 열교환면적은 직선형과 유사하더라도 송풍 펜의 공기저항이 커져서 결국 열 회수성능이 기대했던 것만큼 크게 개선되지는 못했다. 3. 송풍펜의 용량은 AB-형에 사용된 용량인 25㎥/min 전후가 적절할 것으로 판단되며, 적정 송풍 펜용량 하에서 열 회수성능은 굴절형이 직선형보다 효과적인 것으로 나타났다. 다만, 곡선형은 물론 직선형에서도 열교환 튜브의 배치밀도, 튜브 길이 및 두께 등의 변화에 따른 최적화 연구가 수반되어야 할 것으로 판단된다.

  • PDF