• Title/Summary/Keyword: 온도차시간제어

Search Result 70, Processing Time 0.027 seconds

Test methodology of acceleration life test on feeder cable assembly (Feeder Cable Assembly의 가속수명시험법 개발)

  • Han, Hyun Kak
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.8
    • /
    • pp.62-68
    • /
    • 2016
  • The feeder cable assembly is an automotive part used for telecommunication. If it malfunctions, the control and safety of the automobile can be put at risk. ALT (Accelerated Life Testing) is a testing process for products in which they are subjected to conditions (stress, strain, temperatures, etc.) in excess of their normal service parameters in an attempt to uncover faults and potential modes of failure in a short amount of time. Failure is caused by defects in the design, process, quality, or application of the part, and these defects are the underlying causes of failure or which initiate a process leading to failure. Thermal shock occurs when a thermal gradient causes different parts of an object to expand by different amounts. Thermal shock testing is performed to determine the ability of parts and components to withstand sudden changes in temperature. In this research, the main causes of failure of the feeder cable assembly were snapping, shorting and electro-pressure resistance failure. Using the Coffin-Manson model for ALT, the normal conditions were from Tmax = $80^{\circ}C$ to Tmin = $-40^{\circ}C$, the accelerated testing conditions were from Tmax = $120^{\circ}C$ to Tmin = $-60^{\circ}C$, the AF (Acceleration Factor) was 2.25 and the testing time was reduced from 1,000 cycles to 444 cycles. Using the Bxlife test, the number of samples was 5, the required life was B0.04%.10years, in the acceleration condition, 747 cycles were obtained. After the thermal shock test under different conditions, the feeder cable assembly was examined by a network analyzer and compared with the Weibull distribution modulus parameter. The results obtained showed good results in acceleration life test mode. For the same reliability rate, the testing time was decreased by a quarter using ALT.

Preparation of porous silica gel powders from sodium silicates

  • 장감용;전영관;임광일;이광희
    • Proceedings of the Korea Association of Crystal Growth Conference
    • /
    • 1996.06b
    • /
    • pp.29-53
    • /
    • 1996
  • 다공성 실리카 게 분말은 저밀도, 고비표면적의 특성을 가지며 물리적, 화학적 성질이 우수하여 필름의 점착방지제, 페인트의 소광제, 맥주의 흡착제, 촉매의 담지체등 산업전반에 걸쳐 여러용도로 사용되고 있다. 이러한 다공성 실리카 겔 분말은 고상법, 기상법, 액상법등으로 제조할 수 있으며, 이 중에서 sodium silicate를 원료로 하는 액상공정은 다공성의 제어가 용이하고, 공정이 간단하며, 고순도의 균질한 실리카를 얻을 수 있는 방법으로 많이 사용되고 있다. 본 연구에서는 액상법(sol-gel method)를 사용하여 점착방지제, 소광제 등으로 사용되는 다공성 실리카 겔 미분말의 개발에 초점을 두어 연구하였다. 그리고, 겔 분말의 다공성 제어를 위하여 공정 각 단계에서의 겔 내부의 구조의 변화에 대한 연구와 함께 수화겔의 숙성이 기공특성에 미치는 영향, 건조조건의 기공특성에 대한 영향 등을 살펴보았다. 다공성 실리카 겔 미분말은 다음과 같은 공정에 의해 제조되었다. sodium silicate를 황산과 반응시켜 겔화하고 추가의 황산을 투입하여 미반응분의 Na를 제거한 후 pH 7이상의 알카리 영역에서 숙성하여 다공성을 지닌 실리카 수화겔을 제조하였다. 수화겔의 탈수, 세척, 건조 공정을 거쳐 건조겔을 제조하고, 1-20$\mu\textrm{m}$의 크기로 분쇄하여 최종 제품을 얻을 수 있었다. 최종 다공성 실리카 겔 분말은 비표면적 200-700$m^2$/g, 기공부피 0.5-2.5cc/g, 평균 입경 3-5$\mu\textrm{m}$, 백색도 95% 이상의 물성을 보였다. sodium silicate와 황산의 겔화 반응에 의해 생성된 수화겔은 수 nm크기의 일차입자들의 연속적인 network로이루어져 있으며, 일차입자크기가 너무 작기 때문에 내부의 기공들은 별로 존재하지 않는 상태이다. 2차 주가황산 투입에 의해 미반응의 알카리 이온들을 중화, 제거시킬 수 있으며, 겔의 다공성을 좌우하는 숙성단계에서 숙성 pH, 온도, 시간등의 인자에 의해 수화겔의 기공특성을 제어할 수 있다. pH 7이상에서 실리카의 용해도가 크고, 용해도의 입자크기 의존성이 크므로, 일자입자는 Ostwald-ripening에 의해 계속 성장할 수 있으며, 이때, 입자의 성장은 숙성 온도와 시간에 의존한다. 탈수, 세척공정에 의해 가용성 염인 Na2SO4를 제거하고, 건조조건을 변화시킴으로써 기공부피를 증가시키는 것이 가능하였으며, Fast drying을 사용하여 점착방지제에 적합한 기공부피를 갖는 실리카 건조겔을 제조할 수 있었다.

