• Title/Summary/Keyword: 온습도 환경

Search Result 146, Processing Time 0.029 seconds

Field Survey on Smart Greenhouse (스마트 온실의 현장조사 분석)

  • Lee, Jong Goo;Jeong, Young Kyun;Yun, Sung Wook;Choi, Man Kwon;Kim, Hyeon Tae;Yoon, Yong Cheol
    • Journal of Bio-Environment Control
    • /
    • v.27 no.2
    • /
    • pp.166-172
    • /
    • 2018
  • This study set out to conduct a field survey with smart greenhouse-based farms in seven types to figure out the actual state of smart greenhouses distributed across the nation before selecting a system to implement an optimal greenhouse environment and doing a research on higher productivity based on data related to crop growth, development, and environment. The findings show that the farms were close to an intelligent or advanced smart farm, given the main purposes of leading cases across the smart farm types found in the field. As for the age of farmers, those who were in their forties and sixties accounted for the biggest percentage, but those who were in their fifties or younger ran 21 farms that accounted for approximately 70.0%. The biggest number of farmers had a cultivation career of ten years or less. As for the greenhouse type, the 1-2W type accounted for 50.0%, and the multispan type accounted for 80.0% at 24 farms. As for crops they cultivated, only three farms cultivated flowers with the remaining farms growing only fruit vegetables, of which the tomato and paprika accounted for approximately 63.6%. As for control systems, approximately 77.4% (24 farms) used a domestic control system. As for the control method of a control system, three farms regulated temperature and humidity only with a control panel with the remaining farms adopting a digital control method to combine a panel with a computer. There were total nine environmental factors to measure and control including temperature. While all the surveyed farms measured temperature, the number of farms installing a ventilation or air flow fan or measuring the concentration of carbon dioxide was relatively small. As for a heating system, 46.7% of the farms used an electric boiler. In addition, hot water boilers, heat pumps, and lamp oil boilers were used. As for investment into a control system, there was a difference in the investment scale among the farms from 10 million won to 100 million won. As for difficulties with greenhouse management, the farmers complained about difficulties with using a smart phone and digital control system due to their old age and the utter absence of education and materials about smart greenhouse management. Those difficulties were followed by high fees paid to a consultant and system malfunction in the order.

Field Survey of Greenhouse for Strawberry Culture -Case Study Based on Western Gyeongnam Area- (딸기재배 온실의 현장조사 분석 -서부경남 지역을 중심으로-)

  • Jeong, Young Kyun;Lee, Jong Goo;Yun, Sung Wook;Kim, Hyeon Tae;Yoon, Yong Cheol
    • Journal of Bio-Environment Control
    • /
    • v.27 no.3
    • /
    • pp.253-259
    • /
    • 2018
  • This study set out to select a system to realize an optimal environment for strawberry cultivation greenhouses based on data about the growth and development of strawberry and its environment and to provide basic data for the research of its improved productivity. For these purposes, the investigator conducted a field survey with greenhouses for strawberry cultivation in western Gyeongnam. The findings show that farmers in their fifties and sixties accounted for the biggest part in the age groups of strawberry farmers. While those who were under 50 were accounted for approximately 67.5%, those who were 60 or older accounted for 32.5%. As for cultivation experiences, the majority of the farmers had ten years of cultivation experiences or less with some having 30 years of cultivation experiences or more. All the farmers built an arch type single span greenhouse. Those who used nutrient solutions were about 75.0%, being more than those who used soil. All of the farmers that used a nutrient solution adopted an elevated hydroponic system. The single span greenhouses were in the range of 7.5~8.5m, 1.3~1.8m and 2.5~3.5m for width, eaves, and ridge height, respectively, regardless of survey areas. The rafters interval was about 0.7~0.8m. In elevated hydroponic cultivation, the width, height, and interval of the beds were about 0.25m, 1.2m and 1.0m, respectively. As for the strawberry varieties, the domestic ones accounted for approximately 97.5% with Seolhyang being the most favorite one at about 65.0%. As for the internal environment factors of greenhouses, 38 farmers measured only temperature and relatively humidity. As for hydroponics, the farmers used a hydroponics control system. Except for the farmers that introduced a smart farm system for temperature and humidity control, approximately 85.0% controlled temperature and humidity only with a control panel for side windows and ventilation fans. As for heating and heat insulation, all of the farmers were using water curtains with many farmers using an oil or electric boiler, radiating lamp or non-woven fabric, as well, when necessary.

