• Title/Summary/Keyword: 온도차시간제어

Search Result 70, Processing Time 0.023 seconds

Development of Temperature Controlled Impulse Sealer for Preventing Cumulative Heat and Improving Sealing Quality (누적열 방지 및 비닐 접착품질 향상을 위한 온도 제어형 임펄스 씰러 (Impulse Sealer)의 개발)

  • Kim, Insoo;Kim, Sung Min;Seo, Jongchul
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.25 no.3
    • /
    • pp.117-123
    • /
    • 2019
  • The general Impulse Sealer has a problem of sealing quality because continuously sealing process results in an undesirable temperature rise, which may accumulate the heat during the operation. In order to address such a drawback, the controlled sealing temperature method can be effectively utilized compared with the general controlled time method. As such, a temperature sensor with capability of detecting the sealing temperature was installed, and a separate PCB was manufactured to control the sealing temperature by measuring and calculating the detected temperature. The temperature changes during the temperature rise and maximum temperature after continuously operation were investigated using an Impulse Sealer system. Next, the results obtained from experiment were compared with each other. As such, the maximum temperature was 70.3℃, whereas 8.9℃ was recorded as control temperature. It implies that this controlled temperature system prevented the undesirable temperature rise, thereby causing a consistent sealing quality.

A New Temperature Control System by PWM Control Method for Thermal Massage System (PWM 제어방식에 의한 온열치료기의 새로운 온도제어 시스템)

  • Song, Myoung-Gyu;Lee, Jae-Heung
    • Journal of IKEEE
    • /
    • v.18 no.3
    • /
    • pp.409-419
    • /
    • 2014
  • This paper proposes a new temperature control algorithm and system configuration of the pTMS(personal Thermal Massage System). By controlling the pulse width of the PWM(Pulse Width Modulation), the temparature of the heating lamp can be controlled stably, which is indispensable to the massage function. This technology is also adapted to the 'thermal massage', 'thermal acupressure', 'thermal moxibustion' functions of medical equipments. The temperature could be set at between $40^{\circ}C{\sim}70^{\circ}C$ by increments of $5^{\circ}C$, the control could be made in real time by increments of $1^{\circ}C$, and the temperature is displayed on the monitor by triggering every 2 seconds. when the present temperature is equal to the preset temperature, the PWM signal is minimized, and when the present temperature is higher than the preset temperature, overheating is prevented by interrupting the PWM output signal. When the difference of temperature exceeds $4^{\circ}C$, the PWM control is maximized in order for the system to reach the target temperature within a short period of time.

Field Cooling Tests of Paddy Stored in Steel Bins with a Grain Cooler (곡물냉각기를 이용한 철제 원형빈에서 벼 냉각)

  • 김의웅;김동철
    • Food Science and Preservation
    • /
    • v.11 no.2
    • /
    • pp.263-268
    • /
    • 2004
  • Two field cooling tests were conducted to evaluate the cooling characteristic of paddy with a prototype grain cooler. The first test was carried out during summer season in a steel bin with 180.3ton of paddy at Sunchon. And the second test was carried out during harvesting season in a steel bin with 272.2ton of paddy at Ulsan. At the first test, initial paddy temperature of 23.6$^{\circ}C$ was dropped to 14$^{\circ}C$, and initial moisture content of 19.9% was dropped to 19.3% after 52.5 hours of cooling. At the second test, initial paddy temperature of 16.1$^{\circ}C$ dropped to 5.5$^{\circ}C$ after 78.0 hours of cooling. And, at the first test, the average air flow rates of chilled air leaving the grain cooler and penetrating the grain layer were 77.5 ㎥/min and 42.5 ㎥/min, respectively. To prevent leakage of chilled air from plenum chamber of steel bin, which was about 45% of the average air flow rates of chilled air leaving the grain cooler, a proper method was required. The average total power consumption at the first test during summer was 22.1 ㎾ with control of fan damper. At the second test, it was 17.4 ㎾ due to controlling the capacity of compressor with unloading solenoid valve and changing the flow rates of hot refrigerant gas flowing into evaporator and reheater from compressor, resulting in 27% reduction of energy consumption.

