• Title/Summary/Keyword: 외부부하

Search Result 295, Processing Time 0.021 seconds

A 2012 size multilayer LTCC BPF for 2.4 GHz band (2.4 GHz 대역 2012 사이즈 적층 LTCC 대역통과 필터의 설계 및 제작)

  • 이영신;송희석;박종철
    • Proceedings of the International Microelectronics And Packaging Society Conference
    • /
    • 2002.11a
    • /
    • pp.91-95
    • /
    • 2002
  • A very small size BPF is realized using LTCC Multilayer technology. A λ/4 resonator with shunt-to-ground loaded capacitor is used to shorten resonator length and achieve higher qualityfactor. Also this resonator enable BPF to improve out-of-band rejection. Coupling coefficients between coupled stripline resonators and external qualityfactor of a resonator are derived and apply to the filter design. The measured results show a good agreement with the simulation.

  • PDF

Cache Reliability Enhancing Method for Recursive DNS (Recursive DNS의 캐쉬 정보 신뢰성 향상 기법)

  • Ju, Yong-Wan;Lee, Eung-Jae;Nam, Kwang-Woo
    • The KIPS Transactions:PartC
    • /
    • v.15C no.4
    • /
    • pp.227-238
    • /
    • 2008
  • As the internet users rise up rapidly, DNS information forgery can cause severe socio-economic damages. However, most studies on DNS information security reached the breaking point in applying to actual circumstances because of the limit of existing DNS system version, the increasement of management burden and etc. The paper proposes the real-time method for detecting cache poisoning of DNS system independent of analysing the DNS forgery types in the current DNS service environment. It also proposes the method of enhancing the reliability for the cache information of Recursive DNS system by post-verifying the cache information of the DNS system.

A Fuel Cell System with Z-Source Inverter and Ultracapacitors (Z-소스 인버터와 울트라커패시터를 이용한 연료전지 시스템)

  • Kim, Yoon-Ho;Lee, Uk-Young;Kim, Soo-Hong
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.12 no.4
    • /
    • pp.285-290
    • /
    • 2007
  • When input parameters like gas volume or load of the fuel cell system is changed, the fuel cell system can generate transient voltage disturbances. In this paper, a fuel cell system with Z-source inverter and ultracapacitors for voltage disturbance compensation is proposed. The structure of Z-source inverter is simple. It has unique features that can boost/buck input voltage with a DC/DC converter using only a modified switching pattern. The characteristics of the proposed topologies for the fuel cell system with Z-source inverter and ultracapacitors are analyzed using simulation, and verified by experiments. The simulation and experimental results show that the proposed system is capable of operating with stable response to the system transient and voltage disturbances.

An Analysis to security on SmartMobile based u-Healthcare system using by HIGHT (스마트모바일 기반의 u-Health시스템에서 HIGHT를 이용한 보안성 분석)

  • Lee, Jae-Pil;Kim, Young-Hyuk;Lim, Il-Kown;Lee, Jae-Gwang;Lee, Jae-Kwang
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2012.04a
    • /
    • pp.738-741
    • /
    • 2012
  • 한국정보통신기술협회(TTA)에서 표준 제안한 WBAN(Wireless Body Area Network)은 인체 내부 통신(in-body or implant)과, 인체 외부 통신(on-body)통신으로 구분하고 있다. 생체측정 정보 중 체온, 호흡, 맥박, 운동량, 심박의 부분적인 데이터 수집을 바탕으로 환자의 생체정보 데이터를 수합 후 데이터 프레임구조로 변환하여 스마트모바일 애플리케이션 환경에서 사용자가 모바일기기 화면에 정보를 표시 할 수 있다. 이렇게 표시된 정보들은 환자의 상태를 실시간으로 자신의 스마트모바일을 이용하여 확인할 수 있으며, 이러한 정보를 보호하고 의료기관에 전송하기 위한 방법으로 국제표준암호알고리즘인 HIGHT 알고리즘을 적용하여 생체정보 데이터의 부분 암호화 적용을 설계 하였다. 이를 통해 의료기관의 인증서버에 대한 부하 감소 및 환자의 생체정보의 보안 강화를 제시한다.