Effects of Heat-stress on Rumen Bacterial Diversity and Composition of Holstein Cows (고온 스트레스 영향에 따른 홀스타인종 젖소의 반추위내 미생물 균총 변화)

  • Kim, Dong Hyeon;Kim, Myung Hoo;Kim, Sang Bum;Ha, Seung Min;Son, Jun Kyu;Lee, Ji Hwan;Hur, Tai Young;Lee, Jae Yeong;Park, Ji Hoo;Choi, Hee Chul;Lee, Hyun Jeong;Park, Beom Young;Ki, Kwang Seok;Kim, Eun Tae
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.39 no.4
    • /
    • pp.227-234
    • /
    • 2019
  • This study was performed to investigate the effect of heat-stressed environment on rumen microbial diversity in Holstein cows. Rectal temperature and respiration rate were measured and rumen fluid was collected under normal environment (NE; Temperature humidity index (THI)=64.6) and heat-stressed environment (HE; THI=87.2) from 10 Holstein cows (60±17.7 months, 717±64.4 kg) fed on the basis of dairy feeding management in National Institute of Animal Science. The rumen bacteria diversity was analyzed by using the Illumina HiSeqTM 4000 platform. The rectal temperature and respiratory rate were increased by 1.5℃ and 53 breaths/min in HE compared to that in NE, respectively. In this study, HE exposure induced significant changes of ruminal microbe. At phylum level, Fibrobacteres were increased in HE. At genus level, Ruminococcaceae bacterium P7 and YAD3003, Butyrivibrio sp. AE2032, Erysipelotrichaceae bacterium NK3D112, Bifidobacterium pseudolongum, Lachnospiraceae bacterium FE2018, XBB2008, and AC2029, Eubacterium celulosolvens, Clostridium hathewayi, and Butyrivibrio hungatei were decreased in HE, while Choristoneura murinana nucleopolyhedrovirus, Calothrix parasitica, Nostoc sp. KVJ20, Anabaena sp. ATCC 33047, Fibrobacter sp. UWB13 and sp. UWB5, Lachnospiraceae bacterium G41, and Xanthomonas arboricola were increased in HE. In conclusion, HE might have an effect to change the rumen microbial community in Holstein cows.

Comparison of Heating Characteristics of Electric Heating Element Heater and Oil Hot Air Heater in Single Span Greenhouses (전기발열체 난방기 및 유류온풍 난방기의 단동온실 난방 특성 비교)

  • Kwon, Jin Kyung;Kim, Seung Hee;Shin, Young An;Lee, Jae Han;Park, Kyeong Sub;Kang, Youn Koo
    • Journal of Bio-Environment Control
    • /
    • v.26 no.4
    • /
    • pp.324-332
    • /
    • 2017
  • The comparative experiments were conducted for single span greenhouses where cucumbers were cultivated to analyze the effect of heating between a carbon fiber electric heating element heater and an oil hot air heater in terms of the inside climate, energy consumption and plant growth. In order to analyze the effect of heating capacity, 6, 9, and 16 kW of electric powers were supplied to the electric heating element for same setting temperature of 15?. As a result, as the heating capacity increased, the number of ON-OFF cycles of the electric heating element and the temperature inside the greenhouse increased proportionally. In the comparison of two heaters, it was shown that the temperature and relative humidity distributions of the electric heating element installed greenhouse was much uniform than those of the oil hot air heater installed greenhouse. The heating energy consumptions during the heating period of 79 days were 867L for the oil hot air heater and 8,959 kWh for the electric heating element heater, and the heating costs were 607 and 403 thousand won respectively. In the electric heating element installed greenhouse, the cucumber growth was slightly better and the yield was 4.3% higher than those of the oil hot air heater installed greenhouse, but there were no statically significant difference in the cucumber growth and yield between greenhouses.

