• Title/Summary/Keyword: 온도성층화

Search Result 72, Processing Time 0.04 seconds

IMPROVEMENT OF FRESHENING PROCESS BY MEANS OF UNDERDRAINAGE CONDUIT (저층배수를 이용한 담수호화 촉진에 관한 연구)

  • 서영제;김진규
    • Water for future
    • /
    • v.25 no.1
    • /
    • pp.111-119
    • /
    • 1992
  • This paper is concerned with the actual comparison analysis for the freshening process in the two selected experimental reservoirs. At the deep freshening reservoir, the salinity and depth of the freshwater layer were estimated by simulation technique using the quantitative equation for the two-layered flow structures. First of all, it is shown that the effects of underdrainage conduit in the lower layer were reported more effective for the control of upper layer salinity comparing with the case of no underdrainage conduit. Further the results of computation were later compared with the real observed values and the relating parameters of the salt-balance equation are conformed even though approximately. Finally it was represented that the salinity of upper layer is easily diluted not only by the tidal gate but also by the underdrainge conduit in the lower layer of the freshening reservoir.

  • PDF

바닥 급기 공조의 전망

  • 김영일
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.30 no.8
    • /
    • pp.54-59
    • /
    • 2001
  • 바낙 공기 급기(UFAD, underfloor air distribution)는 사무실과 상업 건물의 공조를 위하여 바닥 하부 공간을 사용하는 혁신적인 기술이다. 북미에서는 UFAD가 기존 천장 공기 급기 방식에 비하여 많은 장점을 지니므로 그 수요가 날로 증가하고 있다. 잘 설계된 UFAD 시스템은 다음과 같은 장점을 지닌다. - 건물의 용도 변경에 따픈 유연성이 우수하므로 건물의 생애 주기 비용을 감소시킨다. - 개별 쾌적성 제어가 가능하므로 온열 쾌적성, 거주자의 만족도 그리고 생산성을 향상시킨다. - 거주자주변에 직접 선선한 공기를 공급하므로 환기 효율, 실내 공기질 그리고 건강 상태를 향상시킨다. - 이코노마이저 운전, 온도 성층화 그리고 낮은 정합 운전에 의하여 에너지 비용을 감소시킨다. - 설비 공간이 축소되고 표준 철골 구조에서는 콘크리트 구조체 변경이 가능하므로 새 건축 공법에서는 충고를 감소시킬 수 있다. 1995년까지만 해도 UFAD는 파격적인 설계 기법이라고 여겨졌지만, 이제 설계자와 건축업자들은 2004년까지 신축되는 사무용 건축품의 35%는 바닥을 높인 기법이 적용되며 이 중 반 정도가 UFAD를 채택할 것이라고 예측하고 있다. 2000년 2억불이라고 추정되던 바닥을 높이는 건축의 시장 규모가 2004년에는 최소 10억불이 되리라고 예측된다. UFAD는 기본 연구에 의한 정립된 표준화된 설계 기법과 지침이 아직 마련되지 않았음에도 불구하고 현재 설계, 시공되고 있다. 이라한 경향은 펄수적인 연구가 수행되어 관련 업계가 지식과 경험을 충분히 쌓기 전까지는 계속될 전망이다. 본고는 시스템 설계와 운영의 주요한 특징, 기존 방식과 비교하여 지니고 있는 잠재적인 장점, 한계와 기술 개발의 필요성, UFAD 기술 개발을 위하여 계속적으로 요구되는 연구 분야 등을 서술함으로써 현재 UFAD 기술에 대한 평가를 한다.

