• Title/Summary/Keyword: 온도저감효과

Search Result 314, Processing Time 0.026 seconds

A study on the use of fire hydrants as a heat wave reduction facility through hydraulic analysis of water supply network (상수관망 수리해석을 통한 폭염 저감 시설로써의 소화전 활용방안연구)

  • Hong, Sung Jin;Choi, Doo Yong;Yoo, Do Guen
    • Journal of Korea Water Resources Association
    • /
    • v.54 no.12
    • /
    • pp.1215-1222
    • /
    • 2021
  • In this study, a study on how to use a fire hydrant as a heat wave reduction facility through hydraulic analysis of the water supply pipe network was conducted. Assuming that the fire hydrant installation point is open for heat wave reduction, the water pressure at each point was derived. And the reduction rate of the temperature according to the hydrant watering was compared with the watering area according to the operation of the watering truck. The watering area according to the opening of the fire hydrant was calculated by deriving the pressure value at the node where the fire hydrant was installed through hydraulic analysis of the water pipe network, and then using the watering radius relational expression according to the pressure value. As a result of applying the proposed methodology to two real city areas, the temperature reduction effect of the watering method by a fire hydrant can be derived lower than the watering method by a watering truck according to the difference in the absolute watering area. However, unlike a watering truck, a fire hydrant does not have a relative restriction on the amount of water supply and is expected to allows continuous divided spraying of the same area.

Analysis of carbon reduction effect of efficient water distribution through intelligent water management (지능형 물관리를 통한 효율적인 물분배의 탄소저감 효과 분석)

  • Ha Yong Kim
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.436-436
    • /
    • 2023
  • 산업혁명을 거치면서 높은 화석연료를 사용하는 제조업 중심의 산업구조와 많은 자원을 필요로 하는 도시의 집중 현상으로 지구 온난화에 따른 이상기후 발생이 증가하고 있다. 이러한 기후변화는 홍수, 태풍, 폭염 및 폭설 등의 자연재해 발생 빈도 및 규모를 증가시켜 피해가 커지고 있다. 특히 인구 및 시설들이 집중해 있어 도시의 집중 현상은 이러한 재해에 더욱 취약한 구조가 됨에 따라 피해의 규모를 가중 시키고 있는 실정이다. 전 세계적으로 기후변화 문제의 심각성을 인식하고 이를 해결하기 위해 선신국에 의무를 부여하는 교토의정서(1997년) 채택에 이어, 선진국과 개도국이 모두 참여하는 파리협정(2015년)을 채택하였고 2016년 협정이 발효되었다. 파리협정의 목표는 산업화 이전 대비 지구 평균온도 상승을 2℃보다 아래로 유지하고, 나아가 1.5℃로 억제하기 노력하는 것을 강제하는 것으로 2050년까지 탄소 순배출량을 '0'으로 만든다는 탄소중립사회로의 전환이 본격적으로 시작되었다. 본 연구에서는 기후변화로 인한 물부족 및 수실오염과 같은 도시의 수자원 문제 해결을 위해 IoT 기반 센서 및 네트워크 기반 수자원 플랫폼을 개발하였다. 도시 수자원 시설 데이터를 기반으로 대체 수자원 확보 및 수요 중심의 물 관리를 통해 효율적인 물 배분이 될 수 있도록 하였으며 이러한 스마트 물 관리에 따른 대체 수자원 확보 및 효율적 물 배분이 탄소 저감에 미치는 효과에 대해 분석하였다. 연구대상 지역은 세종 6-4구역으로 LID 특화지구로 조성되었으며 1,000 세대의 주민이 생활하는 공동주택이다. 물 순환(LID) 시설에서 확보된 물을 물 공급 시설과 연계하여 공동주택에서 활용함으로써 감소된 상수 사용량을 온실가스 배출량으로 환산하여 탄소 저감량을 계산하였다. 실제 주민들(1,000세대)이 사용하고 있는 상수량 데이터와 전력거래소 온실가스 배출계수를 활용하였으며 물순환(LID) 시설로 확보하여 대체할 수 있는 상수량은 10%로 가정하였다. 연구대상 지역(1,000세대)의 연간 상수공급량은 331,603m3이며, 연간 전력사용량은69,637kWh이다. 온실가스 배출량은 31.963tCO2eq이며, 온실가스 저감량은 3.2tCO2eq로 산정되었다. 추후 LID 시설에 대한 상수 대체량과 온실가스 저감효과 정량화가 필요하다.

