Derivation of Standard Air Temperature Curve for Greenhouse Heating Design and its Application to Heating Degree Hour (온실의 난방설계를 위한 표준기온곡선 유도 및 난방 Degree Hour에의 적용)

  • 김문기;손정익;남상운;유인호;이동근
    • Proceedings of the Korean Society for Bio-Environment Control Conference
    • /
    • 1992.12a
    • /
    • pp.21-22
    • /
    • 1992
  • 온실의 난방에 필요한 난방기기의 용량 및 연료소비량을 합리적으로 추정하기 위해서는 난방설계용 외기조건, 즉 표준기상 데이터가 필요하다. 그러나, 현재 국내에는 건물의 냉난방 설계를 위한 표준기상 자료가 대도시 지역의 일부에 대하여만 발표되어 있다. 이것은 농업시설에 대해서는 적용이 불가능하므로 농업 시설 설계를 위한 개략적인 표준기상 데이터의 선정이 요망된다. (중략)

  • PDF

Effects of climate condition on concrete slab with modified-latex (외기조건이 개질된 라텍스 혼입콘크리트 슬래브 표면에 미치는 영향)

  • Cha, Hun;Kim, Dae-Geon;Choi, Sang-Hwan;Moon, Kyeong-Sik
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.11a
    • /
    • pp.7-8
    • /
    • 2014
  • Latex-modified concrete using ready mix concrete (R-LMC) was developed for application of building construction project (specifically, the rooftop of a parking garage unable to use heavy equipments for bridge deck overlay) due to three major outstanding properties of R-LMC; bond strength, resistance of cracks at early age, and resistance of freezing and thawing. However, R-LMC at the placement stage is required to be sufficiently cured because R-LMC is very sensitive to rate of evaporation of surface moisture. This study focused on effects of different curing methods and climate condition on cracks on the surface of hardened R-LMC considering the chart of rate of evaporation of surface moisture from concrete provided by American Concrete Institute in manual for placement of latex modified concrete.

  • PDF

A Numerical Study on the Characteristics of Plastic Shrinkage Cracking on Concrete Slab with Sequential Placement (분할타설되는 콘크리트 슬래브의 소성수축균열 특성에 대한 해석적 연구)

  • Kwak, Hyo-Gyoung;Ha, Soo-Jun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.4A
    • /
    • pp.795-808
    • /
    • 2006
  • In this paper, an analytical method which can predict the occurrence of plastic shrinkage cracking on concrete slabs with sequential placement is proposed on the basis of the numerical model introduced in the previous study. The influence of many design variables on plastic shrinkage cracking such as the number of layers and the time interval between layers is quantitatively analyzed through parametric studies using the analytical method. In advance, two equations are introduced to take into account the effect of sequential placement on the plastic shrinkage cracking of concrete slab; The first one is to calculate the time at which the surface of concrete slab begins to dry, and the second one is to determine the critical time interval to prevent the surface drying of previously placed concrete layers. The timing of curing and the sequence of concrete placement, which are important for the prevention of plastic shrinkage cracking, can be effectively planned using the introduced both equations without any rigorous analysis.

Study of the Effects of Ambient Temperature and Car Heater Power on the Train Cabin Temperature (외기 온도와 난방 출력의 철도차량 객실 온도에 대한 영향 연구)

  • Cho, Youngmin;Park, Duck-Shin;Kwon, Soon-Bark;Jung, Woo-Sung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.9
    • /
    • pp.5877-5884
    • /
    • 2014
  • Recently, abnormally cold weather has been reported more frequently in winter due to the climate change and abnormal weather changes. On the other hand, the heating capacity of a railcar may be not enough to warm the cabin under severe cold climatic conditions, which is one of the reasons for the passengers' complaints about heating. In this study, the effects of ambient temperature and heater power on the cabin temperature was investigated to obtain the minimum ambient temperature for the tested railcar. The test railcar was placed in a large-climatic chamber, and various ambient temperature conditions were simulated. The effects of the heater output were investigated by monitoring the cabin temperature under a range of heater output conditions. The mean cabin temperature was $14.0^{\circ}C$, which was far lower than the required minimum temperature of $18^{\circ}C$, under a $-10^{\circ}C$ ambient temperature condition with the maximum heat power. When the ambient temperature was set to $0^{\circ}C$ and $10^{\circ}C$, the maximum achievable cabin temperature was $26.1^{\circ}C$ and $34.0^{\circ}C$. Through calculations using the interpolation method, the minimum ambient temperature to maintain an $18^{\circ}C$ cabin temperature was $-6.7^{\circ}C$ for this car. The vertical temperature difference was higher with a higher power output and higher ambient temperature. The maximum vertical temperature difference was higher than $10^{\circ}C$ in some cases. However, the horizontal temperature difference vs. low temperature (< $2^{\circ}C$) was independent of the power output and ambient temperature. As a result, it is very important to reduce the vertical temperature difference to achieve good heating performance.