Analysis on the Effect of the Crown Heating System and Warm Nutrient Supply on Energy Usage in Greenhouse, Strawberry Growth and Production (관부 난방시스템과 온수 양액 공급이 온실 에너지 사용량, 딸기 생육 및 생산성에 미치는 영향 분석)

  • Lee, Taeseok;Kim, Jingu;Park, Seokho;Lee, Jaehan;Moon, Jongpil
    • Journal of Bio-Environment Control
    • /
    • v.30 no.4
    • /
    • pp.271-277
    • /
    • 2021
  • In this study, experiments of local heating on crown and supplying warm nutrient for energy saving and improving growth of 'Seolhyang' strawberry were conducted. The temperature of inside and crown in greenhouses which were control (space heating 8℃) and test (space heating 5℃+crown heating) was measured. In the control greenhouse, the average of temperature and humidity in December was 7.1℃, 87.2%, respectively. In the test greenhouse, the average of temperature and humidity in December was 5.7℃, 88.7%. The temperature of crown and inside the bed were 7.9℃, 10.8℃ in control, 9.3℃, 12.7℃ in test. During the test period, the total 16,847×103 kcal of energy was consumed in control greenhouse including space heating. In test greenhouse including space heating, crown heating and warm water supplying, total 9,475.7×103 kcal of energy was consumed. So, energy consumption in test was 43.8% less than in the control. The total yields of strawberry during test period were 412.7g/plant for test greenhouse and 393.3g/plant for control greenhouse respectively.

무령왕릉보존에 있어서의 지질공학적 고찰

  • 서만철;최석원;구민호
    • Proceedings of the KSEEG Conference
    • /
    • 2001.05b
    • /
    • pp.42-63
    • /
    • 2001
  • The detail survey on the Songsanri tomb site including the Muryong royal tomb was carried out during the period from May 1 , 1996 to April 30, 1997. A quantitative analysis was tried to find changes of tomb itself since the excavation. Main subjects of the survey are to find out the cause of infiltration of rain water and groundwater into the tomb and the tomb site, monitoring of the movement of tomb structure and safety, removal method of the algae inside the tomb, and air controlling system to solve high humidity condition and dew inside the tomb. For these purposes, detail survery inside and outside the tombs using a electronic distance meter and small airplane, monitoring of temperature and humidity, geophysical exploration including electrical resistivity, geomagnetic, gravity and georadar methods, drilling, measurement of physical and chemical properties of drill core and measurement of groundwater permeability were conducted. We found that the center of the subsurface tomb and the center of soil mound on ground are different 4.5 meter and 5 meter for the 5th tomb and 7th tomb, respectively. The fact has caused unequal stress on the tomb structure. In the 7th tomb (the Muryong royal tomb), 435 bricks were broken out of 6025 bricks in 1972, but 1072 bricks are broken in 1996. The break rate has been increased about 250% for just 24 years. The break rate increased about 290% in the 6th tomb. The situation in 1996 is the result for just 24 years while the situation in 1972 was the result for about 1450 years. Status of breaking of bircks represents that a severe problem is undergoing. The eastern wall of the Muryong royal tomb is moving toward inside the tomb with the rate of 2.95 mm/myr in rainy season and 1.52 mm/myr in dry season. The frontal wall shows biggest movement in the 7th tomb having a rate of 2.05 mm/myr toward the passage way. The 6th tomb shows biggest movement among the three tombs having the rate of 7.44mm/myr and 3.61mm/myr toward east for the high break rate of bricks in the 6th tomb. Georadar section of the shallow soil layer represents several faults in the top soil layer of the 5th tomb and 7th tomb. Raninwater flew through faults tnto the tomb and nearby ground and high water content in nearby ground resulted in low resistance and high humidity inside tombs. High humidity inside tomb made a good condition for algae living with high temperature and moderate light source. The 6th tomb is most severe situation and the 7th tomb is the second in terms of algae living. Artificial change of the tomb environment since the excavation, infiltration of rain water and groundwater into the tombsite and bad drainage system had resulted in dangerous status for the tomb structure. Main cause for many problems including breaking of bricks, movement of tomb walls and algae living is infiltration of rainwater and groundwater into the tomb site. Therefore, protection of the tomb site from high water content should be carried out at first. Waterproofing method includes a cover system over the tomvsith using geotextile, clay layer and geomembrane and a deep trench which is 2 meter down to the base of the 5th tomb at the north of the tomv site. Decrease and balancing of soil weight above the tomb are also needed for the sfety of tomb structures. For the algae living inside tombs, we recommend to spray K101 which developed in this study on the surface of wall and then, exposure to ultraviolet light sources for 24 hours. Air controlling system should be changed to a constant temperature and humidity system for the 6th tomb and the 7th tomb. It seems to much better to place the system at frontal room and to ciculate cold air inside tombs to solve dew problem. Above mentioned preservation methods are suggested to give least changes to tomb site and to solve the most fundmental problems. Repairing should be planned in order and some special cares are needed for the safety of tombs in reparing work. Finally, a monitoring system measuring tilting of tomb walls, water content, groundwater level, temperature and humidity is required to monitor and to evaluate the repairing work.

