• 제목/요약/키워드: 왕복 운동

Search Result 129, Processing Time 0.029 seconds

Analysis of the Respiratory Motion Effects on Dose Distribution Using TLD Phantom (열형광선량계용 팬톰을 이용한 호흡 움직임에 따른 선량분포의 평가)

  • Hong, Ju-Young;Kim, Yon-Lae;Rah, Jeong-Eun;Chung, Jin-Beom;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.17 no.4
    • /
    • pp.187-191
    • /
    • 2006
  • The purpose of this study was to measure the dose distribution from the moving phantom for the respiratory motion. The phantom for TLD measurement was designed and built for this study based on the multiple plates for placing TLD and film. The TLDs may be inserted at 3 mm intervals in each TLD plate. For the measurements, TLD plate was inserted into the phantom at 1.5 cm ($d_{max}$) depth, and phantom was allowed to move in SI directions in the range of 1 to 2 cm with 0.5 cm interval for 6 MV X-ray beams. Penumbra and FWHM were measured at both moving state and compared stationary. It was found that penumbra increased 0.71 cm at stationary and 2.10 cm at moving state in 2 cm movement, and that FWHM are 7.52 cm for stationary state and 7.02 cm for moving state (2 cm movement). In this study, film was used to compared with TLD results of measurements and simitar results were observed. Therefore, it is expected that TLD moving phantom may be useful for the treatment of tumors that move due to the respiratory motion.

  • PDF

Wear Characteristics of Cylinder-Liner Materials for Diesel Engine at Elevated Temperature (디젤엔진용 실린더 라이너 소재의 고온 마모특성)

  • Kim, Jin-Yeol;Kim, Jae-Hoon;Oh, Kwang-Keun;Lee, Seung-Hak;Chang, Joon-Yong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.39 no.11
    • /
    • pp.1131-1136
    • /
    • 2015
  • In a diesel engine, the wear of the cylinder liner occurs because of the continuous reciprocating motion of the piston ring. This wear reduces the performance of the diesel engine and shortens its service life. This study evaluated the wear characteristics of GT metal and a conventional metal used for cylinder liners using a ship's diesel engine. Wear tests were performed at temperatures of $25^{\circ}C$, $175^{\circ}C$, and $325^{\circ}C$, and under loads of 10 N, 30 N, and 50 N. The amount of wear, specific wear rate, and friction coefficient were evaluated for each condition. To analyze the wear mechanism, observations were made on an SEM. In the case of both metals, abrasive and adhesion wear occurred on the wear surfaces at room temperature, and corrosion wear was observed at high temperatures. The amount of wear and the specific wear rate of the GT metal were lower than those of the conventional metal at all temperatures, and hence it can be concluded that the wear characteristics of the GT metal are much better.

The Environmental Conservation according to the Development of Cheongok - cave (천곡동굴 개발에 따른 환경 보전)

