• Title/Summary/Keyword: 완전일치

Search Result 269, Processing Time 0.024 seconds

Characteristics of Injection-Locked High Power Diode Laser (고출력 다이오드 레이저의 주입-잠금 과정 연구)

  • 문한섭;김중복;이호성;양성훈;김점술
    • Korean Journal of Optics and Photonics
    • /
    • v.6 no.3
    • /
    • pp.222-227
    • /
    • 1995
  • A single mode, 100-mW diode laser was injection-locked by the master laser which was spectrally narrowed with Littman-type grating feedback. In the incomplete-injection-locking, we observed that two frequencies were simultaneously generated from the slave laser. The power ratio and frequency shift of two frequency components were proportional to the square of injected laser intensity. When the ratio of the injection intensity to the slave laser intensity was about $10^{-3}$, the injection-locking bandwidth was to be about 1.4 GHz. The bandwidth proportionally increased to the square root of the injection intensity, which was in good agreement with the theoretical predictions. The Iinewidth of the locked-laser was about 2.5 MHz, which was five times as narrow as that of free-running operation. ation.

  • PDF

2D Finite Difference Time Domain Method Using the Domain Decomposition Method (영역분할법을 이용한 2차원 유한차분 시간영역법 해석)

  • Hong, Ic-Pyo
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.5
    • /
    • pp.1049-1054
    • /
    • 2013
  • In this paper, two-dimensional(2-D) Finite Difference Time Domain(FDTD) method using the domain decomposition method is proposed. We calculated the electromagnetic scattering field of a two dimensional rectangular Perfect Electric Conductor(PEC) structure using the 2-D FDTD method with Schur complement method as a domain decomposition method. Four domain decomposition and eight domain decomposition are applied for the analysis of the proposed structure. To validate the simulation results, the general 2-D FDTD algorithm for the total domain are applied to the same structure and the results show good agreement with the 2-D FDTD using the domain decomposition method.

Development of an ECCS Injection Model By Gravity and Flow Rate Distributions in the Passive Reactor Systems (비상노심냉각수의 중력에 의한 주입 및 피동형노심내의 흐름율 분포모델의 개발)

  • Lim, H.G.;Kim, G.S.;Lee, U.C.
    • Nuclear Engineering and Technology
    • /
    • v.26 no.4
    • /
    • pp.562-569
    • /
    • 1994
  • In this study improvement of transient analysis model, KOTRAC, for the passive reactor has been performed. In the KOTRAC, mixture drift flux model is adopted to simulate thermal hydraulic behavior, which can simulate ECCS injection in the passive plant. However, there is a difficulty to handle complete phase separation phenomena due to the near-zero density, which may occur in the pressurizer surge line or horizontal flow paths. In this study, a couple of model changes to over-come Courant limit feilure has been examined. One of key features is to substitute flow distribution parameters with Ishii's correlation. Corrected results are nil compared to those of RELAP/MOD3 analysis.

  • PDF

Total Body Irradiation for Allogeneic Bone Marrow Transplantation in Chronic Myelogenous Leukemia (만성 골수성 백혈병에서 동종 골수 이식을 위한 전신방사선조사)

  • Chung Su Mi;Choi Ihl Bohng;Kang Ki Mun;Kim In Ah;Shinn Kyung Sub;Kim Choon Choo;Kim Dong Jip
    • Radiation Oncology Journal
    • /
    • v.12 no.2
    • /
    • pp.209-217
    • /
    • 1994
  • Between July 1987 and December 1992, we treated 22 patients with chronic myelogenous leukemia; 14 in the chronic phase and 8 with more advanced disease. All were received with allogeneic bone marrow transplantation from HLA-identical sibling donors after a total body irradiation(TBI) cyclophosphamide conditioning regimen. Patients were non-randomly assigned to either 1200 cGy/6fractions/3days (6 patients) or 1320 cGy/8 fractions/4days (16 patients) by dose of TBI. Of the 22 patients, 8 were prepared with cyclophosphamide alone, 14 were conditioned with additional adriamycin or daunorubicin. To prevent graft versus host disease, cyclosporine was given either alone or in conjunction with methotrexate. The actuarial survival and leukemic-free survival at four years were $58.5\%$ and $41.2\%$, respectively, and the relapse rate was $36\%$ among 22 patients. There was a statistically significant difference in survival between the patients in chronic phase and more advanced phase ($76\%\;vs\;33\%$, p=0.05). The relapse rate of patients receiving splenectomy was higher than that of patients receiving splenic irradiation ($50\%\;vs\;0\%$, p=0.04). We conclude that the probability of cure is highest if transplantation is performed while the patients remains in the chronic phase.

