• Title/Summary/Keyword: 온도 전달

Search Result 1,061, Processing Time 0.031 seconds

Analysis of the thermal fluid flow between the gas torch and the steel plate for the application of the line heating (선상 가열을 위한 가스 토치와 강판 사이의 열유동 해석)

  • Jong-Hun Woo;Jong-Gye Shin
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.39 no.2
    • /
    • pp.52-60
    • /
    • 2002
  • Line heating is a forming process which makes the curved surface with the residual strain created by applying heat source of high temperature to steel plate. in order to control the residual strain, it is necessary to understand not only conductive heat transfer between heat source and steel plate, but also temperature distribution of steel plate. In this paper we attempted to analyze is temperature distribution of steel plate by simplifying a line heating process to collision-effusive flux of high temperature and high velocity, and conductive heat transfer phenomenon. To analyze this, combustion in the torch is simplified to collision effusive phenomenon before analyzing turbulent heat flux. The distribution of temperature field between the torch and steel plate is computed through turbulent heat flux analysis, and the convective heat transfer coefficient between effusive flux and steel plate is calculated using approximate empirical Nusselt formula. The velocity of heat flux into steel plate is computed using the temperature distribution and convective heat transfer coefficient, and temperature field in the steel plate is obtained through conductive heat transfer analysis in which the traction is induced by velocity of heat flux. In this study, Finite Element Method is used to accomplish turbulent heat flux analysis and conductive heat transfer analysis. FEA results are compared with empirical data to verify results.

증착온도가 CVD Cu 박막의 미세구조 및 전기비저항에 미치는 영향

  • 이원준;민재식;라사균;김동원;박종욱
    • Journal of the Korean Vacuum Society
    • /
    • v.4 no.S1
    • /
    • pp.118-128
    • /
    • 1995
  • Copper(l) hexafluoroacetonate trimethylvinylsilane [Cu(hafac)(TMVS)]를 precursor로 사용하여 증착온도 $160~330^{\circ}C$ 범위에서 TiN 모재 위에 낮은 전기비저항값(~2 $\mu$$\Omega$.cm)을 갖는 CVD Cu 박막을 제조하였고, 증착온도에 따른 Cu 박막의 특성을 조사하여 증착온도가 Cu 박막의 미세구조와 전기비저항에 미치는 영향을 고찰하였다. Cu 증착의 활성화에너지는 표면반응제한지역(surface-reaction-limited region)에서 10.8 kcal/mol 이었다. 표면반응에 의해 증착속도가 결정되는 증착온도 $200^{\circ}C$ 이하에서 증착된 Cu 박막은 낮은 비저항값을 갖는 치밀한 박막이었고 step coverage 또한 우수하였다. 이에 반해 물질전달이 증착속도를 결정하는 증착온도 $200^{\circ}C$이상에서 증착된 Cu 박막은 연결상태가 불량한 구형의 결정립들로 이루어져 있어서 높은 비저항값과 거친 표면형상을 나타내었다. 이와 함께 증착온도에 따른 Cu 박막의 결정립 크기, 배향성 등도 조사하였다.

  • PDF

finite Element Analysis of Nonisothermal Flows in Single-Screw Extruders (싱글-스크류 압출공정에서의 비등온 유동의 유한요소 해석)

  • 권태헌
    • The Korean Journal of Rheology
    • /
    • v.3 no.1
    • /
    • pp.56-67
    • /
    • 1991
  • 압출공정에서 발생하는 전달현상을 이해하기 위하여 싱글-스크류 압출기에서의 비 뉴톤성 유체의 비등온유동에 대한 수치해석을 위한 유한요서법(FEM)을 개발하였다. FEM 은 준-3차원 물리적 모델을 기본으로 하였고 온도분포해석을 위하여 전진방법을 도입하였 다. 본 연구에서 도입한 수치해석적 모델과 더 간단한 준-2차원 모델을 온도분포의 예측에 관하여 초점을 맞추어서 비교 하였다. 압출기의 내부채넬에서 순환유동이 온도분포에 미치 는 영향의 중요성이 강조되었다. 순환유동의 효과를 파악하기 위하여 유한 요소식에서 순환 과 관련된 대류항을 빼도록 유한요소 프로그램을 개조 하였고 개발된 원래의 프로그램과 개 조된 프로그램의 해석을 수행한후 해석결과 중에서 특히 온도분포에 있어서의 차이점을 비 교하였다. 이로부터 간단한 준-2차원 모델은 순환효과를 무시했기 때문에 속도분포의 예측 에서는 별문제가 없으나 온도분포의 예측에 있어서는 크게 잘못될 수 있음을 알수 있다.