Study on Dip Variation of STACIR/AW Conductor Using DC Current Facility (STACIR/AW전선의 대전류설비에 의한 실증적 이도특성에 관한 고찰)

  • Shin, Koo-Yong;Lee, Seong-Doo;Min, Byung-Uk;Wi, Hwa-Bok
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.566-568
    • /
    • 2005
  • STACIR/AW은 최근 사용이 증가되고 있는 증용량전선으로 기존 송전선에 비해 많은 전류를 송전하면서도 이도특성이 우수한 장점을 가지고 있다. 이 논문에서는 STACIR/AW 전선의 온도 및 대전류특성에 대한 실증시험을 위하여 구축된 송전선로용 3[kA]급 대전류 발생 장치를 이용해 345kV 송전선로의 표준경간인 350m 시험선로에 $480\;mm^2$$410\;mm^2$ 전선을 가선하여 전류 특성 시험을 수행하였다. 본 논문에서는 최대 허용전류에 대한 단계별 이도특성을 외기 조건과 전선의 장력 변화를 고려하여 고찰하여 국내 주요 전선사의 증용량전선에 대한 신뢰성을 검증하고, 또한 계절별 특성시험 및 환경시험 챔버를 이용한 참고시험과 기본적 동적해석을 통하여 외기 조건에 전선의 최대허용전류를 검토하였다. 또한 실선로에 적용된 $480\;mm^2$$410\;mm^2$ 의 증용량 전선에 최대 부하율을 파악하고 동일 조건에 부하전류를 인가한 실증시험을 통하여 전선의 이도증가율을 분석하여 상용선로의 운전조건을 검토하였다.

  • PDF

A Study on the Foundation of the Standard of Temperature and Humidity for Preventing Condensation in Apartment Housings (공동주택 세대내 결로방지 설계를 위한 실내외 온습도 기준 수립 연구)

  • Hwang, Ha-Jin;Kim, Jong-Yeop;Lee, Jong-Sung
    • Land and Housing Review
    • /
    • v.2 no.3
    • /
    • pp.269-276
    • /
    • 2011
  • Recently, the chance of dew condensation in apartment buildings is increasing because of several reasons. For example, ventilation rate has been decreased because of high-insulations and airtightness for saving energy. Besides, the humidity has been made by drying washes, cooking and bathing inside of apartment buildings. However, there is lack of resonable design criteria for preventing condensation in real life and real surroundings. Therefore, this study is aimed at making a resonable design criteria of preventing condensation by measuring the indoor temperature and humidity in real life. In addition to this, it is aimed at making a resonable outdoor condition and classifying regions by using weather data. The following are the results. The interior criterion for condensation was set up $25^{\circ}C$ and a relative humidity of 55%. The outdoor criterion for condensation was set up $20^{\circ}C$, $-15^{\circ}C$, and $10^{\circ}C$ respectively for the hard frost, middle, and southern areas.

Part2 : Quantitative Analyses of Accumulated Ice Shapes with Various Icing Conditions (Part2 : 착빙 조건 변화에 따른 결빙 형상의 정량적 분석)

  • Son, Chan-Kyu;Oh, Se-Jong;Yee, Kwan-Jung
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.38 no.11
    • /
    • pp.1105-1114
    • /
    • 2010
  • Ice shapes accumulated on the aircraft surfaces are categorized into rime and glaze ice, which are highly dependent on various parameters such as ambient temperature, liquid water contents (LWC), mean volumetric droplet diameter and freestream velocity. In this study, quantitative analyses on the ice accretion have been attempted in a systematical manner and the key findings are as follows. First, the increase of freestream velocity can cause tremendous change in the ice accumulation such as the growth of ice accretion area, ice heading direction and maximum thickness of ice horn. Second, LWC is found to be linearly proportional to the ice accretion area. Third, the effects of ambient temperature on incoming water mass seem to be relatively small in comparison with LWC and freestream velocity. Finally, it was shown that MVD has only a little influence on ice shapes. However, it may increase the ice accretion area by increasing the droplet impacting range.