  • PDF

Improvement of DeNOx efficiency of SNCR Process with Chemical Additives in Urea Soution (환원제로 우레아를 사용하는 SNCR 공정에서 첨가제 적용에 따른 탈질효율 향상 연구)

  • Yoo, Kyung Seun;Park, Sung Woo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.10
    • /
    • pp.663-668
    • /
    • 2017
  • Dye waste water generated in the dye industry is categorized as hazardous waste water that requires appropriate treatment. The pilot scale experimental trials were carried out using dye waste water as an effective additive for the selective non-catalytic reduction (SNCR) of NOx in combustion flue gases. The additives were waste liquor obtained from the dye industry and several purification steps were taken to make a standardized reagents. The dye waste water was shown to possess valuable SNCR qualities (at least 87% NOx reduction efficiency) considering its availability as a waste product, which has to be strictly treated, and have little effects on CO removal. The results indicated that the NO removal efficiency increased first and then decreased with increasing temperature within $750-1150^{\circ}C$. The maximum NO reduction efficiency was approximately 87% at the optimal reaction temperature. A more than 10% increase in NO reduction was achieved in the presence of 1000 ppm Na-additives (dye waste water) compared to that without additives. The Na-based additives have also a significant promoting effect on $N_2O$ reduction and within the SNCR temperature window.

Characteristics of NOx Reduction and NH3 Slip in SNCR Using Pipe Nozzle for the Application of Hybrid SNCR/SCR Process (Hybrid SNCR/SCR 탈질공정에서 SNCR의 관통노즐에 의한 NOx 저감 및 NH3 Slip 특성)

  • Hyun, Ju Soo
    • Korean Chemical Engineering Research
    • /
    • v.47 no.1
    • /
    • pp.111-118
    • /
    • 2009
  • A hybrid SNCR/SCR plant was designed and manufactured, and experimented on the SNCR process in the first step to investigate the optimum operation conditions of SNCR, with the equivalence ratio of the reducing agent(NSR, 0.5~5.0), reaction temperature($850{\sim}1,100^{\circ}C$), nozzle type(wall nozzle, pipe nozzle), and nozzle position as variables. In the case of wall nozzles, the NOx reduction efficiency rapidly increased to 87% at 2.5 NSR and slowed down after this. Compared to the upward spray from the pipe nozzle, wall nozzles have narrower range of applicable reaction temperature. In the case of pipe nozzles, it rapidly increased to 77% at 1.5 NSR. But the pipe nozzle downward had no NOx reduction efficiency; on the contrary, NOx increased. When the reducing agent was sprayed upward from a pipe nozzle, the NOx reduction efficiency was 50~75% in the range of 0.5~1.5 NSR, and the NOx reduction efficiency was constant without fluctuations even in the change of reaction temperature from 890 to $1,000^{\circ}C$. When 5% urea solution was sprayed upward from the pipe nozzle, 200 ppm NOx decreased to approximately 60 ppm at 1.2 NSR, and the non-reacted $NH_3$ was 50~100 ppm. In this condition, we expect over 90% NOx reduction efficiency without additional supply of $NH_3$ to SCR at the back of SNCR.