Effects of Motion Repetition and External Load Depending on Joint Motions (관절 동작에 따른 동작 반복 및 외부 부하 영향에 관한 연구)

  • Dohyung Kee
    • Journal of the Korea Safety Management & Science
    • /
    • v.25 no.2
    • /
    • pp.107-111
    • /
    • 2023
  • This study aims to empirically investigate effects of motion repetition and external load according to joint motion on discomfort through an experiment. Eighteen college students (female: 9; male: 9) participated in an experiment measuring perceived discomfort using the Borg CR10. Joint(wrist, elbow, shoulder and trunk) motion, its repetition and external load were adopted as independent variables. The results showed that all three independent variables were statistically significant on discomfort. Participants' sex also significantly affected discomfort obtained in the experiment. While the interactions of joint motion and repetition, and joint motion and external load were not significant at α = 0.05, that of motion repetition and external load was significant. Based on the experimental results, four regression equations by the joints involved were presented, which could be used as a tool for evaluating postural loads by the joints. It may be postulated that based on the results of this study, scoring systems of RULA and REBA, and those of OWAS and REBA underestimates effects of motion repetition and external load, respectively. It is expected that the results of this study will be used as a basic data for developing an observational method properly reflecting the effects of motion repetition and external load.

Development of Sensor Placement Optimization Algorithm for Smart Container Control (스마트 컨테이너 제어를 위한 센서 위치 최적화 알고리즘 개발)

  • Kim, Jeong-ho;Jeon, Byeong-jin;Park, Byeong-jun;Lee, Sang-jin;Im, Hyeon-seok;Kim, Hyung-hoon
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2022.11a
    • /
    • pp.1047-1049
    • /
    • 2022
  • 스마트 컨테이너 제어를 위해서는 컨테이너 내부에 센서가 필요하나, 센서의 개수가 증가하면 비용 및 시스템 부하가 증가한다. 본 연구에서는 CFD(Computational Fluid Dynamics)를 이용하여 얻은 컨테이너 내부 온도 데이터와 센서 위치 최적화 알고리즘을 이용하여 컨테이너 내부 모니터링을 위한 최적의 센서 위치 결정 방법론을 제시한다. CFD 상용 SW로 컨테이너 내·외부 상황을 가정하여 내부 온도 데이터를 추출하고, 이를 바탕으로 내부 상태를 대표하는 공간들을 구분한다. 컨테이너 내벽에 부착된 센서가 탐지할 수 있는 능력을 탐지 거리 및 각도의 수식들로 나타내어 각 수식을 조합하여 센서의 탐지 능력을 수치화하고, 이 수치에 따라 균등하게 분포된 센서 위치 후보군 중, 선별된 공간을 탐지하는 센서 위치를 최적화하여 효율적인 컨테이너 제어를 위한 여건을 마련한다.

Evaluation of Nutrient Discharges from Greenhouses with Flooding Soil Surface at Two Different Locations (입지조건이 다른 시설재배지에서 담수처리에 따른 양분 용탈량 평가)

  • Kim, Min-Kyeong;Roh, Kee-An;Ko, Byong-Gu;Park, Seong-Jin;Jung, Goo-Bok;Lee, Deog-Bae;Kim, Chul-Soo
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.43 no.3
    • /
    • pp.315-321
    • /
    • 2010
  • Greenhouse soil cultivated with excessive compost and chemical fertilizer has been an issue to deteriorate soil and water quality in the environment. The objective of this study was to evaluate the nutrient outflow by desalting method, flooding soil surface, after vegetable cropping in greenhouse soils. Field experiment from July to September 2008, was conducted to quantify greenhouse locations, i.e. alluvial plain and local valley. The changes of desalinization in both locations were higher as the amounts of irrigated and drained water were increased. Particularly, the ratio of desalinization in alluvial plain was much higher (66.7%) than the one in local valley (45.6%). However, $NH_4$-N contents of local valley soil during the flooding were higher than in those of alluvial plain. This was caused by high total nitrogen and organic matter in local valley soil than those in alluvial plain soil. With comparing to the input and output loads of T-N and T-P in greenhouses with local valley and alluvial plain soils, the output loads of nutrients were larger than the input loads of nutrients. This result showed that the flooding soil surface can be a good treatment to desalinize greenhouse soils. However, this conclusion remained that the flooding water containing high N and P concentrations might cause the secondary effect on the quality of streams and groundwater since excessive nutrient concentrations can be the main cause of eutrophication problem in aquatic environment.