  • PDF

A Study on the Water Quality Variation Characteristics of Nakdong River Considering the Meteorological Effects (기상학적 영향을 고려한 낙동강 유역 수질변동특성 연구)

  • Jung, Woo Suk;Kim, Young Do
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2019.05a
    • /
    • pp.422-422
    • /
    • 2019
  • 최근 낙동강유역에서는 여름철 폭염 및 가뭄의 영향으로 조류대경보가 발령되고 있으며, 급격한 수질환경적 변화가 이루어지고 있다. 녹조중의 하나인 남조류가 만들어내는 마이크로시스틴은 직접 섭취하면 간 괴사까지 일으키는 독성물질로 알려져 있으며, 최근 4대강 녹조 발생 지역에 살고있는 어패류의 체내에 마이크로시스틴이 축적돼 이를 섭취하기만 해도 이차 독성이 나타나는 것으로 확인되었다. 특히 낙동강은 가뭄과 같은 기상학적 영향에 따른 수질환경적 변동특성이 뚜렷하여 수생태에 미치는 피해우려가 크며, 녹조발생에 취약한 유역이라 할 수 있다. 이는 기후변화에 따른 강우의 강도 및 편중으로 영양물질 유출의 증가와 표층 온도 상승과 함께 밀도류에 의해 성층이 심화되면서 표층에서의 극심한 녹조 발생이 이루어지는 것으로 설명할 수 있다. 따라서 본 연구에서는 연구대상지점으로 낙동강유역을 선정하여 물환경 빅데이터 구축을 통해 상세 유역현황을 파악하고 데이터마이닝 기법을 이용하여 녹조발생에 따른 수질환경적 변동특성 및 영향인자를 분석하고자 한다. 또한 가뭄에 따른 수질환경적 취약지역에 대한 선제적 관리방안을 도출하기 위해 지점별 취약성 평가방안을 제시하고자 한다.

  • PDF

Seasonal Patterns of Reservoir Thermal Structure and Water Column Mixis and Their Modifications by Interflow Current (인공호에서 수온의 수직분포와 수층혼합의 계절적 변화 및 중층수 유입 현상의 영향)

  • An, Kwang-Guk
    • Korean Journal of Ecology and Environment
    • /
    • v.34 no.1 s.93
    • /
    • pp.9-19
    • /
    • 2001
  • contrasting monsoon between 1993 and 1994 produced an interannual difference in hydrology. Theoretical water residence time (TWRT) in monsoon 1993 averaged 27 d, which was>3 months shorter compared to the TWRT in monsoon 1994. A dominant physical process influencing thermal stratification, water movement, and mixing regime was an interflow current in 1993. During summer 1993, river water plunged to mid-lake (location 27 km) and passed through the 10${\sim}$20m stratum of the reservoir, resulting in an isolation of epilimnetic lake water from advected river water. The interflow disrupted thermal stratification and produced a meta-hypolimnetic warming of >4$^{\circ}C$ downlake, thereby increased a mixing depth (>13 m). In contrast, during monsoon 1994 density currents were not observed and strong thermal stratification occurred in the entire reservoir, resulting in > 2 fold greater thermal resistance (8.2${\times}10^{5}$ erg)compared to 1993 (4.0${\times}10^{5}$ erg). This reservoir was identified as a typical warm monomictic reservoir which showed one mixis during early winter. The timing of overturn, however, differed between the two years as a result of distinct contrast in TWRT and thermal regime; overturn in 1993 occured about one month earlier relative to that in 1994. Hypolimnetic warming was predictable in this system; the variation in discharge accounted (Y = 4.35-0.06X+0.10X$^{2}$, p<0.0001)for 98% of the interannual variation in hypolimnetic temperature. Overall data suggest that thermal stability, the timing of fall overturn, and water residence time in this system are primarily regulated by the intensity of monsoon.

  • PDF

Flow Visualization and Calculation at the Outlet of Propellant Tank Pressurizing Gas Injector (추진제탱크 가압용 인젝터 출구에서의 유동가시화 및 해석)

  • Kwon, Oh-Sung;Han, Sang-Yeop;Kwon, Ki-Jung;Chung, Yong-Cahp
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.38 no.1
    • /
    • pp.73-79
    • /
    • 2010
  • Propellant tank pressurizing gas injector is used in the pressurization system of liquid propellant rocket to reduce incoming gas velocity and distribute the gas in the tank. Temperature distribution in the propellant tank ullage is varied according to the gas injector shape, and it has influence on the required pressurant gas and thermal phenomena in the tank. In this paper, diffuser type gas injector was studied to make the ullage have stratified temperature distribution. Injected gas flow at the outlet of prototype diffuser was visulized using particle image velocimetry method and it was compared with the results of calculation. Calculation was well agreed with measurement and was used as an inlet condition of propellant tank ullage calculation.

