• Title/Summary/Keyword: 온도궤적

Search Result 31, Processing Time 0.02 seconds

Unsteady State Heat Transfer Analysis of Drum Brake System (드럼 브레이크 시스템의 비정상 열전달 해석)

  • 이계섭;국종영;천인범
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.7 no.9
    • /
    • pp.172-181
    • /
    • 1999
  • The brakes employed on commercial vehicles must be able to withstand three types of demanding services which are use-emergency stops from high speed, many repeated stops as in a delivery or bus route, and speed control in mountain descents. Two type of friction brakes are in use ; drum breaks and disc brakes. Drum brakes are of the internally expanding type in which two shoes fitted externally with friction material are forced outward against the inside of a rotating drum on the wheel unit. In this case, the Braking power is produced by the friction force between a drum and a lining, and is converted into heat. In this research an unsteady state heat transfer analysis for drum brake system of heavy truck has been performed by ABAQUS/standard code in the case of single-braking and the repeated braking condition. The temperature histories obtained by the finite Element analysis have been compared with the result calculated by the simplified formulation and the result obtained by the experiment of real vehicle conditions.

  • PDF

Studies on the Combustion Characteristics and NO Distribution in the Pulverized Coal Fired Boiler (대용량 미분탄 보일러의 연소특성 및 NO 분포 특성 연구)

  • Park, Ho-Young;Kim, Young-Joo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.5
    • /
    • pp.552-559
    • /
    • 2008
  • Three dimensional numerical analysis were performed to investigate the combustion characteristics in a tangentially fired pulverized coal boiler. The predicted values at the outlet of economizer for the gas temperature, O$_2$, NO, CO were been compared with the measured data. By using the actual operating conditions of the power plant, the distribution of velocity, gas temperature, O$_2$, CO, CO$_2$ and NO as well as the particle tracking in the boiler were investigated. Throughout the present study, the non-uniform distribution of flue gas temperature in front of the final superheater might be resulted from the residual swirl flow in the upper furnace of the boiler. The present analysis on non-uniform distribution of the gas temperature could provide the useful information to prevent the frequent tube failure from happening in the final superheater of the tangentially coal-fired boiler.

Improvement of Color Reproduction Using Gamma and CCT Correction on Small LCD Display for Mobile Phone (휴대폰용 소형 LCD 디스플레이에서 감마 및 상관 색온도 보정을 이용한 색재현 성능 향상)

  • Han Chan-Ho;Sohng Kyu-Ik;Kwon Seong-Geun
    • Journal of Korea Multimedia Society
    • /
    • v.9 no.4
    • /
    • pp.451-459
    • /
    • 2006
  • Color reproduction of small LCD display is quite different from that of standard CRT due to the difference of physical, electrical, and optical characteristics. In this paper, we propose a simple and practical method using gamma and CCT correction for improvement of color reproduction on a small LCD display. First, we investigate characteristics of a small LCD display such as brightness, uniformity, color temperature, white and black balance, and nonlinear gamma. And, we also analyze color reproduction region and CCT trajectory according to LCD's input levels. Finally, the optimum gamma and CCT compensation method using LUT is proposed, and our proposed method was realized at mobile phone without hardware modification. In the experimental results, the result image of proposed algorithm is more close to standard color.

  • PDF

Development of 100[W] LED Flood Lighting with Tunable Colors and Color Temperatures (광색가변 및 색온도 제어용 100[W]급 투광기 개발)

  • Youn, Jin-Sik;Kim, Gi-Hoon;Song, Sang-Bin;Lim, Young-Cheol
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.12
    • /
    • pp.1-9
    • /
    • 2008
  • This paper is about l00[W] discrete LED floodlight lighting system, light color and color temperature to be controlled using the 3[W] RGBA LED, is developed the product with optical, heat dissipation, circuit, luminaire and system design. The result, color temperature is changed corresponding to black body locus from 2,000[K] to 10,000[K] and The Color Rendering Index(C.R.I) is achieved from 71 to 91 by high C.RI. Driving voltage is $90{\sim}250[Vac]$, circuit efficiency is 87[%], P.F is more than 93. moreover the LED lens is designed to achieve narrow, middle, wide beam angle, heat dissipation design is executed to minimize variation of luminous output by the surroundings temperature and to ensure reliability.

Computer Simulation of Liquid-Fuelled Combustor in Hot Vitiated-Air Stream (고온.저산소 농도영역중의 분무연소해석)

  • 김태한;최병륜
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.12
    • /
    • pp.3187-3195
    • /
    • 1993
  • Combustion of liquid-fuelled combustion in a high-temperature vitiated-air stream was studied. The mathematical formulation comprise the application of Eulerian conservation equation to the gas phase and Lagrangian equation of droplet motion. The latter is coupled with a droplet-tracking technique (PSI-CELL Model) which regard the droplet phase as a source of mass, momentum, and energy to the gaseous phase. Reaction rate is determined by taking into account the Arrhenius reaction rate based on a single-step reaction mechanism. The calculated profiles show somewhat uncertainess at the upstream, but bases data for designing the combustor followed by 2-phase flow were obtained.

