• Title/Summary/Keyword: 온도 측정

Search Result 9,445, Processing Time 0.04 seconds

정전기력을 이용한 나노 힘 표준기

  • 김민석;최인묵;박연규;강대임
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.125-125
    • /
    • 2004
  • 최근에 급속히 발달하고 있는 나노 기술(NT)파 생명공학 기술(BT)로 인해 미세한 영역에서의 역학적 측정이 중요시되고 있다. 질량, 힘, 온도, 압력 등의 기본적인 물리량들의 정확한 측정이 거시세계와 마찬가지로 나노 물질의 제조, 현상의 규명에 필수적인 요건이기 때문이다. 이중에서 미세 힘측정은 나노 압입 시험, 탄소나노튜브의 기계적 특성측정, MEMS 구조물의 특성평가, 근육 세포의 근력측정, DNA나 생체 분자력 측정 등 광범위하게 사용되고 있다.(중략)

  • PDF

An Experimental study to estimate physical properties of porous media by a permittivity method (유전율법에 따른 다공질 매질의 특성 파악을 위한 실험적 연구)

  • 김만일;니시가끼마코토
    • The Journal of Engineering Geology
    • /
    • v.13 no.4
    • /
    • pp.405-418
    • /
    • 2003
  • Measurements of volumetric water content and saturation of porous media are very important factors in understanding the physical characteristics of soil, groundwater recharge by rainfall, pollutant movement, and slope failure. To measure such physical parameters, a permittivity method using electromagnetic wave is applied and use is made of the special permittivity response of understand to water and ethanol. In particular, the estimation is required because permittivity is influenced by the nature of the underground environment. In this study, we carried out experiments on the relative dependency of soil density, temperature and salinity of standard sand and granitic weathered soil using FDR-V system (Frequency domain reflectometry with vector network analyzer) within a frequency range of 1 - 18 GHz. The results of the study showed that the dielectric constants of standard sand and granitic weathered soil increased with increased volumetric water content of soil. However, the dependency of soil density was found to be a little low. Changes of dielectric constant with temperature appeared definitely in the real part of 1 GHz. That is, the dielectric constant of real part at 1 GHz of water and standard sand increased with the rise of temperature. However, ethanol showed decreased tendency. The study also showed that dielectric constant increased with increase in salinity at imaginary part of 1 GHz. It could be concluded from this study FDR-V system can adequately measure the physical properties of soil and the degree of salinity concentration of porous media within 1 GHz frequency range using dielectric constant.

Study of spatial temperature distribution during combustion process in a high temperature and pressure constant volume chamber (고온 고압 정적 연소실에서 연소과정에 따른 온도 분포 측정)

  • Kim, Ki-hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.1
    • /
    • pp.345-350
    • /
    • 2017
  • Downsizing is widely applied to diesel engines in order to improve fuel efficiency and reduce exhaust emissions. Engine sizes are becoming smaller but pressure and temperature inside combustion chambers are increasing. Therefore, research for fuel spray under high pressure and temperature conditions is important. A constant volume chamber which simulates high temperature and pressure likely to be found in diesel engines was developed in this study. Pressure and temperature were increased abruptly because of ignition of the pre-mixture in the constant volume chamber. Then pressure and temperature were gradually decreased due to the heat loss through the chamber wall. Fuel spray occurred when temperature and pressure were reached at the target condition. In this experiment, the temperature condition should be exactly defined to understand the relation between fuel evaporation and ambient temperature. A fast response thermocouple was developed and used to measure the temporal and spatial temperature distribution during the combustion process inside the combustion chamber. In the results, the core temperature was slightly higher than the bulk temperature calculated by the gas equation. Ed-note: do you want to say 'ideal gas equation'? This was attributed to the heat transfer loss through the chamber wall. The vertical temperature deviation was higher than the horizontal temperature deviation by 5% which resulted from the buoyancy effect.

Prediction of Microstructure and Hardness of the Ductile Cast Iron Heat-treated at the Intercritical Temperatures (임계간 온도에서 열처리한 구상흑연주철의 미세조직 및 경도 예측)