  • 유영준;이영화
    • Journal of the Speleological Society of Korea
    • /
    • v.45 no.46
    • /
    • pp.69-79
    • /
    • 1996
  • 동굴은 미지의 세계이고, 암흑의 신비로운 지하세계이기 때문에 우리 인간에게는 매우 흥미로운 공간이라고 할 수 있다. 그러므로 이러한 공간을 관광자원으로 활용하여 지역주민이 소득을 올리고, 청소년에게 탐험의 세계, 모험의 세계는 물론 자연학습의 현장으로 활용할 수 있게 하는 바람직한 경우도 있다. 그러나 이러한 경우 동굴이 개발되면 전자와 같은 긍정적인 면이 있는 반면에 동굴의 파괴, 오손 및 오염과 같은 악영향을 가져오게 되므로 동굴을 개발할 당시부터 악영향을 최소하기 위해서는 환경보전과 환경보호에 커다란 관심을 가져야 한다. 따라서 본 연구에서는 이제 동굴 개장이 2개월밖에 되지 않은 천곡동굴이 관광지로 개방됨으로써 나타나게 될 환경변화를 미리 살펴보고 그에 대한 대책을 마련하려고 하였다. 그 결과는 다음과 같다. 첫째, 천곡동굴의 경우 동굴 공간이 넓고 관광통로가 왕복통로로 되어 있어 체동인구가 2배가 되므로 많은 관광객의 출입시 동굴 내부의 기온이 상승하기 때문에 동시에 관람할 수 있는 적정 관람객 수를 조절해야 한다. 둘째, 천곡동굴은 개장 시일이 오래 경과하지 않았기 때문에 퇴적물의 파손이 전무하다고 할 수 있다. 따라서 이 상태를 계속 유지하기 위해서 동굴 내부에 관리인을 상주시킨다거나, 입동객의 소지품을 보관할 수 있는 장소를 마련하여 동굴퇴적물을 훼손할 수 있는 물건의 반입을 애초에 방지하는 방안도 필요하다고 본다. 마지막으로, 동굴 개발 당시 조명을 너무 가깝게 설치한 때문에 개방 후 얼마 되지 않았음에도 불구하고 몇 군데에서 녹색균류가 관측되고 있으므로 조명시설의 원거리 조정이나 간접조명 대책을 강구해야 한다.만 아니라 오류의 크기도 확률적으로 변하는 상황을 모형에 반영하여 보다 현실성있게 모형화하였다.균 6.5점(2-9점)으로 대체로 높게 나타났는데 이는 대중매체와 신문, 잡지류를 통한 지식의 정보가 많기 때문으로 생각된다 비만 정도에 따라서는 유의적인 차이를 보이지 않았다. 5. 비만 정도와 상호간의 관계를 보면 BMI 수치가 높을수록 비만인 형제수가 많았으며, 자신의 비만 자각도도 높았다. 편식율은 비만 정도가 낮을수록 높았으며, 식품섭취 빈도 점수는 비만군에서 높았으나, 저녁식사 후 간식섭취는 BMI가 높은 군에서 하지 않는 비율이 더 높았는데 이것은 감수성이 예민한 여학생들이 자신의 외모에 대한 의식적인 노력으로 보인다. 이상과 같은 결과를 종합해 볼 때 중학교 여학생들은 학교수업을 중심으로 비교적 규칙적인 생활을 하고 따로 운동을 할 시간이 많지 않은 것으로 나타났다. 비만과 관련하여서는 유전적인 요인도 중요하지만 식습관 개선과 식품이 적절한 선택 등을 강조하여 연령과 생활환경에 맞는 영양교육이 필요하다고 본다.알 수 있으며, 현미 30% 첨가한 B2가 그 다음 순위로 선호되어, 백설기 제조에서 율무와 현미의 첨가량은 10%가 권장된다.농촌 지역 여고생보다 많이 섭취하였고, 탄수화물은 농촌지역 여고생이 대도시 지역 여고생에 비하여 유의적으로 많이 섭취하였다. 지역별 여고생의 에너지섭취 비율은 탄수화물 : 단백질 : 지방의 섭취 비율이 대도시 60.75% : 16.4% 22.9%이며, 중소도시가 62.7% : 15.7% : 21.5%,농촌이66.8% : 14. l% : 19.1%이었다. 영양지식의 정확도나 인지도는 영양소 섭취와 유의적인

  • PDF

Development of seam tracking sensing system for welding environment with wall (벽이 있는 용접 환경을 위한 용접선 검출 시스템 개발)

  • Park, Young-Kyun;Byun, Kyung-Seok
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.11 no.4
    • /
    • pp.338-344
    • /
    • 2010
  • Both ends of welding line are often closed by wall in the welding of ship blocks. In this research, seam tracking sensing system for butt welding in the condition with wall was developed. Seam tracking sensing system measures position of carriage from wall and detects root-pass of welding line. The system consists of the laser displacement sensors and ultrasonic sensors. The laser displacement sensor reciprocal1y rotates by the motor and measures a distance from laser sensor to the welding material. The ultrasonic sensor measures a distance between welding system and walls. The distance measured by the ultrasonic sensor is used to get X(driving) position and to determine initial and end point of the weld line. Y(weaving) and Z(height) of the weld line are obtained by the distance measured by the laser displacement sensor and the orientation of the sensor. The sensing system includes the controller that is independent from the welding carriage. The seam tracking sensing system is attached to both side of welding carriage so that interference between welding torch and sensing system can be avoided during the welding. And both side sensing system minimize dead zone. Finally, developed sensing system was adhered to welding carriage and verified usefulness by experiments.