A Theoretical Study for the Thermal Diffusivity Measurement Using Photothermal Deflection Scheme (광열편향법을 이용한 열확산계수 결정에 대한 이론적 연구)

  • 전필수;이은호;유재석;목재균;최강윤
    • Journal of Energy Engineering
    • /
    • v.10 no.1
    • /
    • pp.63-70
    • /
    • 2001
  • 재료의 열확산계수를 비접촉적인 방법으로 구하기 위하여 광열편향법에 대한 3차원 모델을 해석하였다. 이 방법은 가열빔이 재료에 광학적으로 흡수될 때 검사빔의 초기궤적이 시편과 시편주의 매질의 온도상승으로 인하여 나타나는 굴절지수의 구배에 의하여 검사빔이 편향되는 원리를 이용하는 것이다. 기존의 연구에서는 주로 가열빔과 검사빔의 상대거리를 변화시키면서 편향의 위상각을 측정하여 열확산계수를 결정하였다. 하지만 본 연구에서는 고정된 상대거리에서 가열빔의 변조주파수를 변화시키면서 편향의 위상각을 계산하여 열확산계수를 구할 수 있는 관계식을 제시하였다. 본 연구에서 제시한 열확산계수 결정 방법은 다른 방법에 비하여 실험과 해석이 간단하고 비교적 측정하기가 어려운 상대거리에 영향을 받지 않는 방법이다.

  • PDF

ICAP/4, Magnetics Designer, Solar Pro (다한테크의 시뮬레이션 툴 소개)

  • Mun, Yeong-Je
    • KIPE Magazine
    • /
    • v.13 no.4
    • /
    • pp.28-32
    • /
    • 2008
  • Power Supply Designer는 부품설계, large-sign -al 시뮬레이션, feedback control design 그리고 소신호 해석 등 완전한 스위칭 전원공급장치(SMPS)의 설계를 위한 시뮬레이션 프로그램입니다. 또한 최종 정확도 모델링 기술을 사용한 전류-모드 시뮬레이션, CCM & DCM 컨버터 시뮬레이션, loop gain이 포함된 컨트롤 시스템의 해석, 필터 디자인 및 해석, 모든 주요 부품에 대한 파워손실 측정 및 스트레스 해석을 하기 위한 빠르고 순환적인 시뮬레이션과 시뮬레이션시 자주 발생하는 Convergence 에러를 최소화할 수 있는 Convergence 마법사 기능을 수행할 수 있습니다. Power Supply Designer는 ICAP/4 Power Delu -xe라는 시뮬레이터와 인덕터 및 트랜스포머를 설계할 수 있는 Magenetics Designer가 패키지로 구성이 되어 있는 제품입니다. Solar Pro는 일사량, 온도, 각 지역의 위치정보에 대한 데이터와 태양광모듈에 대한 데이터를 고려하여 그림자 분석, I-V계산, 발전량계산, 경제성분석을 제공하는 솔루션입니다. 또한 그림자의 궤적과 발전량을 계산하여 애니메이션으로 볼 수가 있고 경제성을 포함한 시스템 성능을 표시할 수 있기 때문에 태양광 설치 고객에게 태양광 발전 시스템 자체에 대한 이해와 설득력 있는 프리젠테이션을 할 수가 있습니다.

Design of Soft X-ray Tube and Simulation of Electron Beam by Using an Electromagnetic Finite Element Method for Elimination of Static Electric Field (전자기 유한요소법 전자빔 시뮬레이션을 이용한 정전기장 제거용 연한 X-선관 설계 특성 연구)

  • Park, Tae-Young;Lee, Sang-Suk;Park, Rae-Jun
    • Journal of the Korean Magnetics Society
    • /
    • v.24 no.2
    • /
    • pp.66-69
    • /
    • 2014
  • The spreading tube of X-ray cathode tube displayed with an electromagnetic finite element method was designed. To analyze a feature design and the concrete coordinate performance of soft X-ray tube modeling, the orbit of electron beam was simulated by OPERA-3D SW program. The fixed conditions were the applied voltage, the temperature, the work function of thermal electron between cathode and anode of tungsten. Through the analysis of distribution of electron beam and the variation of dividing region, the design of soft X-ray spreading tube equipped with two cross filaments was optimized.

MTPA control algorithm for an IPMSM drive reflecting the PM flux linkage variation (영구자석 쇄교 자속 변화를 고려한 매입형 영구자석 동기전동기의 MTPA 제어 알고리즘 개발)

  • Sungmin, Choi;Seong-ho, Ryu;Jae Suk, Lee
    • Journal of IKEEE
    • /
    • v.26 no.4
    • /
    • pp.653-658
    • /
    • 2022
  • This paper presents a Maximum Torque per Ampere (MTPA) control algorithm for an interior permanent magnet synchronous motor (IPMSM) drive considering the permanent magnet (PM) flux linkage variations due to PM temperature variation. PM flux linkage are estimated in real time via a Gopinath style stator flux linkage observer and a torque error correction factor is calculated from the estimated PM flux linkage. A 2-dimensional (2D) MTPA look-up table (LUT) is developed to achieve the MTPA trajectory reflecting PM flux linkage variation for compensating torque error occurred by parameter variation. The proposed IPMSM control algorithm is verified through simulations.

Distance Measurement of Small Moving Object using Infrared Stereo Camera (적외선 스테레오 카메라를 이용한 소형 이동체의 거리 측정)

  • Oh, Jun-Ho;Lee, Sang-Hwa;Lee, Boo-Hwan;Park, Jong-Il
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.49 no.3
    • /
    • pp.53-61
    • /
    • 2012
  • This paper proposes a real-time distance measurement system of high temperature and high speed target using infrared stereo camera. We construct an infrared stereo camera system that measure the difference between target and background temperatures for automatic target measurement. First, the proposed method detects target region based on target motion and intensity variation of local region using difference between target and background temperatures. Second, stereo matching by left and right target information is used to estimate disparity about real-time distance of target. In the proposed method using infrared stereo camera system, we compare distances in three dimension trajectory measuring instrument and in infrared stereo camera measurement. In this experiment from three video data, the result shows an average 9.68% distance error rate. The proposed method is suitable for distance and position measurement of varied targets using infrared stereo system.