• Title/Summary/Keyword: 온도-습도 지수

Search Result 96, Processing Time 0.019 seconds

An Evaluation of Human Thermal Comfort and Improvement of Thermal Environment by Spatial Structure (공간 구조별 열쾌적성 평가와 열환경 개선방안)

  • Lee, Jung-A;Jung, Dae-Young;Chon, Jin-Hyung;Lee, Sang-Moon;Song, Young-Bae
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.38 no.5
    • /
    • pp.12-20
    • /
    • 2010
  • The purpose of this study is to evaluate human thermal comfort by spatial structure and to explore solutions to improve the thermal environment of a small urban space. The study site was Korea University campus. Thermal conditions were measured to evaluate the quality of the thermal environment in each type of space within the study site. Micrometeorology measurements, analysis of space characteristics for using fish-eye lens photography, and thermal comfort modeling through the use of collected meteorological data, such as temperature and humidity, were performed. Results showed that the level of thermal comfort for humans differs depending on the types of space within the study site. Thermal comfort is better in open spaces than enclosed in the aspect of radiative mean temperature, Predicted Mean Vote(PMV), and Physiologically Equivalent Temperature(PET). This fact is probably due to shadows or buildings or trees that may block solar radiation. Thus, it is necessary to consider the spatial arrangements of buildings and trees to enhance openness and ventilation in the space. Paving materials and exterior building materials should also be selected to lower the radiant temperature. Given these results, a quantitative evaluation on human thermal comfort could propose a way to plan user comfortable small urban spaces. Study methods used and results provided in the study can promote a better way for urban space planning direction to improve environmental quality.

Life Table of the Greenbug, Schizaphis graminum (Rondani) (Homoptera: Aphididae) on Barley, Hordeum vulgare L. (보리를 기주로 한 보리두갈래진딧물[Schizaphis graminum (Rondani)]의 생명표)

  • Kim, Ji-Soo;Lee, Jang-Ho;Kim, Tae-Heung;Lee, Sang-Guei;Yun, Jong-Chul
    • Korean journal of applied entomology
    • /
    • v.46 no.1 s.145
    • /
    • pp.37-42
    • /
    • 2007
  • To construct a life table and development model Schizaphis graminum (Rondani), its adult longevity and fecundity were studied at various constant temperatures ranging from 15 to $32.5^{\circ}C$, with $65{\pm}5%$ RH, and a photoperiod of 16L:8D. Adult longevity of the greenbug gradually increased with decreasing temperature below $32.5^{\circ}C$. Total fecundity was not significantly different at all temperatures except at $32.5^{\circ}C$. Daily fecundity gradually increased from $25.0^{\circ}C$. It was 3.6 at $27.5^{\circ}C$ and as temperatures either went down or up, it decreased to 1.4 at $15.0^{\circ}C$ and 0.4 at $32.5^{\circ}C$ Net reproduction rate (Ro) was highest with 47.6 at $25.0^{\circ}C$. The intrinsic rate of increase per day $(r_m)$ and the finite rate of increase per day $({\lambda})$ were highest with 0.4 and 1.5 at $30.0^{\circ}C$, respectively and the doubling time (Dt) was shortest with 0.98 at $32.5^{\circ}C$. The mean generation time (T) was 8.41 at $30.0^{\circ}C$.

Evaluation of Water Stress Using Canopy Temperature and Crop Water Stress Index (CWSI) in Peach Trees (복숭아나무의 엽온 및 작물수분스트레스 지수를 이용한 수분스트레스 평가)

  • Yun, Seok Kyu;Kim, Sung Jong;Nam, Eun Young;Kwon, Jung Hyun;Do, Yun Soo;Song, Seung-Yeob;Kim, Minyoung;Choi, Yonghun;Kim, Ghiseok;Shin, Hyunsuk
    • Journal of Bio-Environment Control
    • /
    • v.29 no.1
    • /
    • pp.20-27
    • /
    • 2020
  • The study was performed to calculate canopy temperatures and crop water stress index (CWSI) of 2-year-old 'Yumi' peach trees using thermal infrared imaging under different soil water conditions, and to evaluate availability for water stress determination. Canopy temperatures showed similar daily variations to air temperatures and they were higher during the daytime than air temperatures. Canopy temperatures for 24 h were correlated highly to air temperatures (r2 =0.95), solar radiations (r2 =0.74), and relative humidity (r2 =-0.88). In addition, soil water potential showed a highly negative correlation to canopy temperatures (r2 =-0.57), temperature differences between leaf and air (TD) (r2 =-0.71), and CWSI (r2 =-0.72) during the daytime (11 to 16 h). CWSI for 24 h was highly related to canopy temperatures (r2 =0.90) and TD (r2 =0.92), whereas CWSI was not correlated to soil water potential (r2 =-0.27) for 24 h but related highly to water potential (r2 =-0.72) during the daytime (11 to 16 h). Correlation coefficients between CWSI (y) and soil water potential (x) were highest from 11 to 12 h and a regression equation was deduced as y = -0.0087x + 0.14. CWSI was calculated as 0.575 at -50 kPa, which soil water stress generally occurs. Thus our result suggests that this regression equation using thermal infrared imaging is useful to evaluate soil water stress of peach trees.