  • PDF

Photochemical Index Analysis on the Influence of LED Illumination Color Temperature on Donarium Cherry (도시야간조명의 LED 색온도별 겹벚나무의 광화학적 생리지표 해석)

  • Kim, Ji-Su;Yoo, Sung-Yung;Kim, Hway-Suh;Kim, Tae-Wan
    • Korean Journal of Environmental Biology
    • /
    • v.36 no.2
    • /
    • pp.117-123
    • /
    • 2018
  • In this study, the efficiency of photosynthetic electron transfer according to LED color temperature was verified in order to find a way to efficiently grow trees under night illumination. The experiment was carried out with White treatment, Warmwhite treatment, and non-treatment with donarium cherry. The study uses to a method for analyzing and evaluating the color temperature of an LED light source by photochemical analysis. We found that all treatments 115 DAT of maximum fluorescence amount(P) had the lowest. In the treatment using white light and the Warm-white light, the T amount of florescence of the late stage during the transition of the J-I level was increased, and the photosystem I electron transfer efficiency was decreased. Therefore, the electron transport efficiency of $RE1_O/CS$ and RE1o/RC were reduced. Especially, compared to Warmwhite, the light intensity increased greatly in the white-light treatment, The $PI_{TOTALABS}$ of 7 DAT was the highest value, but it was decreased to the lowest value on 115 DAT. This study has shown that the white treatment was low in electron transfer efficiency and soundness. Warmwhite-light treatments showed lower stress.

The Implementation of TMM test phantom for evaluating the thermal performance in High Intensity Focused Ultrasound system (강력 집속 초음파 시스템의 열적 성능 평가를 위한 팬텀 개발에 관한 기초연구)

  • Yu, Woo-Jin;Noh, Si-Cheol;Park, Moon-Kyu;Min, Hae-Ki;Park, Jae-Hyun;Choi, Heung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2008.10b
    • /
    • pp.484-485
    • /
    • 2008
  • 초음파는 의학적 진단 및 치료의 목적으로 널리 사용되어 왔다. 일반적으로, 초음파 조사의 생물학적 무해성은 많은 연구를 통하여 보고되었으나, 최근 초음파 집속을 통한 강력 초음파의 사용에 대한 열적 안전성 평가가 중요한 요소로 대두되고 있다. 이에 본 연구에서는 강력 집속 초음파의 전달 에너지와 열적 분포를 측정하여 안전성 평가에 활용 가능한 초음파 열분포 팬텀을 제안하였다. 온도 분포 측정용 팬텀은 초음파 조직유사 팬텀 재료인 한천을 이용하였으며, 음향학적 특성의 유사성을 평가하였다. 온도 효과를 측정하기 위하여 $3{\times}3$의 형태로 온도 센서를 팬텀 내부에 배열하여 초음파 조사에 따른 온도 분포를 측정하였고 온도 측정을 위한 시스템을 개발하여, 초음파 가열 실험을 수행하였다. 본 연구에서 제안된 초음파 온도 분포 측정용 팬텀의 유용성을 확인하였으며, 온도 분포용 팬텀을 통한 강력 집속 초음파 장비의 열적 성능 평가에 적용 될 수 있을 것으로 사료되었다.

  • PDF

Combined raidation-forced convection in a circular tube flow (원관내 유동에서의 복사 및 강제대류 열전달에 관한 연구)

  • 임승욱;이준식;이택식
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.14 no.6
    • /
    • pp.1652-1660
    • /
    • 1990
  • Combined radiative-convective heat transfer in a hot gas tube flow has been investigated numerically and experimentally. In the numerical analysis, a standard k-.epsilon. model is used for the evaluation of turbulent shear stresses and spherical harmonics method with the Weighted Sum of Gray Gases Model for the solution of radiative transfer equation. In the experimental study measured are the velocity and temperature of the hot gas flow generated by the propane gas combustion, and tude wall heat flux distribution. Numerical results are compared with experimental ones and it is confirmed that P-3 provides quite reliable results in the analysis of the combined radiation-convection system.

A Study of Life Characteristic of Hydraulic Hose Assembly by Adopting Complex Accelerated Model with Acceleration Factors of Pressure and Temperature (압력과 온도 복합가속모형을 적용한 유압호스 조립체 수명특성 연구)

  • Lee, Gi-Chun;Kim, Hyoung-Eui;Cho, You-Hee;Kim, Jae-Hoon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.11
    • /
    • pp.1697-1703
    • /
    • 2010
  • Hydraulic hoses are used as pipelines for transferring power from hydraulic systems in various machineries such as construction equipments, automobiles, and aircraft. Hydraulic hoses protect the system from vibration or impacts, and they are being used to transfer energy in all segments of the industry. In order to protect the system from various external environmental conditions, hydraulic hose assemblies must be able to withstand a wide range of temperatures and pressures, as well as variations in other factors. In previous studies, an acceleration model for the hydraulic hose assembly was developed by taking into account only one of the acceleration factors (temperature or pressure). Therefore, the objective of this study is to develop a comprehensive acceleration model that takes both temperature and pressure into consideration.