  • PDF

Enhanced Graft-take Ratio and Quality of Grafted Tomato Seedlings by Controlling Temperature and Humidity Conditions (토마토 공정묘의 접목활착율과 묘소질 향상을 위한 접목 활착실내의 적정 온.습도 조건 구명)

  • Vu, Ngoc-Thang;Zhang, Cheng-Hao;Xu, Zhi-Hao;Kim, Young-Shik;Kang, Ho-Min;Kim, Il-Soep
    • Journal of Bio-Environment Control
    • /
    • v.22 no.2
    • /
    • pp.146-153
    • /
    • 2013
  • This study was conducted to enhance graft-take ratio and quality of grafted tomato seedlings by controlling temperature and humidity during the healing and acclimatization processes. Three temperature levels ($20^{\circ}C$, $23^{\circ}C$, and $26^{\circ}C$) were carried out to determine optimum temperature on four rootstocks. In addition, twelve combinations of three relative humidity levels (70%, 80%, and 90%) and four temperature levels ($17^{\circ}C$, $20^{\circ}C$, $23^{\circ}C$, and $26^{\circ}C$) were set up to evaluate the effect of relative humidity and temperature on the graft-take ratio of grafted seedlings. In the other hand, five relative humidity periods (H0, H1, H2, H3, and H4: 90% relative humidity for first 0, 1, 2, 3 and 10 days and afterwards relative humidity was reduced to 70%, respectively) were examined effect of relative humidity periods on the graft-take and quality of grafted seedlings. The higher graft-take ratios (84.0~87.4%) were showed at $23^{\circ}C$ compared to $20^{\circ}C$ and $26^{\circ}C$ in all rootstocks. Graft-take ratios decreased and number of diseased plants increased at high temperature. The graft-take ratios increased with increasing relative humidity in all temperature levels on the $3^{rd}$ and $7^{th}$ day after grafting. However, increasing relative humidity significantly increased percent of diseased plants. The graft-take ratio reduced at ($26^{\circ}C$) and ($17^{\circ}C$) temperature under all relative humidity conditions. The graft-take ratio increased with increasing period of 90% relative humidity. Maximum graft-take ratios were observed in H2 and H3 treatments. Graft-take ratio decreased with increasing 90% relative humidity for 10 days (H4). Diseased plants had not been found in H0, H1, H2, and H3 treatments. Seedling quality was improved through increasing fresh and dry weight of root, compactness, and root morphology of tomato seedlings in H2 and H3 treatments. Therefore, high relative humidity (90%) for first 2 or 3 days and afterwards reduced low relative humidity (70%) at $23^{\circ}C$ condition during healing and acclimatization promoted the graft-take and quality of grafted tomato seedlings.

Development of IoT-based Can Compactor/PET Bottle Crusher Management System (IoT 기반의 캔/PET병 압착파쇄기 관리시스템 개발)

  • Dae-Hyun Ryu;Ye-Seong Kang;Tae-Wan Choi
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.18 no.6
    • /
    • pp.1239-1244
    • /
    • 2023
  • In this study, we developed an IoT-based management system to manage a can/PET crusher. Various sensors such as two load cells, DHT22 temperature and humidity sensor, and fine dust meter were interfaced with ESP32 to construct an IoT device, and a management server was built using Node-RED. The system monitors the weight of pressed cans and shredded PET bottles in real time and sends a text message to the manager when the weight exceeds the predetermined threshold for timely collection. The results of the operational test confirmed that the system provides accurate monitoring and efficient notification functions, and offers the possibility of solving environmental problems by improving the efficiency of waste management such as cans and PET bottles.

