• Title/Summary/Keyword: 왕복 운동

Search Result 129, Processing Time 0.03 seconds

Development of Piston Ring Lubrication for the Ring Pack Arrangement (링팩내의 피스톤링 윤활에 관한 연구)

  • 심현해;권오관
    • Tribology and Lubricants
    • /
    • v.1 no.1
    • /
    • pp.46-58
    • /
    • 1985
  • The basic mechanism of lubrication between the piston ring and the cylinder wall is developed theoretically under the assumption of a reciprocating and dynamically loaded slider-bearing pair of parabolic form and smooth plane. A numerical computation for the prediction in cyclic variations of film thickness, net lubricant flow and frictional behaviour is attempted, and the influenec on the performance characteristics due to the ring height, ring face radius of curvature and the degree of offset, is also examined. The computational procedures develeped for a single ring system are extended and applied further to the complex problem of a ring pack system. It is well known that the ring pressure which is the total load on a ring, can be obtained from either an experimental measurement or a gas flow analysis. In this work, the latter of a gas low analysis method was used to calculate the pressures. It is remarked that the work done was focused on the role of flow continuity and lubricant starvation within the ring pack lubrication.

Design and Analysis of Voice Coil Actuator to Drive Fuel Pump in Automobile (자동차 연료펌프 구동용 보이스 코일 전자기 엑츄에이터의 설계 및 해석)

  • Park, Se-Myung;Kim, Jin-Ho;Bai, Cheol-Ho
    • Journal of the Korean Magnetics Society
    • /
    • v.20 no.6
    • /
    • pp.234-238
    • /
    • 2010
  • Solenoid diaphragm fuel pump, which to replace mechanical fuel pump system by utilizing cam-shaft driving force, is in the spotlight for being a high efficient green car component. However, there is a drawback in power consumption as a solenoid diaphragm fuel pump only relies on solenoid for its flux needed in reciprocating motion. Therefore, this research proposes permanent magnet type VCM (Voice Coil Motor) fuel pump system to minimized power consumption. Furthermore, the study compares and analyzes power consumption and dynamic performance between the current and the former solenoid diaphragm pump by conducting finite element analysis with the commercial electromagnetic solver, MAXWELL.

Comparison and Analysis of Linear Oscillatory Actuator According to Mover Type (왕복운동 리니어 액추에이터의 가동자 형태에 따른 전자기적 특성해석 및 비교)

  • 장석명;최장영;정상섭;이성호;조한욱
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.53 no.4
    • /
    • pp.213-223
    • /
    • 2004
  • In the machine tool industry, direct drive linear motor technology is of increasing interest as a means to achieve high acceleration, and to increase reliability. The advantages of such a motor are that it has a good linearity and has no need of such mechanical energy conversion parts, which change rotary motion into linear motion, as screws, gears, chains etc In this paper, two structures of LOA are analyzed. One is the moving-coil type LOA and the other is moving-magnet type LOA. Two types of LOA are analyzed, with reference to the following parameters as variables: magnetic field, flux linkage, motor thrust and back emf. These variables are derived by the use of analytical method in terms of two-dimensional rectangular coordinate system. The maximum values of thrust according to such design parameters as air-gap length and magnet height for each model is also represented. The results are validated extensively by comparison with finite element method. In particular, we experiment moving-coil LOA which is already manufactured and confirm that the experimental results are shown in good agreement with analysis through the comparison of between analytical and experimental results

Heat Transfer Analysis for Variable Thrust Control System Using 1-Way Coupling (일방향 연계를 활용한 연속가변 추력제어 시스템의 열전달 해석)

  • Lee, JiHun;Jang, HanNa;Kim, GyuBin;Cho, JinYeon;Kawk, JaeSu;Ko, JunBok;Park, SungHan
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.388-391
    • /
    • 2017
  • In this study, heat transfer analysis of variable thrust control system have been conducted by using commercial CFD code and FEM code. We Carried out computational fluid dynamics analysis to obtain the temperature and convective heat transfer coefficient of hot gas of variable thrust control system. Data are used as boundary condition for heat transfer analysis using mapping method. Temperature of O-ring for sealing was predicted