$OP\DeltaT/OT\DeltaT$ 응답시간 시정수 변화에 따른 영향 분석

  • 윤덕주
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1998.05a
    • /
    • pp.221-226
    • /
    • 1998
  • 과잉온도 차온(Overtemperature $\Delta$T) 및 과잉출력 차온(Overpower $\Delta$T)트립에 쓰이는 온도 측정계통 총 지연시간은 6초로 구성되며 RTD 우회배관 제거시 4.5초의 RTD 응답시간(일차지연 상수로 가정)과 1.5초의 순수지연시간(전자회로 지연시간 + 그립퍼 풀림시간등)으로 구성된다. 그러나 RTD우회배관 제거전 사고분석을 일차지연상수를 3.5초, 순수지연을 2.5초로 모델링하였으므로 Simulink를 통한 영향분석과 Rack 응답시험 계단파 입력신호의 타당성을 평가하였다. RTD 응답시간은 전형적인 1차 지연요소로 나타내며 계전기나 제어봉 Gripper Release 시간 등은 순수 지연으로 가정하고 분석을 수행하고 기타 지연/지상 필터를 발전소와 동일하게 모델링하여 분석하므로써 발전소에서 일어나는 과도현상을 묘사할 수 있다는 점을 고려할 때 RTD우회배관 제거후 응답시간 지연상수가 바뀌더라도 안전하다는 결론에 도달했다.

  • PDF

Characteristics of Heat Transfer in a Heat pipe Controlled by Solenoid Valve (전자 밸브에 의해서 제어되는 히트파이프의 전열 특성)

  • Jun, C.H.;Jang, Y.S.;Kim, O.G.
    • Solar Energy
    • /
    • v.17 no.1
    • /
    • pp.103-111
    • /
    • 1997
  • The purpose of this research is the study of characteristics of heat transfer in a heat pipe controlled by solenoid valve. A solenoid valve located to the adiabatic section between evaporator and condenser of heat pipe was used to control the valve action for effective energy transfer of the industrial exchanger machine. By the results presented in this study temperature difference between evaporator and condenser increases with increasing the temperature frequency and with decreasing the temperature amplitude. When inclination angle and flow rate of cooling water increases, the temperature amplitude is reached to the steady state rapidly with increasing the temperature frequncy.

  • PDF

A Study on Thermal Heating Control Performance of Automatic Thermostatic Valves in Floor Radiant Heating System (바닥난방 시스템의 열환경 개선을 위한 제어방안 연구)

  • Song, Jae-Yeob;Ahn, Byung-Cheon;Kim, Kyung-Chul;Jang, Sa-Yun
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.973-978
    • /
    • 2009
  • In this study, the thermal environment characteristics of On-Off control and thermal difference proportional control method in floor radiant heating system were researched by computer simulation. For the analysis of unsteady heat transfer phenomena in household, the method of using electrical equivalent R-C circuit is applied, and radiation heat transfer between panel, ceiling and walls in household is calculated by enclosure analysis method. The parametric study on two control methods, conventional on-off control and temperature error based time control(T.E.B.T.C.) method, are performed to compare thermal heating control performances, respectively.

  • PDF

Influence of Heat Treatment Conditions on Temperature Control Parameter ((t1) for Shape Memory Alloy (SMA) Actuator in Nucleoplasty (수핵성형술용 형상기억합금(SMA) 액추에이터 와이어의 열처리 조건 변화가 온도제어 파라미터(t1)에 미치는 영향)

  • Oh, Dong-Joon;Kim, Cheol-Woong;Yang, Young-Gyu;Kim, Tae-Young;Kim, Jay-Jung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.5
    • /
    • pp.619-628
    • /
    • 2010
  • Shape Memory Alloy (SMA) has recently received attention in developing implantable surgical equipments and it is expected to lead the future medical device market by adequately imitating surgeons' flexible and delicate hand movement. However, SMA actuators have not been used widely because of their nonlinear behavior called hysteresis, which makes their control difficult. Hence, we propose a parameter, $t_1$, which is necessary for temperature control, by analyzing the open-loop step response between current and temperature and by comparing it with the values of linear differential equations. $t_1$ is a pole of the transfer function in the invariant linear model in which the input and output are current and temperature, respectively; hence, $t_1$ is found to be related to the state variable used for temperature control. When considering the parameter under heat treatment conditions, $T_{max}$ was found to assume the lowest value, and $t_1$ was irrelevant to the heat treatment.