Studies on the Generation-to-Generation Transmission of Cytoplasmic Polyhedrosis Virus and the Effect of Their Activation on the Induction in the Next Generation in the Silkworm, Bombyx mori L. (Virus의 경란전염이 차대의 잠작에 미치는 영향에 관한 연구)

  • 임종성;김근영
    • Journal of Sericultural and Entomological Science
    • /
    • v.16 no.1
    • /
    • pp.85-92
    • /
    • 1974
  • Many of studies on the transovarial transmission of occult virus and their activation due to various stresses such as cold or heat treatment, chemical feeding, and nutritional deficiency, etc., in the silkworm, Bombyx mori L. have been made, but any attempts have been not made to control virus diseases by detection of the occult virus-carried moths in the production of silkworm egg of hybrids, because of difficulty to detect occult virus in any stage. Therefore, it may be worth while to disclose whether a sublethal infection of the moths from which active virus are detectable, has the same level of induction rate as that of occult virus activation, thus to apply its results for the reduction of the occurence of virus diseases in silkworm rearing. For these purposes, the following experiment was conducted as one of preliminary steps. In this study, investigations on the generation-to-generation transmission of occult virus and a sublethal infection, and the role of chromosomal gene of the host, Jam 103 and Jam 104 in the Previous generation, and Jam 103 x Jam 103 and Jam 104 f Jam 104 in the next generation were made for the induction of virus diseases due to the transmitted virus. The frequency of cytoplasmic polyhedrosis due to the induction in the F$_1$ generation was markedly higher in the cross-batches, male$\times$female and male$\times$female in which inoculated individuals were used as fem ale parents than in the cross-batches, male$\times$female and male$\times$female in which virus has been not inoculated or inoculated only to male in the previous generation. The tendency of increasing rate was observed in any treatments; such as the inoculations of cytoplasmic polyhedrosis virus (10$\^$5/, 10$\^$6/ 10$\^$7, and 10$\^$8//ml ill different concentration of inocula) , cold-treatment (5$^{\circ}C$, 12hrs or 24hrs), and formalin-feeding treatment (2% or 3%). The shape of polyhedra (tetragonal in outline) examined in the F, larvae was identified as that of the inoculated polyhedra with partial application of immunofluorescent techniques. These results suggests that the cytoplasmic polyhedrosis virus in B. meri L. are transmitted to the next generation through the egg, apparently in the occult state. And the experimental results of various cross-batches revealed the egg cytoplasm plays an important part i the transmission of the occult virus of the cytoplasmic polyhedrosis virus,

  • PDF

Stand Conditions Influencing the Infection of the Korean Pine Blister Rust Caused by Cronartium ribicola (잣나무털녹병 발생에 영향하는 임지환경요인)

  • Kim Hyun Joong;Yi Chang Keun;Sung Jae Mo
    • Korean Journal Plant Pathology
    • /
    • v.3 no.4
    • /
    • pp.277-284
    • /
    • 1987
  • Infection rate of the blister rust was investigated with special reference to the effect of eight stand factors at 221 plots selected from 131 Korean pine(Pinus koraiensis S. et Z,) stands, and the data were analyzed by multivariated statistical analysis. Environmental factors such as the density of Pedicularis spp., alternate hosts of the Korean pine blister rust, altitude, stand age, aspect, and pruning treatment, from the highest to the lowest were found to be related to the occurrence of the rust disease, Density of Pedicularis spp, was the most closely related to the' infection rate than any other factors, Especially, Pedicularis spp. growing naturally inside the pine stand had an important effect on the infection rate, but those on the outside more than 100m away had little effects, The higher the elevation, the heavier the infection rate. Infection was the heaviest at the altitudes of above 1,000m with high relative humidity and cool temperature. Infection rate was severe in young stands below 10 years old and had a reducing tendency as they mature. Stands above 16 years old were more resistant. The infection rate by the aspect of stand was higher at E- NE and W -SW exposures than at S-SE and N -NW. The infection rate at non-pruning stands was higher than at pruning stands with the lowest branch being at least 60cm high from the ground.

  • PDF