  • PDF

In-line sputtering system에서 Al:ZnO 막의 대면적 증착시 가스 유동의 영향

  • Yang, Won-Gyun;Ju, Jeong-Hun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.194-194
    • /
    • 2010
  • 태양전지용 투명전도막에 사용되는 Al-doped ZnO (AZO) 막은 저가이면서도 가시광역 영역에서 갖는 우수한 투과율과 낮은 비저항을 갖는 특성 때문에 ITO의 대체 재료로서 최근 활발한 연구가 진행되고 있다. 특히, 양산 현장에서는 in-line type의 대형 sputtering system에서 증착하고 있으며 높은 증착 속도와 박막 특성의 균일도가 중요한 과제다. 본 연구에서는 $2\;m\;{\times}\;1\;m\;{\times}\;0.2\;m$의 sputtering system에서 기판 캐리어를 이용해서 커다란 기판을 좁고 긴 타겟의 양쪽으로 왕복 운동을 하는 swing dynamic deposition 방법으로 $272\;mm\;{\times}\;500\;mm$ 크기의 AZO target (Al 2 wt%)을 이용하여 bipolar pulsed dc로 증착하였다. 이 시스템의 배기는 TMP와 cryo pump를 이용해서 $5\;{\times}\;10^{-7}\;Torr$의 기본 진공도를 얻으며, 공정 중에는 TMP만 사용하였다. 하지만, 본 시스템의 TMP는 비대칭 적으로 한쪽에 치우쳐 설치되어 있는데, 이것이 챔버 내에서 공정 가스인 Ar의 유동의 불균일도를 초래하게 되며, 그것이 증착되는 박막의 두께 균일도 및 특성 균일도에 영향을 주고 있음을 알 수 있었다. 본 연구에서는 다른 기본 진공도에서 증착된 AZO 박막의 특성 차이를 알아보고 비대칭 배기 구조가 in-line type 시스템에서 어떠한 두께 및 특성 불균일도를 가져오는지, 그리고 시스템 내부에 발생시키는 압력 불균일도를 상용 3차원 전산 유체해석 프로그램인 CFD-ACE+를 이용하여 분석하였다.

  • PDF

Development and Performance Test of Hydraulic PTO for 50㎾ Class Rotating Body Type Wave Energy Converter (50㎾급 동체회전형 파력발전시스템 유압식 전력변환장치 개발 및 성능시험)

  • Choi, Kyung-Shik;Yang, Dong-Soon;Park, Shin-Yeol;Cho, Byung-Hak
    • Journal of the Korean Society of Mechanical Technology
    • /
    • v.13 no.3
    • /
    • pp.99-106
    • /
    • 2011
  • 50kW급 동체회전형 파력발전시스템(WEC;wave energy converter)의 전력변환장치(PTO; power take-off)를 설계 제작한 후 성능시험을 하였다. 파력발전시스템은 2개의 실린더형 동체가 회전관절로 연결된 구조로 수면의 반정도 잠기는 구조로 되어있다. 파랑에 의해 유도된 회전관전의 움직임이 유압실린더에 힘을 가해주며, 유압실린더는 고압의 작동유를 축압기를 경유하여 발전기에 체결된 유압모터로 공급한다. 유압식 PTO은 유압실린더가 왕복운동하는 움직임을 이용하여 고품질의 전력을 생산하는데 효과전인 수단을 제공한다. 파력발전시스템의 경제성은 PTO의 에너지 변환 효율에 크게 의존한다. 발전기를 AC 380V 전력계통에 연계시킨 후, 발전기에서 나오는 출력이 5, 20, 35, 43kW 일때 PTO 전체와 개별기기에 대한 효율을 측정하였다. 본 논문에서 유압식 PTO시스템의 설계에 대해 설명하였으며 효율 향상에 초점을 맞추어 PTO 성능대해 분석하였다.

The Effect of Fabric Movement on Wrinkle Recovery in a Clothing Care System (의류관리기 내 직물거동이 구김 제거에 미치는 영향)

  • Yu, Dongjoo;Yoon, Juhee;Lee, Sang Wook;Yun, Changsang
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.45 no.2
    • /
    • pp.335-345
    • /
    • 2021
  • The purpose of this study was to examine the effect of fabric movement on wrinkle recovery in a clothing care system and to propose an algorithm to improve wrinkle removal performance by adjusting fabric movements. With an increase in the reciprocating speed of the movement system, the number and amplitude of curves on the fabric also increased. This allowed the fabric to be applied to a larger tension, resulting in better wrinkle removal performance at higher speeds. However, even at high reciprocating speeds, wrinkles could not be removed effectively because of nodes at a few specific locations. Based on the results of fabric movement and wrinkle recovery, a complex movement algorithm was proposed with a mixture of various reciprocation speeds. It showed a 41%p (24%→65%) improvement of wrinkle recovery when compared with the conventional algorithm that showed simple fabric movement at 180 rpm. This was because the positions of nodes and antinodes changed continuously and the force by the reciprocating motion could be applied evenly to the fabric.

