• Title/Summary/Keyword: 온도측정장치

Search Result 908, Processing Time 0.025 seconds

Microcomputer-based Data Acquisition System for the Measurements of Temperature and Weight in Food Processing (마이크로 컴퓨터를 이용한 식품가공(食品加工) 공정중(工程中)의 온도및 무게 측정용(測定用) Analog-digital 변환(變換)및 접속(接續) 시스템의 제작(製作))

  • Choi, Boo-Dol;Chun, Jae-Kun
    • Korean Journal of Food Science and Technology
    • /
    • v.19 no.2
    • /
    • pp.129-133
    • /
    • 1987
  • To develop a microcomputer-based data acquisition system for measurement of variables such as temperature and weight in food process, a low-cost data acquisition system was developed using an Apple II microcomputer. The system consisted of a microcomputer, a temperature sensor made of pt-100, a strain gauge load cell for weighing, a preamplifier for signal conditionings and an interface device. Interface device was built with programmable interface chip MC 6821, tristate buffer 74244 and analog-to-digital converter ADC 0809. The analog signals of temperature and weight were serially acquisited upon the program. The BASIC language was used for operating the data acquisition and data handling programs. The system successfully measured the variables such as temperature and weight with various sampling intervals in food dehydration process.

  • PDF

Measurement of Elastic Modulus of Structural Ceramics by Acoustic Resonance Method (공진법을 이용한 구조용 세라믹의 탄성계수 측정)

  • An, Bong-Yeong;Kim, Yeong-Gil;Lee, Seung-Seok
    • Korean Journal of Materials Research
    • /
    • v.5 no.3
    • /
    • pp.268-274
    • /
    • 1995
  • 세라믹재료의 동탄성계수 측정을 위한 공진주파수 측정장치를 구성하였다. 구조용 세라믹 재료로 이용되는 $Al_{2}$O_{3}$, SiC, $Si_{3}$N_{4}$의 온도를 120$0^{\circ}C$까지 5$0^{\circ}C$의 온도간격으로 올리면서 torsional resonant frequency와 flexural resonant frequency를 측정하고, 측정된 공진주파수로부터 각 재료의 탄성계수를 구하였다. SiC의 경우는 120$0^{\circ}C$의 온도까지 탄성계수가 선형적으로 감소하였으나, $Al_{2}$O_{3}$와 $Si_{3}$N_{4}$의 경우에는 각각 100$0^{\circ}C$와 80$0^{\circ}C$까지는 선형적으로 감소하나, 그 이상의 온도에서는 탄성게수의 감소폭이 증가하는 현상을 보였다. 이러한 현상은 다결정재료에서의 grain boundary sliding에 의한 것으로 알려져 있다. 상온에서 공진법으로 측정된 동탄성계수의 측정결과는 초음파법으로 측정한 결과와 비교하였는데, 4% 내에서 서로 일치하는 결과를 보였다.

  • PDF

Measurement and Prediction of Fire and Explosion Properties of 3-Hexanone (3-헥사논의 화재 및 폭발 특성치의 측정 및 예측)

  • Ha, Dong-Myeong
    • Journal of the Korean Institute of Gas
    • /
    • v.17 no.6
    • /
    • pp.33-38
    • /
    • 2013
  • For the safe handling of 3-hexanone(ethyl propyl ketone), this study was investigated the explosion limits of 3-hexanone in the reference data. The flash points and AITs(auto-ignition temperatures) by ignition delay time were experimented. The lower flash points of 3-hexanone by using closed-cup tester were experimented at $18^{\circ}C$. The lower flash points of 3-hexanone by using open cup tester were experimented in $27^{\circ}C{\sim}32^{\circ}C$. This study measured relationship between the AITs and the ignition delay times by using ASTM E659 tester for 3-hexanone. The experimental AIT of 3-hexanone was at $425^{\circ}C$. The lower explosion limit( LEL) by the measured lower flash point of 3-hexanone was calculated as 1.21 Vol%.

Appropriateness of MSDS by Means of the Measurement of Combustible Properties of Anisole (아니솔의 연소특성치의 측정에 의한 MSDS의 적정성)

  • Ha, Dong-Myeong
    • Fire Science and Engineering
    • /
    • v.29 no.2
    • /
    • pp.20-24
    • /
    • 2015
  • For the safe handling of anisole, this study was investigated the explosion limits of anisole in the reference data. The flash points and auto-ignition temperatures (AITs) by ignition delay time were experimented. The lower flash points of Anisole by using closed-cup tester were experimented in $39^{\circ}C$ and $42^{\circ}C$. The lower flash points of Anisole by using open cup tester were experimented in $50^{\circ}C$ and $54^{\circ}C$. This study measured relationship between the AITs and the ignition delay times by using ASTM E659 tester for Anisole. The AIT of Anisole was experimented as $390^{\circ}C$. The lower explosion limit (LEL) by the measured the lower flash point for Anisole were calculated as 1.07 Vol%.