Assessment of the Usefulness of the Water Spray for Fire Extinguishing in Case of Fire in Tunnels (터널 화재시 수분무 소화설비의 효용성 평가)

  • Rie, Dong-Ho;Lim, Kyung-Bum;Yoo, Ji-Oh
    • Fire Science and Engineering
    • /
    • v.22 no.5
    • /
    • pp.55-60
    • /
    • 2008
  • In this study, we conducted an FDS numerical simulation for the purpose of carrying out a basic assessment of the usefulness of the water spray for fire extinguishing. We analyzed the effect of securing the stability in temperature and smoke density in case of fire according to fire intensities (20MW, 50MW) and changes in wind speed. When there was no wind speed in tunnels, it was effective in securing the safety of people because the cooling effect of the water spray system had an excellent effect on reducing temperatures and smoke densities there. The higher a fire intensity is, the less effect it has on reducing smoke flows. When an air current exists in tunnels, its cooling effect disturbs the smoke stratification and lowers the visibility degree during evacuation. Therefore, the water spray for fire extinguishing should be put into action only after people take shelter during fire.

The Experimental Research for the Use Characteristics of the Passive and Active type Domestic Solar Hot Water Systems (자연형 및 설비형 태양열 온수기의 이용특성에 대한 실험적 연구)

  • Lee, Dong-Won;Kwak, Hee-You
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.5
    • /
    • pp.82-88
    • /
    • 2013
  • There are the stirring test and drain test in the daily performance test to determine the thermal performance of a domestic solar hot water system. The drain test is a test that measures the discharge heating rate while drain the hot water from the top of the storage tank and supply the city water to the bottom of the tank. From the perspective of the user, this drain test is more effective than the stirring test. In this study, the thermal performance were compared through the drain test for a passive type and an active type domestic solar hot water systems consisting of the same storage tank and collectors. At this point, a passive type was used the horizontal storage tanks, and an active type was used vertical storage tank. In the drain test, when the hot water drained up to the reference hot water temperature, an active type which have vertical storage tank represents excellent daily performance than a passive type which have horizontal storage tank regardless of weather conditions. The reason for this is because the vertical storage tank is advantageous to thermal stratification in the tank. After the drain test, the residual heat for the horizontal storage tank was much more than the vertical storage tank, but in the next day the amount of discharged heat were less than the those of vertical storage tank neither. Thus, the solar water heating system which have horizontal storage tank should be adopted preheating control method rather than separate using control method when connected with auxiliary heat source device.