Characteristics of Tide-induced Flow and its Effect on Pollutant Patterns Near the Ocean Outfall of Wastewater Treatment Plants in Jeju Island in Late Spring (제주도 하수처리장 해양방류구 인근해역의 늦은 봄철 조류 특성과 조석잔차류에 의한 오염물질의 분포 특성)

  • KIM, JUN-TECK;HONG, JI-SEOK;MOON, JAE-HONG;KIM, SANG-HYUN;KIM, TAE-HOON;KIM, SOO-KANG
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.26 no.2
    • /
    • pp.63-81
    • /
    • 2021
  • In this study, we investigated the tide-induced flow patterns near the ocean outfall of the Jeju and Bomok Wastewater Treatment Plants (WTP) in Jeju Island by using measurements of Acoustic Doppler Current Meter (ADCP) and a numerical experiment with inserting passive tracer into a regional ocean model. In late spring of 2018, the ADCP measurements showed that tidal currents dominate the flow patterns as compared to the non-tidal components in the outfall regions. According to harmonic analysis, the dominant type of tides is mixed of diurnal and semi-diurnal but predominantly semidiurnal, showing stronger oscillations in the Jeju WTP than those in the Bomok WTP. The tidal currents oscillate parallel to the isobath in both regions, but the rotating direction is different each other: an anti-clockwise direction in the Jeju WTP and a clockwise in the Bomok WTP. Of particular interest is the finding that the residual current mainly flows toward the coastline across the isobath, especially at the outfall of the Bomok WTP. Our model successfully captures the features of tidal currents observed near the outfall in both regions and indicates possibly high persistent pollutant accumulation along the coasts of Bomok.

The Effect of Glide Path on Canal Centering Ability in Reciprocating File System (Reciprocating 파일 시스템에서 Glide Path가 근관만곡도 유지에 미치는 영향)

  • Zang, Ki-Choul;Kim, Jin-Woo;Cho, Kyung-Mo;Park, Se-Hee
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.28 no.3
    • /
    • pp.245-252
    • /
    • 2012
  • The purpose of this study was to evaluate the influence of glide path on canal centering ratio after instrumentation with different single file systems; WaveOne and Reciproc. Reciproc R25 (VDW), WaveOne Primary (Dentsply Maillefer) and PathFile #13, 16, 19 (Dentsply Maillefer) were used in this study. In no glide path groups, Reciproc files and WaveOne files used for canal preparation without glide path. In glide path groups, the PathFile were used before canal preparation. Methylene blue dye was introduced into the canal to obtain a clear pre-instrumentation image. Pre-instrumentation images and post-instrumentation images were scanned using Epson Perfection V700 Photo scanner (Epson, Nagano, Japan). Transparencies of post-instrumentation images were changed and superimposed on pre-instrumentation images using Adobe Photoshop CS 3 (Adobe Systems Incorporated, San Jose, CA, USA). The centering ratio was calculated for each instrumented canal using the following formula: CR=|X1-X2|/Y. It was statistically analyzed using two-way ANOVA at 95% confidential level. The centering ratio in glide path groups were significant less than it in no glide path groups at 3, 4, 5 and 6 mm level. Except 1 and 6 mm level, WaveOne groups had significant less centering ration than Reciproc groups. At 6 mm level, there was no significant difference between WaveOne and Reciproc. In the limitation of this study, creation of a previous glide path before reciprocating motion instrumentation in curved canal appears to be appropriate and WaveOne system can be used for preparation of curved canal without severe aberrations.

The effect of copper alloy scaler tip on the surface roughness of dental implant and restorative materials (구리 합금 초음파 스케일러 팁이 치과 임플란트 및 수복 재료 표면에 미치는 영향)

  • Lee, Ah-Reum;Chung, Chung-Hoon;Jung, Gyu-Un;Pang, Eun-Kyoung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.52 no.3
    • /
    • pp.177-185
    • /
    • 2014
  • Purpose: This study is designed to investigate the various impacts of different types of scaler tips such as cooper alloy base tip and the others on the surface roughness of teeth and implant by the method which is currently in clinical use. Materials and methods: Four different types of disc shaped porcelain, titanium, zirconia, and Type III gold alloy dental materials sized 15 mm diameter, 1.5 mm thickness were used for the experiment. Plastic hand curette (Group PS), cooper alloy new tip (Group IS), and stainless steel tip (Group SS) were used as testing appliances. A total of 64 specimens were used for this study; Four specimens for each material and appliance group. Surface roughness was formed with 15 degree angle in ultrasonic scaler tip and with 45 degree angle in hand curette of instrument tip and the specimen surface with 5 mm long, one horizontal-reciprocating motion per second for 30 seconds by 40 g force. To survey the surface roughness of each specimen, a field emission scanning electron microscope, an atomic force microscope, and a surface profiler were used. (Ra, ${\mu}m$). Results: According to SEM, most increased surface roughness was observed in SS group while IS groups had minimal roughness change. Measurement by atomic force microscope presented that the surface roughness of SS group was significantly greater than those of PS, IS and control groups in the type III gold alloy group (P<.05). IS group showed lesser surface roughness changes compared to SS group in porcelain and gold alloy group (P<.05). According to surface profiler, surface roughness of SS group showed greater than those of PS, IS and control groups and IS group showed lesser than those of SS group in all specimen groups. Type III gold alloy group had large changes on surface roughness than those of porcelain, titanium, zirconia (P<.05). Conclusion: The result of this study showed that newly developed copper alloy scaler tip can cause minimal roughness impacts on the surface of implant and dental materials; therefore this may be a useful alternative for prophylaxis of implant and restored teeth.