Improvement of Katsuobushi smoking machine for the reduction of benzo(a)pyrene (가쓰오부시 훈연기 개선 및 벤조피렌 저감화)

  • Hong, Ju Hee;Hwang, Sang Min;Lee, Seung Ju
    • Korean Journal of Food Science and Technology
    • /
    • v.49 no.2
    • /
    • pp.162-167
    • /
    • 2017
  • A Katsuobushi smoking machine was developed and evaluated to determine its benzo(a)pyrene reducing effect. The machine was equipped with two heaters for smoking and chamber heating. The smoke-generating system was equipped with a cadmium sulfide (CdS) smoke sensor, an on/off controller, and a rotating feeder with a smoke inlet. Raw bonito was steamed and then smoked under three smoke levels. After smoking at $45^{\circ}C$ for 108 h, the benzo(a)pyrene concentrations were 5.87, 7.83, and $11.41{\mu}g/kg$ at the low, middle, and high smoke levels, respectively. The benzo(a)pyrene concentrations after low-level smoking at 45, 65, and $85^{\circ}C$ for 108 h were 5.87, 4.82, and $3.27{\mu}g/kg$, respectively. Accordingly, the optimal conditions for benzo(a)pyrene reduction were a lower smoke level and higher smoking temperature. These optimal smoking conditions can be implemented with the newly developed machine, but is not possible using a conventional Katsuobushi smoking machine.

기고 - 기후가 변화하면. 조경수종은 어떻게 변화할까?

  • Heo, Gyeong-Tae
    • Landscaping Tree
    • /
    • s.111
    • /
    • pp.8-9
    • /
    • 2009
  • 지구 평균 기온은 이미 19세기 비하여 0.75$^{\circ}C$ 상승해 있는 상태이며, 이 시점에서 화석연료를 사용하는 모든 스위치를 내린다 해도 앞으로 지구의 온도는 추가로 0.6$^{\circ}C$ 상승할 거이라고 한다. 왜냐하면 우리가 이미 대기 중에 방출해 놓은 온실가스의 온난화 효과가 시간차를 두고 나타나기 때문이다. 그러나 현실적으로 화석연료를 사용하는 스위치를 내려 놓을 수도 없고, 획기적 탄소 저감 기술이 없다면 당분간은 대기중에 온실가스의 배출량은 줄이지 못할 것이라는데 이의가 없다. 따라서 온난화 효과는 가속화되고 기온은 계속 상승할 것이라는 것은 쉽게 예측할 수 있다. 더구나 최근 우리나라는 세계 평균 기온상승에 비하여 2배의 높은 수치를 보인다.

  • PDF

Analysis of the Heating and Cooling Energy Load of the KNU Plant Factory with Single Skin Windows (단일창호를 적용한 KNU 식물공장의 냉난방 에너지 부하 해석)

  • Lee, Chan-Kyu;Kim, Woo-Tae
    • Proceedings of the KAIS Fall Conference
    • /
    • 2012.05b
    • /
    • pp.575-578
    • /
    • 2012
  • 단일창호를 적용한 KNU 식물공장 모델의 냉난방 에너지 부하를 DesignBuilder를 이용하여 해석하였다. 상추의 적정생육온도인 $20^{\circ}C$를 기준으로 이중창호를 적용한 경우와 에너지 소모량을 비교 분석하였다. 단일창호가 이중창호에 비해 연간 냉방부하는 약 128 MWh 감소하고 난방부하는 약 26 MWh 증가하여 단일창호가 냉방부하저감에 유리하다고 판단된다. KNU 식물공장의 중앙에 위치한 공간의 상부를 지붕구조물로 닫거나 계절별로 개폐하면서 냉난방부하에 미치는 영향을 계산하였다. 지붕구조물을 설치하게 되면 단위유닛이 취득하는 태양열이 감소하여 냉방부하가 감소하게 된다. 또한 지붕구조물을 상시 닫아두는 것이 계절별로 여닫는 것보다 냉방부하 저감에 유리하다. 식물공장 측면벽에 overhang과 sidefin을 설치하면 차양효과로 냉방부하가 감소하지만 감소비율은 크지 않았다. 에너지 부하의 대부분을 차지하는 냉방부하를 낮추기 위해 구조물이나 차양을 설치할 수 있으나 절감효과에 비해 설치비가 증가할 수 있기 때문에 추가 경제성 연구가 필요하다.

