• Title/Summary/Keyword: 와건물지

Search Result 156, Processing Time 0.026 seconds

Effects of Shading on the Growth of Hedera rhombea Bean and Pachysandra terminalis Sieb. et Zucc. (차광수준이 송악과 수호초의 생육에 미치는 효과)

  • Jeong, Hyun Hwan;Kim, Ki Sun
    • Horticultural Science & Technology
    • /
    • v.17 no.1
    • /
    • pp.29-32
    • /
    • 1999
  • This experiment was conducted to investigate the effect of different levels of shading (0, 35, 55, 75, 95% to incident sunlight) on the growth of Hedera rhombea Bean and Pachysandra terminalis Sieb. et Zucc. in order to determine optimum light intensity for ground cover plants. H. rhombea showed a upright growth type under 95% shading and P. terminalis was highest under 35% shading. Number of branches was not significantly affected by shading levels. Stem diameter and length were reduced under shading from 35% to 95%. Leaf growth was vigorous under 35% and 55% shade condition. Leaves became longer with decreasing light intensity, but shorter in 95% shading than control. There was a slight trend that total chlorophyll and chlorophyll a, b contents increased with decreasing light intensity, and so did chlorophyll a/b ratio. Fresh and dry weight of both plants were higher under 35, 55, and 75% shading than control and 95% shading. Specific leaf weight tended to decrease with reduction of light intensity. Thus, optimum light intensity for growth of them may be 35 and 55% shading of incident sunlight. In addition, it is possible to grow them under even 75% shading of incident sunlight.

  • PDF

Wi-Fi Based Indoor Positioning System Using Hybrid Algorithm (하이브리드 알고리즘을 이용한 Wi-Fi 기반의 실내 측위 시스템)

  • Shin, Geon-Sik;Shin, Yong-Hyeon
    • Journal of Advanced Navigation Technology
    • /
    • v.19 no.6
    • /
    • pp.564-573
    • /
    • 2015
  • GPS is the representative positioning technology for providing the location information. This technique has the disadvantage that does not operate in the shadow areas, such as urban or dense forest and the interior. This paper proposes a hybrid indoor positioning algorithm, which estimates a more accurate location of the terminal using strength of the Wi-Fi signal from the indoor AP. To determine the location of the user, we establish the most appropriate path loss model for the measurement environment. by using the RSSI value measured in a variety of environment such as building structure, person, distance, etc. The path loss exponent obtained by the path loss model is changed according to the environment. REKF, PF estimate the position of the terminal by using measured value from the AP with path loss exponent. For more accurate position estimation, we select positioning system by the value of threshold measured by experiments rather than a single positioning system. Experimental results using the proposed hybrid algorithm show that the performance is improved by about 17% than the conventional single positioning method.

The Administrative Procedure and the Policy for the Construction of the Goon Office Buildings around the Goon-Rearrangement in 1914 (일제강점기 군폐합(1914) 전후 군청사 건축행정의 절차와 방침)

  • Kim, Myungsun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.7
    • /
    • pp.510-515
    • /
    • 2017
  • The Goon-rearrangement in 1914 caused a significant change in the Goon office buildings' construction in the Japanese colonial period. The aim of this study was to discover the administrative procedure for the construction of them around the Goon-rearrangement and also in the 1910s generally, the Japanese government-general's policy for the construction and the buildings' condition. This study analyzes the official documents for the Goon-rearrangement between the Japanese government-general of Korea and the To, the digital images of the buildings kept in the National Archive of Korea and the newspapers published in 1910s. This paper examines what the effect the construction had under the stance of the Japanese government-general of Korea, which was very passive regarding the construction of new buildings.

Experimental Study on Features of Air Egress Velocity in Vestibule Pressurization System (특별피난계단 부속실 제연설비의 방연풍속 기류특성에 관한 실험적 연구)

  • Ryu, Sung-Ho;Lee, Su-Kyung;Hong, Dae-Hwa;Yoon, Myong-O;Choi, Keum-Ran;Park, Jae-Hyun
    • Fire Science and Engineering
    • /
    • v.24 no.5
    • /
    • pp.79-86
    • /
    • 2010
  • In this study, we confirmed the fact that air egress velocity of pressure differential system which is installed in vestibule of smokeproof stairway in domestic high-rise building becomes back-flow into the vestibule not into the livingroom when the doors open to escape in case of fire by actual measurement. It concerned that fire smoke inflow into the vestibule of smokeproof stairway. so, reflux symptoms were developing the condition does not occur by creating an area of $2m^2$ and a model. if it‘s area is less, airflow in upper area was severely reflux. in the case upward 45 gradient of supply damper’s angle of blade, The results that reflux symptoms include upper door but bottom has some reflux. also vestibule of smokeproof stairway‘s area of $4m^2$ in the living room door in the direction of the flow distributon was normal. if a vestibule of smokeproof stairway is smaller, it designed to be performance-based design should be.