An Experimental Study for the Effect of Operating Condition of the Air Handling Unit on the Performance of Humidifying Elements (공조기 운전 조건이 가습 소자의 성능에 미치는 영향에 대한 실험 연구)

  • Kim, Nae-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.11
    • /
    • pp.326-331
    • /
    • 2018
  • Evaporative humidification using a humidifying element is used widely for the humidification of a building or a data center. The performance of a humidifying element is commonly expressed as the humidification efficiency, which is assumed to be independent of the air temperature or humidity. To verify this assumption, a series of tests were conducted under two air conditions - data center ($25^{\circ}C$ DBT, $15^{\circ}C$ WBT) and commercial building ($35^{\circ}C$ DBT, $21^{\circ}C$ WBT) - using humidifying elements made from cellulose/PET and changing the frontal air velocity from 1.0 m/s to 4.5 m/s. Three samples having a 100 mm, 200 mm, or 300 mm depth were tested. The results showed that the humidification efficiency is dependent on the air condition. Indeed, even dehumidification occurred at the inlet of the humidifying element at the air condition of commercial building. This suggests that a proper thermal model should account for the inlet area, where the amount of moisture transfer may be different from the other part of the humidification element. As the depth of the element increased from 100 mm to 200 mm, the humidification efficiency increased by 29%. With further increases to 300 mm, it increased by 42%. On the other hand, the pressure drop also increased by 47% and 86%.

The Changes of Conductor Temperature by Current and Environment Component of Wind Velocity and Ambient Temperature (환경 인자(풍속, 외기온도)와 전류량이 전선온도에 미치는 영향)

  • Kim, Shang-Shu;Kim, Byung-Geol;Jang, Tae-In;Kang, Ji-Won;Lee, Dong-Il;Min, Byung-Uk
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.631-632
    • /
    • 2005
  • 대부분의 고압송전선은 알루미늄도체와 강심코어로 구성된 ACSR(Aluminum Conductor Steel Reinforced) 계통으로 건설되었다. 강심코어는 고탄소강으로 전선의 하중을 담당하며 알루미늄은 도체로 사용되고 있다. ACSR $410mm^2$ 가공송전의 온도와 전류량, 외기조건(온도, 풍속, 풍향각)과의 관계를 규명하는 것은 송전용량과 승전효율을 증진하는데 필수적이다. 전선온도는 전류량에 따라 직선적으로 변화하며 풍속 0.5 m/s와 태양열의 흡수가 없다고 가정하면 "전선온도($^{\circ}C$) = -0.3143 + 0.077$\times$전류랑(A)"의 관계를 가진다. 전류랑 852A에서 풍속에 따라 전선의 표면부와 강심부의 망사온도차는 감소하였다. 풍속 20m/s에서의 방사온도차는 약 $1.4^{\circ}C$로 나타났다.

  • PDF

A Study on Performance of Energy Recovery Ventilator under Outdoor Conditions in Korea (국내 외기조건에서 폐열회수 환기장치의 성능에 관한 연구)

  • Kim, Il-Gyoum;Park, Woo-Cheul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.1
    • /
    • pp.52-57
    • /
    • 2009
  • In this study, a simulation program has been developed to predict the performance of energy recovery ventilators fur various indoor and outdoor conditions. In order to get a fundamental data about domestic air condition, the heat recovery ventilator is selected with the product of the wind quantity $250m^3/h$ Japanese M companies which are satisfied at High Efficiency Certification Standards. At the case on which the heat recovery ventilator is established, heating load decreases by 69.1% and cooling load decreases by 59.4% in Seoul, and heating load decreases by 66.4% and cooling load decreases by 59.6% in Pusan. The maximum humidification load of winter or summer time with $0.737{\ell}/h$ or $1.008{\ell}/h$ occurred in March from Kangnung or August from Mokpo respectively. In Southern part region and East Sea of winter time, the condensation or frost on exhaust side dose not occurred on exhaust side, but the area of that outside is occurred. Therefore, the preventive measure from the area except a southern part region and the east coast area must be considered, in order to condense or frost not to occur on exhaustion side in winter.