  • Nam-Hyuk Seo;Jun-Hyub Jeon;Soo-Yeong Song;Jong-Soo Kim;Min-Su Kim
    • Journal of Korea Foundry Society
    • /
    • v.43 no.6
    • /
    • pp.279-285
    • /
    • 2023
  • In order to predict the mechanical properties of ductile cast iron heat treated in an intercritical temperature range, samples machined from cast iron with a tensile strength of 450 MPa were heat-treated at various intercritical temperatures and air-cooled, after which a microstructural analysis and Brinell hardness test were conducted. As the heat treatment temperature was increased in the intercritical temperature range, the ferrite fraction in the ductile cast iron decreased and the pearlite fraction increased, whereas the nodularity and nodule count did not change considerably from the corresponding values in the as-cast condition. The Brinell hardness values of the heat-treated ductile cast iron increased gradually as the heat treatment temperature was increased. Based on the measured alloy composition, the fraction of each stable phase and the hardness model from the literature, the hardness of the ductile cast iron heat treated in the intercritical temperature range was calculated, showing values very similar to the measured hardness data. In order to check whether it is possible to predict the hardness of heat-treated ductile cast iron by using the phase fraction obtained from thermodynamic calculations, the volumes of graphite, ferrite, and austenite in the alloy were calculated for each temperature condition. Those volume fractions were then converted into areas of each phase for hardness prediction of the heat-treated ductile cast iron. The hardness values of the cast iron samples based on thermodynamic calculations and on the hardness prediction model were similar within an error range up to 27 compared to the measured hardness data.

Multi-junction thermocouple for temperature gradient measurements (온도구배 측정용 다중접점 열전대)

  • Kim, Yong-Gyoo;Gam, Kee-Sool
    • Journal of Sensor Science and Technology
    • /
    • v.4 no.2
    • /
    • pp.3-6
    • /
    • 1995
  • Type K thermocouples having multi-junction for measuring the temperature gradient of the furnace were fabricated. The obtained results on the temperature gradient of the electric furnace maintained at $800^{\circ}C$ were consistent with those for the reference grade type S thermocouple, which was carefully calibrated, within the permitted error limit of the type K thermocouple. It was suggested that noble metal multi-junction thermocouples be suitable for more accurate temperature gradient measurements.

  • PDF

진공에서의 Organic Light Emitting Diodes (OLEDs)용 유기재료의 상전이 측정

  • Sim, Seop;Kim, Jin-Tae;Sin, Jae-Su;Gwon, O-Hyeon;Yun, Ju-Yeong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.147.2-147.2
    • /
    • 2014
  • Organic Light Emitting Diode (OLED)에 사용되는 유기재료 N,N.-diphenyl-N,N.-bis(1-naphthyl)-1,1'-biphenyl-4,4"-diamine(NPB)의 상전이 특성을 여러 진공도에서 평가하였다. 압력, 온도제어가 가능한 진공시스템을 사용하여 여러 진공도에서 NPB의 상전이 온도를 측정하였고, 본 연구에 사용된 진공시스템의 신뢰성을 검증하기 위해 상압에서 측정한 NPB의 melting temperature를 Differential Scanning Calorimetry(DSC) data와 비교하였다. 또한 각 압력($10^{-7}{\sim}760Torr$)에서 측정한 상전이 온도를 바탕으로 최종 결과물인 NPB의 Phase diagram을 얻어냄으로써 일정 압력, 일정 온도에서의 NPB의 상거동을 예측할 수 있었다. 이러한 결과는 기존의 DSC열분석으로는 확인하기 어려웠던 진공에서의 유기재료의 상전이를 관측하였다는데 큰 의미가 있다. 향후, 이러한 방법을 활용한 진공에서의 유기재료의 상전이 특성 관측은 유기재료를 이용한 진공 증착공정방법의 최적화와, 다양한 유기재료의 열안정성 특성 파악에 도움이 될 것으로 기대가 된다.

  • PDF

전력기술.정보 - 태양광발전시스템의 설치 현장 출력 측정 방법

  • Kim, Eung-Sang
    • Electric Engineers Magazine
    • /
    • s.334
    • /
    • pp.30-35
    • /
    • 2010
  • 본 고에서는 현장에 설치된 태양광발전시스템의 출력 측정 방법을 제시 하였다. 태양광발전시스템은 햇빛이라는 자연조건에 따라서 출력이 수시로 변동하기 때문에 태양전지 제조자가 제시하는 규격은 제작시에 태양전지를 표준 시험조건(즉, STC, Air Mass 1.5, 일사량 1000[$W/m^2$], 온도 $25^{\circ}C$기준)에서 시험한 성능 규격을 제시하고 있다. 그러나 적용현장에 설치된 태양전지는 인위적으로 표준 시험조건을 만들어 줄 수 없기 때문에 출력을 측정하면 제조자가 제시한 성능 규격이 제대로 나오는지 여부가 관심사다. 그렇기 때문에 설치현장에서 자연 조건에서 측정된 출력에다 태양전지 제작사에서 제시한 온도 및 일사량 특성곡선에서 추출된 보정계수를 적용하여 보정 출력을 산정해서 보정 출력을 토대로 제조사에서 제시한 규격에 부합하는 지 여부를 판단할 수 있는 방법을 제안하였다.