Deregulation of the Fire Prevention Legislation; and Its Impact on Fire Occurrence - Case of the United Kingdom - (′화재예방법규′의 규제완화가 화재발생에 미치는 영향 -영국 사례분석 -)

  • 이재열
    • Fire Science and Engineering
    • /
    • v.15 no.2
    • /
    • pp.13-19
    • /
    • 2001
  • The OECD defines regulatory reform as both better regulation and deregulation, and emphasizes that governments must continue to regulate in areas such as environmental quality and safety. In contrast, Korean regulatory reform in fire services in the 1990s shows quite a strange trend, having been carried out only to the direction of softening and abolishing regulations. In the UK, fire prevention legislation has been strengthened since the enactment of the Fire Precautions Act 1971, and the Building Regulations 1991, which apply to all new buildings including a private house, require that there should be at least one smoke alarm on each floor. This research shows that the tightening of fire prevention legislation in the UK has promoted fire safety, which is very instructive for Korean fire services. In order for Korean fire services to protect citizens'lives and property from fires, one of basic directions of regulatory reform, to improve the quality of regulations relating to safety, health and the environment, should be observed strictly. Moreover, the flexibility of the basic direction of regulatory reform should be ensured so that the regulations concerning safety could be even increased under the overall reform strategy of reducing all regulations.

  • PDF

A Numerical Study on the Influence of the Shaft Geometry on the Stack Effect (수직통로의 형상이 연돌효과에 미치는 영향에 관한 수치해석 연구)

  • Jeon, Heung-Kyun;Choo, Hong-Lok
    • Fire Science and Engineering
    • /
    • v.25 no.4
    • /
    • pp.74-81
    • /
    • 2011
  • The numerical analyses for three different shafts in geometry of high buildings were carried out by using computational fluid dynamics model (FDS ver.5.3) for the calculation of the pressure difference and the location of the neutral plane and the visualization of stack effect. At 10 seconds of stack effect, the pressure difference of stack effect in the elevator shaft (79.3 Pa) almost corresponded to the theoretical value (78 Pa). At 300 seconds of stack effect, all the neutral planes of three cases were located about 49 m above floor, where was 5 m higher than the theoretical value. The maximum pressure difference between upper and lower position of shaft decreased with increasing of the geometrical complexity of shaft. This study showed that there was the difference of the stack effects among the geometries of shafts with the visualization of stack effect.

Effects of Root-Zone Temperature on Antioxidative Enzyme Activities, Mineral Contents, and Growth of Grafted Watermelon Plug Seedlings (근권온도가 수박성형묘의 생육, 무기성분 흡수 및 항산화 효소활성에 미치는 영향)

  • Huh, Moo-Ryong;Kim, Young-Suk;Seo, Young-Guk;Park, Joong-Choon
    • Horticultural Science & Technology
    • /
    • v.18 no.6
    • /
    • pp.783-786
    • /
    • 2000
  • This study was carried out to examine the effect of root-zone temperatures on seedling growth, mineral contents and antioxidative enzyme activities of grafted watermelon. The grafted watermelon seedlings were grown in greenhouse bed for 20 days at root-zone day temperatures of 10, 15, $25^{\circ}C$ while night temperature was maintained at $10^{\circ}C$. Growth such as shoot height, leaf length, leaf number, stem diameter, and fresh and dry weights increased as increasing root-zone temperatures, and leaf area with $25^{\circ}C$($52.79mm^2$) was two times that of control($21.50mm^2$). As increasing the root-zone temperatures, Mn, Ca, Fe contents increased, K, P, Mg were non significant, and Na decreased. The activities of ascorbate peroxidase(APX) and guaiacol peroxidase(GPX) known as antioxidative enzyme were higher at $10^{\circ}C$ than $25^{\circ}C$.