질화규소 삽입층을 이용한 a면 질화갈륨 박막의 깊은 준위 연구

  • Song, Hu-Yeong;Seo, Ju-Yeong;Lee, Dong-Ho;Kim, Eun-Gyu;Baek, Gwang-Hyeon;Hwang, Seong-Min
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.08a
    • /
    • pp.230-230
    • /
    • 2010
  • 질화갈륨 기반의 III족-질화물 계열의 반도체 물질은 녹색-자외선 영역의 발광다이오드에 응용되어 왔으며 고효율, 고휘도 발광소자의 구현 및 성능 향상을 위해 많은 연구가 진행되었다. 일반적으로 널리 사용되어온 c축 방향으로 성장된 질화갈륨 기반 발광다이오드에서는 활성층의 에너지 밴드구조가 내부전기장에 의해 변형되어 전자와 정공의 재결합 확률이 저하된다. c축 방향으로 형성되는 내부전기장은 축방향으로의 자발적 분극화와 높은 압전 분극 현상에 기인한다. 이와 같은 분극 성장에서의 내부양자효율 저하 현상을 해결하기 위하여 내부 전기장이 존재하지 않는 a축과 m축과 같은 무분극 방향으로의 성장이 집중적으로 연구되고 있다. 현재 사파이어 기판위에서 무분극 성장된 박막은 높은 밀도의 결함이 발생하여 고품위의 발광다이오드 동작에 어려움을 겪고 있다. 최근 결함 밀도를 낮추고 높은 결정성을 갖는 무분극 질화갈륨 박막을 성장하기 위하여 2-단계 성장 방법, 나노구조층 삽입, 산화규소 마스크 패턴 등 다양한 성장 방법들이 연구되어 주목할 만한 연구 결과들이 보고되고 있다. 다양한 성장 방법들에 의해 성장된 박막들은 고유한 특성들을 보이는데, 특히 박막 성장방법에 따라 박막 내부에 형성되는 깊은 준위의 특성들은 발광다이오드의 소자 특성에도 큰 영향을 미치게 되므로 무분극 박막에서의 깊은 준위에 대한 연구가 필요하다. 본 연구에서는 금속-유기 화학기상증착 방법으로 r면의 사파이어기판 위에 a면의 질화갈륨을 성장시켰다. 고품질의 결정성을 구현하기 위해 저온 핵형성층, 3차원 성장층, 2차원 중간온도 성장층, 2차원 성장층의 4개 버퍼층을 사용하였으며, 질화규소 나노구조층을 삽입함으로써 고품 위의 a면 질화갈륨 박막을 구현하였다. 성장된 a면 질화갈륨 박막에 형성된 깊은 준위들은 접합용량과도분광법을 이용하여 분석되었으며 질화규소 삽입층의 유무에 따른 깊은 준위의 특성 차이에 대한 연구를 수행하였다.

  • PDF

An Application of Algebraic Stress Model to a Two-Dimensional Buoyant Surface Jet (2차원 표층밀도분류에 대한 대수응력모델의 적용)

  • 김기흥;함계운;박준일;허재영
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.7 no.3
    • /
    • pp.248-256
    • /
    • 1995
  • The numerical study on the surface buoyant jets has remained of requiring more intensive investigation for problems due to the treatments of free surface, Reynolds stress/flux terms in turbulent flow and especially buoyancy effects on the turbulent fluctuation. etc. The verification of predicted results from the numerical study continues in the qualitative study. because of the lack of experimental data, which seems to be due to the difficulties in measuring the turbulent fluctuations in concentration or temperature fields. In this study, the computer program of Algebraic Stress Model has been developed to investigate the behaviours of two-dimensional surface buoyant jets with free surface boundary condition. The computational results are compared with published experimental data. By comparing these results with experimental data. it is found that this model can predict fairly well the flow characteristics of two-dimensional surface buoyant jets in the momentum-dominant region and buovancy-dominant region. Especially, it is proved that this model can predict the flow characteristics reasonably in buoyancy-dominant region stably stratified due to buoyancy effect.

  • PDF

Thermal Analysis of Prelaunch Transients in Cryogenic Oxidizer Tank of Liquid Propulsion Rocket (발사대기 중인 액체추진 로켓의 극저온 산화제 탱크 내 비정상 열해석)

  • Kim, Kyoung-Hoon;Ko, Hyung-Jong;Kim, Kyoung-Jin;Cho, Kie-Joo;Oh, Seung-Hyub
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.12 no.4
    • /
    • pp.33-41
    • /
    • 2008
  • The prelaunch thermal transients in the cryogenic oxidizer tank of liquid propulsion rocket subjected to uniform heat flux from outside are numerically analyzed through thermodynamic equations and heat and mass transfer relations. The prelaunch stage is assumed to be composed of five idealized sub-stages including pressurization process by helium gas injection. The Peng-Robinson equation of state is utilized in the lumped analysis of ullage gas. The liquid region is divided into a number of horizontal layers of uniform properties to account for the thermal stratification. The computational result for the typical case shows that the temperature rise of liquid oxidizer is less than 1K and the adsorbed helium into the liquid is approximately 10g.