Accuracy Evaluation of Tumor Therapy during Respiratory Gated Radiation Therapy (호흡동조방사선 치료 시 종양 치료의 정확도 평가)

  • Jang, Eun-Sung;Kang, Soo-Man;Lee, Chol-Soo;Kang, Se-Sik
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.22 no.2
    • /
    • pp.113-122
    • /
    • 2010
  • Purpose: To evaluate the accuracy of a target position at static and dynamic state by using Dynamic phantom for the difference between tumor's actual movement during respiratory gated radiation therapy and skin movement measured by RPM (Real-time Position Management). Materials and Methods: It self-produced Dynamic phantom that moves two-dimensionally to measure a tumor moved by breath. After putting marker block on dynamic phantom, it analyzed the amplitude and status change depending on respiratory time setup in advance by using RPM. It places marker block on dynamic phantom based on this result, inserts Gafchromic EBT film into the target, and investigates 5 Gy respectively at static and dynamic state. And it scanned investigated Gafchromic EBT film and analyzed dose distribution by using automatic calculation. Results: As a result of an analysis of Gafchromic EBT film's radiation amount at static and dynamic state, it could be known that dose distribution involving 90% is distributed within margin of error of 3 mm. Conclusion: As a result of an analysis of dose distribution's change depending on patient's respiratory cycle during respiratory gated radiation therapy, it is expected that the treatment would be possible within recommended margin of error at ICRP 60.

  • PDF

EVALUATION ON THE ABRASION RESISTANCE OF A SURFACE SEALANT (레진전색제의 마모저항성에 대한 평가)

  • Kim, Soo-Mee;Han, Sae-Hee;Cho, Young-Gon
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.3
    • /
    • pp.180-190
    • /
    • 2007
  • The purpose of this study was to evaluate the abrasion resistance of surface penetrating sealant which was applied on a composite resin restoration and to provide proper time to reapply sealant on composite resin surface. Two hundred rectangular specimens, sized $8\times3\times2mm$, were made of Micronew (Bisco, Inc., Schaumburg, IL, U.S.A) and divided into two groups; F group (n = 10) was finished with coarse and medium grit of Sof-Lex discs and BisCoverwas applied B group (n = 190) after finishing with discs. B group was again subdivided into nineteen subgroups From B-1 group to B-18 group were subjected to toothbrush abrasion test using a distilled water-dentifrice slurry and toothbrush heads B-IM group was not subjected to toothbrush abrasion test. Average surface roughness (Ra) of each group was calculated using a surface roughness tester (Surfcorder MSE-1700: Kosaka Laboratory Ltd., Tokyo, Japan) . A representative specimen of each group was examined by FE-SEM (S-4700: Hitachi High Technologies Co., Tokyo, Japan). The data were analysed using cluster analysis, paired t-test, and repeated measure ANOVA. The results of this study were as follows; 1. Ra off group was $0.898{\pm}0.145{\mu}m$ and B-IM group was $0.289{\pm}0.142{\mu}m$. Ra became higher from B-1 group $(0.299{\pm}0.48{\mu}m$ to B-18 group $(0.642{\pm}0.313{\mu}m$. 2. Final cluster center of Ra was $0.361{\mu}m$ in cluster 1 $(B-IM\simB-7)$, $0.511{\mu}m$ in cluster 2 $(B-8\simB-14)$ and $0.624{\mu}m$ in cluster 3 ($(B-15\simB-18)$. There were significant difference among Ra of three clusters. 3 Ra of B-IM group was decreased 210.72% than Ra of F group. Ra of B-8 group and B-15 group was increased 35.49% and 51.35% respectively than Ra of B-IM group. 4. On FE-SEM, B-IM group showed the smoothest resin surface. B-8 group and B-15 group showed vertically shallow scratches , and wide and irregular vertical scratches on composite resin surface respectively. Within a limitation of this study, finished resin surface will be again smooth and glazy if BisCover would be reapplied within 8 to 14 months after applying to resin surface.