  • PDF

Effect of phenylmercuric 8-oxyquinolinate and phenylmercuric acetate on respiration of Cochliobolus miyabeanus (Phenylmercuric 8-oxyquinolinate 및 phenylmercuric acetate가 호마엽고병균의 호흡작용에 미치는 영향)

  • Kim K. C.;Suh Y. T.
    • Korean journal of applied entomology
    • /
    • v.5_6
    • /
    • pp.65-69
    • /
    • 1968
  • The effect of respiratory inhibition was investigated by treating conidia or mycelium of Cochliobolus miyabeanus with phenylmercuric 8-oxyquinolinate (PMQ) or. phenylmercuric acetate (PMA) in terms of $O_2$ up take ul/mg dry weight of cells. The results obtained are as follows: 1. In inhibition of mycelial growth, PMQ gave somewhat less effective than PMA, hut there was no remarkable difference between them, and the two indicated strong inhibitory effect on mycelial growth at the range from 0.01 to 1.0 ppm. 2. In inhibition of conidial respiration, PMA gave somewhat stronger than PMQ except at 0.1ppm, but there was no notable difference between them, and it seemed that there was no inhibitory effect at 0.01ppm. 3. PMQ was stronger than PMA in inhibition of mycelial respiration as compared with the cibudail respiration, ration, and the difference between them was about $10\%$. 4. According to the above results, the inhibitory effect of spore germimation by PMQ was the same as to PMA or somewhat lower than that of PMA. The inhibitiry effect of PMQ on mycelial growth was lower than that of PMA.

  • PDF

Implementation of an Adaptive Equalizer for the Home Phone Lines (댁내 전화 선로의 적응형 등화기 구현)

  • 이성현;은창수;김홍석
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.26 no.11A
    • /
    • pp.1820-1826
    • /
    • 2001
  • In this paper, we present a modeling scheme for the already-installed two-wire home phone lines with arbitrary topologies and show that the inter-symbol interference due to the topology can be removed using an adaptive equalizer. The transmission characteristics of the arbitrary-configured two-wire home phone lines can be analyzed through the ABCD matrices. The simulation result shows that the impedance mismatch due to the branch lines renders nulls in the frequency response or delayed pulses in the impulse response. These nulls or delayed pulses cause inter-symbol interference that inhibits correct signal detection. An adaptive equalizer is shown to be effective in eliminating the interference. Also, the simulation result shows that the equalizer converges in 1.5 ms at a data rate of 1 Msps at signal-to-noise ratios greater than 15 dB. In addition, from the result of relation between E$\_$b//N$\_$and BER(Bit Error Rate), we can see that E$\_$b//N$\_$o/ more than 19 dB is required for the data communication with a BER less than 10$\^$-5/.

  • PDF

Development and Breeding Direction of Potato Varieties for Diverse Usage in Korea (국내 용도별 감자 품종 개발과 육종 방향)

  • Jang Gyu Choi;Yong Ik Jin;Young Eun Park;Gun Ho Jung;Gyu Bin Lee;Do Hee Kwon;Jae Youn Yi;Ji Hong Cho
    • Proceedings of the Plant Resources Society of Korea Conference
    • /
    • 2023.04a
    • /
    • pp.5-5
    • /
    • 2023
  • 감자(Solanum tuberosum L.)는 식물학적 분류상으로 가지과에 속하는 작물로, 재배기간이 짧고 단위면적당 생산량이 많아 세계적으로 벼, 밀, 옥수수에 이어 네 번째로 재배되고 있다. 감자의 원산지는 남아메리카 안데스 산맥의 고원지대로 유럽을 거쳐 여러 나라들로 퍼져나갔으며, 1824년경 우리나라로 감자가 들어왔다는 기록이 남아있다. 국내 감자 재배작형 비율을 살펴보면, 봄재배가 63%, 여름재배 16%, 가을감자 14%, 그리고 겨울시설재배가 7% 정도를 차지하고 있으며 소비자들에게 연중 햇감자를 공급하고 있다. 1960년대부터 국내에서 감자 교배육종을 시작하면서 육종기반을 구축하였으며 현재까지 40여 품종을 육성하였다. 과거에는 부족한 주식을 대체하기 위한 구황작물로 감자를 주로 소비하였기 때문에, 식용감자 품종 위주로 선발하기 위하여 조숙성과 수량성에 중점을 두어 '조풍', '추백' 등의 품종을 육성하여 보급하였다. 최근 국민 소득의 향상과 식습관 변화 등으로 식품 소비구조가 다양화되면서 감자를 식용뿐만 아니라 감자칩, 프렌치프라이 등 가공제품이나 더 나아가 화장품 원료로 이용되면서 육종 방향과 목표를 다양하게 설정하여 품종을 육성하고 있다. 그 결과로, 전분함량이 높고 칩가공성이 우수한 '다미', '골든볼', '은선' 등 칩가공용 품종, 감자모양이 길고 건물함량이 높아 가공적성이 우수하고 프렌치 프라이로 적합한 '골든에그'와 '얼리프라이', 기형, 열개 등 생리장해 발생이 적고 일반 부식용인 '수선', '추원' 등 다양한 용도를 가진 품종을 육성하여 보급하고 있다. 이와 같이 현재까지 육성된 감자 용도별 주요 품종들의 현황과 육종 방향에 대해서 소개하고자한다.

  • PDF