  • PDF

Influence affected on the curvature radius of jar by circuit of cooling temperature and temperature control (냉온회로 및 제어가 JAR곡율반경에 미치는 영향)

  • Shin, Nam-Ho;Choi, Seok-Jong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.8 no.6
    • /
    • pp.1313-1318
    • /
    • 2007
  • When the mold is cooled suddenly to reduce the time for forming work and improve the quality of jar50ml which is different highly at rib thickness by a series of various curvature radii, the poor quality of void, flow and deformation happens. The structure of spiral cooling circuit at cavity and core can control the temperature of inner and outer side sufficiently. And the system can control cooling and heating automatically. These things are applied to Jar mold. and so, the best quality and the effect of productivity improvement can be obtained.

  • PDF

An Analysis of Unsteady 2-D Heat Transfer of the Thermal Stratification Flow inside Horizontal Pipe with Electrical Heat Tracing (Heat Tracing이 있는 수평배관 내부 열성층 유동의 비정상 2차원 열전달 해석)

  • 정일석;송우영
    • Journal of Energy Engineering
    • /
    • v.6 no.2
    • /
    • pp.119-128
    • /
    • 1997
  • A method to mitigate the thermal stratification flow of a horizontal pipe line is proposed by heating external bottom of the pipe with electrical heat tracing. Unsteady two dimensional model has been used to numerically investigate an effect of the external heating on the thermal stratification flow. The dimensionless governing equations are solved by using the control volume formulation and SIMPLE algorithm. Temperature distribution, streamline profile and Nusselt number distributions are analyzed under heating conditions. The numerical results of this study show that the maximum dimensionless temperature difference between hot and cold sections of the inner wall of pipe is 0.424 at dimensionless time of 1,500 and the thermal stratification phenomenon disappears at about dimensionless time of 9,000.

  • PDF

Study on Computational Fluid Dynamics(CFD) Simulation for De-NOx in the incinerator at Taebaek city (태백시 소각로 내 NOx 제거를 위한 전산유체역학(CFD) simulation 연구)

  • Kim, Ji-Hyun;Park, Young-Koo
    • Journal of the Korean Applied Science and Technology
    • /
    • v.30 no.2
    • /
    • pp.320-332
    • /
    • 2013
  • The feed air to MSW incinerator influences on the residence time of combustion gas, removal of unburnt ash and exiting gas temperature. Thus the secondary air volume could present sufficient residence time which can maintain the exiting temperature over $850^{\circ}C$. The secondary air also relates directly with the turbulence in the inside of combustion chamber, which finally provide the stable combustion condition. The present study designed a modern incinerator for a field scale, and evaluation of the potential amount of primary air based on the daily combustible quantity. From the evaluated primary air volume, the secondary air flow rate could be estimated, and its dynamic behavior was verified. In addition, the obtained air volume enables to find an optimum operation condition of the combustion. As a result of the CFD simulation, the air ratio 75 : 25 between primary and secondary air amount was optimum ratio than design criteria 72 : 28. And the flow velocity ratio of front-back of secondary air jet nozzle was found excellent at 1 : 3. In addition, the result of applied to the plant, the removal efficiency of NOx and CO generation would concentration of CO.