  • PDF

Improving Grain Quality by Controlling Top Dressing of Nitrogen Application Ratio (일품벼 도정 및 쌀 품질 향상을 위한 분시비율 개선연구)

  • Won, Jong-Gun;Ahn, Duok-Jong;Kim, Se-Jong;Choi, Chung-Don;Lee, Sang-Chul
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.53 no.spc
    • /
    • pp.47-52
    • /
    • 2008
  • This study was carried out to improve the rice grain quality of Ilpum cultivar, especially to reduce the chalky rice rate by controlling top dressing of nitrogen application ratio at the tillering and panicle initiation stage. In the rice plant growth, the number of tiller and leaf area index of maximum tillering stage were influenced by basal dressing and top dressing at tillering stage; however those of heading stage were mainly influenced by top dressing at panicle initiation stage. In yield and yield components, they were influence by the top dressing at panicle initiation stage and the rice yield was increased by percentage of the top dressing. The protein content of rice grain was increased as the rate of top dressing at panicle initiation stage was increased. The rate of chalky and damaged rice was remarkably increased as the top dressing ratio was increased, resulting in reducing the rate of head rice rate. As the results, the characteristics of milling and rice quality was improved when the amount of top dress was reduced as 50% at the panicle initiation stage, and the yield of head rice also increased.

A Study on the Method and System for Organization's Name Authorization of Korean Science and Technology Contents (국내 과학기술콘텐츠 전거데이터 구축을 위한 소속기관명 식별 방법과 시스템에 관한 연구)

  • Kim, Jinyoung;Lee, Seok-Hyong;Suh, Dongjun;Kim, Kwang-Young
    • Journal of Digital Contents Society
    • /
    • v.17 no.6
    • /
    • pp.555-563
    • /
    • 2016
  • Science and technology contents (research papers, patents, reports) are the most common reference material for researchers involved in research and development in the fields of science and technology. Based on various search elements (title, abstract, keyword, year of publication, name of journal, name of author, publisher, etc.), many services are available for users to search science and technology contents and bibliographic information owned by libraries. Authority data on organization name can be useful as an element for author identification and as an element to search for results produced by specific organizations. However, organization name is not taken into account by current search services for domestic academic information and bibliographic records. This study analyzes organization name data contained in the metadata of science and technology contents, which are the basis of the establishment of authority data, and proposes a method and system based on string containment and exact string matching.

Loss of Corrected Visual Acuity According to Different Meridional Visual Acuity in Astigmatic Eyes (난시안에서 주경선 간 시력차이와 교정시력의 손실)

  • Jo, Na Young;Kim, Sang-Yeob;Moon, Byeong-Yeon;Cho, Hyun Gug
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.21 no.1
    • /
    • pp.77-81
    • /
    • 2016
  • Purpose: This study was performed to investigate the difference of meridional visual acuity and the loss of corrected visual acuity (VA) in order to emphasis the importance of astigmatic correction. Methods: 64 subjects (122 eyes) aged $22.75{\pm}2.36years$ participated in this study. After full correction of astigmatic refractive error, VA was measured in which the direction of the slit filter was matched with astigmatic axis and $90^{\circ}$ to the astigmatic axis. Results: 52 eyes showed no difference in VA between the two direction. However 70 eyes had difference VA between them. 14 out of 52 eyes and 24 out of 70 eyes had under 1.0 in monocular VA. The astigmatic degree was higher in the existence of VA difference between the two direction than non-existence. The difference is higher with under 1.0 monocular VA. Monocular VA is closely related to the focal line having better VA in the principal focal line. Glasses replacement period was analyzed as 6~12 months for the preservation of better VA. Conclusions: The final glasses prescription has to be given with full correction because continued under-correction for astigmatism causes meridional VA difference.