A Program of Water Quality Management for Agricultural Reservoirs by Trophic State (농업용 저수지의 부영양화와 수질관리방안)

  • Lee, Kwang-Sik;Yoon, Kyung-Sup;Kim, Ho-Il;Kim, Hyung-Joong
    • Korean Journal of Environmental Agriculture
    • /
    • v.22 no.2
    • /
    • pp.166-171
    • /
    • 2003
  • A total of 498 agricultural reservoirs ranging from $164{\times}10^3\;m^3$ to $253{\times}10^6\;m^3$ in storage volume were investigated from 1990 to 2001 with respect to Chl-${\alpha}$, COD concentration and pollutant loading of BOD, TN, and TP. The lakes and reservoirs could be classified to 4 types using the relationships between the ratio of storage volume per water surface area(ST/WS) and Chl-${\alpha}$ concentration. It is recommended that the improvement of polluted lakes should be performed in the order of integrated consolidation type ${\rightarrow}$ watershed consolidation type ${\rightarrow}$ in-lake consolidation type ${\rightarrow}$ Management type and reservoir should be constructed to be over $5{\sim}6\;m$ in depth(ST/WS ratio) for preventing the eutrophication of agricultural reservoirs. We propose that water quality criteria for agricultural water is changed from less than 8 mg/L to less than 6 mg/L for safety value, $6{\sim}10\;mg/L$ for concern value, and more than 10 mg/L for countermeasure value in COD concentration, respectively.

Reduction of Pollutant Load by Small Pond in a Rice Paddy Applied with Pig Manure Compost (돈분퇴비가 시용된 논의 양분유출 저감을 위한 저류지 효과)

  • Kim, Min-Kyeong;Kim, Myung-Hyun;Choi, Soon-Kun;Cho, Kwang-Jin;Hong, Seong-Chang;Jung, Goo-Bok;So, Kyu-Ho
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.22 no.4
    • /
    • pp.21-27
    • /
    • 2014
  • Pig slurry has been considered as environmental waste to be treated in an appropriate manner. Moreover, water-born pollution loads by agricultural non-point source(NPS) pollution are expected to become intensified due to ongoing precipitation change. This study was conducted to develop a best management practice to reduce NPS pollution load by agricultural activity with pig manure compost. An eco-friendly way, small drainage pond, was suggested in this study to avoid direct drainage of agricultural runoffs and eventually reduce the amount of pollutants discharged into the surrounding aqua-environment. A small pond($12m^2$) was constructed at the corner of a rice paddy field($17,15m^2$) located in Suwon, Korea. Water was allowed to drain only via a small drainage pond. Sampling was repeatedly made at two locations, one from an entrance and the other from an exit of a pond, during the rice cultivation period(May to October, 2013). Generally, sampling was made only when runoff water drained through a pond, such as during and/or after rain(irrigation). The water quality analysis showed that all quality parameters(SS, $COD_{Mn}$, T-N, and T-P) were improved as water passed through the pond. The amount of runoff water was reduced by 67.8%. Suspended solids and $COD_{Mn}$ concentrations were reduced by 79.8% and 71.9%, respectively. In case of T-N and T-P amounts, the reduction rates were 73.6% and 74.9%, respectively. Our data implies that agricultural NPS pollution from rice paddy fields with pig manure-based fertilizer can be effectively managed when an appropriate drainage water management practice is imposed.

Estimation of Soil Cooling Load in the Root Zone of Greenhouses (온실내 근권부의 지중냉각부하 추정)

  • 남상운
    • Journal of Bio-Environment Control
    • /
    • v.11 no.4
    • /
    • pp.151-156
    • /
    • 2002
  • Root zone cooling, such as soil or nutrient solution cooling, is less expensive than air cooling in the whole greenhouse and is effective in promoting root activity, improving water absorption rate, decreasing plant temperature, and reducing high temperature stress. The heat transfer of a soil cooling system in a plastic greenhouse was analyzed to estimate cooling loads. The thermal conductivity of soil, calculated by measured heat fluxes in the soil, showed the positive correlation with the soil water content. It ranged from 0.83 to 0.96 W.m$^{[-10]}$ .$^{\circ}C$$^{[-10]}$ at 19 to 36% of soil water contents. As the indoor solar radiation increased, the temperature difference between soil surface and indoor air linearly increased. At 300 to 800 W.m$^{-2}$ of indoor solar radiations, the soil surface temperature rose from 3.5 to 7.$0^{\circ}C$ in bare ground and 1.0 to 2.5$^{\circ}C$ under the canopy. Cooling loads in the root zone soil were estimated with solar radiation, soil water content, and temperature difference between air and soil. At 300 to 600 W.m$^{-2}$ of indoor solar radiations and 20 to 40% of soil water contents,46 to 59 W.m$^{-2}$ of soil cooling loads are required to maintain the temperature difference of 1$0^{\circ}C$ between indoor air and root zone soil.