Analyses of Larg Cell Area MCFC System Dynamics (대면적 용융탄산염 연료전지 시스템 동특성 분석)

  • 강병삼;고준호;이충곤;임희천
    • Journal of Energy Engineering
    • /
    • v.8 no.4
    • /
    • pp.592-604
    • /
    • 1999
  • The steady state and dynamic characteristics of large cell area MCFC stacks were analyzed to solve the problems such as temperature difference generated in stacks and pressure difference between anode and cathode. Manipulated variables (current density, duel utilization rate, oxidant utilization rate) and controlled variables (temperature difference, anode and cathode pressure difference) which had an important effect on the MCFC stack performance were determined using operation results of two types of MCFC stacks (5kW (3,000 $\textrm{cm}^2$, 20 ea). 3kW (6,000 $\textrm{cm}^2$, 5ea)). The stability and transfer function representing system dynamics were obtained by steady state gain rate which showed the relative change between MVs and CVs. The transfer function was a 3$\times$3 matrix and a typical first order system without time delay. The optimal operating condition of large cell area MCFC stacks could be determined by analyzing dynamic characteristics. In case of a 5 kW MCFC stack, pressurized operation with recycle flow should be used to control the outlet temperature less than 68$0^{\circ}C$ and to control the MCFC system effectively. MIMO control or decoupler should be used to remove the interaction between MVs and CVs. This result will be used as important data in determining the control structure design and operation mode of large cell area MCFC systems in the future.

  • PDF

Development of Control Algorithm for Greenhouse Cooling Using Two-fluid Fogging System (이류체 포그 냉방시스템의 제어알고리즘 개발)

  • Nam, Sang-Woon;Kim, Young-Shik;Sung, In-Mo
    • Journal of Bio-Environment Control
    • /
    • v.22 no.2
    • /
    • pp.138-145
    • /
    • 2013
  • In order to develop the efficient control algorithm of the two-fluid fogging system, cooling experiments for the many different types of fogging cycles were conducted in tomato greenhouses. It showed that the cooling effect was 1.2 to $4.0^{\circ}C$ and the cooling efficiency was 8.2 to 32.9% on average. The cooling efficiency with fogging interval was highest in the case of the fogging cycle of 90 seconds. The cooling efficiency showed a tendency to increase as the fogging time increased and the stopping time decreased. As the spray rate of fog in the two-fluid fogging system increased, there was a tendency for the cooling efficiency to improve. However, as the inside air approaches its saturation level, even though the spray rate of fog increases, it does not lead to further evaporation. Thus, it can be inferred that increasing the spray rate of fog before the inside air reaches the saturation level could make higher the cooling efficiency. As cooling efficiency increases, the saturation deficit of inside air decreased and the difference between absolute humidity of inside and outside air increased. The more fog evaporated, the difference between absolute humidity of inside and outside air tended to increase and as the result, the discharge of vapor due to ventilation occurs more easily, which again lead to an increase in the evaporation rate and ultimately increase in the cooling efficiency. Regression analysis result on the saturation deficit of inside air showed that the fogging time needed to change of saturation deficit of $10g{\cdot}kg^{-1}$ was 120 seconds and stopping time was 60 seconds. But in order to decrease the amplitude of temperature and to increase the cooling efficiency, the fluctuation range of saturation deficit was set to $5g{\cdot}kg^{-1}$ and we decided that the fogging-stopping time of 60-30 seconds was more appropriate. Control types of two-fluid fogging systems were classified as computer control or simple control, and their control algorithms were derived. We recommend that if the two-fluid fogging system is controlled by manipulating only the set point of temperature, humidity, and on-off time, it would be best to set up the on-off time at 60-30 seconds in time control, the lower limit of air temperature at 30 to $32^{\circ}C$ and the upper limit of relative humidity at 85 to 90%.

