여름철 사무실내 한국인의 온열감 평가 (Evaluation of Korean Thermal Sensation in Office Buildings During the Summer Season)

  • 배귀남;이철희;이춘식
    • 설비공학논문집
    • /
    • 제7권2호
    • /
    • pp.341-352
    • /
    • 1995
  • In this study, thermal parameters were measured and 213 occupants were also questioned in three office buildings located in Seoul during the summer season. Predicted mean vote-predicted percentage of dissatisfied(PMV-PPD) and standard new effective temperature(SET*) were used for evaluating Korean thermal sensation. The distribution of thermal sensation vote(TSV) and percentage of dissatisfied(PD) is very similar to that of PMV and PPD. By regression analysis, the following regression equation was obtained; TSV=0.339SET*-8.583. In this case, neutral temperature and comfort range are $25.3^{\circ}C$, $23.8{\sim}26.8^{\circ}C$ respectively. Present experimental results obtained from the field study is less sensitive to the temperature change than those obtained from the climate chamber study in Korea. But, thermal sensations are similar to each other near the neutral point. The neutral temperature and comfort range obtained by this experiment are higher than those of ANSI/ASHRAE Standard 55-1974 about $1.4{\sim}1.8^{\circ}C$.

  • PDF

천장복사난방이 인체에 미치는 쾌적성 평가에 관한 연구 (Evaluation of Thermal Comfort in Ceiling Heating System)

  • 이주연;이소다노리오;조관식
    • 한국감성과학회:학술대회논문집
    • /
    • 한국감성과학회 2001년도 춘계학술대회 논문집
    • /
    • pp.104-108
    • /
    • 2001
  • 복사에 의한 냉난방은, 장시간 재실하는 방이나 소음, 기류에 민감한 장소에 적합하고 에너지 절약면에서도 유효한 냉난방 방식이라고 알려져 있다. 일반적으로 널리 알려져 있는 바닥난방은 실온의 수직분포가 균일함으로서 인체에 쾌적한 난방방식으로 알려져 있다. 이것에 비해, 바닥의외의 벽, 천장을 활용한 냉난방설비의 쾌적성에 대해서는 아직 충분히 검토되고 잇지 않다. 따라서 본 연구는 물순환식 복사 냉난방장치를 이용하여 겨울철의 천장복사난방이 인체에 미치는 생리적, 심리적영향을 밝히고 복사난방의 유용성에 대해서 검토하는 것을 목적으로 한다. 실험은 일본 나라여자대학 인공기후실을 이용하였고, 실험조건은 실온 18$^{\circ}C$, 21$^{\circ}C$, 24$^{\circ}C$ 천장온도 $25^{\circ}C$, 3$0^{\circ}C$, 35$^{\circ}C$의 조건을 조합하여 7조건으로 설정하였다. 또, 상대 습도 40%, 기류속도 0.1m/s 이하로 일정하게 유지시켰다. 생리적반응으로는 피부온14점과 직장온을 30초 간격으로 측정하였고, 혈압, 심박수, 체중, 체지방율을 측정하고 심리적반응으로는 온열감, 쾌적감등의 항목을 10분간격으로 측정하였다.

  • PDF

PMV 지표에 의한 개별 공조시스템(PACS)의 쾌적성 평가에 관한 연구 (Evaluation of Thermal Comfort in Task Area with Personal Air-Conditioning System(PACS) b PMV Index)

  • 최익순;정광섭;박영칠;한화택;이정재
    • 설비공학논문집
    • /
    • 제13권7호
    • /
    • pp.647-652
    • /
    • 2001
  • The thermal comfort of indoor spaces is very important factor in our life. Regions, cultures, climates and individual difference for establishing thermally comfortable environments should be considered carefully because these factors have a large influence on the thermal comfort doing some complicated interactions with environmental, psychological and physical elements. Recently, predicted mean vote(PMV) based on the heat transfer theory between environmental factors and human bodies has evaluated by many researchers and widely used nowadays. The objective of this study is to evaluate the thermal comfort in workspaces with personal air conditioning system using the measurements of environmental comfort parameters and the questionnaire survey of occupant's thermal senses with response to the environment.

  • PDF

개별공조시스템(PACA)을 적용한 작업공간에서의 온열환경 특성 및 쾌적성 평가 (Characteristics of Thermal Environment and Evaluation of Thermal Comfort in Task Area with Personal Air-Conditioning System(PACS))

  • 최익순;정광섭;박영철;한화택;이정재
    • 설비공학논문집
    • /
    • 제13권2호
    • /
    • pp.106-114
    • /
    • 2001
  • The office environment of the building has been significantly changed and the office automation(OA) for productivity improvement and efficiency has proceeded. According to thee trends, the concept of office environment was transferred from conventional \"working space\" to \"living space\" or \"creative space\". Thus, occupants in office building have demanded more comfortable and advanced task environment. The objective of this paper is to evaluate the indoor environment of working space with personal air conditioning system using the measurements of environmental comfort parameters and the questionnaire survey of occupants、 thermal sensation response to the environment.n response to the environment.

  • PDF

겨울철 사무실내 온열환경 특성 및 쾌적성 평가 (Characteristics of Thermal Environments and Evaluation of Thermal Comfort in Office Building in Winter)

  • 배귀남;이철희;이춘식;최항철
    • 설비공학논문집
    • /
    • 제7권2호
    • /
    • pp.310-318
    • /
    • 1995
  • In this study, indoor thermal parameters were measured to investigate the characteristics of thermal environments and 138 occupants were questioned to evaluate Korean thermal comfort in office building in winter. Thermal sensation was estimated by using PMV(Predicted Mean Vote) and ET*(New Effective Temperature) indices. Comparing present experimental result with international standards and that of other research, Korean thermal responses were discussed. Seasonal difference between summer and winter was also discussed. It was found that TSV(Thermal Sensation Vote) is more sensitive than PMV to the variation of temperature and that the measured percentage of dissatisfied is higher than PPD(Predicted Percentage of Dissatisfied) in real office building environments. By regression analysis, the following regression equation has been obtained; TSV=0.432ET*-8.814 and neutral temperature is $20.4^{\circ}C$ in this case. Thermal comfort range based on 80% satisfaction is also $19.4{\sim}22.4^{\circ}C$.