  • PDF

Self-Energy-Supporting Environment Monitoring System for Plants Using Solar Cells (태양광을 이용한 에너지 자립형 식물 생장 모니터링 시스템 설계)

  • Son, Youngdal;Eun, Changsoo
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2016.05a
    • /
    • pp.5-6
    • /
    • 2016
  • 본 논문에서는 솔라셀을 사용하여 외부에서 별도의 전원 공급이 필요없는 식물 생장 모니터 시스템을 제안한다. 식물 생장 모니터링을 위해 필요한 대기 온도, 습도와 토양의 온도, 수분 함유 상태를 측정할 수 있는 센서를 설치하고 원격지로 측정 데이터를 전송할 수 있는 통신 장치로 서버로 전송한다. 적합한 솔라셀의 용량과 충전배터리의 용량을 결정하기 위하여 식물 생장을 측정하기 위한 센서부의 소비 전력과 통신부의 소비 전력을 측정하여 산출된 용량값을 가지는 솔라셀과 충전배터리를 부착하여 실시간 모니터링 시스템을 구축하였다. 본 시스템으로 고부가가치 농업 분야에서 식물 생장 모니터링이 확대됨에 따라 외부 전원이 필요없는 간편한 원격 모니터링 서비스가 제공될 것이다.

  • PDF

유도 결합 플라즈마에서의 기체 유량에 따른 전자 에너지 분포의 전이

  • Lee, Hyo-Chang;Jeong, Jin-Uk
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.468-468
    • /
    • 2010
  • 유도 결합 플라즈마에서 기체 유량에 따른 전자 에너지 분포 측정과 그에 따른 플라즈마 밀도와 전자 온도의 변화를 관찰하였다. 기체 압력 제어는 조임 밸브 (Throttle valve) 부근의 압력측정을 통한 조임 밸브 조절 방법을 이용하였으며, 이 방법은 공정 플라즈마에서 널리 쓰이는 압력 조절법이다. 낮은 기체 유량에서 측정된 전자 에너지 분포는 두 개의 온도 그룹을 갖는 bi-Maxwellian 분포를 보였다. 하지만, 기체 유량이 증가함에 따라서 전자 에너지 분포는 Maxwellian 분포로 전이를 하였으며, 플라즈마 밀도의 증가와 전자 온도의 감소를 보였다. 이러한 분포 함수의 변화는 기체 압력이 증가함에 따라 나타나는 전자 가열 모드 전이 현상과 일치하였으며, 이는 압력 조절부와 방전 공간 사이의 압력 구배에 의한 것으로 여겨진다. 이러한 결과는 방전 공간과 압력 조절부에서의 기체 압력 측정을 통하여 검증되었으며, 간단한 유체 모델을 통하여 설명될 수 있다.

  • PDF

CIGS 박막 태양전지에서의 온도 스트레스에 의한 전기적 특성 및 효율 변화 분석

  • Kim, Sun-Gon;Choe, Byeong-Deok
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.327.2-327.2
    • /
    • 2014
  • CIGS박막 태양전지의 온도에 의한 효율과 전기적 특성 변화를 알아보기 위해 $25^{\circ}C$, $50^{\circ}C$, $100^{\circ}C$, $150^{\circ}C$, $200^{\circ}C$에서 각각 100시간을 노출시킨 후 전기적인 특성들을 측정하여 초기 값들과 비교하였다. 태양전지의 온도 스트레스에 의한 특성 및 파라미터들의 변화들을 확인하기 위해 Light I-V와 Minority Carrier의 Lifetime을 측정하여 비교 분석하였다. 실험에 사용한 소자의 초기 파라미터들은 $25^{\circ}C$에서 측정하였고, 단락전류 11mA, 개방전압 0.64V, 곡선인자 60.49%, Lifetime 10.7s 효율 9.17%이다. 각 온도별 노출에 대해 CIGS박막 태양전지의 효율은 $50^{\circ}C$, $100^{\circ}C$에서는 초기 값과 비슷하였고, $150^{\circ}C$, $200^{\circ}C$에서 초기 값 대비 54%, 84% 감소 특성을 보였다. 단락전류는 $50^{\circ}C$, $100^{\circ}C$, $150^{\circ}C$에서는 크게 변화하는 모습이 나타나지 않았고 $200^{\circ}C$에서 63% 감소하였다. 개방전압, 곡선인자, Lifetime은 효율과 마찬가지로 $150^{\circ}C$, $200^{\circ}C$에서 감소하는 모습이 나타났다. $150^{\circ}C$, $200^{\circ}C$에서 개방전압이 9.3%, 18.7%, 곡선인자는 45.8%, 56.3%정도 감소하였다. Lifetime은 64.4%, 80.1%정도 감소하였다. 이 실험을 통해 개방전압과 곡선인자, Minority Carrier의 Lifetime이 일정 온도부터 온도의 영향을 받아 감소하고, 그 영향으로 효율이 감소하게 되는 것을 확인하였다.

  • PDF