Structural Fire Analysis of a Composite Beam Protected by Fire-Resistant Materials (내화피복을 적용한 강합성보의 구조화재해석)

  • Jun Won Kang;Moon Soo Kang;Hyejin Yoon
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.36 no.2
    • /
    • pp.137-145
    • /
    • 2023
  • This paper presents the effects of fire-resistant materials on the temperature and vertical deflection of a composite beam exposed to fire through nonlinear thermo-mechanical analysis. The fire was modeled using the standard fire curve proposed in American Society for Testing and Materials (ASTM) E119. Fire-resistant materials were modeled by reducing the heat transfer coefficient from the air layer to the beam. The temperature and vertical deflection of the uncoated composite beam were measured using a laboratory fire test, and the results of the structural fire analysis were verified through comparison with experimental results. By introducing the fire-resistance effect, the reduction in the temperature and deflection of the beam for the ASTM E119 standard fire can be reasonably estimated. Based on a case study of the heat transfer coefficient, the fire-resistant effect on the thermo-mechanical response of a composite beam in the event of a fire is presented.

단일 밴드 중적외선 영상을 이용한 표면온도 추정 방법 연구

  • Park, Uk;Lee, Yun-Gyeong;Won, Jung-Seon;Lee, Seung-Geun;Kim, Jong-Min
    • Proceedings of the KSRS Conference
    • /
    • 2008.03a
    • /
    • pp.125-130
    • /
    • 2008
  • Mid-Infrared (MIR) 영상은 화산 활동 및 산불로 인한 재난관측, 지표물질 관측, 해수 온도 측정과 같은 분야들에서 사용되고 있다. 그러나 MIR영역은 지표의 복사율과 대기의 영향으로 인한 변화가 매우 심하고, 낮 영상의 경우 태양 복사량에 의한 영향도 고려해야 하는 어려움이 있다. 따라서 단일밴드인 MIR영상을 이용하여 표면온도를 얻기 위해서는 영상이 취득된 시간과 장소에서 관측된 태양 복사량 및 여러 가지 대기 변수가 필요하다. 본 연구의 목적은 기존의 MIR 영상 연구가 다중밴드를 기반으로 한 것과 달리 단일 밴드의 영상을 이용하여 표면온도를 측정하는데 있다. 이를 위하여 MODIS MIR 영상을 대상으로 MODTRAN을 사용하여 MIR 영역의 대기보정 기법을 적용 한 뒤 복사전달 모델을 이용하여 지표의 복사량을 측정하였다. 획득된 지표온도 영상의 정밀도를 측정하기 위해서 기존의 온도 알고리즘인 split-window algorithm에 의해 얻어진 해수온도 영상과의 비교를 통하여 오차 원인에 대해 분석을 실시하였다. 그 결과 낮 영상의 경우 -4.19${\pm}$1.19$^{\circ}C$ 정도의 온도 차가 났으며, 밤 영상의 경우 0.5$^{\pm}C$0.39$^{\circ}C$ 정도로 비교적 좋은 결과를 보였다. 이는 낮 영상의 경우 지표의 복사율에 대한 온도의 민감도가 매우 높기 때문에 높은 오차가 발생하지만, 밤 영상의 경우 태양빛에 의한 영향이 없으므로 좋은 결과를 나타내기 때문이다. 따라서 단일밴드 MIR영상을 이용한 지표온도 추정 시 대기에 의한 영향보다 지표 복사율에 의한 영향이 높다고 추정할 수 있다.

  • PDF

Numerical Simulation for Deposition Rate Distribution of AI Film by MOCVD Process (MOCVD법에 의한 AI 박막의 증착속도 분포에 대한 수치모사)

  • Jeong, Won-Yeong;Kim, Do-Hyeon
    • Korean Journal of Materials Research
    • /
    • v.6 no.1
    • /
    • pp.99-105
    • /
    • 1996
  • 본 연구에서는 TIMA를 전구체로 하는 수직형 MOCVD 반응기를 대상으로 수학적 모델을 세우고 컴퓨터에 의한 수치모사를 수행하여 반응기 설계 변수 및 공정조건이 AI의 증착속도와 증착두께 분포에 미치는 영향을 알아보았다. 수학적 모델은 수직형 반응기를 축대칭으로 보아 2차원으로 수립하였으며 반응기내의 운동량전달, 열전달, 물질전달을 포함한다. 이 수학적 모델의 지배 방정식들에 대하여 Galerkin 유한요소법을 적용하여 수치적으로 반응기 내의 유체 흐름 구조, 온도분포와 반응물의 농도 분포를 구하였다. 수치모사 결과 AI의 증착속도는 반응기 압력이 0.47torr, 기판온도가 25$0^{\circ}C$, 유량이 7.5sccm일 경우, 190-230$\AA$/min로 나타났다.

  • PDF