Preoperative Three Dimensional Ultrasonographic Evaluation of the Rotator Cuff Tear (회전근 개 파열에 대한 수술 전 3차원 초음파 검사의 유용성)

  • Yum, Jae-Kwang;Sin, Yong-Woon;Han, Jung-Il
    • Clinics in Shoulder and Elbow
    • /
    • v.11 no.1
    • /
    • pp.24-28
    • /
    • 2008
  • Purpose: We wanted to determine if preoperative three dimensional (3D) ultrasonographic evaluation for rotator cuff tear is useful to measure the real size of a torn rotator cuff for performing an operation Materials and Methods: This study included 15 cases (7 males and 8 female), and these patients were confirmed to have a full thickness tear of the rotator cuff by 3D ultrasonography and the operative findings, as well as on the magnetic resonance imaging (MRI). The average age of the patients was 55.4yrs. Results: The average difference between the 3D ultrasonographic and operative measurements of the full thickness tear of the rotator cuff was 0.7 mm in the transverse length and 2.0 mm in the longitudinal length. Conclusion: The low error between the 3D ultrasonographic and intraoperative measurements of rotator cuff tear shows the usefulness of preoperative 3D ultrasonographic evaluation for rotator cuff tear.

Characteristics of Creep Deformation Behavior of Granite under Uniaxial Compression (단축압축하중을 받는 대전 화강암의 크립 변형거동 특성에 관한 연구)

  • 홍지수;전석원
    • Tunnel and Underground Space
    • /
    • v.14 no.1
    • /
    • pp.69-77
    • /
    • 2004
  • Investigation of the time-dependent behavior of rock and the associated mechanisms are of key interest in long-term stability analysis of many engineering applications. In this study, creep tests were performed on Daejeon granite samples of 25.4mm diameter under uniaxial compression at varying stress levels. The effect of moisture was investigated by testing both air-dried and fully water-saturated samples. The creep behavior of Daejeon granite exhibited three distinctive stages of primary, secondary and tertiary creep. The ultimate strength of granite under a constant stress decreased considerably with time. Saturation and immersion of the test specimen in water markedly increased the total creep strain as well as the secondary creep rate. The experimental creep curves are fitted to Burger's model as well as two other empirical models suggested by previous researchers. A number of the parameters determined for each model are dependent on stress and influenced by the presence of water. Based on the experimental results, an empirical relation between the applied stress and the time-dependent strain is established separately for each air-dried and fully water-saturated Daejeon granite.

An Anisotropic Perfectly Matched Layer(APML) for Mesh Truncation in The Finite Difference Time Domain Method (유한차분시간영역(FDTD)법에 있어 Mesh Truncation을 위한 비등방성 완전정합층에 관한 연구)

  • 박동희;김정기
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.9 no.5
    • /
    • pp.678-686
    • /
    • 1998
  • This paper describes an anisotropic perfectly matched layer (APML) for mesh truncation of the Finite Difference Time Domain(FDTD) method. The APML method can classified by a split type and an unsplit type, in case of the split type be made up 12 equations or 8 equations largely, and in case of the unsplit type be made of 6 equations. Therefore the latter is more simple as compare with the former. For the APML method presented in this paper is the latter, is directly derived from the time domain equations of Maxwell and extend to the three dimensional problem for the method suggested by Chen. Especially, in the edge and corner parts except the planes, the APML method effectively treated as compound with the Chen's method and Gedney's method newly. The results of the numerical method in this paper show the radiation patterns and the time responses of electromagnetic fields of the wire antennas according to wavelengths and the APML results are compared with Mur's first order absorbing boundary condition and Kraus's analytical results. Eventually, Mur's first order condition have many errors at the edge and corner. On the other hand, in comparison with Kraus's analytical results, it is quite good agreement, and the validity of present method is confirmed.

  • PDF