Mushroom growth and cultivation environment at cultivation house of vinyl bag cultivation Shiitake mushroom on high-temperature period (고온기 표고 톱밥재배용 재배사 내의 환경 제어시스템과 버섯생육 온도)

  • Jhune, Chang-Sung;Kong, Won Sik;Park, Hye-Sung;Cho, Jae-Han;Lee, Kang-Hyo
    • Journal of Mushroom
    • /
    • v.12 no.4
    • /
    • pp.263-269
    • /
    • 2014
  • Although sawdust cultivation of shiitake (Lentinula edodes) is becoming more common, it is insufficiently competitive in spring and autumn, the best time to breed shiitake. Thus, it is urgently needed to develop a technique for all year round cultivation of shiitake using mushroom growing beds. In the present study, the temperature changes according to the location of shiitake cultivation facilities were investigated. We confirmed that a refrigerator, an air conditioner, triple membranes, shiitake cultivation beds, fog nozzles which were installed in the shiitake cultivation facilities play an important role in keeping the low temperature. Bag cultivation of shiitake was tested in temperature variation from $14^{\circ}C$ to $29^{\circ}C$ with a $3^{\circ}C$ interval to know its cultivating temperature range in hot summer season. In summary, the sawdust cultivation of shiitake is possible when the temperature difference between top and bottom is maintained below $1^{\circ}C$. And the temperature of the shiitake cultivation facilities should be maintained below $23^{\circ}C$ in the induction period for fruitbody formation.

A Method to Acquire Bigdata for Predicting Accidents on Power Switchboards (배전반 안전사고 예측을 위한 빅데이터 자료 획득 방안)

  • Lee, Hyeon Sup;Kim, Jin-Deog
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2021.10a
    • /
    • pp.351-353
    • /
    • 2021
  • In recent years, while the demand for electricity is rapidly increasing, fire accidents due to negligence in management of switchboards. In particular, switchboards for industrial and electrical resource control can cause serious problems. Thus, for the safety management of power switchboard, a secondary response is conducted to control firing when a specific condition value is satisfied, but in this case, it is highly likely that a considerable amount of time has elapsed after firing. In this paper, we propose a method to acquire big data for the development of a switchboard temperature and power control system that can actively respond to the current situation by monitoring and learning the temperature of the switchboard's busbar connection in real time. Specifically, a method for periodically acquiring and managing data such as temperature and power from various scattered sensors is proposed.

  • PDF

Design of New LED Operation Drive Using Compensating Circuit for Transformed Voltage (전압 변동분 보상이 가능한 새로운 LED 구동드라이브 설계)

  • Yang, Hee Won;Lee, Sang Hun;Park, Sung Jun
    • Proceedings of the KIPE Conference
    • /
    • 2011.07a
    • /
    • pp.30-31
    • /
    • 2011
  • 현재의 고출력 LED (Light Emitting Diode)는 긴 수명시간, 적은 유지보수 비용, 그리고 고효율의 특징으로 차세대 조명 소자로 각광받고 있다. 본 논문에서는 Two-stage LED 구동 회로에서 온도 변화에 따른 정전류 제어가 가능한 LED 구동 드라이브의 효율을 개선하기 위해 입력 전압을 기본 전압으로 하고 LED 출력전류를 통한 전압 변동분 만을 전력변환하여 보상 할 수 있는 LED 구동 드라이브 회로를 연구 하였다. 제안된 비절연 전압 변동분 보상회로는 기존 DC/DC 컨버터를 이용한 LED 구동 드라이브에 비해 효율이 개선 되었음을 실험을 통해 알 수 있었다.

  • PDF