Impact of the Planning CT Scan Time on the Reflection of the Lung Tumor Motion (전산화단층촬영 주사시간(Scan Time)이 폐종양운동의 재현성에 미치는 영향 분석)

  • Kim Su Ssan;Ha Sung Whan;Choi Eun Kyung;Yi Byong Yong
    • Radiation Oncology Journal
    • /
    • v.22 no.1
    • /
    • pp.55-63
    • /
    • 2004
  • Purpose : To evaluate the reflection of tumor motion according to the planning CT scan time. Material and Methods : A model of N-shape, which moved aiong the longitudinal axis during the ventilation caused by a mechanical ventilator, was produced. The model was scanned by planning CT, while setting the relative CT scan time (T: CT scan time/ventilatory period) to 0.33, 0.50, 0.67, 0.75, 1.00, 1.337, and 1.537. In addition, three patients with non-small cell lung cancer who received stereotactic radiosurgery In the Department of Radiation Oncology, Asan Medical Center from 03/19/2002 to 05/21/2002 were scanned. Slow (10 Premier, Picker, scan time 2.0 seconds per slice) and fast CT scans (Lightspeed, GE Medical Systems, with a scan time of 0.8 second per slice) were peformed for each patient. The magnitude of reflected movement of the N-shaped model was evaluated by measuring the transverse length, which reflected the movement of the declined bar of the model at each slice. For patients' scans, all CT data sets were registered using a stereotactic body frame scale with the gross tumor volumes delineated in one CT image set. The volume and three-dimensional diameter of the gross tumor volume were measured and analyzed between the slow and fast CT scans. Results : The reflection degree of longitudinal movement of the model increased in proportion to the relative CT scan times below 1.00 7, but remained constant above 1.00 T Assuming the mean value of scanned transverse lengths with CT scan time 1.00 T to be $100\%$, CT scans with scan times of 0.33, 0.50, 0.57, and 0.75 T missed the tumor motion by 30, 27, 20, and $7.0\%$ respectively, Slow (scan time 2.0 sec) and Fast (scan time 0.8 sec) CT scans of three patients with longitudinal movement of 3, 5, and 10 mm measured by fluoroscopy revealed the increases in the diameter along the longitudinal axis Increased by 6.3, 17, and $23\%$ in the slow CT scans. Conculsion : As the relative CT scan time increased, the reflection of the respiratory tumor movement on planning CT also Increased, but remained constant with relative CT scan times above 1.00 T When setting the planning CT scan time above one respiration period (>1.00 T), only the set-up margin is needed to delineate the planning target volume. Therefore, therapeutic ratio can be increased by reducing the radiation dose delivered to normal lung tissue.

Effect of somatosensory input on the gait ability and equilibrium sensory of elderly women (체성감각계 지원이 여성노인의 보행 및 평형감각 유지에 미치는 효과)

  • Jung, Chul;Park, Woo-Yung
    • Journal of the Korean Applied Science and Technology
    • /
    • v.35 no.1
    • /
    • pp.205-213
    • /
    • 2018
  • The purpose of this study was to investigate the effect of somatosensory input on the gait ability and equilibrium sensory of elderly women. The subjects who participated in this study were 31 elderly women with a mean age of 75 years or older who no using a walking stick and had no abnormality in otolaryngology. The control group consisted of 30 elderly women who did not exercise regularly more than twice a week. Dependent variables consisted of 2.44m timed up and go test, 10m usual gait, 10m fast gait and 6minute gait. The equilibrium sensory test was performed using EquiTest (NeuroCom, USA). The results of the study on gait ability were not statistically significant for 2.44m timed up and go test, and 10m usual gait. However, 10m fast gait (P<.001) and 6min gait (P<.05) showed significant differences. According to the results of the study on equilibrium sensory ability, there was no significant difference between Condition 1 and Condition 5 however Condition 2 (P<.01), Condition 3 (P<.01), Condition 4(P<.01) and Condition 6 (P<.05) showed statistically significant differences. In conclusion, walking stick have beneficial effects on walking and equilibrium sensation, and elderly women need to actively use walking stick when going out and walking.

The effect of applying u-health system on metabolic syndrome management of elderly (U-health system 활용이 남녀노인의 대사증후군 관리에 미치는 영향)

  • Chung, Jin-Wook;Sung, Soon-Chang
    • Journal of Digital Convergence
    • /
    • v.11 no.11
    • /
    • pp.553-560
    • /
    • 2013
  • The purpose of this study was to examine the effect of u-health system on metabolic syndrome risk factor, body composition, and fitness in male and female elderly. Subjects were 46 elderly(24 men and 22 women) with metabolic syndrome. They were divided into u-health group and home exercise group. Blood pressure, blood profile, body composition, and fitness were measured before and after the intervention. As a results, blood glucose and waist circumference showed significant interaction in both men and women, respectively. In body composition, weight, muscle mass, fat mass, %body fat, BMI showed significant interaction whereas only muscle mass showed significant differences in women. In fitness, there were interaction shown in 3m up and go, functional reach, and gait speed in men. In women sit to stand, 6min walk, and grip strength showed significant interaction. In conclusion, u-health system seems to be the effective method in terms of checking regularly. However, easier and more simple system for elderly and specific direction for exercise should be added.