  • PDF

A Study on the Development of Model and Application Case of Water Screen Effect for Fire Behavior Simulation in Road Tunnel (도로터널 화재성상 시뮬레이션을 위한 워터스크린 효과 모델개발 및 적용사례)

  • Han, Jung-Chul;Kim, Se-Jong;Kim, Dong-Eun;Kurioka, Hitishi;Ootuki, Masato;Kwon, Young-Jin
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.04a
    • /
    • pp.83-88
    • /
    • 2011
  • 워터스크린(이하 W/S)에 의한 화재방화시스템은 도로터널에 화재가 발생시, 공간에 수막을 사용하여 구획화하고, 열 연기의 확산을 억제하며 유해 부유입자를 세정함으로서 인간의 안전을 확보 및 구조물의 피해를 극소화 하는 시스템이다. 이 W/S에 의한 구획의 성능을 평가하기 위해, 1/2의 터널 모형에 의한 공간 내 열 성장 파악을 위한 화재 실험을 분석하였고, 그 결과, 천정 근방 온도 및 방사수열량으로서는 발열 속도의 크기, 풍속의 대소에 의하지 않고 약 80%의 저감율을 나타냈다. 또, 발생한 유해 부유입자 농도에 대해서는 약 60%, 화원 성질과 상태로서 발열 속도는 약30%의 W/S에 의한 저감 효과를 나타내었다.

  • PDF

Material Properties and Shrinkage Crack Resistance of Concrete Produced with Fluorine-Silicate Hybrid Type Crack Reducing Agent (불소-실리카 복합형 균열저감제가 첨가된 콘크리트의 재료 특성과 수축균열 저항성)

  • Lee, Man-Ik;Park, Jong-Hwa;Nam, Jae-Hyun;Kim, Do-Su;Kim, Jae-On
    • Journal of the Korea Concrete Institute
    • /
    • v.18 no.4 s.94
    • /
    • pp.553-558
    • /
    • 2006
  • In this study, fluorine-silicate hybrid type crack reducing agent(FS) consisted of fluorine and silicate compounds applied to concrete mix(specification : 25-30-18) between 0.5% and 2.0% at intervals of 0.5% based on cement weight. Experiments for material properties of concrete such as slump, air content and bleeding with elapsed time were performed. Experiment and elucidation for shrinkage crack resistance as well as adiabatic hydration temperature were also carried out. It was appeared that FS addition contributed to lower bleeding and hydration temperature without disturbance of fresh properties of concrete such as slump and air content compared to non-added concrete. Especially, shrinkage crack resistance of concrete resulted from plastic and drying shrinkage could be effectively reduced by the addition of FS ranging from 1.0% to 1.5%.

A thermal-flow analysis of deaerator floor of power plant for reducing the radiative heat transfer effect (발전소 Deaerator floor의 복사효과 저감을 위한 열유동 해석)

  • Kim, Tae-Kwon;Ha, Ji-Soo;Choi, Yong-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.12
    • /
    • pp.476-481
    • /
    • 2016
  • Steam power generation is used to produce electricity through a generator that is connected to a steam turbine. As a result, the surface temperature of the deaerator is $70^{\circ}C$during the summer season, the surface temperature of the storage tank is $67^{\circ}C$, and the air temperature is $50^{\circ}C$. This environment is inappropriate for workers and instruments. Workers adjacent to the deaerator and storage tank in particular feel higher temperatures because of the radiative heat transfer effect. Therefore, we optimized the cooling conditions by computational analysis. Case 1 is the current shape of the power plant, Case 2 has additional insulation, and Case 3 has a radiation shield. Flow is caused by a temperature difference between the heat sources in the wall, and hot air is trapped in the right upper end. Based on the temperature contours and the maximum temperature of the surfaces, Case 2 was found to be the most efficient for reducing radiative heat transfer effects.