The Characteristic Refinement of Poly-Si by Uni-directional Solidification with Thermal Gradient (일방향 응고시 온도 구배에 의한 다결정 실리콘 정련 특성)

  • Jang, Eunsu;Yu, Joon-Il;Park, Dongho;Moon, Byungmoon;Yu, Tae U
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.59.2-59.2
    • /
    • 2010
  • 결정형 태양 전지의 보급화를 위하여 고순도 실리콘을 저렴하게 제조할 수 있는 기술 개발이 필요하다. 본 연구에서는 고순도 실리콘을 경제적으로 제조하기 위하여 대역 정제에 의한 일방향성 응고법을 이용한 정련 연구를 진행하였으며, 응고 속도와 고 액상의 온도 구배가 정련도에 미치는 영향을 분석 하였다. 본 실험에 사용된 일방향 응고장치는 실리콘 용탕이 장입된 도가니 하부의 열 교환기를 통한 냉각에 의해 용탕 하부에서 상부 방향으로의 일방향성 응고가 진행되며, 응고 진행시 용탕의 흔들림에 의한 정련능의 감소를 방지하기 위해 가열 영역이 이동하는 Stober 공정을 채택하였다. 가열 영역은 실리콘 용융을 위한 상부 가열 영역과 응고 진행시 응고부의 온도 제어를 위한 하부 가열 영역으로 구성되어 있으며, 두 가열 영역의 온도 제어를 통해 응고중인 실리콘의 고 액상의 온도 구배를 조절하였다. 일방향 응고에 의한 정련법에서 고 액상의 온도 구배가 증가할수록 2차 수지상의 발달이 감소하고, 주상정의 수지상 형태를 유지하게 되어 고 액 공존영역에서 액상 영역으로의 확산이 원활하게 이루어져 분배계수를 이용한 정련도가 좋아지게 되며, ICP 분석을 통해 온도 구배의 증가에 따라 정련능이 증가하는 양상을 확인 할 수 있었다. 고 액상의 온도 구배의 조절을 통한 공정 시간 대비 정련도의 향상을 통해 결정형 태양전지의 생산성의 증가를 통한 저가화를 이룰 수 있을 것이다.

  • PDF

Simulation Study for Control Strategies of Indoor Air Temperature in Floor Radiant Heating System (바닥 복사난방 시스템의 실내온도 제어방안에 관한 시뮬레이션 연구)

  • Song, Jae-Yeob;Ahn, Byung-Cheon
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.12 no.4
    • /
    • pp.21-26
    • /
    • 2016
  • In this study, the control strategies of indoor air temperature in floor radiant heating system were researched by computer simulation. The temperature difference based time control method using the difference of indoor set temperature and indoor temperature is compared with the existing On-Off control one for heating control performances. As a result, the temperature difference based time control method shows better thermal environmental characteristics in case of selected operational conditions in comparison with existing control one.

The design and simulation of PID controller for primary air applied to operating data (운전데이터를 이용한 보일러 연소공기용 제어기 설계 및 시뮬레이션)

  • 이찬주
    • Proceedings of the Korea Society for Simulation Conference
    • /
    • 1999.10a
    • /
    • pp.35-40
    • /
    • 1999
  • PID 제어기를 이용한 피드백 제어가 공정 제어에 도입된 이래로 PID 제어 알고리즘 및 적정 파라미터 계산에 대한 연구가 계속 진행되어 왔다. 일반적으로 PID 제어기 파라미터는 제어대상 프로세스의 1차 시간지연 모델로 근사화 하여 계산하는 방법과 임계이득 및 임계주파수를 구하여 계산하는 방법이 있다. 본 논문에서는 먼저 발전플랜트의 변수들 사이의 인과관계를 표현하는 신호 흐름도와 현장에서 취득한 데이터를 이용한 보일러 온도제어 계통의 모델링 및 제어기의 구성에 관하여 기술하고자 한다. 이러한 현장 운전 데이터에 의해 산출된 프로세스 모델을 이용하여 임계이득 및 임계주파수에 의한 PI 제어기의 적정 파라미터를 구하고, PI 제어기에 현장 데이터를 입력하여 컴퓨터 시뮬레이션 함으로써 프로세스 모델 및 PI 제어기의 성능을 검증하고자 한다.

  • PDF