The Measurement of Combustible Properties of Cyclohexanol (사이클로헥산올의 연소특성치의 측정)

  • Ha, Dong-Myeong
    • Fire Science and Engineering
    • /
    • v.28 no.2
    • /
    • pp.64-68
    • /
    • 2014
  • For the safe handling of cyclohexanol, this study was investigated the explosion limits of cyclohexanol in the reference data. The flash points and auto-ignition temperatures (AITs) by ignition delay time were experimented. The lower flash points of cyclohexanol by using closed-cup tester were experimented in$60^{\circ}C{\sim}64^{\circ}C$. The lower flash points of cyclohexanol by using open cup tester were experimented in $66^{\circ}C{\sim}68^{\circ}C$. This study measured relationship between the AITs and the ignition delay times by using ASTM E659 tester for cyclohexanol. The AIT of cyclohexanol was experimented as $297^{\circ}C$. The lower explosion limit (LEL) and the upper explosion limit UEL) by the measured the lower flash point and the upper flash point of cyclohexanol were calculated as 0.95 Vol% and 10.7 Vol%, respectively.

A Study on the Reliability of the Combustible Properties for Acrylic Acid (아크릴릭산의 연소특성치의 신뢰성 연구)

  • Ha, Dong-Myeong
    • Journal of Energy Engineering
    • /
    • v.24 no.3
    • /
    • pp.20-26
    • /
    • 2015
  • For the reliability of the combustible properties of arylic acid, this study was investigated the explosion limits of acrylic acid in the reference data. The flash points and AITs(auto-ignition temperatures) by ignition delay time were experimented. The lower flash points of acrylic acid by using Setaflash and Pensky-Martens closed-cup testers were experimented in $48^{\circ}C$ and $51^{\circ}C$, respectively. The lower flash points of arylic acid by using Tag and Cleveland open cup testers were experimented in $56^{\circ}C$. This study measured relationship between the AITs and the ignition delay times by using ASTM E659 tester for acrylic acid. The AIT of acrylic acid was experimented as $417^{\circ}C$. The lower explosion limit(LEL) and the upper explosion limit(UEL) by the measured the lower flash point and the upper flash point of acrylic acid were calculated as 2.2 Vol% and 7.9 Vol%, respectively.

Modified Microwave Radio-thermometer for Measuring Temperature of Living Body (생체의 온도 측정을 위한 수정된 마이크로파 라디오-써모미터)

  • Kim Tae-Woo;Cho Tae-Kyung;Park Byoung-Soo
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.42 no.2 s.302
    • /
    • pp.27-32
    • /
    • 2005
  • This paper presents a modified microwave radio-thermometer (MRTM) with material characteristic estimator and multiple temperature conversion tables to measure subcutaneous temperature of a living body This estimator provides a temperature retrieval unit with the data of material characteristics such as permittivity, conductivity, thickness and geometry of the living body. The temperature retrieval unit with multiple temperature conversion tables can select one of the tables and computes temperature value corresponding to measured radiation power. In the experiments, it was shown that the MRTM could reduce measurement errors of about $0.82^{\circ}C\;to\;7.68^{\circ}C$ for the cases of distilled water and mixed liquid at the temperature of $37^{\circ}C$.

Development of experimental equipment for CVD processing model (CVD 공정모델 실험장치의 개발)

  • 정상범
    • Proceedings of the Korea Society for Simulation Conference
    • /
    • 2000.04a
    • /
    • pp.142-147
    • /
    • 2000
  • 본 연구의 주안점을 실험용 CVD 장치의 CVD 반응기 내에 투입된 기체의 농도와 온도를 즉시 측정하여 새로운 소자 개발 시에 공정모델 수립과 정밀도를 요하는 공정에서 증착량과 속도에 대한 데이터를 구하므로써 효율적인 CVD 장치를 구성하는 것으로서 실험실이나 연구소에서 정확한 CVD 공정모델 실험을 할 수 있게 하여 새로운 소자의 시뮬레이션 모델을 만들 수 있는 효과적인 성장방법의 개발을 통하여 원료기체의 효율적인 사용이 이루어지도록 반응기내에서 가스 및 온도제어 시스템을 개발하였다.

  • PDF

Measurement and Prediction of Combustion Properties of Styrene (스티렌의 연소특성치 측정 및 예측)

  • Ha, Dong-Myeong;Na, Byeong-Gyun
    • Journal of the Korean Institute of Gas
    • /
    • v.17 no.4
    • /
    • pp.70-76
    • /
    • 2013
  • For the safe handling of styrene, this study was investigated the explosion limits of styrene in the reference data. The flash points and AITs(auto-ignition temperatures) by ignition delay time were experimented. As a results, the lower and upper explosion limits of styrene recommended 0.9 Vol.% and 8.0 Vol.%, respectively. The lower flash points of styrene by using closed-cup tester were experimented $29^{\circ}C{\sim}31^{\circ}C$. The lower flash points of styrene by using open cup tester were experimented $32^{\circ}C{\sim}36^{\circ}C$. This study measured relationship between the AITs and the ignition delay times by using ASTM E659 tester for styrene. The experimental AIT of styrene was $460^{\circ}C$.