Analysis of Thermal Environment Improving Effects of Green Curtain in Summer (Green Curtain 형식의 벽면녹화시스템을 통한 여름철 건물 실내 열환경 비교 분석)

  • Lee, Sunyoung;Jo, Sangman;Park, Sookuk
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.50 no.5
    • /
    • pp.80-89
    • /
    • 2022
  • In order to solve the limitations of horizontal thermal environment improvement, this study compared the thermal environment of the indoor and outdoor of a building in summer according to the presence or absence of a green curtain, a vertical greening method. In the summer of 2021, the air temperature, relative humidity, wind speed, and shortwave and longwave radiation were measured at a central point inside a building and the grass field outside of the building to determine the human thermal sensation index, PET and UTCI. As a result, the green curtain showed an average 1.6℃ cooler air temperature during the daytime, but it did not have an effect at night. For relative humidity, it showed higher humidity indoors by an average of 5.6% and 1.0% during the daytime and at night, respectively. Wind speed was 1.4-1.8 ms-1 and 1.4-1.5 ms-1 higher outdoors on average during the daytime and at night, respectively, showing a high value outdoors regardless of whether a green curtain was installed. The green curtain showed an average indoor mean radiant temperature reduction effect of 4.7℃ during the daytime, but it did not have an effect at night. In PET and UTCI, the green curtain reduced the indoor PET by about a 1/3 level, an average of 2.1℃, and the indoor UTCI by about a 1/6 level, an average of 1.1℃, during the daytime. However, no effects appeared in PET and UTCI at night. For landscape planning, a green curtain can effectively modify the thermal environment during the daytime in summer.

Particulate Matter and CO2 Improvement Effects by Vegetation-based Bio-filters and the Indoor Comfort Index Analysis (식생기반 바이오필터의 미세먼지, 이산화탄소 개선효과와 실내쾌적지수 분석)

  • Kim, Tae-Han;Choi, Boo-Hun;Choi, Na-Hyun;Jang, Eun-Suk
    • Korean Journal of Environmental Agriculture
    • /
    • v.37 no.4
    • /
    • pp.268-276
    • /
    • 2018
  • BACKGROUND: In the month of January 2018, fine dust alerts and warnings were issued 36 times for $PM_{10}$ and 81 times for PM2.5. Air quality is becoming a serious issue nation-wide. Although interest in air-purifying plants is growing due to the controversy over the risk of chemical substances of regular air-purifying solutions, industrial spread of the plants has been limited due to their efficiency in air-conditioning perspective. METHODS AND RESULTS: This study aims to propose a vegetation-based bio-filter system that can assure total indoor air volume for the efficient application of air-purifying plants. In order to evaluate the quantitative performance of the system, time-series analysis was conducted on air-conditioning performance, indoor air quality, and comfort index improvement effects in a lecture room-style laboratory with 16 persons present in the room. The system provided 4.24 ACH ventilation rate and reduced indoor temperature by $1.6^{\circ}C$ and black bulb temperature by $1.0^{\circ}C$. Relative humidity increased by 24.4% and deteriorated comfort index. However, this seemed to be offset by turbulent flow created from the operation of air blowers. While $PM_{10}$ was reduced by 39.5% to $22.11{\mu}g/m^3$, $CO_2$ increased up to 1,329ppm. It is interpreted that released $CO_2$ could not be processed because light compensation point was not reached. As for the indoor comfort index, PMV was reduced by 83.6 % and PPD was reduced by 47.0% on average, indicating that indoor space in a comfort range could be created by operating vegetation-based bio-filters. CONCLUSION: The study confirmed that the vegetation-based bio-filter system is effective in lowering indoor temperature and $PM_{10}$ and has positive effects on creating comfortable indoor space in terms of PMV and PPD.

Development of Evaluation Method for Jointed Concrete Pavement with FWD and Finite Element Analysis (FWD와 유한요소해석을 이용한 줄눈콘크리트포장 평가법 개발)

  • Yun, Kyong-Ku;Lee, Joo-Hyung;Choi, Seong-Yong
    • International Journal of Highway Engineering
    • /
    • v.1 no.1
    • /
    • pp.107-119
    • /
    • 1999
  • The joints in the jointed concrete pavement provide a control against transverse or longitudinal cracking at slab, which may be caused by temperature or moisture variation during or after hydration. Without control of cracking, random cracks cause more serious distresses and result in structural or functional failure of pavement system. However, joints nay cause distresses due to its inherent weakness in structural integrity. Thus, the evaluation at joint is very important. and the joint-related distresses should be evaluated reasonably for economic rehabilitation. The purpose of this paper was to develop an evaluation system at joints of jointed concrete pavement using finite element analysis program, ILLI-SLAB, and nondestructive testing device. FWD. To develop an evaluation system for JCP, a sensitivity analysis was performed using ILLI-SLAB program with a selected variables which might affect fairly to on the performance of transverse joints. The most significant variables were selected from precise analysis. An evaluation charts were made for jointed concrete pavement by adopting the field FWD data. It was concluded that the variables which most significantly affect to pavement deflections are the modulus of subgrade reaction(K) and the modulus of dowel/concrete interaction(G), and limiting criteria on the performance of joints at JCP are 300pci. 500,000 lb/in. respectively. Using these variables and FWD test, a charts of load transfer ratio versus surface deflection at joints were made in order to evaluate the performance of JCP. Practically, Chungbu highway was evaluated by these evaluation charts and FWD field data for jointed concrete pavement. For Chungbu highway, only one joint showed smaller value than limiting criterion of the modulus of dowel/concrete interaction(G). The rest joints showed larger values than limiting criteria of the modulus of subgrade reaction(K) and the modulus of dowel/concrete interaction(G).

  • PDF