  • PDF

여름철 사무실내 온열환경 특성 및 쾌적성 평가 (Characteristics of Thermal Environments and Evaluation of Thermal Comfort in Office Building in Summer)

  • 이철희;배귀남;최항철;이춘식
    • 설비공학논문집
    • /
    • 제6권3호
    • /
    • pp.206-217
    • /
    • 1994
  • In this study, indoor thermal parameters were measured to investigate the characteristics of thermal environments and 212 occupants were questioned to evaluate Korean thermal comfort in office building in summer. Thermal and comfort sensations were estimated using PMV(Predicted Mean Vote) and ET* (New Effective Temperature) which are most widely used nowadays. Comparing this experimental result with international standards and that of other research, Korean thermal responses were discussed. It was found that TSV(Thermal Sensation Vote) is more sensitive than PMV to the variation of temperature and that the measured percentage of dissatisfied is higher than PPD(Predicted Percentage of Dissatisfied) in real office building environments. By regression analysis, the following regression equation has been obtained: TSV=0.461ET*-11.808 and neutral temperature is $25.6^{\circ}C$ in this case. Thermal comfort range based on 80% satisfaction is also $24.0{\sim}26.8^{\circ}C$, which is about $1^{\circ}C$ higher than that of ANSI/ASHRAE Standard.

  • PDF

쿨비즈 복장에 의한 생리적 반응 측정과 주관적 감각평가 (Measurement of physiological response and estimation of subjective sensation with cool biz)

  • 강누리;이지연;나영주
    • 한국감성과학회:학술대회논문집
    • /
    • 한국감성과학회 2009년도 추계학술대회
    • /
    • pp.236-238
    • /
    • 2009
  • 에너지 절약차원에서 냉방을 줄여 지구온난화 방지에 일조하고자 여름철에 가벼운 차림의 의복을 권장하는 쿨비즈 캠페인이 시작되었으나 이의 정량적인 효과를 분석하는 연구가 미흡하였다. 본 연구에서는 여름철 온실가스 줄이기 및 직장인 등의 건강증진 등을 위하여 기후복장 적응형에 대한 범국민 인식 및 실천 필요를 바탕으로, 실험을 통해 쿨비즈에 의한 생리적 반응 측정 및 주관적 감각평가를 실시하였다. 1 차실험은 두 복장(전통의복,기후의복)의 피부온 측정실험으로, 환경온 25, $27^{\circ}C$, 상대습도 50% RH 에서 20 대 성인남성 4 명을 대상으로 실험을 하였다. 피험자는 심신을 안정할 수 있도록 30 분간의 안정기를 가진 후에 60 분 동안 실험을 하였으며, 사무실 내 작업환경과 같은 분위기 조성을 위해 편안하게 의자에 앉아 가벼운 대화나 컴퓨터 워드작업 및 설문을 응할 수 있도록 피험자 앞 책상 위에는 노트북을 설치해 두었고, 실험 진행기간 동안 피부온, 직장온, 습도, 발한량, 열화상 카메라, 온열감, 습윤감, 쾌적감 등과 같은 주관적 감각을 측정하였다. 2 차 실험은 동일 피부온 발현하는 환경온 찾기로 기준온도($27^{\circ}C$)에서 전통복장을 입고 온도를 점진적으로 하강시키면서 $27^{\circ}C$ 기후 복장을 입은 상태의 피부온도와 동일해지는 실내온도를 측정한다. 착의 형태에 따른 피부온도 변화에서 환경온도 $25^{\circ}C$ 전통의복 기후의복에 의한 피부온도의 차이는 전통의복이 최소 0.3~최대 $1.6^{\circ}C$ 더 높게 나타났으며, 환경온도 $27^{\circ}C$에서 전통의복 기후의복에 의한 피부온도의 차이는 대체적으로 전통의복이 최소 0.4~최대 $1.0^{\circ}C$ 더 높게 나타났다. 주관적 감각평가에서도 기후의복보다 전통의복에서 온열감 습윤감 불쾌감이 더 높은 경향을 보였다. 주관적 감각으로는 $25^{\circ}C$ 전통의복과 $27^{\circ}C$ 기후의복에서 중립적인 느낌을 나타냈다.

  • PDF

비타민 E 섬유가 인체생리 반응에 미치는 영향

  • 임순;정명희
    • 복식문화학회:학술대회논문집
    • /
    • 복식문화학회 2004년도 정기총회 및 춘계학술대회
    • /
    • pp.87-88
    • /
    • 2004
  • 본 연구는 피부의 노화방지 및 미백 효과에 탁월한 비타민 E를 섬유에 부착시켜 인체에 미치는 생리적 반응을 보기 위하여 온열감, 습윤감, 쾌적감의 주관적 감각평가와 심박수, 피부온, 의복내 온도 및 습도를 측정하였다. 연구방법 및 결과는 다음과 같다. 실험은 온도 30±1℃, 상대습도 50±15%, 기류 0.2m/s 이하로 설정된 인공기수실에서 실시하였다. 피험자는 평균연령 21세의 건강한 성인여자 5명으로, 체중, 신장 및 체표면적의 평균치는 52.2㎏, 161.2cm 및 155㎡이다. (중략)